EcoSolaris TW 12 User manual


2
SAFETY PRECAUTIONS
Warning ............................................................................................................................... 3
Caution ..................................................................................................................................3
INSTALLATION INSTRUCTIONS
Selecting installation place. ...................................................................................4
Packing list .........................................................................................................................5
Indoor unit installation. .............................................................................................6
Outdoor unit installation ..........................................................................................8
REFRIGERANT PIPE CONNECTION
Refrigerant pipe connection .................................................................................9
ELECTRICAL WORK
Electrical work .................................................................................................................10
Installation of the solar photovoltaic system .............................................13
Panel Grounding
Grounding Principles. ................................................................................................24
AIR PURGING
Air purging with vacuum pump .........................................................................27
TEST RUNNING
Test running ......................................................................................................................28
Inside you will find many helpful hints on how to install and test the air conditioner properly.
CAUTION
Contact an authorised service technician for repair or maintenance of this unit. Contact an
authorised installer for installation of this unit.
The air conditioner is not intended for use by young children or infirmed persons without supervision.
Young children should be supervised to ensure that they do not play with the air conditioner.
If the power cord is to be replaced, replacement work shall be performed by authorised personnel
only. Installation work must be performed in accordance with the national wiring Standards by autho-
rised personnel only.
Table of Content

3
Ecosolaris Solar Heat Pump Installation Manual
SAFETY PRECAUTIONS
• Read the follow SAFETY PRECAUTIONS carefully before installation.
• Installation must be performed in accordance with the requirement of NEC and CEC by authorized per-
sonnel only.
• Incorrect installation due to ignoring of the instruction will cause harm or damage.
The seriousness is classified by the following indications.
The items to be followed are classified by the symbols:
Engage dealer or specialist for installation. If installation done by the user is defective, it will cause wa-
ter leakage, electrical shock or fire.
2) Install according to this installation instructions strictly. If installation is defective, it will cause water
leakage, electrical shock or fire.
3) Use the attached accessories parts and specified parts for installation. otherwise, it will cause the set
to fall, water leakage, electrical shock or fire.
4) Install at a strong and firm location which is able to withstand the set s weight. If the strength is not
enough or installation is not properly done, the set will drop and cause injury.
5) For electrical work, follow the local national wiring standard, regulation and this installation instruc-
tions. An independent circuit and single outlet must be used. If electrical circuit capacity is not enough
or defect found in electrical work, it will cause electrical shock or fire.
6) Use the specified cable and connect tightly and clamp the cable so that no external force will be act-
ed on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
7) Wiring routing must be properly arranged so that control board cover is fixed properly. If control
board cover is not fixed perfectly, it will cause heat-up at connection point of terminal, fire or electrical
shock.
8) When carrying out piping connection, take care not to let air substances other than the specified
refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure
in the refrigeration cycle, explosion and injury.
9) Do not modify the length of the power supply cord or use of extension cord, and do not share the
single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.
1) This equipment must be earthed and installed with earth leakage current breaker. It may cause elec-
trical shock if grounding is not perfect.
2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and
accumulates at surrounding of the unit, it may cause fire.
3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water
may enter the room and damage the furniture.

