Ecosmar+ XL700 User manual

© Copyright 2004 - 2010 The Fire Company Pty Ltd - International Patent Pending - Trademark Registered - All Designs Registered. www.ecosmartre.com
Burner Kit
XL700
1
7

© Copyright 2004 - 2010 The Fire Company Pty Ltd - International Patent Pending - Trademark Registered - All Designs Registered. www.ecosmartre.com
Fuel Use Denatured Ethanol only.
Refer to www.ecosmartre.com for commercially available fuel names around the world.
Design Features Sophistication, elegance, cutting-edge performance and functionality dene the XL700 Burner, which has
been developed in response to overwhelming demand. A popular trend amongst designers and architects
has been to join several EcoSmart™ Fire burners in line to form an elongated ame, creating a stunning
centrepiece for use in both residential and commercial premises. The XL700 Burner includes bafes (for
fuel efciency), drafters (for ame stability), smart lling point, and a new design shut-off mechanism. As
with all EcoSmart™ Fire products, safety aspects have been thoroughly considered and implemented.
The XL700 Burner is designed for installation in commercial premises including ofces, bars and
restaurants as well as units, apartments and houses.
Construction Detail The EcoSmart™ XL700 Burner is made from Stainless Steel (Grade 304).
Outline of Burner features:
1. Filling Point comprising of 2 parts:
a) Spring Loaded Cap - separated from burning/ignition zone
b) Filling Box - engineered so that the jerry can spout is fully enclosed prior to releasing the fuel supply,
thus allowing lling at a high rate, whilst eliminating splashing as the fuel is being decanted.
2. Swivel ring – the accompanying lighting rod is inserted into this swivel ring to control the ip lid system.
3. Flip lid shut off system - The lid ips across the ignition zone which extinguishes the ame. When open it
also blocks access to the lling point to prevent lling the burner whilst in operation.
4. Volume/Setting Markings - enable you to determine fuel required / available.
5. Ignition point - the burner is best ignited from the right hand side of the ignition zone. This is the largest
section of the fuel chamber and it provides the clearest view of the fuel level and easiest access for ignition.
6. Top Tray - The custom built Top Tray supplied with this model is made from Stainless Steel (Grade 304).
It is designed to sit underneath the burner without being seen from above. The Top Tray is a compulsory
accessory to guard against heat transference and to collect any accidental spillage.
7. Spacers - There are “spacers” tted on all exterior panels and a “spacer” bar that separates the base of
the burner from the surrounding materials. This prevents any heat transference and enforces compulsory
clearances.
The EcoSmart™ Fire is designed and manufactured by The Fire Company Pty Ltd whose quality
management system is certied as being in conformity with ISO 9001:2008.
Accompanying Compulsory
Accessories
The XL700 Burner Kit is accompanied by an operational system that ensures the safety of the product.
Every aspect from decanting the fuel, lighting the ame, regulating the ame to extinguishing the ame, has
been thought through and accessorised in order to control the method of operation.
All models come with a Top Tray, Lighter, Jerry Can, Lighting Rod and Manual.
Recommended Accessories Fire Extinguisher, EcoSmart™ Fire Screen, Burner Cover.
Model Specications
The EcoSmart™ Burner is the core product of all EcoSmart™ Fires, being the chamber that houses the fuel. It offers ultimate exibility due to
its modular design which presents you with the opportunity to create an open re just about anywhere! The EcoSmart™ XL700 Burner can be
installed into any setting that complies with our Compulsory Installation and Clearance Specications.
Burner Kit
XL700
2
7
BurnerKits INSTALLATION,OPERATIONAND MAINTENANCE MANUAL www.ecosmartfire.com
INSTALLATION, OPERATION
AND MAINTENANCE MANUAL
Pleaseread these instructions completely
beforeoperating the EcoSmart™ Fire.
Burner Kits
BurnerOne BurnerTwo XLBurner TripleBurner
TheEcoSmart™ Fire is designed and manufactured by The
FireCompany Pty Ltd whose quality management system is
certifiedas being in conformity with ISO 9001:2000.
Visitwww.ecosmartfire.com to find a complete list of
distributorsand retail stores.
10Apollo Street, Warriewood NSW 2102, Australia
T:+61 2 9997 3050 F:+619997 6050
E:info@thefirecompany.com.au

