1. Application 19
2. Safety information 19
3. Faults and damage 19
4. Safety regulations 20
5. Ex-Data 22
5.1 x.com 5xx –Ex
5.2 x.com 6xx –Ex
6. Specifications 23
7. Battery 23
7.1 Changing the battery 23
7.1.1 Removing the battery 23
7.1.2 Inserting the battery 24
7.1.3 Charging the battery 25
7.2 Safety information 26
8. Repair 26
9. EC Declaration of Conformity 26
10. Declaration of conformity (x.com 5xx -Ex) 27
11. EC-Type Examination Certificate (x.com 6xx -Ex) 30
Note:
The current safety instructions, the EC Declaration of Conformity and the EU prototype testing
certificate can be downloaded from the relevant product page at www.ecom-ex.com, or
alternatively they can be requested directly from the manufacturer.

19
1. Application
The x.com 5xx -Ex and 6xx -Ex is an intrinsically safe, splash water-, (dust- according type of
device) and impact-resistant mobile phone for industrial application in areas with an increased
risk of explosion, in accordance with directive 1999/92/EC (ATEX 137) and 94/9/EC (ATEX 95).
2. Safety information
This operating manual contains information and safety regulations which are to be observed
without fail for safe operation in the described conditions. Non-observance of this information
and these instructions can have serious consequences or may violate regulations.
Please read these operating and safety instructions carefully before starting to use
the unit!
In case of any doubt (in the form of translation or printing errors) the German language opera-
ting instructions shall apply.
3. Faults and damage
If there is any reason to suspect that the safety of the unit has been impaired, it must be with-
drawn from use and removed immediately from the Ex-area. Measures must be undertaken to
prevent it from being restarted accidentally.
The safety of the unit may be compromised, if, for example:
- there is visible damage to the housing.
- the unit has been subjected to excessive loads.
- the unit has been improperly stored.
- the unit has been damaged in transit.
- unit markings or inscriptions are illegible.
- malfunctions occur.

20
- permitted limit values have been exceeded.
4. Safety regulations
Use of this x.com explosion-shielded mobile phone assumes that the operator observes the
conventional safety regulations and has read the certificate in order to eliminate faulty operation
of the unit.
The following points are to be observed:
- The unit may not be opened inside the Ex-area; the side cover should not be unscrewed
- The battery module may not be changed inside the Ex-area!
- The battery module may only be charged outside the Ex-area and only then using the
following appropriate chargers: universal charger LGX 00, desktop charger DCX 00, Car-Kit
CKX 00, car charger ALX 00
- The battery module may only be charged in a temperature range of 0 °C - 45 °C.
- Only accessories approved by ecom instruments GmbH may be used.
- The x.com 5xx -Ex and 6xx -Ex is not waterproof, therefore keep it dry!
- Observe the corresponding laws that are in force in the respective country regarding the use
of mobile phones while operating a vehicle!
- Use of the mobile phone in an airplane is not permitted!
- Switch off the mobile phone when in close proximity to medical instruments and if you are
requested to do so by corresponding regulations!
- Manufacturers of cardiac pacemakers recommend a minimum distance of 15.3 cm (6“) is
maintained between a mobile phone and a pacemaker.
- Do not switch on the mobile phone when the use of such devices is prohibited, as it may
cause interference or result in danger.

21
Only valid for model x.com 50x -Ex
- Only the original battery module AMX 50 (Li-Polymer 3.7V) should be used!
- The charging socket cover must be firmly engaged in the unit.
- When changing the battery (after use in the dust Ex-area) the unit and the battery terminals
are to be checked for cleanliness and cleaned, if necessary, using suitable means (brush,
compressed air, etc.).
- It must be ensured that the unit is not taken into zones 0 and 1 or 20 and 21!
Only valid for model x.com 51x -Ex
- In principle the unit should not be taken into the dust Ex-area!
- Only the original battery module AMX 51 (Li-Polymer 3.7V) should be used!
- The exposed interface contacts should always be checked for cleanliness and cleaned, if
necessary, using suitable means (e.g. brush, compressed air, moistened cloth / diluted soapy
water or commercially available handwash).
- It must be ensured that the unit is not taken into zones 0 and 1 or 20, 21 and 22!
Only valid for model x.com 60x -Ex
- Only the original battery module AMX 60 (Li-Polymer 3.7V) should be used!
- The charging socket cover (safety plug) must be firmly engaged in the unit.
- When changing the battery (after use in the dust Ex-area) the unit and the battery terminals
are to be checked for cleanliness and cleaned, if necessary, using suitable means (brush,
compressed air, etc.).
- It must be ensured that the unit is not taken into zones 0 or 20!
Only valid for model x.com 61x -Ex
- In principle the unit should not be taken into the dust Ex-area!
- Only the original battery module AMX 61 (Li-Polymer 3.7V) should be used!
- The exposed interface contacts should always be checked for cleanliness and cleaned, if
necessary, using suitable means (e.g. brush, compressed air, moistened cloth / diluted soapy
water or commercially available handwash).