4
INSTALLATION INSTRUCTIONS
Selecting installation place
Select an installation location which is rigid and strong enough to support or hold the unit, and select
a location for easy maintenance. Read completely, then follow step by step.
Indoor Unit
• Do not expose the indoor unit to heat or steam.
• Select a place where there are no obstacles in front or around
the unit.
• Make sure that condensation drainage can be conveniently
routed away.
• Do not install near a doorway.
• Ensure the spaces indicated by arrows from the wall ceiling or
other obstacles.
• A place where noise prevention is taken into consideration. A
place 1m or more to TV or radio instrument.
• A place where air circulation in the room is good.
• There should not be any direct sunlight. Otherwise, the sun will
fade the plastic cabinet and affect its appearance. If unavoid-
able, sunlight prevention should be taken into consideration.
Outdoor unit
• If an awning is built over the outdoor unit to prevent direct sun-
light or rain exposure, make sure that heat radiation from the
condenser is not restricted.
• Keep the spaces indicated by arrows from wall or other obsta-
cles.
• Do not place animals and plants in the path of the air inlet or
outlet.
• Take the air conditioner weight into account and select a place
where noise, vibration and hot air discharged will not be an is-
sue.
• Do not install in a place full of machine oil or sulfide gas such as
hot-spring resort.
• Do not install in a saline place such as coast.
• Do not install in a place where there are high frequency ma-
chines such as wireless equipment, welding machine or med-
ical facility.
•
Rooftop installation:
• If the outdoor unit is installed on a roof structure, be sure to
level the unit.
• Ensure the roof structure and anchoring method are adequate
for the unit location.
• Consult local codes regarding rooftop mounting.
Tools needed for installation
• Level gauge
• Screwdriver
• Electric drill,Hole core drill ( 65mm/2.6in)
• Flaring tool set
• Specified torque wrenches: 1.8kgf.m,
• 4.2kgf.m, 5.5kgf.m, 6.6kgf.m
(different depending on model No.)
• Spanner (half union)
• Hexagonal wrench (4mm/0.157in)
• Gas-leak detector
• Vacuum pump
• Gauge manifold
• Users manual
• Thermometer
• Multimeter
• Pipe cutter
• Measuring tape

5
Ecosolaris Solar Heat Pump Installation Manual
INSTALLATION INSTRUCTIONS
Packing list
Packing list of the indoor unit
N0. Name Quantity Unit
1 Indoor Unit 1 Set
2 Remote Controller 1 PC
3 Batteries(AA) 2 PC
4 Instructrions 1 Set
5 Drain Pipe 1 PC
Packing list of the outdoor unit
No. Name Quantity Unit
1 Outdoor Unit 1 Set
2 Connecting pipe 2 PC
3 Plastic Strap 1 Roll
4 Pipe Protection Ring 1 PC
5 Luting (putty) 1 PACKET
NOTE: All accessories shall be subject to actual packaging material, and if there is any difference, please understand.
CAUTION
• Use a stud finder to locate studs to pre-
vent unnecessary damage to the wall.
• A, B, and C directions should be free
from obstructions
• Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
• A, B, and C directions should be free from
obstructions

6
Indoor unit installation
1. The wall for installation of the indoor unit shall be
hard and firm, so as to prevent vibration.
2. Use the “+” type screw to fasten the peg board,
horizontally mount the peg board on the wall, and
ensure the lateral horizontal and longitudinal vertical.
3. Pull the peg board by hand after the installation, to
confirm whether it is solid.
Notes:
Fit the Installation Plate and drill holes
in the wall according to the wall structure
and corresponding mounting points on the
installation plate The installation plate is
different according to the models.
Drill a hole in the wall
1). Make a hole with an electric hammer or a
water drill at the predetermined position on
the wall for piping, which shall slant outwardly
by 5°-10°.
2).To protect the piping and the cables from
being damaged running through the wall,
and from the rodents that may inhabit in
the hollow wall, a pipe protecting ring shall
be installed and sealed with putty.
Note: Usually, the wall hole is Φ60mm~Φ80mm.
Avoid pre-buried power wire and hard wall
when making the hole.
INSTALLATION INSTRUCTIONS

7
Ecosolaris Solar Heat Pump Installation Manual
3. Connective Pipe and Drainage
Installation
1. Run the drain hose sloping downward. Do not
install the drain hose as illustrated in Fig .7.
2. When connecting extension drain hose, insulate
the connecting part of extension drain hose with
a shield pipe, do not let the drain hose slack.
Connective pipe installation
1. For the left-hand and right-hand piping,
remove the pipe cover from the side panel.
2. For the right back and left back piping.
install the piping as shown.
NOTE: For 12K/18k model, there are two side drain-
age structure design.
For both sides drainage structure, it can be choos-
en forright, left or both sides drainage connection.
If choosing both sides drainage connection, anoth-
er proper drain hose is needed as there is only one
drain hose offered by factory.
The connection of the drain hose is supposed to be
done by qualified installer in case of water leakage.
3. Bundle the tubing, connecting cable, and drain
hose with tape securely, evenly as shown in Figure
on the right.
Because the condensed water from rear of the
indoor unit is gathered in ponding box and is piped
out of room. Do not put anything else in the box.
4. Indoor unit installation
1. Pass the piping through the hole in the wall.
2. Put the upper claw at the back of the indoor unit
on the upper hook of the installation plate, move
the indoor unit from side to side to see that it is
securely hooked (see Fig.9 & Fig.10).
3. Piping can easily be made by lifting the
indoor unit with a cushioning material between
the indoor unit and the wall. Get it out after finish
piping .
4. Push the lower part of the indoor unit up on the
wall, then move the indoor unit from side to side,
up and down to check if it is hooked securely.
INSTALLATION INSTRUCTIONS