© Copyright 2004 - 2010 The Fire Company Pty Ltd - International Patent Pending - Trademark Registered - All Designs Registered. www.ecosmartre.com
Clearances INSERTING WITHIN A FIREBOX SETTING:
The EcoSmart™ XL700 Burner can only be tted into a non-combustible rebox that has minimum
clearances of:-
W 900mm [35.4in] x H 500mm [19.7in] x D 350mm [13.7in].
Custom made reboxes must:
- Be made out of a non-combustible material such as stainless steel
- Be constructed to accommodate a Top Tray or “Twin Skin”
- Have built in spacers of 20mm [0.8in] on all sides to ensure that it does not sit directly against any
combustible materials and an air gap is incorporated for insulation around the box construction
INSERTING WITHOUT A FIREBOX SETTING:
REAR: A minimum of 40mm [1.6in] space between the burner edge/Top Tray edge and the rear wall (which
should be a non combustible material).
Warning: The rear wall should be a non combustible material.
If the rear wall is combustible, a distance of 600mm [23.6in] must be allowed for.
FRONT: A minimum of 65mm [2.6in] space between the burner and the front edge.
OVERHEAD: A minimum clearance of 1500mm [59.1in] from the burner mouth to the nearest combustible.
SIDES: A minimum clearance of 600mm [23.6in] from the burner edge to the nearest combustible.
BASE: Must be made of non-combustible material.
Model Specications
Burner Kit
XL700
3
7

© Copyright 2004 - 2010 The Fire Company Pty Ltd - International Patent Pending - Trademark Registered - All Designs Registered. www.ecosmartre.com
Model Specications
Burner Kit
XL700
4
7
Clearances CONVERTING AN EXISTING FIREPLACE:
In order to keep the heat from escaping through the ue, place a panel of non-combustible heat reective
material such as stainless steel across your ue opening or utilise the damper within the existing replace
setting to conserve heat.
All settings must incorporate a “Twin Skin”. If using the Top Tray that has been supplied with this model, the
cut out dimensions are:-
H 123mm [4.8] x W 680mm [26.7] x D 173mm [6.8].
Multiple burners may be installed into a replace setting however the ventilation requirements must be
adhered to at all times. It is imperative that when installing multiple burners you consider strongly the impact
of any accident and minimise it wherever possible.
A re extinguisher (AB:E type dry chemical extinguisher) is a compulsory accessory.
Installation Requirements There are many different variations available for installing
the EcoSmart™ XL700 Burner. In all cases, the EcoSmart™
XL700 Burner must:
- Be installed into non-combustible material ONLY
– for example stainless steel, concrete, brick, stone
- Be tted within a “Twin Skin”, such as the Top Tray included
with this model from The Fire Company Pty Ltd so that there
is a second barrier to capture any accidental spillage. If
the Twin Skin is not supplied by The Fire Company Pty Ltd
then it must undergo a “water tight” test prior to inserting the
EcoSmart™ Burner into place
- All gas connections or pipelines near your EcoSmart™
installation must be disconnected and made safe by an
appropriately qualied professional prior to installation
- Be installed into a xed and secure position before lling,
lighting and operating
- Be installed in a position that limits relocation requirements to
eliminate the risk of accidents caused by fuel spillage – they
are not designed to be relocated frequently
- Be installed into a level platform
- DO NOT INSTALL DIRECTLY BESIDE OR NEAR
WALLPAPER, LAMINATE, VENEER OR ANY SURFACE
THAT HAS NOT BEEN FIRE RATED (the heat will impact
the material, and in some circumstances the glue used for its
application). THIS INCLUDES THE DETAILING/FINISHING
MATERIALS USED ON THE DECORATIVE SURFACES
AROUND THE INSTALLED FIREBOX.
- Be installed into a setting that has a square back – the incorporation of angled backs alters the
aerodynamics of the ame environment and could lead to an unstable ame behaviour
As a general guide we recommend that:
- Any furniture items or ttings directly above or beside the EcoSmart™ Fire installation be deemed
suitable for heat tolerances by their manufacturer e.g Plasma Television Screens
- A heat reective panel made of non combustible material (ideally stainless steel) be installed as the
surround and top of the replace setting to assist in heat distribution
- Any reconstituted materials you wish to use be checked in terms of strength and suitability around such
high temperature variations as some materials will crack – call The Fire Company Pty Ltd for more
information about specic surfaces - Glass or mirrored surfaces near the EcoSmart™ Fire installation
must be toughened
SPACERS: When the XL700 Burner is in position, there is usually an air gap around it.
Do not pack with insulation or other materials, as the air spacers are required for ventilation.
Cut Out
Top Tray
[26.7]
680mm
[6.8]
173mm
[4.8]
123mm
XL700 Burner

