Ecler MIMO88 User manual

v.20200828
MIMO88
DIGITAL MATRIXES
Installation Digital Matrix
USER MANUAL

2
INDEX
IMPORTANT REMARK...........................................................................................................3
IMPORTANT SAFETY INSTRUCTIONS..............................................................................3
IMPORTANT NOTE.................................................................................................................5
INTRODUCTION......................................................................................................................5
INSTALLATION .......................................................................................................................6
5.1. Location, assembly, ventilation .............................................................................................. 6
5.2. Connection to an AC outlet and switching on................................................................... 6
5.3. Signal input connections.......................................................................................................... 7
5.4. Audio Output Connections...................................................................................................... 7
5.5. ETHERNET port for programming and control ................................................................. 8
5.6. LINK BUS digital audio port .................................................................................................... 8
5.7. REMOTE ports 1 and 2 for digital remote controls.......................................................... 9
5.8. GPI Remote Control Ports .....................................................................................................10
5.9. GPO Remote Control Ports ...................................................................................................11
5.10. Remote control RS-232 Port .............................................................................................11
5.11. Front panel controls and LED indicators.........................................................................12
CLEANING ............................................................................................................................. 13
FUNCTION LIST.................................................................................................................... 13
FUNCTION DIAGRAM......................................................................................................... 14
TECHNICAL CHARACTERISTICS..................................................................................... 15
BLOCK DIAGRAM................................................................................................................ 21

3
IMPORTANT REMARK
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user
to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
WARNING (If applicable): The terminals marked with symbol of “ ” may be of
sufficient magnitude to constitute a risk of electric shock. The external wiring connected
to the terminals requires installation by an instructed person or the use of ready-made
leads or cords.
WARNING:To prevent fire or shock hazard, do not expose this equipment to rain or
moisture.
WARNING:An apparatus with Class I construction shall be connected to a mains
socket-outlet with a protective earthing connection.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus (including amplifiers) that produce heat.

4
9. Do not defeat the safety purpose of the polarized or grounding type plug. A
polarized plug has two blades with one wider than the other. A grounding type
plug has two blades and a third grounding prong. The wide blade or the third
prong are provided for your safety. If the provided plug does not fit into your outlet,
consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at the plugs,
convenience receptacles, and at the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Unplug the apparatus during lightening sorts or when unused for long periods of
time.
13. Refer all servicing to qualified personnel. Servicing is required when the apparatus
has been damaged in any way, such as power supply cord or plug is damaged,
liquid has been spilled or objects have fallen into the apparatus, the apparatus has
been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Disconnecting from mains: When switching off the POWER switch, all the
functions and light indicators of the unit will be stopped, but fully disconnecting
the device from mains is done by unplugging the power cable from the mains input
socket. For this reason, it always shall remain easily accessible.
15. Equipment is connected to a socket-outlet with earthing connection by means of
a power cord.
16. The marking information is located at the bottom of the unit.
17. The apparatus shall not be exposed to dripping or splashing and that no objects
filled with liquids, such as vases, shall be placed on apparatus.
NOTE: This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
WARNING:This product must not be discarded, under any circumstance, as
unsorted urban waste. Take to the nearest electrical and electronic waste
treatment centre.
NEEC AUDIO BARCELONA, S.L. accepts no liability for any damage that may be caused
to people, animal or objects due to failure to comply with the warnings above.

5
IMPORTANT NOTE
Thank you for choosing our Ecler MIMO88 Installation Digital Matrix!
It is VERY IMPORTANT to carefully read this manual and to fully understand its
contents before any connection in order to maximize your use and get the best
performance from this equipment.
To ensure optimal operation of this device, we strongly recommend that its maintenance
be carried out by our authorised Technical Services.
Ecler MIMO88 comes with a 3-year warranty.
INTRODUCTION
The MIMO88 is a fully programmable digital audio matrix, with the following features:
•8 balanced MIC/LINE inputs (independent phantom power per input channel).
•8 balanced LINE outputs.
•2 MONITOR outputs that can be used as auxiliaries.
•Expandable to 16 inputs/16 outputs by linking a second MIMO88 unit (getting a real
16 inputs and 16 outputs matrix). Connect the two units using a CAT5 crossover
cable (100 meters maximum distance).
•8 GPI control ports (General Purpose Input).
•8 GPO control ports (General Purpose Output).
•Programming and remote management via Ethernet using EclerNet Manager (or
point to point, with a direct CAT5 cable, or from an Ethernet network).
•Remote control via Ethernet clients of EclerNet Manager: simultaneous clients with
custom control panel.
•Remote control from third party external devices. (Crestron, AMX, Vity, Medialon,
etc. Registered trademarks of their manufacturers). TP-NET protocol, via Ethernet
or RS-232 ports.
•Remote control bus for WPTOUCH digital panels and MPAGE16 messaging
consoles (paging).
•Configuration memory (presets) management.
•Scheduled events based on calendar.
•Extensive DSP available:
oRouting matrix/mixer, from any input to any output with adjustable level
for crossover points (independent mixes of different inputs for each
output).
oMono or stereo channel processing.