22
- It must be ensured that the unit is not taken into zones 0 or 20, 21 and 22!
5. Ex-Data
5.1 x.com 5xx -Ex
EC-Declaration of conformity: ZELM 08 ATEX 3380 X
Ex-Designation:
x.com 50x -Ex x.com 51x -Ex
II 3G Ex ic IIC T4
II 3D Ex icD 22 T130°C
II 3G Ex ic IIC T4
x.com 50x -Ex and x.com 51x -Ex:
Approved for zone 2, device group II, explosion group IIC (explosive gases, vapours or mist),
temperature class T4.
Only x.com 50x -Ex:
Approved for zone 22, device group II, explosive dust, temperature T130°C
5.2 x.com 6xx -Ex
EC-Type Examination Certificate No.: ZELM 08 ATEX 0372 X
Ex-Designation:
x.com 60x -Ex x.com 61x -Ex
II 2G Ex ib IIC T4
II 2D Ex ibD 21 T130°C
II 2G Ex ib IIC T4

23
x.com 60x –Ex and x.com 61x –Ex:
Approved for zone 1, device group II, explosion group IIC (explosive gases, vapours or mist),
temperature class T4.
Only x.com 60x –Ex:
Approved for zone 21, device group II, explosive dust, temperature T130 °C
6. Specifications
Networks: GSM 900 MHz / 1,800 MHz
Power supply: Li-ion rechargeable battery with 2000 mAh capacity
Dimensions: x.com 5xx –Ex: 142 x 64 x 36 mm
x.com 60x –Ex: 153 x 64 x 36 mm
Weight: approx. 240g
CE-Designation: 0 0102
Ambient temperature: -20 °C ... +50 °C
Protection rating: IP64
7. Battery
7.1 Changing the battery
The AMX 5x or 6x for the x.com unit may only be changed outside the Ex-area. (The model
number AMX 60 may be followed by additional letters or numbers, which are of no relevance to
the Ex-area, e.g. AMX 50 / AMX 51 / AMX 60 or AMX 61.) Only those battery modules which are
approved by the manufacturer may be used. Other battery modules may not be taken.
7.1.1 Removing the battery
Follow these steps to remove the battery (for example, when exchanging the SIM card): After
removing the charging socket cover (safety plug for x.com 60x –Ex / not applicable for
x.com 51x –Ex and 61x-Ex) turn the phone over. Exert pressure in the centre of the recess on
the cover and then remove it.

24
x.com 5xx -Ex and x.com 61x -Ex:
After removing the charging socket cover (x.com 50x –Ex) respectively the safety plug
(x.com 60x –Ex) - not applicable for x.com 51x -Ex and x.com 61x -Ex -, turn the mobile
phone.
7.1.2 Inserting the battery
Proceed as follows to insert the battery: Insert the battery module with the two catches (located
at the top of the battery) placed in the recesses in the mobile phone. Then press the bottom of

25
the battery module into the phone until the retaining spring audibly clicks in place. Mount the
charging socket cover (x.com 50x –Ex) respectively the safety plug (x.com 60x –Ex)
7.1.3 Charging the battery
Your phone is supplied with power via a rechargeable battery. Before a new battery
can be used for the first time it must have been charged for at least 4 hours. The
full battery performance is only obtained after a few operating cycles.
If the battery charge level falls below the operating value, the phone will indicate
this (the empty battery symbol flashes). When this appears charge the battery for at
least 15 minutes before making any other calls, in order to prevent your call from
being interrupted.
Proceed as follows to charge the battery:
Connect the charger to a wall outlet.
Insert the end of the charging plug into the designated charging socket.
The phone‘s battery will now be charged. The battery symbol indicates that the
battery is being charged. When the battery is fully charged the charging process
stops automatically. Remove the charging plug from the phone.
Batteries can become warm during the charging process. This is a normal occurrence.
NOTE
- There is a risk of explosion if the battery is not exchanged properly or if it is exposed to a
flame.
- Do not short-circuit the battery.
- The battery does not contain any parts that can be exchanged.
- The casing of the battery should not be opened under any circumstances.
- Only use ecom charging accessories (see point 4).
- The use of other chargers or batteries is not permitted. If such items are used, your
Ex-protection will expire.
- Used batteries are to be disposed of properly.

