Ediseja 21 CMU 200 / HACx2 . 485x1 . FOTx39 - 12 User manual

CMU 200 - User manual
Content
1 PREFACE.......................................................................................................3
2 CMU 200 SYSTEM.........................................................................................6
2.1 DESCRIPTION..................................................................................................................... 6
2.1.1 SOFTWARE...................................................................................................................... 6
2.1.2 HARDWARE...................................................................................................................... 6
3 DESCRIPTION...............................................................................................7
3.1 DESCRIPTION..................................................................................................................... 7
3.2 APPERANCE........................................................................................................................ 7
3.3 HARDWARE DESCRIPTION............................................................................................... 8
3.3.1 PORTS CONFIGURATION...............................................................................................8
3.3.2 RS485 INTERFACE BOARD............................................................................................. 8
3.3.3 MULTIMODE FIBER OPTIC INTERFACE BOARD.........................................................11
4 SCHEMATIC.................................................................................................13
INSTALLATION............................................................................................14
.1 INSTALLATION.................................................................................................................. 14
6 COMMISSIONING & MAINTENACE..........................................................1
6.1 COMMISSIONING.............................................................................................................. 1
6.2 MAINTENANCE................................................................................................................. 1
7 TECHNICAL DATA......................................................................................16
8 DIMENSIONS...............................................................................................18
9 ORDERING...................................................................................................19
Page: Company: Device: Document: Code: Version: Date:
2 Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015

PREFACE
1 PREFACE
Liability statement
We have checked the contents of this manual to ensure that the descriptions of both hardware
and software are as accurate as possible. However, deviations may occur so that no liability can
be accepted for any errors or omissions contained in the information given.
The contents of this manual will be checked in periodical intervals, corrections will be made in
the following editions.
We reserve the right to make technical improvements without notice.
Contact
If you have any questions or comments related to this product please contact us on:
Ediseja 21 d.o.o.
Drenov Gric 175
1360 rhnika
Slovenia – EU
Tel: 00 386 51 643 411, 051 643 411
Email: grega.flander@ediseja21.com
www.ediseja21.com
Copyright
Copyright © Ediseja 21, 2013. All rights reserved.
Explanation of the symbols
Read the instructions!
Device was tested with 2,5 k AC voltage to check the device insulation.
Device ground terminal.
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC; the affixed
product label indicates that you must not discard this electrical/electronic product in
domestic household waste.
Company: Device: Document: Code: Version: Date: Page:
Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015 3

CMU 200 - User manual
Warnings
In this paper the following terms are used:
Danger
indicates that death, severe personal injury or substantial property damage will result if proper
precautions are not taken.
Warning
indicates that death, severe personal injury or substantial property damage can result if proper
precautions are not taken.
Caution
indicates that minor personal injury or property damage can result if proper precautions are not
taken. This particularly applies to damage on or in the device itself.
General information
These paper contain the information that is necessary for the proper and safe operation of the
described devices. This paper is intended for technically qualified personnel.
Warning!
Hazardous voltage is present inside the device during operation. Disregarding of safety rules can
result in severe personal injury or property damage.
Only qualified personnel may work with described devices after being familiar with warnings and
safety notices in this paper and other safety regulations.
Warning!
Device must operate completely assembled! Device must be used as described. No modifications
of the device should be made.
Warning!
Do not open device while it is energized! Hazardous voltage is present inside the device.
Disconnect all connectors before opening!
Page: Company: Device: Document: Code: Version: Date:
4 Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015

CMU 200 - User manual
2 CMU 200 SYSTEM
2.1 DESCRIPTION
Communication unit (CMU 200) is modular system of communication devices that can be used
for various of tasks such as:
communication converter (for example 20 channels RS232 to Fiber Optic converter)
star coupler (for example RS232 to 39 fiber optic)
CMU 200 device is a couple of software and hardware. For different purposes, different software
versions and different hardware configuration have been developed.
2.1.1 SOFTWARE
Software is application dependent and allows different hardware configurations. Software's task
is switching between communication ports and allows almost any combination between them.
2.1.2 HARDWARE
CMU 200 can handle up to 40 different interface boards. Currently available interface boards:
(non)isolated RS232
isolated RS485
Multimode Fiber Optic ST or SMA connectors
USB
ethernet (with one virtual com port)
power supply
There is possibility to use additional redundancy power supply.
Housing is made from inox and is intended for mount on standard 19"rack.
Page: Company: Device: Document: Code: Version: Date:
6 Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015

