BO08A01KNXFI01010002.DOC
Din Rail 8 Output Module– Product Handbook
2/51
Eelectron SpA, Via Magenta 77/22, I-20017 Rho (MI), Italia
+39 02.9316681 +39 02.93507688
BO08A01KNXFI01010002.DOC
C.F. e P.IVA 11666760159
Capitale sociale: 800.000,00€ interamente versato
Tribunale di Milano 359157-8760-07
CCIAA Milano 148549
INDEX
1.General Introduction ....................................................................................................... 4
2.Product and functional overview..................................................................................... 4
2.1.Address and associations limits ............................................................................ 5
3.General Parameter Configuration................................................................................... 6
3.1.Parameters............................................................................................................ 6
3.2.Communications Objects....................................................................................... 7
4.Output Configuration....................................................................................................... 8
5.Output Configuration Fan Coil Actuator........................................................................ 10
5.1.Electric connections............................................................................................. 11
5.2.Control of Heating / Cooling Valve ...................................................................... 11
5.3.Fan Coil Speed Control ....................................................................................... 12
6.Output Configuration for Generic Load Control ............................................................ 14
6.2.General Parameters ............................................................................................ 15
6.3.Relay Functions................................................................................................... 16
6.4.Additional Functions ............................................................................................ 17
6.5.Function ON / OFF .............................................................................................. 18
6.6.Function ON/OFF with delay ............................................................................... 19
6.7.Function ON with delay / timing OFF................................................................... 20
6.8.Function “Continuous Switching”......................................................................... 25
6.9.Communication objects ....................................................................................... 26
6.10.Logic Function ..................................................................................................... 27
6.11.Lock Function ...................................................................................................... 28
6.12.Scene Function.................................................................................................... 29
7.Output Configuration for Electric Valve Control ............................................................ 31
7.2.Main Parameters ................................................................................................. 32
7.3.Lock Function ...................................................................................................... 36
8.Output Configuration for shutter and blinds .................................................................. 38
8.2.General Parameters ............................................................................................ 39
8.3.Louvres automatic movement ............................................................................. 42
8.4.Additional Functions ............................................................................................ 42
8.5.Scene Function.................................................................................................... 43
8.6.Lock Function ...................................................................................................... 44
8.7.Alarm Function .................................................................................................... 45
8.8.Shutter position after lock and alarm ................................................................... 46
8.9.Priority table for communication objects.............................................................. 46
9.Output Configuration for motor reduction driver ........................................................... 47
9.2.Main Parameters ................................................................................................. 48
9.3.Lock Function ...................................................................................................... 50
9.4.Function VALVES ALL CLOSED......................................................................... 51