26
- If you do not intend using the phone for a prolonged period, you should remove the battery.
- We strongly advise against connecting your phone to the charger if the battery is not inserted.
- If the battery is completely discharged, the phone will not switch on. Connect the phone to
the charger. After charging for a few minutes the phone will switch on. When the Start option
appears in the display, you can use the phone again.
7.2 Safety information
Damaged batteries and chargers should be removed from use and sent to ecom instruments
GmbH for inspection.
Attention:
- Extreme temperatures can have an adverse effect on charging the battery module
AMX 5x or AMX 6x.
- Do not dispose of the battery module in a fire!
- Do not short-circuit the battery module!
- Dispose of the battery module in accordance with local regulations. Do not dispose of the
battery module with normal household waste.
8. Repair
Repairs are to be conducted by ecom instruments GmbH or by personnel or service centres
authorised by ecom instruments GmbH, because the safety of the unit needs to be tested after
repairs are implemented.
9. EC Declaration of Conformity
Further details regarding the declaration of conformity can be found at the following address:
http://www.ecom-ex.com in the download area.

27
10. Declaration of Conformity
(1) Declaration of conformity
Translation
(2) Devices and protection systems for proper designated use in areas with an increased risk of
explosion – Directive 94/9/EC
(3) EC type approval test certificate number
ZELM 08 ATEX 3380 X
(4) Device: Explosion-protected mobile phone X.com 50x -Ex and X.com
51x -Ex
(5) Manufacturer: ecom instruments GmbH
(6) Address: D-97959 Assamstadt
(7) The design of this device and its various approved embodiments are defined in the attachment
to this type approval test certificate..
(8) As the nominated body no. 0820 in accordance with article 9 of the EC council directive dated
March 23, 1994 (94/9/EC), the Testing and Certification Body ZELM Ex certifies conformance
with the basic health and safety requirements for the design and construction of devices and
protection systems for proper designated use in areas with an increased risk of explosion in
accordance with Appendix II of the directive.
The results of the examination are specified in the confidential inspection report No. ZELM Ex
0990724642.
(9) The basic health and safety requirements are met by virtue of conformance with
EN 60079-0:2006EN 60079-11:2007 EN 61241-0:2006 EN 61241-11:2006
(10) If the certification number is followed by an "X", then this indicates that special conditions exist
for the safe operation of the device. These special conditions are contained in the attachment to
this certificate.
(11) This EC type approval test certificate only refers to the construction/design, checking and testing
of the specified device or protection system in accordance with directive 94/9/EC. Further
requirements contained in this directive may apply with regard to the manufacturing process and
the supply of the device or protection system. Such requirements are not covered by this
certification.
(12) The device must be labelled with the following information:
II 3 G Ex ic IIC T4 or
II 3 D Ex icD 22 T130° C
Brunswick, 26.01.2009
Certification body ZELM ex
Dipl.-Ing Harald Zelm
Page 1 of 3
Declarations of conformity without a signature and stamp are not valid.
This declaration of conformity may only be circulated without alteration.
Extracts or alterations are subject to approval by the Prüf- und Zertifizierungsstelle ZELM ex
ZELM eX
Prüf- und Zertifizierungsstelle
Siekgraben 56 D-38124 Brunswick

