Ecox RG51M/BGE-IN User manual

EADM
EADM
OWNER´S MANUAL
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
Thank you for purchasing this ecox product
Before using this machine, please read this manual and retain it for
future reference.

2
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EADM
REMOTE CONTROLLER SPECIFICATION
PERFORMANCE FEATURES
FEATURES OF THE REMOTE CONTROLLER BUTTONS
INDICATORS ON DISPLAY PANEL
OPERATING THE REMOTE CONTROLLER
WARNING
CONTENTS
3
3
4
6
7
11

3
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EADM
REMOTE CONTROLLER SPECIFICATIONS
PERFORMANCE FEATURES
MODELO R51M/(C)E, R51M/BG(C)E, RG51M2/(C)E,
RG51A/(C)E, RG51M3/(C)E, RG51M3/BG(C)E,
RG51M8/(C)E, RG51M9/(C)E, RG51M/BGE-IN
Rated Voltage 3.0V (Dry batteries LR03 X 2)
Transmission Distance 8m
Environment -5º C~ 60º C / 23º F ~ 140º F.
1
2
3
4
Operating Mode: AUTO, COOL, DRY, HEAT and FAN.
Timer Setting Function in 24 hours.
Indoor Setting Temperature Range: 17º C~ 30º C / 63º F ~ 86 º F.
Full function of LCD (Liquid Crystal Display).

4
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EADM
FEATURES OF REMOTE CONTROLLER BUTTONS
1
2
3
TEMP Button : Push this button to decrease the indoor temperature setting.
TEMP Button : Push this button to increase the indoor temperature setting.
MODE Selection Button: Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
FIG. 1
Note:
*: Indicates optional buttons.
14 * and 15* buttons are not
available for models RG51M2/
(C)E.
7*, 14* and 15* buttons are
not available for models
RG51M3/(C)E and RG51M3/
BG(C)E.
15* button is not available
for models R51M/(C)E, R51M/
BGE, R51M/BGE-IN.
4*, 6*, 7*, 14*, 15* buttons
are not available for models
RG51M9/(C)E.
6*, 7*, 14*, 15* buttons are
not available for models
RG51M8/(C)E.
15
CLEAN
AIR

5
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EADM
6
7
8
9
10
11
NOTE
4
5
Please do not select HEAT mode lithe machine you purchased is cooling only type. Heat
mode is not supported by the cooling only appliance.
SWING Button: Push this switch button to activate auto swing feature of the
horizontal louver. Push it again to stop.
RESET Button: When you press the recessed RESET button, all current settings are
cancelled and the control will return to the initial settings.
AIR DIRECTION Button: Press this button to change the swing angle of the louver.
The swing angle of the louver is 6º for each press. When the louver swing at a certain
angle which would aect the cooling and heating eect of the air conditioner, it
would automatically change the swing direction. No symbol will appear in the
display area when press this button. (Not applicable to units without this function).
LED DISPLAY Button: Press this button to clear the digit display in the air
conditioner, press it again to to activate it (Not available for the units without LED
display window).
FAN SPEED Button: Used to select the Fan Speed in four steps AUTO, LOW, MED or
HIGH. Each time the button is pressed, the fan speed mode is shifted.
ON/OFF Button: Push this button to start operation, push the button again to stop
operation.
TIMER ON Button: Press this button to initiate the auto-on time sequence. Each
press will increase the auto-timed setting in 30 minutes increments. When the
setting time displays 10, each press will increase the auto-timed setting 60 minutes
increments. To cancel the auto-timed program, simply adjust the auto-on time to
0.0.
SLEEP Button: Press this button to go into the Energy-Saving operation mode.
Press it again to cancel. This function is only can be used on COOL, HEAT and AUTO
mode and maintain the most comfortable temperature for you.
TIMER OFF Button: Press this button to initiate the auto-o time sequence. Each
press will increase the auto-timed setting in 30 minutes increments. When the
setting time displays 10, each press will increase the auto-timed setting 60 minutes
increments. To cancel the auto-timed program, simply adjust the auto-o time to
0.0.
LOCK Button: When you press the recessed LOCK button, all current settings are
locked in and the remote controller does not accept any operation except that of
the LOCK. Press again to cancel the LOCK mode.
12
13