DESCRIPTION
3 DESCRIPTION
3.1 DESCRIPTION
Star coupler is communication device that transfer data from one (master) to more than one
(slave) port.
This device contains 1 RS485 and 39 multimode fiber optic ports. Data is send from master port
to all slave ports. On the other hand, data from either slave port is send to master port only.
Power supply voltage allows connection to all common station batteries. Additionaly it can be
also connected to standard AC voltages.
This device is intended for use in cubicles and cabinets in all kinds of power production,
transmission and distribution stations. It requires no maintenace. All normaly used connectors,
switches and light indicators are accessed at the back side of the device. Two light indicators
indicates power supply voltage, others indicate communication transfer.
3.2 APPERANCE
Company: Device: Document: Code: Version: Date: Page:
Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015 7
Picture 1: Front view

CMU 200 - User manual
3.3 HARDWARE DESCRIPTION
3.3.1 PORTS CONFIGURATION
Port 1 2 3 4 6 7 8 9 10
Inter. RS485 FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM
Port 11 12 13 14 1 16 17 18 19 20
Inter. FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM
Port 21 22 23 24 2 26 27 28 29 30
Inter. FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM
Port 31 32 33 34 3 36 37 38 39 40
Inter. FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM FO MM
3.3.2 RS48 INTERFACE BOARD
Description
Single, galvanically isolated, half duplex, RS485 port with Phoenix 3 pin screw connector, with
automatic switch to receive after end of transmission and with additional terminating and
stabilizating resistors.
Hardware settings
For proper functioning of that board some settings must be done:
RS485 bus termination and stabilisation
baud rate
Page: Company: Device: Document: Code: Version: Date:
8 Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015
Picture 2: Back view

HARDWARE DESCRIPTION
RS48 bus termination and stabilisation
TERMINATION
At high transmission rates or long distance, RS485 bus termination is necessary.
The termination on RS48 bus must be set on both ends of the RS48 bus.
STABILISATION
Some device, to work properly, demands that RS485 must always be in known and valid state.
That is, when + (positive) pin is more than 200 m positive than – (negative) pin. Pins + and –
are sometimes marked as A and B. In case that no device on RS485 bus is transmitting or in
case of short circuit, there is no voltage difference between those pins and some device do not
work correctly.
On this port board so called „true fail-safe“ RS485 chip is used so board works correctly without
stabilisation at invalid RS485 bus state. But still switches for stabilisation are provided on port
board. The stabilization on RS48 bus may be set on one device only!
Switches at the lower side of connector:
Switch 4 6
Description RS485 stabilisation RS485 termination RS485 stabilisation
Switches at the upper side of connector:
BAUD rate
BAUD rate Switch
Interface Interface M Interface L 1 2 3
Company: Device: Document: Code: Version: Date: Page:
Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015 9
Picture 3: RS 85 BUS schematic

CMU 200 - User manual
BAUD rate Switch
19200 4800 300 OFF OFF OFF
38400 9600 600 OFF OFF ON
7600 19200 1200 OFF ON OFF
11 200 38400 2400 ON OFF OFF
BAUD rate setting 19k2 (bps) is valid for all standard communication protocols, that do not
request special timings. If special protocols (small request-respond time required) are used
please note it in order.
NOTE! If there are problems with communication, try using higher speed setting. Some
manufacturer have different markings for B and A line. Try to switch A and B wires. See
http://en.wikipedia.org/wiki/RS-48 for detailed information.
Connector pin table
MSTB 1 2 3
Description GND - (A) + (B)
Page: Company: Device: Document: Code: Version: Date:
10 Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015
Picture : RS 85 interface board appearance with switch settings