28
(13) Attachment
(14) Declaration of conformity ZELM 08 ATEX 3380 X
(15) Description of the device
The explosion-protected mobile phones X.com 50x -Ex and X.com 51x -Ex provide
communication in explosive areas.
The "x" in the type designation is replaced by a digit or a letter to distinguish between permitted
versions of the device (e.g. software versions).
The devices should only be operated with the corresponding battery module and they should
only be charged outside the explosive area using the corresponding charging accessory. The
housing protection rating for the X.com 50x -Ex mobile phone is IP 64.
Permissible ambient temperature range: -20° C to +50° C
Models and classification:
Device type X.com 50x -Ex X.com 51x -Ex
Designation II 3G Ex ic IIC T4
II 3D Ex icD 22 T130° C
Ta -20° C - +50° C
II 3G Ex ic IIC T4
Ta -20° C - +50° C
Covering of the interface Interface cover - none -
Battery type AMX 50* AMX 51*
Inscription in the battery
compartment
Only for AMX 50 Only for AMX 51
Information on the battery AMX 50*
Only for X.com 50x -Ex
AMX 51*
Only for X.com 51x -Ex
The "*" in the type designation of the battery module is replaced by a digit or a letter to
distinguish between permitted versions.
Page 2 of 3
Declarations of conformity without a signature and stamp are not valid.
This declaration of conformity may only be circulated without alteration.
Extracts or alterations are subject to approval by the Prüf- und Zertifizierungsstelle ZELM ex
ZELM eX
Prüf- und Zertifizierungsstelle
Siekgraben 56 D-38124 Brunswick

29
Attachment
to the declaration of conformity ZELM 08 ATEX 3380 X
Electrical data
Power supply: from a corresponding battery module AMX 50* or AMX 51*
The internal electrical circuits are intrinsically safe.
Transmitting power: up to 2 W
Permissible ambient temperature range: -20° C to + 50° C
(16) Test report No.
ZELM Ex 0990724642
(17) Special conditions
1. The safety instructions are to be observed.
2. The devices may only be charged outside the explosive area using the corresponding
charger or the appropriate charging accessories.
3. Only the AMX 50* or AMX 51* battery modules may be used.
4. Opening or changing the battery modules is not permitted within the explosive area.
5. The interface cover of the X.com 50x -Ex must be firmly secured in the designated
manner within the explosive area.
(18) Basic health and safety requirements
satisfied by virtue of the standards
Brunswick, 26.01.2009
Certification body ZELM ex
Dipl.-Ing Harald Zelm
Page 3 of 3
Declarations of conformity without a signature and stamp are not valid.
This declaration of conformity may only be circulated without alteration.
Extracts or alterations are subject to approval by the Prüf- und Zertifizierungsstelle ZELM ex
ZELM eX
Prüf- und Zertifizierungsstelle
Siekgraben 56 D-38124 Brunswick

30
10. EC-Type Examination Certificate
Prüf- und Zertifizierungsstelle
ZELM Ex
(1) EC type approval test certificate
Translation
(2) Devices and protection systems for proper designated use in areas with an increased risk of
explosion – Directive 94/9/EC
(3) EC type approval test certificate number
ZELM 08 ATEX 0372 X
(4) Device: Explosion-protected mobile phone X.com 60x –Ex
(5) Manufacturer: ecom instruments GmbH
(6) Address: 0-97959 Assamstadt
(7) The design of this device and its various approved embodiments are defined in the attachment
to this type approval test certificate.
(8) As the nominated body no. 0820 in accordance with article 9 of the EC council directive dated
March 23, 1994 (94/9/EC), the Testing and Certification Body ZELM Ex certifies conformance
with the basic health and safety requirements for the design and construction of devices and
protection systems for proper designated use in areas with an increased risk of explosion in
accordance with Appendix II of the directive.
The results of the test are documented in the confidential test report no. ZELM Ex 1000724606.
(9) The basic health and safety requirements are met by virtue of conformance with
EN 60079-0:2006EN 60079-11:2007 EN 61241-0:2006 EN 61241-11:2006
(10) If the certification number is followed by an "X", then this indicates that special conditions exist
for the safe operation of the device. These special conditions are contained in the attachment to
this certificate.
(11) This EC type approval test certificate only refers to the construction/design, checking and testing
of the specified device or protection system in accordance with directive 94/9/EC. Further
requirements contained in this directive may apply with regard to the manufacturing process and
the supply of the device or protection system. Such requirements are not covered by this
certification.
(12) The device must be labelled with the following information:
II 2 G Ex ib IIC T4
II 2 0 Ex ibO 21 T130°C
Certification body ZELM Ex Brunswick, 01.04.2008
Dipl.-Ing. Harald Zelm
Page 1/2
EC type approval test certificates without a signature and stamp are not valid.
This EC type approval test certificate may only be circulated without alteration.
Extracts or alterations are subject to approval by the Prüf- und Zertifizierungsstelle (Test and Certification Body) ZELM Ex.
Prüf- und Zertifizierungsstelle ZELM Ex • Siekgraben 56 • D-38124 Brunswick