8
5. Piping and wrapping
Bundle the tubing, connecting cable, and drain
hose with tape securely, evenly as shown in
Fig.12
• Because the condensed water from rear of the
indoor unit is gathered in ponding box and is
piped out of room. Do not put anything else in
the box.
CAUTION
• Connect the indoor unit first, then the outdoor
unit.
• Do not allow the piping to let out from the back
of the indoor unit.
• Be careful not to let the drain hose slack.
• Heat insulated both of the auxiliary piping.
• Be sure that the drain hose is located at the
lowest side of the bundle. Locating at the upper
side can cause drain pan to overflow inside the
unit.
• Never intercross nor intertwist the power wire
with any other wiring.
• Run the drain hose sloped downward to drain
out the condensed water smoothly.
Outdoor unit installation
Outdoor installation precaution
• Install the outdoor unit on a rigid base to pre-
vent increasing noise level and vibration.
• Determine the air outlet direction where the
discharged air is not blocked. In the case that
the installation place is exposed to strong wind
such as a seaside, make sure the fan operating
properly by putting the unit lengthwise along
the wall or using a dust or shield plates.
• Specially in windy area, install the unit to pre-
vent the admission of wind. If need suspending
installation, the installation bracket should ac-
cord with technique requirement in the instal-
lation bracket diagram.
• The installation wall should be solid brick, con-
crete or the same intensity construction, or ac-
tions to reinforce, damping supporting should
be taken. The connection between bracket and
wall, bracket and the air conditioner should be
firm, stable and reliable.
• Be sure there is no obstacle which block radiat-
ing air.
INSTALLATION INSTRUCTIONS

9
Ecosolaris Solar Heat Pump Installation Manual
Dimension drawing of outdoor unit installation
Installation outdoor unit bolt
Drain joint installation
• If a drain elbow is used, the unit should be placed on a
stand which is taller than 3cm.
• Fit the seal into the drain elbow, then insert the drain joint
into the base pan hole of outdoor unit, rotate 90 to securely
assemble them. Connecting the drain joint with an exten-
sion drain hose (Locally purchased), in case of the water
draining off the outdoor unit during the heating mode.
Refrigerant pipe connection
1. Flaring work
Main cause for refrigerant leakage is due to defect in the flaring
work. Carry out correct flaring work using the following proce-
dure:
A: Cut the pipes and the cable.
1. Use the piping kit accessory or pipes purchased locally.
2. Measure the distance between the indoor and the outdoor
unit.
3. Cut the pipes a little longer than the measured distance.
4. Cut the cable 1.5m longer than the pipe length.
B: Burr removal
1. Completely remove all burrs from the cut cross section of
pipe/tube.
2. Put the end of the copper tube/pipe in a downward direc-
tion as you remove burrs in order to avoid dropping burrs
into the tubing.
REFRIGERANT PIPE CONNECTION