© Copyright 2004 - 2010 The Fire Company Pty Ltd - International Patent Pending - Trademark Registered - All Designs Registered. www.ecosmartre.com
Ventilation EcoSmart™ Fires do not require any form of permanent xture or tting, such as a ue for ventilation, a
permanent gas connection or any kind of xed utility for fuel supply.
Denatured Ethanol* is safe to burn indoors without venting, because its main by-products are carbon
dioxide, water steam and heat.
In a house of typical construction, that is, one that is not of unusually tight construction due to heavy
insulation and tight seals against air inltration, an adequate supply of air for combustion and ventilation is
provided through inltration. However, if the heater is used in a small room where less than 5.7m3 [200ft3]
of air space is provided for each 1000 BTU per hour of heater rating (considering the maximum setting),
the door(s) to adjacent room(s) should be kept open or a window to the outside should be opened at
least 25.4mm [1in] to guard against potential build up of indoor air pollution. Do not install or operate in a
bathroom or any other small room.
The room cannot be less than:- 100m3 [3531ft3] per burner.
Efciency The EcoSmart™ Fire is efcient because it is ueless which means all the heat stays in the room rather
than most of it being ued outside as residual emissions.
You can turn the burner on and off as desired, this allows you to control the amount of heat being generated
and the quantity of Denatured Ethanol* used.
Burner XL700
Thermal
Output Net
15.69 Mj/h – 14,869 BTU – 4.36 Kw/hr
Fuel Type Denatured Ethanol
Some fuels are better than others, it’s important to source information on the best fuel in your area from your
local retailer/distributor. Visit www.ecosmartre.com to nd out what Denatured Ethanol is called around the
world.
Thermal
Efciency
Over 90%
Heats on
Average
Over 50m2 OR 538ft2
Fuel
Consumption
0.77 Ltr/hr OR 0.2 Gal/hr
In general 8 Litres OR 2.1 Gal burns for around 9 hours.
Volume Capacity 8 Litres / 2.1 Gal
These values are indicative only and may vary depending on the model purchased, installation and
denatured ethanol used.
NOTE: When the XL Burner reaches 2 Litres OR 1⁄2 Gal of fuel, the ame becomes progressively smaller
and burns for longer.
Model Specications
Burner Kit
XL700
5
7

© Copyright 2004 - 2010 The Fire Company Pty Ltd - International Patent Pending - Trademark Registered - All Designs Registered. www.ecosmartre.com
Burner Kit
XL700 Burner
6
7
[7.6]
193
FRONT VIEW
TOP VIEW
[26.6]
675
[0.6]
16
[4.7]
119
ISOMETRIC VIEW
[27.6]
700
SIDE VIEW
[6.6]
168
[4.7]
119
Scale 1/10
14.07 kg
31.03 lbs
Material
Stainless Steel
Measurements
[inches] = imperial
mm = metric
Weight
14.07kg, [31.03lbs]
Materials
Stainless Steel
Scale 1:10
[7.6]
193
FRONT VIEW
TOP VIEW
[26.6]
675
[0.6]
16
[4.7]
119
ISOMETRIC VIEW
[27.6]
700
SIDE VIEW
[6.6]
168
[4.7]
119
Scale 1/10
14.07 kg
31.03 lbs
Material
Stainless Steel

