manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Vista
  6. •
  7. Landscape Lighting
  8. •
  9. Vista 2205 User manual

Vista 2205 User manual

INSTALLATION INSTRUCTIONS
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Silicone Fille
d
Safety Connectors
36” Pigtail
Adjustable Knuckle
Housing
Main Supply Cable
Ground Stake
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the xture shown without further notication.
LAMP INSTALLATION/REPLACEMENT:
CAUTION: Do not exceed maximum wattage marked on luminaire label.
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Remove shroud to expose lamp.
3. Replace lamp with correct wattage and type marked on xture label.
NOTE: DO NOT touch lamp with bare hands. Always use soft cloth or the
plastic wrapping (if available) from lamp to handle the lamp.
4. Re-install shroud.
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
WARNING: TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS:
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamps get hot quickly! Contact only switch/plug when turning on.
3. Do not touch hot lens, guard or enclosure.
4. Keep lamp away from material that may burn.
5. Do not touch the lamp at any time. Use a soft cloth. Oil from the skin may
damage lamp.
6. Do not operate luminaire tting with a missing or damaged cover.
IMPORTANT SAFETY INSTRUCTIONS - THE LIGHTED LAMP IS HOT!
SAVE THESE INSTRUCTIONS (Leave with property owner/manager)
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone lled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
Up & Accent Lights
Landscape Series
2205
SEE REVERSE FOR LED
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
FIXTURE TOP
FIELD REPLACEABLE
LED ENGINE
SPLICE CONNECTOR
SILICONE O-RING
KNUCKLE ASSEMBLY
FIXTURE BASE
The operating voltage range for this LED luminaire is 6 - 15 volt AC. The Vista electronic driver ensures the LED operates at the intended lumen output while
receiving voltage as low as 6 volts, and as high as 15 VAC, resulting in a balanced lumen output from the rst xture to the last. Eliminating the dimness issues
often attributed to voltage drop.
Note: Operating voltage range for LED luminaries will vary depending on model, style and total number of LEDs. To help determine the operating voltage range
for each Vista luminaire, always consult factory’s specication sheet and/or installation instructions before installation.
INSTALLATION INSTRUCTIONS
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone lled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the xture shown without further notication.
SEE REVERSE FOR INCANDESCENT
2205 04.16
Silicone Fille
d
Safety Connectors
36” Pigtail
Adjustable Knuckle
Housing
Main Supply Cable
Ground Stake
LED ENGINE INSTALLATION/REPLACEMENT:
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Remove luminary pigtail from main supply cable.
3. Remove xture top from base.
4. Gently pull wire to remove LED engine from xture top.
5. Loosen knuckle assembly to allow engine and pigtail assembly to be
removed from xture.
6. Thread replacement LED engine into knuckle.
7. Re-assemble knuckle and aim to desire position.
8. Re-install engine to xture top and fasten to base.
9. Re-connect pigtail to main supply cable.
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
Up & Accent Lights-LED
Landscape Series
2205

Other Vista Landscape Lighting manuals

Vista 2129 User manual

Vista

Vista 2129 User manual

Vista 4260 Landscape series User manual

Vista

Vista 4260 Landscape series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 8202 Series User manual

Vista

Vista 8202 Series User manual

Vista 1162 Architectural Series User manual

Vista

Vista 1162 Architectural Series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista Landscape Series User manual

Vista

Vista Landscape Series User manual

Vista 8229 User manual

Vista

Vista 8229 User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Popular Landscape Lighting manuals by other brands

LIGMAN ALDO 4 installation manual

LIGMAN

LIGMAN ALDO 4 installation manual

Intex SL1006 owner's manual

Intex

Intex SL1006 owner's manual

LED Group ROBUS R2IN13W quick start guide

LED Group

LED Group ROBUS R2IN13W quick start guide

Patriot Lighting 343-1484 installation manual

Patriot Lighting

Patriot Lighting 343-1484 installation manual

LIGMAN JET 44 installation manual

LIGMAN

LIGMAN JET 44 installation manual

Hess SERA G: SERA S Installation and operating instructions

Hess

Hess SERA G: SERA S Installation and operating instructions

LIGMAN MALTA 1 installation manual

LIGMAN

LIGMAN MALTA 1 installation manual

Saxby Lighting Islay 68784 Instruction leaflet

Saxby Lighting

Saxby Lighting Islay 68784 Instruction leaflet

LIGMAN EU-10016-3 installation manual

LIGMAN

LIGMAN EU-10016-3 installation manual

LIGMAN KI-60475 installation manual

LIGMAN

LIGMAN KI-60475 installation manual

Cooper Lighting McGraw-Edison ZD Credenza specification

Cooper Lighting

Cooper Lighting McGraw-Edison ZD Credenza specification

Cooper Lighting Generation CLB25MWW5C373 Specification sheet

Cooper Lighting

Cooper Lighting Generation CLB25MWW5C373 Specification sheet

Malibu Boats CM110P instructions

Malibu Boats

Malibu Boats CM110P instructions

AMP Lighting OrchardPro APL-3018-B-BZ Installation & maintenance guide

AMP Lighting

AMP Lighting OrchardPro APL-3018-B-BZ Installation & maintenance guide

Cooper Lighting Invue 42 - 175W Specification sheet

Cooper Lighting

Cooper Lighting Invue 42 - 175W Specification sheet

ABBA SPB12 installation guide

ABBA

ABBA SPB12 installation guide

Techmar Garden Lights GILVUS + manual

Techmar

Techmar Garden Lights GILVUS + manual

LIGMAN RADO 1 installation manual

LIGMAN

LIGMAN RADO 1 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.