HARDWARE DESCRIPTION
3.3.3 MULTIMODE FIBER OPTIC INTERFACE BOARD
Description
Single, full duplex, multimode, fiber optic port with ST connectors with positive or negative logic.
Hardware settings
For proper functioning of that board, optic logic must be set:
Fiber optic logic settings
Switch SW1 Light in idle state 1 2 3 4
Positive logic OFF OFF ON OFF ON
Negative logic ON ON OFF ON OFF
Company: Device: Document: Code: Version: Date: Page:
Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015 11
Picture 5: Data rate vs cable lenght

CMU 200 - User manual
INSTALLATION
.1 INSTALLATION
Warning!
Hazardous voltage is present inside the device during operation. Disregarding of safety
rules can result in severe personal injury or property damage.
Only qualified personnel may work with described devices after being familiar with warnings and
safety notices in this paper and other safety regulations.
Following instruction must be taken into consideration:
The device must be accessible to qualified personnel only.
The device is permitted to operate in enclosed housing or cabinet only.
The device location must be vibration-free.
The admisible operating temperature must be observed.
Check the device for damage at unpacking. If device is damaged it must not be installed
but It should be send to the manufacturer for repair.
The device should not be opened.
The device should be mounted on 19" rack via 4x M6x10 mm screws
Attach ground wire before attaching power supply. Device must be grounded during
operation!
Single core or stranded wire 0,5 – 2,5 mm2 must be used for power supply connection. If
stranded wire is used ferrules must be used to prevent fraying. Recommended stripping
lenght is 5 mm.
Protective earthing wire must be terminated with tinned copper ear terminal.
The prescribed bending radius of the optical fibre cables must be observed.
Page: Company: Device: Document: Code: Version: Date:
14 Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015

COMMISSIONING & MAINTENACE
6 COMMISSIONING & MAINTENACE
6.1 COMMISSIONING
Warning!
Hazardous voltage is present inside the device during operation. Disregarding of safety rules can
result in severe personal injury or property damage.
Only qualified personnel may work with described device after being familiar with warnings and
safety notices in this paper and other safety regulations.
Following instruction must be taken into consideration:
Device must operate completely assembled! Device must be used as described. No
modifications of the device should be made.
Attach ground wire before attaching power supply. Device must be grounded during
operation!
Check if the power supply voltage complies with device operation voltage.
Do not open device while it is energized! Hazardous voltage is present inside the device.
If single mode fiber optic interface is used, do not look into the laser beam.
6.2 MAINTENANCE
The device is maintenance-free. Disconnect power supply before cleaning it. Use moist cloth.
Do not use liquids.
Company: Device: Document: Code: Version: Date: Page:
Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015 15

CMU 200 - User manual
7 TECHNICAL DATA
Power supply
Rated voltage HAC 230 AC, +10 %, -10 %
220 DC, +10 %, -10 %
MDC 110 DC, +10 %, -10 %
Rated current HAC 0,3 A
MDC 0,5 A
Fuse (internal) 6,3 A T
Power supply indicator green LEDs marked Power 1 and Power 2
oltage dips 20 ms
Connector type screw type „MSTB“ Phoenix 8pin
Wire crossection 0,5 – 2,5 mm2
Communication port RS48 (interface type 48x)
Type RS485
Direction half duplex
Speed
Interface type 5 19200 - 115200 BAUD
Interface type M 4800 - 38400 BAUD
Interface type L 300 - 2400 BAUD
Number of ports 1
Distance up to 1200 m
Isolation 1000 DC
Connector type „MSTB“ Phoenix 3pin
Termination 120 Ohm
Max number of devices
on BUS 32
Communication port Multimode Fiber Optic (interface type FOx)
Type multimode fiber optic
Wave lenght 820 nm
Fiber size 50/125 μm, 62,5/125 μm, 100/140 μm, 200 μm
Optical output power -18 dB
Reciver sensitivity -24 dB
Laser class I (IEC 60825-1)
Page: Company: Device: Document: Code: Version: Date:
16 Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015