6
oLevel control, mute, vu-meters and phase adjustment for inputs and
outputs.
oInternal signal generator (sine wave, pink noise, white noise, polarity test).
oParametric EQ on inputs and outputs.
oDelay on inputs and outputs.
oGate/compressor on input channels.
oCompressor/limiter on outputs.
oInput channel priority assignment (ducking).
oVirtual and physical messaging consoles (paging).
oAutomatic mixer.
The MIMO88 programming is done with EclerNet Manager. Please refer to the EclerNet
Manager software manual for more information.
INSTALLATION
5.1. Location, assembly, ventilation
The MIMO88 has been especially designed to be installed in a standard 19" rack, taking
up 1U.
It is very important not to enclose the MIMO88 or expose it to extreme temperatures as it
generates heat. It’s also necessary to promote the passage of fresh air through the
ventilation holes of the chassis, leaving at least one rack unit off between each device and
installed above and below it in the rack frame.
If the setup has several amplifiers in the same rack or in a closed cabinet with doors, it is
highly recommended to supply them forced ventilation, installing fans at the upper and
lower ends. This upward air flow will help to dissipate the heat generated inside.
5.2. Connection to an AC outlet and switching on
The MIMO88 operates under voltages between 90 and 264 V at 47 to 63 Hz. This device
features an over dimensioned power supply that adapts to the mains voltage in any
country of the world with no need to make any adjustments.
On the rear panel, there is a power switch for the unit (20) next to the IEC power
connector. On the front panel, a LED (7) lights up when the unit is switched on.
The mains cables must not be near the shielded cables carrying the audio signal, as this
could cause humming.

7
5.3. Signal input connections
The rear panel of the MIMO88 offers 8 balanced analogue signal inputs, "IN" (9),
accepting both line and microphone level signals. Input signal type selection and
management are carried out from EclerNet Manager application. Please refer to the
EclerNet Manager software manual for more information.
Signal input connectors are 3 position screw terminal block. The wiring is:
Hot or direct signal > Terminal +
Cold or inverted signal > Terminal -
Ground > Terminal ⊥
For unbalanced connection short-circuit pin ⊥to pin -.
5.4. Audio Output Connections
The rear panel of the MIMO88 offers 8 analogue
signal outputs, "OUT" (8), and two additional
"MONITOR" (10) outputs, all balanced and accepting
line level signals.
Signal output connectors are 3 position screw
terminal blocks. The wiring is:
Hot or direct signal > Terminal +
Cold or inverted signal > Terminal -
Ground > Terminal ⊥
For UNBALANCED connections, leave the –terminal unconnected.

8
5.5. ETHERNET port for programming and control
A RJ45 type connector (11) allows connecting the equipment to an Ethernet network:
•Management from EclerNet Manager application. Please refer to the EclerNet
Manager software manual for more information.
•Possibility of direct connection (point to point) between a computer and a MIMO88
unit.
•Connection to third party other devices. (Crestron, AMX, Vity, Medialon, etc.
Registered trademarks of their manufacturers). Protocol used: Ecler TP-NET. See
the TP-NET protocol manual for more information.
5.6. LINK BUS digital audio port
A RJ45 type connector (12) allows connecting the equipment to a second MIMO88 unit
for a two-way exchange of digital audio and control data between the two units, the
whole behaving as a real matrix with 16 inputs and 16 outputs. The maximum permissible
distance between the two units using a standard CAT5 cable is 100 meters.
To work in 16x16 mode, one of the two coupled MIMO88 units (linked by BUS LINK)
assumes the role of MASTER and the other one the role of SLAVE. MASTER or SLAVE
mode is set by the selector (13) located on the rear panel of each unit. In single MIMO88
setups, selector position is irrelevant.
In 16x16 mode, the two units behave as a single device with 16 inputs and 16 outputs.
All Ethernet programming and remote control of the MASTER-SLAVE pair is done with
EclerNet Manager application and communication uses the Ethernet port of the MASTER
unit only, it’s not necessary to use the Ethernet port of the SLAVE unit. (Except for
updating the firmware).
Caution: two MIMO88 units coupled by BUS LINK should be linked with a crossover
cable, i.e. with a CAT5 cable dedicated to the BUS LINK ports of both units, up to 100
meters long, and without intermediate Ethernet hardware or other. Please refer to
the EclerNet Manager software manual for more information.