10
ELECTRICAL WORK
C: Putting nut on
Remove flare nuts attached to indoor and
outdoor unit, then put them on pipe/tube having
completed burr removal.(not possible to put them
on after flaring work)
D: Flaring work
Firmly hold copper pipe in a die in the dimension
shown in the table below.
Tightening Connection
• Align the center of the pipes.
• Sufficiently tighten the flare nut with fingers,
and then tightenit with a spanner and torque
wrench as shown in Fig.20 & 21.
Caution
Excessive torque can break nut depending on in-
stallation conditions.
Electrical work
Electric safety regulations for the initial Installation
1. If there is serious safety problem about the power supply, the technicians should refuse to install the air
conditioner and explain to the client until the problem is solved.
2. Power voltage should be in the range of 90%~110%of rated voltage.
3. The surge protector and main power switch with a 1.5 times capacity of Max. Current of the unit should be
installed in power circuit. Ensure the air conditioner is grounded well.
4. The appliance shall be installed in accordance with national wiring regulations. Do not operate your air
conditioner in a wet room such as a bathroom or laundry room.
5. An all-pole disconnection device which has at least 3mm clearances in all poles, and have a leakage cur-
rent that may exceed 10mA, the residual current device(RCD) having a rated residual operating current not
exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance with the wiring
rules.
6. For the unit adopts auxiliary electric heater, keep at least 1 meter away from the nearest combustible mate-
rials.
7. According to the attached Electrical Connection Diagram located on the panel of the indoor & outdoor unit
to connect the wire.
8. All wiring must comply with local and national electrical codes and be installed by qualified and skilled elec-
tricians.
9. An individual branch circuit and single receptacle used only for this air conditioner must be available. See
the following table for suggested wire sizes and fuse specifications:

11
Ecosolaris Solar Heat Pump Installation Manual
Suggest Minimum Wire Size
(AWG: American Wire Gage ):
NOTE:
• The wire size of power supply cord and intercon-
nected wire and the current of the fuse or switch
are determined by the maximum current indicat-
ed on the nameplate which located on the side
panel of the unit. Please refer to the nameplate
before selecting the wire size, fuse or switch.
• The controller of the air conditioner designed with
a fuse protection function under abnormal con-
ditions, the specifications of the fuse have print-
ed on the circuit board, such as: T3.15A/250VAC,
T5A/250VAC, etc.
Connect the cable to the indoor unit
NOTE: Before performing any electrical
work, turn off the main power to the system.
1. The inside and outside connecting cable can be
connected without removing the front grille.
2. The indoor power cord type is H05VV-F or
H05V2V2-F, the outdoor power cord and intercon-
nected cord type is H07RN-F.
3. Lift the indoor unit panel up, remove the electrical
box cover by loosening the screw.
4. Ensure the colour of wires of outdoor unit and the
terminal Nos. are the same to the indoor’s respective-
ly.
5. Wrap those cables not connected with terminals
with insulation !apes, so that they will not touch
any electrical components. Secure the cable onto the
control board with the cord clamp.
Appliance Amps AWG Wire Size
10 18
13 16
18 14
25 12
30 10
ELECTRICAL WORK

12
ELECTRICAL WORK
Connect the cable to the outdoor unit
1. Remove the cover control from the unit by loos-
ening the screws. See Fig.23.
2. Dismount caps on the conduit pane
3. Temporarily mount the conduit tubes(not includ-
ed)on the conduit panel.
4. Properly connect both the power supply and low
voltage lines to the corresponding terminals on
the terminal bloc
5. Ground the unit in accordance with local codes.
6. Be sure to size each wire allowing several inches
longer than the required length for wiring.
7. Use lock nuts to secure the conduit tubes.
NOTE:
• Wrong wiring may cause spare parts malfunction.
• After the cable fixed, make sure there should be a free space between the connection and
connection and fixing place on the lead wire.
• The rated voltage of solar power should between 100~ 300V and the rated current of solar
power should be less than 15A.

13
Ecosolaris Solar Heat Pump Installation Manual
ELECTRICAL WORK
Installation of the solar photovoltaic system
• This guide contains information regarding the installation and safe handling of solar photovoltaic
module. All instructions should be read and understood before attempting to install. If there is
any question, please contact our sales department for further explanation. The installer should
conform to all the safety precautions listed in this guide when installing the module. Local codes
should also be followed in such installations.
• This manual describes several typical systems of solar photovoltaic, but does not involve the
specific structures and installation procedures of the installation. Please consult the supplier for
the information of the following assemblys:
a) the specifications of the solar photovoltaic system;
b) cable material
c) connecting components
d) bracket and support
e) supporting parts .
• Before installing a solar photovoltaic system, the installer should become famil iar with the
mechanical and electrical requirement for such a system. Keep this guide in a safe place for future
reference (care and maintenance) and in case of sale or disposal of the module at the end of its
useful life.
General
• Installing solar photovoltatic systems may require specialized skills and knowledge. Installation
should be performed only by qualified persons.
• All modules come with a permanently attached junction box and #12 AWG teminated in
Muti-contact (MC4) PV-KBT4 (female) or PV-KST4 (male) connectors.
• The installer should assume the risk of all injury that might occur during installation, including,
without limitation, the risk of electric shock.
The solar photovoltatic electrical energy production system must comply with the following
• table for suggested current and vol tage specifications:
• One individual module may generate DC voltages greater than 30 volts when exposed to direct sunlight.
Contact with a DC voltage of 30V or more is potentially hazardous. Electrical joints such as the wire termi-
nal will cause sparks, burning or deadly electric shock. Please do not touch such terminals directly under
any circumstances.