6
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EADM
1
2
3
14
15
TURBO Button: Push this button to activate/cancel the Turbo function which
enables the unit to reach the preset temperature in the shortest time. On cooling
mode, the unit will be low strong cooling air with super high fan speed. On heating
mode (applicable to the unit adopts PTC only), the PTC will bring fast heating
operation.
CLEAN AIR Button (on some models): When push this button, the Ionizer or Plasma
Dust Collector (depending on models) is energized and will help to remove pollen
and impurities from the air.
INDICATOR ON DISPLAY PANEL
DISPLAY PANEL
FIG. 2
DIGITAL DISPLAY
TRANSMITION
INDICATOR
OPERATION MODE
INDICATOR
LOCK INDICATOR
FAN SPEED INDICATOR
OPERATION MODE
INDICATOR
ON / OFF
INDICATOR
TIMER DISPLAY
INDICATOR
DIGITAL DISPLAY Area: This area will show the set temperature and, if in the TIMER
mode, will show the ON and OFF settings of the TIMER. If in the FAN mode, nothing
is appeared.
TRANSMISSION Indicator: This Indicator ashes one time when remote controller
transmits signals to the indoor unit.
ON/OFF Indicator: This symbol appears when the unit is turned on by the remote
controller, and disappears when the unit is turned o.

7
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EADM
OPERATION MODE Indicator: When press the MODE button, it shows the current
operating mode - “AUTO", "COOL”, "DRY" "HEAT"(Cooling only model without) or
"FAN" mode.
LOCK Indicator: LOCK display is displayed by pushing the LOCK button Push the
LOCK button to clear display.
TIMER DISPLAY Indicator: This display area shows the settings of the TIMER. That
is, if only the starting time of operation is set, it will display the TIMER ON. If only the
turning o time of operation is set, it will display the TIMER OFF. If both operations
are set, it will show TIMER ON/OFF which indicates you have chosen to set both the
starting time and o time.
FAN SPEED Indicator: Press the FAN SPEED button to select the desired fan speed
setting (Auto-Low-Med-High). You selection will be displayed in the LCD Window
except the Auto fan speed.
All signs shown in the Fig.2, is for the purpose of clear presentation. But during the actual
operation only the relative functional signs are shown on the display panel.
OPERATING THE REMOTE CONTROLLER
INSTALL/REPLACE BATTERIES
The Remote Controller uses two alkaline dry batteries (LR03X2).
To install the batteries, slide the back cover of the battery compartment and install
the batteries according the direction (+and -) shown on the Remote Controller.
To replace the old batteries, use the same method as mentioned above.
1
2
4
5
6
7
NOTE

8
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EADM
AUTOMATIC OPERATION
1
2
Use the MODE button to select AUTO.
Push the TEMP button to set the desired room temperature. The most comfortable
temperature settings are between 21º C to 28º C / 69º F ~ 82º F.
Push the ON/OFF button to start the air conditioner. The OPERATION lamp on the
display panel of the indoor unit lights. The FAN SPEED is automatically set and there
are no fan speed indicators shown on the display panel of the remote controller.
Push the ON/OFF button again to stop the unit operation.
3
4
1
2
In the AUTO mode, the air conditioner can logically choose the mode of COOL, FAN and
HEAT by sensing the dierence between tire actual ambient room temperature and the set
temperature on the remote controller.
If the AUTO mode is not comfortable for you, the desired mode can be selected manually.
NOTE
When replacing batteries, do not use old batteries or a dierent type battery. This may
cause the remote control to malfunction.
If you do not use the remote controller for several weeks remove the batteries. Otherwise
battery leakage may damage the remote controller.
The average battery life under normal use is about 6 months.
Replace the batteries when there is no answering beep from the indoor unit or if the
Transmission Indicator light fails to light.
Do not dispose batteries as unsorted municipal waste. Collection of such waste
separately for special treatment is necessary.
1
2
3
4
5
NOTE