31
Test and Certification Body
ZELM Ex
(13) Attachment
(14) EC type approval test certificate ZELM 08 ATEX 0372 X
(15) Description of the device
The explosion-protected mobile phone X.com 60x -Ex provides communication in explosive
areas.
The "x" in the type designation is replaced by a digit or a letter to distinguish between permitted
versions of the device (e.g. software versions).
The device should only be operated with the corresponding battery module and it should only be
charged outside the explosive area using the corresponding charging accessory.
Electrical data
Power supply: from a corresponding battery module
AMX60*
(The "x" in the type designation is replaced by a digit or a
letter to distinguish between permitted versions).
The internal electrical circuits are intrinsically safe.
Transmitting power up to 2W
permissible ambient temperature range -20 °C to + 50 °C
(16) Test report no.
ZELM Ex 1000724606
(17) Special conditions
1. The safety instructions are to be observed.
2. The device may only be charged outside the explosive area using the corresponding
charger or the appropriate charging accessories.
3. Only the AMX 60* battery module may be used!
Opening or changing the battery module is not permitted within the explosive area.
4. The interface cover must be firmly secured in the designated manner within the explosive
area.
Certification body ZELM Ex Brunswick, 01.04.2008
Dipl.-Ing. Harald Zelm
Page 2/2
EC type approval test certificates without a signature and stamp are not valid.
This EC type approval test certificate may only be circulated without alteration.
Extracts or alterations are subject to approval by the Prüf- und Zertifizierungsstelle (Test and Certification Body) ZELM Ex.
Prüf- und Zertifizierungsstelle ZELM Ex • Siekgraben 56 • D-38124 Brunswick

32
1st Amendment
(Amendment in accordance with EC Directive 94/9, appendix III number 6)
to the EC type approval test certificate
Translation
ZELM 08 ATEX 0372 X
Device: Explosion-protected mobile phone X.com 60x -Ex
Manufacturer: ecom instruments GmbH
Address: D-97959 Assamstadt
Description of the amendment
The 1st amendment concerns the expansion of the explosion-protected mobile phone X.com 60x -Ex
series to include a model that is exclusively intended for use in areas with an explosive gas
environment.
The type designation of this model is: X.com 61x-Ex.
The "x" in the type designation is replaced by a digit or a letter to distinguish between permitted
versions of the device (e.g. software versions).
Furthermore, minor modifications of the internal configuration have been taken into account in the 1st
amendment to the EC type approval test certificate. The conformity of the device with the current
standards has been verified.
The devices should only be operated with the corresponding battery module and they should only be
charged outside the explosive area using the corresponding charging accessory.
The housing protection rating for the X.com 60x mobile phone is IP 64.
In the future the explosion-protected X.com 60x -Ex and X.com 61 x -Ex mobile phones may also be
manufactured in accordance with this 1st amendment and designated as follows:
Ignition protection class / designation: II 2 G Ex ib IIC T4 or
II 2 D Ex ibD 21 T130° C
Electrical data
Power supply: from a corresponding battery module AMX 60*
or AMX61*.
The internal electrical circuits are intrinsically safe.
Transmitting power: up to 2 W
Permissible ambient temperature range: -20° C to +50° C
All additional technical specifications as well as the information specified in the EC type approval test
certificate remain unaffected and are also applicable for this 1st amendment.
Page 1 of 2
EC type approval test certificates without a signature and stamp are not valid.
This EC type approval test certificate may only be circulated without alteration. Extracts or alterations
are subject to approval by the Prüf- und Zertifizierungsstelle (Test and Certification Body) ZELM ex
ZELM ex
Prüf- und Zertifizierungsstelle
Siekgraben 56
D-38124 Brunswick