14
ELECTRICAL WORK
• When disconnecting wires from a photovoltaic module that is exposed to sunlight, an electric arc may re-
sult. Such arcs may cause burns, combustion and may otherwise create problems. Therefore, be extremely
careful!
• Photovoltaic solar modules convert light energy to direct-current electrical energy. They are designed for
outdoor use. Modules may be ground mounted , mounted on rooftops, vehicles, or boats. Proper design of
support structures is the responsibility of the system designer and installer. Proper use of mounting holes
is suggested in a following paragraph.
• Do not attempt to diassemble the module, and do not remove any attached nameplates or components.
• Do not apply paint or adhesive to module top surface.
• Do not use mirrors or other magnifiers to artificially concentrate sunlight on the module.
• When installing the system, abide with all local, regional and national statutory regulations.
• Obtain a building permit where necessary. Abide with any local and national regulations when mounting
on vehicles or boats.
Safety precaution for installing a solar photovoltaic system
• When installing the solar modules or repairing the air conditioner, ensure the circuit breaker between
the solar panel and the outdoor unit is in the “OFF” state(push the switch to “OFF” position). During
normal operation , the circuit breaker should be in the “ON” state(push the switch to “ON” position)

15
Ecosolaris Solar Heat Pump Installation Manual
ELECTRICAL WORK
• Solar modules produce electrical energy when light strikes on their front surface. The DC voltage will
exceed 30V. If modules are connected in series, the total voltage is equal to the sum of the individual
module voltages. If modules are connected in parallel, the total current is equal to the sum of individual
module currents.
Connect the panels in Series
• Keep children well away from the system while transporting and installing mechanical and
electrical components.
• Completely cover the module with an opaque material during installation to keep electricity from being
generated. Do not touch the components or the end of live wires. However, if appropriate protections
has been taken during the operation according to the local safety regulations, the above requirement is
unnecessary.
• Do not wear metallic rings, watchbands, ear, nose, lip rings or other metallic devices while installing or
troubleshooting photovoltaic systems.
• Use only insulated tools that are approved for working on electrical installations

16
ELECTRICAL WORK
• When performing installation in dry conditions, please ensure the tools used in the dry.
• Abide with the safety regulations for all other components used in the system, including wiring and ca-
bles, connectors, charging regulators, inverters, storage batteries and rechargeable batteries, etc.
• Use only equipment, connectors, wiring and support frames suitable for use in a solar electric systems.
Always use the same type of module within a particular photovoltaic system.
• The module frame must be properly grounded. The grounding wire must be properly fastened to the
module frame to assure good electrical contact. Use the recommended type, or an equivalent, connec-
tor for this wire.
• Under mormal outdoor conditions the module will produce current and voltages that are different than
those listed in the date sheet. Data sheet values are values expected at standard test conditions. Accord-
ingly, during system design, values of short-circuit current (Isc) and open-circuit voltage (Voc) marked
on UL series modules should be multiplied by a factor of 1.25 when determining component voltage
ratings, conductor ampacity, fuse size and size of controls connected to the module or system output.
• The hole in the back of the module frame is used to drain the water, ensure not to be blocked.
Mechanical installation
1. Selecting installation place
• Select a suitable place for installation of the module.The module should not be shaded at any time of
the day.
• The module should be facing due south in northern latitudes and due north in southern latitudes for
best power production.
• For detailed information on the best elevation tilt angle for the installation, please consult with the solar
photovoltatic system supplier.
• Do not use module near the place where the flammable gas may be generated or collected