9
RJ-45 CONNECTOR WIRING "CROSSOVER"
RJ-45 (1)
COLOR
RJ-45 (2)
PIN 1
WHITE/ORANGE
PIN 3
PIN 2
ORANGE
PIN 6
PIN 3
WHITE/GREEN
PIN 1
PIN 4
BLUE
PIN 7
PIN 5
WHITE/BLUE
PIN 8
PIN 6
GREEN
PIN 2
PIN 7
WHITE/BROWN
PIN 4
PIN 8
BROWN
PIN 5
5.7. REMOTE ports 1 and 2 for digital remote controls
The REMOTE 1 and REMOTE 2 ports (14) are two connection
points for the digital bus of remote control devices such as
WPTOUCH wall panel or MPAGE16 messaging console (paging).
Each of them can be connected to a digital bus branch, at which the
various remote devices will be daisy-chained, the last one being
loaded with a 120 termination resistance between CAN HIGH
and CAN LOW.
Refer to the remote device documentation (WPTOUCH, MPAGE16, etc) for more
information about your connection and controls.
Refer to the EclerNet Manager application manual for more information about MIMO88
programming to manage remote devices connected to REMOTE1 or REMOTE2.

10
5.8. GPI Remote Control Ports
The rear panel of the MIMO88 offers 8 GPI inputs (16) for 0-10 VDC continuous control
voltage. Each of these inputs can be connected to an external physical device
(potentiometer, contact closure, continuously variable voltage 0-10V DC, etc.) and
assigned to a MIMO88 function, as for example:
•Input, output channel or matrix crosspoint volume remote control by means of a
WPVOL physical knob or an Ecler WP Series WPVOL-IR remote control
•MUTE or SOLO activation/deactivation by means of a switch or contact closure
•Recalling a preset with a push button or contact closure
GPI connectors are screw terminal blocks with three-contacts. The wiring is as follows:
Positive, + 10 VDC > Pin +
Variable voltage, 0-10 VDC > Pin ↑
Ground > Pin ⊥
WPaVOL connection to MIMO serial GPI ports
WPaVOL-SR connection to MIMO serial GPI ports
Jumpers position: ALOG / LIN →LIN position
+12 / +10 →+12 position
Jumpers position: ALOG / LIN →LIN position
+12 / +10 →+12 position
WPaVOL RJ45 pin 6 (+12VDC/+10VDC)
WPaVOL RJ45 pin 2 (Remote ZONE.)
WPaVOL RJ45 pin 1, 3 or 7 (GND)
WPaVOL-SR RJ45 pin 6 (+12VDC/+10VDC)
WPaVOL-SR RJ45 pin 2 (Remote VOL.)
WPaVOL-SR RJ45 pin 1, 3 or 7 (GND)
WPaVOL-SR RJ45 pin 8 (Remote VOL.)
WPaVOL-SR RJ45 pin 1, 3 or 7 (GND)

11
Connecting cables can be up to 500 meters with a minimum section of 0.5 mm2.
Consult your ECLER dealer or www.ecler.com about the WP series remote control wall
panels and other accessories available for connection to the REMOTE/VCA port.
5.9. GPO Remote Control Ports
The rear panel of the MIMO88 offers 8 NO/NC (normally open/ normally closed) relay
outputs (17). Each of these outputs may be assigned to a MIMO88 function, such as a
button of EclerNet Manager (MUTE key, SOLO key, etc.). This makes it possible to interact
with external devices such as projection screen motors or movable partitions, lights,
sirens, other equipment GPI entries, etc.3.10. Remote control RS-232 Port
5.10. Remote control RS-232 Port
The built-in RS-232 port in the rear panel allows an external device to communicate with
an MIMO88 unit via a serial connection. Said connection uses the TP-NET protocol syntax
so to enable the external device to obtain the value of any of the parameters of the
MIM088 unit (by "GET" commands) and/or modify said values (“SET” commands). See
the TP-NET protocol manual for more information.
The serial connection should comply with the following specifications:
Baud rate: 57600 (fixed, no auto negotiation)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
WIRING RS232 –DB9
RS232
DB9
Tx
Pin 2 (RxD)
Rx
Pin 3 (TxD)
Gnd
Pin 5 (Signal Gnd)

