230V A, AT, WL, PC
llluminants 4x3,5W
LED
Light current net Flux
950lm
Power consumption
13VA
Battery current input
34mA
Voltage supply
230V 50/60Hz / 220V DC +25/-20%
Temperature range
-10°C – +40°C
Emergency exit luminaire 300
for surface mounting
This is a professional manual for certified electricians and professional instal-
lation companies only. When installing the self contained version follow the
additional instructions.
General safety notices
Relevant safety and accident prevention measures, accepted technology re-
gulations and the following safety notices must be observed when installing
or carrying out any work on the safety light. In particular, the lamp must be
disconnected from the mains and special care must be taken, as it will still be
live from the backup system.
Lamp models with monitoring module
For lamp models with monitoring module for individual lamp monitoring, the
configuration of individual lamp addresses and additional functions must be
carried out in accordance with the images and data provided on the monito-
ring module or in the enclosed alignment instructions.
Self contained luminaires
For self contained luminaires the replacement of the battery is needed when
the battery no longer meets its rated duration of operation after the corres-
ponding recharge period.
Disposal
Please observe current regulations of ElektroG for the disposal and recycling
of lamps.
Spare parts
Only use original parts for the replacement of illuminants, electronic compo-
nents and accumulators (where applicable) to ensure compliance with nominal
data!
Attention
Any damage incurred due to non-compliance with this manual will not be
covered by the warranty. We accept no liability for consequential damages
incurred due to non-compliance. Make sure to read this manual prior to com-
missioning the product.
Subject to technical changes without notice!
Technical specifications
Schutzart
Protection class
Indice de protection boîtier
IP 20
Schutzklasse
Safety class
Classe de protection
I / 230V 3 x 2,5 mm² Connecting terminals (mm² for double assignment)
Abmessungen B x H x T
Dimensions (W x H x D)
Dimensions (l x H x P)
300 x 154 x 300 mm