33
1st Amendment
to the EC type approval test certificate ZELM 08 ATEX 0372 X
Models and classification:
Device type X.com 60x -Ex X.com 61x-Ex
Designation II 2G Ex ib IIC T4
II2DExibD 21 T130° C
Ta -20° C - +50° C
II 2G Ex ib IICT4
Ta -20° C - +50° C
Covering of the interface Safety Plug - none -
Battery type AMX 60* AMX 61*
Inscription in the battery
compartment
Only for AMX 60 Only for AMX 61
Information on the battery AMX 60*
Only for X.com 60x -Ex
AMX 61*
Only for X.com 61x-Ex
The "*" in the type designation of the battery module is replaced by a digit or a letter to
distinguish between permitted versions.
Special conditions:
1. The safety instructions are to be observed.
2. The devices may only be charged outside the explosive area using the corresponding charger or
the appropriate charging accessories.
3. Only the AMX 60* or AMX 61* battery modules may be used!
4. Opening or changing the battery modules is not permitted within the explosive area.
5. The interface cover of the X.com 60x -Ex must be firmly secured in the designated manner
within the explosive area.
Test report No.
ZELM Ex 1760824672
Basic health and safety requirements
The conformity of the device with the current standards has been verified within the scope of the 1st
amendment.
Furthermore, the basic health and safety requirements are met by virtue of conformance with:
EN 60079-0:2006 EN 60079-11:2007 EN 61241-0:2006 EN 61241-11:2006
Brunswick, 30.01.09
Certification body ZELM ex
Dipl.-Ing. Harald Zelm
Page 2 of 2
EC type approval test certificates without a signature and stamp are not valid.
This EC type approval test certificate may only be circulated without alteration. Extracts or alterations
are subject to approval by the Prüf- und Zertifizierungsstelle ZELM ex
ZELM ex
Prüf- und Zertifizierungsstelle
Siekgraben 56
D-38124 Brunswick

ecom instruments GmbH
·
Industriestr. 2 · 97959 Assamstadt · Germany
Tel.: + 49 (0) 62 94 / 42 24 0 · Fax: + 49 (0) 62 94 / 42 24 100
PA000297 / 5000 / 08 / 2009
WEEE-Reg.-Nr. DE 934 99306
0340AL02A02 06/09 Änderungen vorbehalten! Subject to change without notice!
Kommunikation
Mobile Computing
Portable Handlampen
Mess- & Kalibriertechnik
Communication
Torches/Flashlights
Mobile Computing
Measuring & Calibration
Copyright
©
2009 ecom instruments GmbH.
Der Inhalt dieses Dokuments darf ohne vorherige schriftliche Genehmigung durch die ecom instruments GmbH in keiner Form, weder
ganz noch teilweise vervielfältigt, weitergegeben, verbreitet oder gespeichert werden.
Der Inhalt dieses Dokuments wird so präsentiert, wie er aktuell vorliegt. Die ecom instruments GmbH übernimmt weder ausdrücklich
noch stillschweigend irgendeine Gewährleistung für die Richtigkeit oder Vollständigkeit des Inhalts dieses Dokuments, einschließlich,
aber nicht beschränkt auf die stillschweigende Garantie der Markttauglichkeit und der Eignung für einen bestimmten Zweck, es sei
denn, anwendbare Gesetze oder Rechtsprechungen schreiben zwingend eine Haftung vor. Die ecom instruments GmbH behält sich das
Recht vor, jederzeit ohne vorherige Ankündigung Änderungen an diesem Dokument vorzunehmen oder das Dokument zurückzuziehen.
Copyright
©
2009 ecom instruments GmbH.
The contents of this document, either in part or in their entirety, may not be reproduced, forwarded, distributed or saved in any way without
ecom instruments GmbH prior written consent.
The contents of this document are presented as they currently exist. ecom instruments GmbH does not provide any express or tacit
guarantee for the correctness or completeness of the contents of this document, including, but not restricted to, the tacit guarantee of
market suitability or fitness for a specific purpose unless applicable laws or court decisions make liability mandatory. ecom instruments
GmbH reserves the right to make changes to this document or to withdraw it any time without prior notice.
This manual suits for next models
7
Table of contents
Other Ecom Instruments Cell Phone manuals

Ecom Instruments
Ecom Instruments Ex-GSM 01 Installation instructions

Ecom Instruments
Ecom Instruments Ex-Handy 06 Installation instructions

Ecom Instruments
Ecom Instruments x.com 400/401 User manual

Ecom Instruments
Ecom Instruments Ex-Handy 05 User manual

Ecom Instruments
Ecom Instruments Ex-Handy 05 Installation instructions

Ecom Instruments
Ecom Instruments XP3410 IS Installation instructions

Ecom Instruments
Ecom Instruments Ex-CDMA 02 Installation instructions

Ecom Instruments
Ecom Instruments X.COM 21x -Ex Installation instructions

Ecom Instruments
Ecom Instruments Ex-GSM 01 EU User manual

Ecom Instruments
Ecom Instruments Ex-Handy 05 User manual