12
5.11. Front panel controls and LED indicators
The following elements are available on the MIMO88 front panel:
•MONITOR output (marked with a headphones symbol): it produces the same
monitoring signal already available via the rear panel screw terminal block, but here
on a ¼" TRS jack and with a rotary volume control (2 ) for listening through
headphones. It is especially useful for listening to input or output signals without
disturbing the normal operation. In 16x16 mode both MIMO units receive the same
signal. The monitored signal is selected with EclerNet Manager control software.
Please refer to the EclerNet Manager software manual for more information.
•Input LED indicators: indicate the presence of audio signal at the unit’s input, and
its intensity level (green, amber and red indicate in this order the increased intensity
level)
•Output LED indicators: indicate the presence of audio signal at the unit’s output,
and its intensity level (green, amber and red indicate in this order the increased
intensity level)
•Status LED indicators (STATUS):
oDATA:
▪Off: there is no connection to EclerNet Manager even if connected
to Ethernet.
▪On: connected to EclerNet Manager or to other third party
application via TP-NET protocol. Flashing: data traffic with EclerNet
Manager or another application.
oLINK:
▪1. If the device is configured as 8x8 MASTER, the LED is
permanently off.
▪2. If the device is configured as 16x16 MASTER:
•If everything is correct (SLAVE is connected and there is no
communication error), the LED quickly and continuously
toggles between green (50ms) and unlit (50ms)
•If there is a communication error with the SLAVE, the LED
quickly toggles between green (50ms) and red (200ms)
•If no SLAVE is connected (or if connected equipment is
another MASTER), the LED slowly toggles between green
(800ms) and red (200ms)
▪3. If the device is configured as SLAVE:
•If everything is correct (MASTER is connected and there is
no communication error), the LED quickly and continuously
toggles between orange (50ms) and unlit (50ms)
•If there is a communication error with the MASTER, the LED
quickly toggles between orange (50ms) and red (200ms)

13
•If no MASTER is connected (or if connected equipment is
another SLAVE), the LED slowly toggles between orange
(800ms) and red (200ms)
oPOWER: illuminates when the unit is in operation. It flashes if there is an
error in the unit or if firmware is not correct. It also flashes when you update
firmware
CLEANING
The front panel should not be cleaned with dissolvent or abrasive substances because
silk-printing could be damaged. To clean it, use a soft cloth slightly wet with water and
neutral liquid soap; dry it with a clean cloth. Be careful that water never gets into the unit
through the holes of the front panel.
FUNCTION LIST
1. Headphones connection stereo jack
2. Volume control for the headphones output, VOL
3. Input signal indicators, INPUTS
4. Output signal indicators, OUTPUTS
5. Data traffic indicator, DATA
6. Link (with another unit) indicator, LINK
7. Power on indicator, POWER
8. Signal output screw terminal, OUT
9. Signal input screw terminal, IN
10. Signal output screw terminal, MONITOR
11. RJ-45 connector, ETHERNET
12. RJ-45 connector, LINK BUS
13. MASTER –SLAVE selector, MASTER SLAVE
14. Screw terminals for digital remote control, REMOTE
15. Screw-assembled remote-control terminals via the TP-NET, RS-232 protocol
16. Screw terminals for continuous voltage control, GPI
17. Screw terminal for relay output, GPO
18. Mains socket
19. Fuse holder
20. Power switch

14
FUNCTION DIAGRAM

15
TECHNICAL CHARACTERISTICS
DSP
DSP 2x 32/64bit
Sampling Rate 48kHz
Latency IN to OUT <2.9ms (+1ms for 16x16)
Converters
Resolution 24bit AKM
Dynamic Range AD:110dB, DA: 115dB
Analog
8 Input/Output (expandable to 16x16) Terminal block (Symmetrical)
2 monitor output Terminal block (Symmetrical)
Headphones related Jack ¼
Analog Input headroom +27dBV = +30dBu
Max. output level +18dBV = +21dBu
Input sensitivity @ 0dBV out From -50dBV to
+10dBV in 0.5dB step
Input Impedance Balanced, >4k
Phantom power +42VDC, 5mA max.
software switched
Headphones >200mW/200
Frequency response (-3dB) 5Hz to 24kHz
Flatness better than ±0.1dB
THD+Noise @ 1kHz, 0dBV input (line) <0.004%