© Copyright 2004 - 2010 The Fire Company Pty Ltd - International Patent Pending - Trademark Registered - All Designs Registered. www.ecosmartre.com
Burner Kit
XL700
7
7
Conditions of Use
1. For the purposes of this model specication
we refer to the fuel used in the EcoSmart™
Fire as Denatured Ethanol*.
*There are many different names for this
fuel around the world. Please refer to www.
ecosmartre.com for a list of commercially
available fuel names in your country.
Denatured Ethanol* is classied as a
Dangerous Goods Flammable Liquid Class
3, PGII and is regulated by specic standards
and rules. You must familiarise yourself with
the appropriate regulations of your country
in order to safely and legally store, handle,
decant and use this fuel.
The customer warrants to The Fire Company
Pty Ltd that after delivery of their EcoSmart™
Fire and whilst The Fire Company Pty
Ltd retains any interest in the goods or
consigned goods (as the case may be) the
customer shall comply with all applicable
Acts, Regulations and Laws dealing with
the transport, unloading and storage of
Dangerous Goods.
2. Children do not recognize the dangers
that can arise when handling Dangerous
Goods, nor do they recognize the volatility
of ammable liquids when ignited. Please
ensure you keep children at a safe distance
and supervised at all times when operating
the re.
3. Approval from building authorities may
be required. Please ensure you contact the
appropriate parties before installing your
EcoSmart™ Fire.
4. It is a condition of purchase that you obtain
a re extinguisher Ammonium Phosphate
AB:E type. These can be purchased from your
distributor or independently.
Warnings
1. Risk of explosion:
a) Never use any fuel other than the fuels
specically identied for use in the appliance.
Never use gasoline.
b) Never ll the fuel reservoir when it is
operating or still hot.
c) Never ll fuel reservoir in areas where
ammable vapours or gas may be present.
d) Never store or transport the fuel in other
than a metal or plastic container that is:
1. Acceptable for use with the specic fuel.
2. Is in the original container for the alcohol
fuel.
3. Never store fuel in the living space where
the re is situated.
4. Due to high surface temperatures, keep
children, pets, clothing, and furniture away.
The unit is hot while in operation, contact with
the EcoSmart™ Fire may cause skin burns.
5. Risk of indoor air pollution – use
EcoSmart™ Fires only in well-ventilated
areas. People with breathing problems
should consult a physician before using the
appliance.
6. Do not use the EcoSmart™ Fire to heat
or boil water or as a cooking appliance. Do
not throw waste materials or paper into the
EcoSmart™ Fire.
7. EcoSmart™ Fires have not been tested
with an unvented gas log set. To reduce the
risk of re or injury, do not install an unvented
gas log set into this appliance.
8. The EcoSmart™ Fire has not been tested
for use with doors. To reduce the risk of re or
injury, do not install doors.
9. It is recommended that the EcoSmart™
Fire be xed into position to avoid
displacement as per instruction provided with
each model.
10. Do not dismantle the EcoSmart™ Burner.
11. Do not attach any other tank to the
EcoSmart™ Burner.
12. EcoSmart™ Fires must only be operated
using authorised accessories & equipment.
13. Do not obstruct the open/close sliding
mechanism of the EcoSmart™ Burner in any
way as this could result in the jamming/non
functionality of the shut off mechanism.
14. The EcoSmart™ Burner should not be
started if a fault is suspected or when there
appears to be any damage to the burner or its
housing.
15. The use of any tting other than those
available from or recommended by The Fire
Company Pty Ltd for the EcoSmart™ Firebox
and Burner is not permitted.
16. The Fire Company Pty Ltd does not accept
responsibility for any damage which occurs if
the EcoSmart™ Fire is used for purposes other
than those for which it is intended, or if it is
incorrectly operated or repaired by unqualied
persons.
17. The EcoSmart™ Fire is not intended to
operate continuously. To avoid heat expansion
and potential splitting of the timber framework
in Designer Range models please ensure that
the model is allowed to cool down completely
on a regular basis.
If you have any questions regarding any of
the above important safety information please
contact your distributor or The Fire Company
Pty Ltd.
Testing & Compliance
The EcoSmart™ Fire is
manufactured by The Fire Company
Pty Ltd whose quality management
system is certied as being in
conformity with ISO 9001:2008.
The EcoSmart™ Fire Collection has achieved
Swedish Institute for Technical Approval in
Construction (SITAC) approval.
The EcoSmart™ Fire is the rst product of its
kind to have its collection so comprehensively
UL/ULC listed. For the most up to date list
of UL/ULC Listed models and compliance
requirements please contact your local
distributor.
Instructions and specications for the
EcoSmart™ Fire were tested as far as
practicable to a selection of clauses from
AS4553/AG103 – Australian Standard for Gas
Space Heaters (closest comparable product at
the time of invention)
Investigation into applicable standards and
testing platforms for compliance to GS & CE
were held and The Fire Company has gained
a Compliance Verication Declaration from
Globalnorm GmbH.
Q U A LITY
A SSU R ED
ISO 9001:2008
D N V Certification Pty Ltd
Models from the EcoSmart™ Fire Collection have achieved the following certication and approvals:
Please contact The Fire Company Pty Ltd should you require data on the certications applicable to specic models.
Table of contents
Popular Burner manuals by other brands

Enertech
Enertech Nu-way MOL795 T3N 273 3R Installation and maintenance instruction

RCS
RCS RSB3A Installation and operating instructions

RT Champ
RT Champ KB 5 manual

Beckett
Beckett AFG Oil Burner instruction manual

Riello
Riello RL 250 MZ Installation, use and maintenance instructions

Riello
Riello RS 34/E MZ Installation, use and maintenance instructions

Weishaupt
Weishaupt WL40Z-A 1LN manual

Cuenod
Cuenod NC12 operating instructions

Riello
Riello 20045452 Installation, use and maintenance instructions

CK WORLDWIDE
CK WORLDWIDE CK9 FLEX Series manual

Riello Burners
Riello Burners Gulliver RG1R Installation, use and maintenance instructions

Riello
Riello RS BLU Series Installation, use and maintenance instructions