TECHNICAL DATA
Communication port Multimode Fiber Optic (interface type FOx)
Direction full duplex
Speed up to 230 k BAUD
Input 1 receiver (grey connector)
Output 1 transmitter (white connector)
Logic light ON or OFF in idle state set by switch
(see table)
Number of ports 1
Distance up to 500 m
Connector type ST
* slowest interface defines device's maximum speed
Device
Weight 6 kg
Dimensions
(see picture)
(W) (H) (D)
19" rack 3U (133 mm) 154 mm + connectors
Temperature range 0 °C to +55 °C
Humidity operating up to 95 % (noncondensing)
Enclosure Material inox
IP 20
Mount type 4x M6 screw 19" rack
Class I
Overvoltage category II
Communication indicator Receiveing yellow LED marked Rx
Tranmitting green LED marked Tx
Company: Device: Document: Code: Version: Date: Page:
Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015 17

ORDERING
9 ORDERING
ORDERING NUMBER: CMU 200 / c . c . c . c . c . c . c - c . c
(enclosure width: 19“, height: 3U, depth: 154 mm)
Power supply :
single 230 AC, 220 DC power supply .................................................................. HACx1
double 230 AC, 220 DC power supply ................................................................. HACx2
single 110 DC power supply ................................................................................... MDCx1
double 110 DC power supply .................................................................................. MDCx2
Interfaces:
RS232 nonisolated, Rx & Tx support ............................................................................. 232 x n
RS232 isolated, Rx & Tx support .................................................................................... 23I x n
RS232 nonisolated, Rx, Tx, CTS & RTS support .......................................................... 23R x n
RS232 isolated, Rx, Tx, CTS & RTS support ................................................................. 2RI x n
RS485 isolated, half duplex (19200-115200 baud) ........................................................ 485 x n
RS485 isolated, half duplex (38400 - 4800 baud) ..........................................................48M x n
RS485 isolated, half duplex (300-2400 baud) ................................................................ 48L x n
FO multimode ST .......................................................................................................... FOT x n
FO multimode SMA ....................................................................................................... FOA x n
Ethernet (one virtual com port) ...................................................................................... ETH x n
n ... number of interfaces - maximum number of interfaces in CMU 200 is 40!
Each 23R and 2RI interface must be treated as two interfaces!
Function:
three ports star coupler (up to 13 groups) .................................................................................... 2
1 on 1 converter (up to 20 groups) …............................................................................................ 7
40 port star coupler (1 master, up to 39 slaves) .......................................................................... 12
39 port star coupler (2 masters to 4 slaves (3 groups), 2 masters to 5 slaves (3 groups) .......... 15
40 port star coupler (1 master to 9 slaves, up to 4 groups) ......................................................... 18
For other functions please contact us.
Software Version:
software version ................................................................................................................. leave empty
Example: CMU 200 / HACx2 . 232x3 . FOTx27 - 18 is
1x RS232 to 9x fiber optic, 3 groups star coupler with
- two 230 AC power supply
- 3 RS232 interfaces
- 27 fiber optic interfaces with ST connector
Additional accessories (order if needed):
- power supply cable with „schuko“ plug, 2 m
- RS232 cable to PC (state the lenght up 15 m)
- fiber optic cables (state the lenght)
Company: Device: Document: Code: Version: Date: Page:
Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015 19

CMU 200 - User manual
Contact:
Ediseja 21, razvoj elektronskih naprav, d.o.o.
Drenov Gric 175
1360 rhnika
Slovenia – EU
Tel: 00 386 51 643 411, 051 643 411
grega.flander@ediseja21.com
www.ediseja21.com
Page: Company: Device: Document: Code: Version: Date:
20 Ediseja 21 CMU200/XXXx2.485x1.FOTx39 User manual CMUMU203 1 28.05.2015
Table of contents