16
THD+Noise @ 1kHz, -40dBV input (mic.) <0.008%
Output Noise floor FFT (20Hz - 20kHz) better than 115dB
Interchannel crosstalk (20Hz - 20kHz) better than 90dB (100dB typ.)
Channel Leakage (20Hz - 20kHz) better than 100dB (115dB typ.)
CMRR 20Hz- 20kHz 65dB typ.
Processing
Input Level (x8) Range: from Off to 0 dB
Mute: Yes
Signal Polarity reverse: Yes
Metering: VU+clip pre & post fader
Output Level (x8) Range: from Off to 0 dB
Mute: Yes
Solo: Yes
Signal Polarity reverse: Yes
Metering: VU+clip pre & post fader
Output Gain (x8) Range: from 0 to +6 dB
Input Delay (x8) from 0 to 1000 ms
Units: sec/ms/m/cm.
Output Delay (x8) from 0 to 1000 ms
Units: sec/ms/m/cm.

17
Parametric Eq. Types Bypass / On-Off all channels
(4 max per input) Param Eq. Freq: 20Hz-20kHz;
(8 max per output) Gain: -60/+12 dB
Q: 0.3 to 200
Low & High Shelf 6/12 dB/oct
Low & High Pass 6/12 dB/oct
All Pass 1/2 order
High & Low pass output Crossover filters (x8) Bypass On-Off
Butterworth in 6/12/18/24 dB/oct
Bessel in 12/18/24 dB/oct
Linkwitz-Riley in 12/24 dB/oct
Input Noise Gate (x8) Bypass On-Off
Threshold: from –80 dBV to +18 dBV
Depth: 0 dB to 80 dB
Knee: hard / soft
Attack time: from 0,1 ms. to 500 ms.
Hold time: from 10 ms. to 3000 ms.
Release time: from 10 ms. to 1000 ms.

18
Input Compressor / Limiter (x8) Bypass On-Off
Threshold: from –36 dBV to +18 dBV
Ratio: 1:1 to inf:1 (limiter)
Knee: hard / soft
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Make up gain: from 0 to +10 dB
Input Frequency Shifter (x8) Per input. ON / OFF function
(Feedback Loop Reducer)
Output Limiter (x8) Bypass On-Off
Threshold: from –36 dBV to +18 dBV
Ratio: inf:1 (limiter)
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Built in Signal Generator Sine: from 20 Hz to 20 kHz
Polarity: from 20 Hz to 20 kHz
White noise
Pink noise
Stereo Linking Adjacent input / output channels
Linked processing
Matrix routing linked

19
Mix Matrix Size: 8x8 (1-MIMO88)
Size: 16x16 (2-MIMO88 with expan. link bus)
Vol: Input, Output, Crosspoint
Mute: Set/Clear individual, row, column, all
Input /output Mono/stereo selector
Meter: Input /output VU and clip
Pager (x4) Input: IN1 to IN8 (or to IN16 in 16x16)
Priorities: 4 (1 max, 4 min)
Depth: 0 dB to 80 dB
Attack time: from 0,1 ms. to 500 ms.
Release time: from 10 ms. to 1000 ms.
Chime Source: None, Melody 1, Melody 2
Chime Volume: from –12 dB to 0 dB
Mechanical
Dimensions 482.6x44x266.5mm
Weight 3.5kg
Supply
Mains 90-264VCA 47-63Hz
Power consumption 75VA

20
Miscellaneous
Management Connectivity Ethernet Base-Tx 10/100Mb Auto X-Over
CAT5 up to 100m.
Expansion LINK BUS (16x16 ch.) Proprietary over CAT5, Xover cable up to
100m.
Remote Bus 2, over twisted pairs; up to 1km
(see specific specs.)
GPI 8, from 0 to 10VDC or TTL level
GPO 8, 3 poles isolated relay; 1A, 48VDC max.
Aux. Power Supply for Remotes & GPI +12VDC, 1.2A. max. (short circuit protected)
Time and date retention (battery) 1 month aprox.
(ambient temperature dependant)
RTC accuracy ±1 minute /year
SOFTWARE
EclerNet Manager
Table of contents
Other Ecler Stereo System manuals