17
Ecosolaris Solar Heat Pump Installation Manual
ELECTRICAL WORK
2. Selecting the proper support frame
• Always observe the instructions and safety precautions included with the support frame to be used with
the module.
• Never attempt to drill holes in the glass surface of the module, it will void the warranty.
• Do not drill additional mounting holes in the frame of the module, it will void the warranty.
• Modules must be securely attached to the mounting structure using four mounting points for normal
installation. If additional wind or snowloads are considerated for the installation, additional mounting
points are also used.
• The support frame must be made of durable, corrosion-resistant and UV-resistant material.
• The heat expansion and cold contraction of the support frame should have no affection to its usage and
performance.
3. Ground mount
• Select the height of the mounting system to prevent the lowest edge of the module from being cov-
ered by snow for a long time in winter in areas that experience heavy snowfalls. In addition, assure
the lowest portion of the module is placed high enough so that it is not shaded by plants or trees or
damaged by sand and stone driven by wind.

18
ELECTRICAL WORK
4. Roof mount
• When installing a module on a roof or building, ensure that it is securely fastened and cannot fall as a
result of wind or snow loads.
• Provide adequate ventilation under a module for cooling (5cm minimum air space between module
and mounting surface).
• When installing module on a roof, ensure that the roof construction is suitable. In addition, any roof pen-
etration required to mount the module must properly sealed to prevent leaks.
In some cases, a special support frame may be necessary.
• The roof installation of solar modules may affect the fireproofing of the house construction, so it is
necessary to use an earth ground fault circuit breaker. Any unproper installation may cause accidental
injuries.
• When installing the module on a roof or building, do so in calm winds. Installing a module during strong
winds may cause accidents.
5. Pole mount
• When installing a module on a pole, choose a pole and module mounting structure that will withstand
anticipated winds for the area. The pole must have a solid foundation.

19
Ecosolaris Solar Heat Pump Installation Manual
ELECTRICAL WORK
6. General installation
• Module mounting must use the pre-drilled mounting holes in the frame.
• The most common mounting is achieved by mounting the module using the four symmetry points
closed to the inner side on the module frame.
• If excessive wind or snow loads are expected, all eight mounting holes must be used.
• If you want to install the module without using the pre-drilled mounting holes in the frame, please con-
sult with the supplier.
• Do not install in the rainy weather, it may cause insulation failure due to moisture, and there is a risk of
electric shock.
• Do not attempt to lift the module by grasping the module,s junction box while moving.
• Do not stand or step on module.
• Do not throw the module or drop any thing on the module.
• To avoid glass breakage, do not place any heavy objects on the module. Do not set the module down
hard on any surface.
• Inappropriate transport and installation may break the glass of the module.

20
ELECTRICAL WORK
Electrical Installation
1.General installation
• Do not use modules of different configurations in the same system.
• The solar photovolatic array consists of modules connected in series, no more than 10 pcs 260W mod-
ules can be used in series. Modules in series can increase the output voltage of the solar PV system, es-
pecially for applications requiring high volatge, low currents. If modules are connected in series, the total
voltage should be less than 300V DC.
• If modules used in the solar photovolatic system are not the specified brand of the manufacturer, it
must comply with the electrical requ irement. The cross section area of cable and the capacity of con-
nector must be selected to suit the maximum system short circuit current, Otherwise the cable and the
connector will be overheated under large current.
• Any hardware used must be compatible with the mounting structure material to avoid galvanic corro-
sion MC-4 connector is the recommended connector and the recommended system wires size is AWG12
• Installation Sketch as Fig. 49
This manual suits for next models
1
Table of contents
Popular Air Conditioner manuals by other brands

Mitsubishi Electric
Mitsubishi Electric MSZ-LN18VG2W-E1 Service manual

Mitsubishi Electric
Mitsubishi Electric PKH-2FKHA Operation manual

Samsung
Samsung AS09HPB Service manual

Mitsubishi Electric
Mitsubishi Electric MSZ-GS30NA2 installation manual

Zokop
Zokop YPS5-12C user manual

Fujitsu General
Fujitsu General ASH9LSBCW Service manual