9
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EADM
COOL / HEAT (COOLING ONLY MODEL WITHOUT) AND FAN OPERATION
1
2
3
4
If the AUTO mode is not comfortable, you may manually over-ride the settings by
using COOL, HEAT or FAN modes.
Push the TEMP button to set the desired room temperature. When in COOLING
mode, the most comfortable settings are 21º C / 69º F or above. When in HEATING
mode, the most comfortable settings are 28º C / 82º F or below.
Push the FAN SPEED to select the FAN mode of AUTO, HIGH, MED or LOW.
Push the ON/OFF button, the operation lamp lights and the air conditioner start to
operate as your settings. Push the ON/OFF button again to stop this unit operation.
DRY OPERATION
Push the MODE button to select DRY.
Push the TEMP button to set the desired temperature from 17º C to 30º C / 63º F
~ 86 º F.
Push the ON/OFF button, the OPERATION lamp lights and the air conditioner starts
to operate in DRY mode at LOW fan speed. Push the ON/OFF button again to stop
this unit operation.
Due to the dierence of the set temperature of the unit and the actual indoor
temperature, the Air Conditioner when in DRY mode will automatically operate many
times without running the COOL end FAN mode.
1
2
3
The FAN mode cannot be used to control the temperature. While in this mode, only steps
1, 3 and 4 may be performed.
NOTE
NOTE

10
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EADM
TIMER OPERATION
Push TIMER ON button to set the auto-on tome and TIMER OFF button to set the
auto-o time.
To set the starting time.
Push the TIMER ON button, then the remote controller shows TIMER ON, the last
set time for the starting operation and the signal "h" will be shown on the DIGITAL
DISPLAY area. You are now ready to reset the time to START the operation.
Push the TIMER ON button again to set desired unit start time.
After setting the TIMER ON, there will be a one-half second delay before the remote
controller transmits the signal to the air conditioner. The after approximately another
2 seconds, the signal "h" disappears and the set temperature will re-appear on the
digital display.
To set the stopping time.
Push the TIMER OFF button and the remote controller will show TIMER OFF, the last
set time for the stopping operation and the signal "h" will be shown on the DIGITAL
DISPLAY area. You are now ready to reset the time of the STOP operation.
Push the TIMER OFF button again to set the time you want to stop the operation.
After setting the TIMER OFF, there will be a one-half second delay before the remote
controller transmits the signal to the air conditioner. Then, after approximately
another 2 seconds, the signal "h" disappears and the set temperature will re-appear
on the digital display.
Set the starling & stopping time.
1
2
3
1.1
1.2
1.3
2.1
2.2
2.3
FIG. 3
DISPLAY PANEL
DIGITAL DISPLAY
TRANSMITION
INDICATOR
OPERATION MODE
INDICATOR
LOCK INDICATOR
FAN SPEED INDICATOR
OPERATION MODE
INDICATOR
ON / OFF
INDICATOR
TIMER DISPLAY
INDICATOR

11
REMOTE CONTROLLER
SPLIT AIR CONDITIONER
EADM
Push the TIMER ON button, the remote controller will show TIMER ON, the last set
time for START operation and the signal "h" will be shown on the DIGITAL display
area. You are now ready to readjust the TIMER ON to start the operation.
Push the TIMER ON button again to set the time you want to start the operation.
Push the TIMER OFF button, the remote controller will show TIMER OFF, the last set
time for STOP operation and the signal "h" will be shown on the DIGITAL display
area. You are now ready to reset the time to STOP operation.
Push the TIMER OFF button again to set the lime you want to & stop the operation.
After setting the TIMER, there will be a one-half second delay before the remote
controller transmits the signal to the Air Conditioner. Then, after approximately
another 2 seconds, the signal "h" disappears and the set temperature will re-appear
on the digital display.
The setting time is relative time. That is the time set is based on the delay of the current
time.
3.1
3.2
3.3
3.4
3.5
Be sure there are no obstacles between the remote controller and the receiver of
indoor unit otherwise the air conditioner will not work.
Keep the Remote Controller away from any liquids.
Protect the remote controller from the high temperatures and exposure to radiation.
Keep the indoor receiver out of direct sunlight or the Air Conditioner may
malfunction.
Keep Remote Controller away from EMI (Electro-Magnetic Interference) supplied by
other household appliances.
1
2
3
4
5
WARNING
Change the TIMER
To change the TIMER ON/OFF time, just press the corresponding TIMER button
and reset the time.
To cancel the TIMER ON/OFF setting, just adjust the TIMER time to 0:00.
NOTE

This manual suits for next models
16
Table of contents
Other Ecox Remote Control manuals