INSTALLATION INSTRUCTIONS
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
Silicone Fille
d
Safety Connectors
36” Pigtail
Adjustable Knuckle
Housing
Main Supply Cable
Ground Stake
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the xture shown without further notication.
LAMP INSTALLATION/REPLACEMENT:
CAUTION: Do not exceed maximum wattage marked on luminaire label.
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Remove shroud to expose lamp.
3. Replace lamp with correct wattage and type marked on xture label.
NOTE: DO NOT touch lamp with bare hands. Always use soft cloth or the
plastic wrapping (if available) from lamp to handle the lamp.
4. Re-install shroud.
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
WARNING: TO REDUCE THE RISK OF FIRE, OR INJURY TO PERSONS:
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamps get hot quickly! Contact only switch/plug when turning on.
3. Do not touch hot lens, guard or enclosure.
4. Keep lamp away from material that may burn.
5. Do not touch the lamp at any time. Use a soft cloth. Oil from the skin may
damage lamp.
6. Do not operate luminaire tting with a missing or damaged cover.
IMPORTANT SAFETY INSTRUCTIONS - THE LIGHTED LAMP IS HOT!
SAVE THESE INSTRUCTIONS (Leave with property owner/manager)
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone lled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
Up & Accent Lights
Landscape Series
2205
SEE REVERSE FOR LED
1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
FIXTURE TOP
FIELD REPLACEABLE
LED ENGINE
SPLICE CONNECTOR
SILICONE O-RING
KNUCKLE ASSEMBLY
FIXTURE BASE
The operating voltage range for this LED luminaire is 6 - 15 volt AC. The Vista electronic driver ensures the LED operates at the intended lumen output while
receiving voltage as low as 6 volts, and as high as 15 VAC, resulting in a balanced lumen output from the rst xture to the last. Eliminating the dimness issues
often attributed to voltage drop.
Note: Operating voltage range for LED luminaries will vary depending on model, style and total number of LEDs. To help determine the operating voltage range
for each Vista luminaire, always consult factory’s specication sheet and/or installation instructions before installation.
INSTALLATION INSTRUCTIONS
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone lled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the xture shown without further notication.
SEE REVERSE FOR INCANDESCENT
2205 04.16
Silicone Fille
d
Safety Connectors
36” Pigtail
Adjustable Knuckle
Housing
Main Supply Cable
Ground Stake
LED ENGINE INSTALLATION/REPLACEMENT:
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Remove luminary pigtail from main supply cable.
3. Remove xture top from base.
4. Gently pull wire to remove LED engine from xture top.
5. Loosen knuckle assembly to allow engine and pigtail assembly to be
removed from xture.
6. Thread replacement LED engine into knuckle.
7. Re-assemble knuckle and aim to desire position.
8. Re-install engine to xture top and fasten to base.
9. Re-connect pigtail to main supply cable.
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.
Up & Accent Lights-LED
Landscape Series
2205

Other Vista Landscape Lighting manuals

Vista 4260 Landscape series User manual

Vista

Vista 4260 Landscape series User manual

Vista Landscape Series User manual

Vista

Vista Landscape Series User manual

Vista 2129 User manual

Vista

Vista 2129 User manual

Vista 1162 Architectural Series User manual

Vista

Vista 1162 Architectural Series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Vista 8229 User manual

Vista

Vista 8229 User manual

Vista 8202 Series User manual

Vista

Vista 8202 Series User manual

Vista 12V Series User manual

Vista

Vista 12V Series User manual

Popular Landscape Lighting manuals by other brands

Volt VSPL-9001-25-BBZ installation instructions

Volt

Volt VSPL-9001-25-BBZ installation instructions

Volt 390 Series installation instructions

Volt

Volt 390 Series installation instructions

Portfolio 00299 manual

Portfolio

Portfolio 00299 manual

Hess CANTO Installation and operating instructions

Hess

Hess CANTO Installation and operating instructions

Light O Rama CR150D Programming guide

Light O Rama

Light O Rama CR150D Programming guide

AMP Lighting G2 ControlPro Series Installation & maintenance guide

AMP Lighting

AMP Lighting G2 ControlPro Series Installation & maintenance guide

LIGMAN ATLANTIC 13 installation manual

LIGMAN

LIGMAN ATLANTIC 13 installation manual

Cooper Lighting N175MV instruction manual

Cooper Lighting

Cooper Lighting N175MV instruction manual

Malibu Boats CS290 instructions

Malibu Boats

Malibu Boats CS290 instructions

MELINERA HG00374A Operation and safety notes

MELINERA

MELINERA HG00374A Operation and safety notes

ABBA CDPA62 installation guide

ABBA

ABBA CDPA62 installation guide

Unex 180-212-71 / 3000K operating manual

Unex

Unex 180-212-71 / 3000K operating manual

Volt VFL-4501-4-BBZ installation instructions

Volt

Volt VFL-4501-4-BBZ installation instructions

GE Evolve GEH-6014B installation guide

GE

GE Evolve GEH-6014B installation guide

Pontec PondoStar Set 30 operating instructions

Pontec

Pontec PondoStar Set 30 operating instructions

LIGMAN EU-30226-3 installation manual

LIGMAN

LIGMAN EU-30226-3 installation manual

LIGMAN EU-10036-3 installation manual

LIGMAN

LIGMAN EU-10036-3 installation manual

Effekta Emergency luminaire 300 Mounting instructions

Effekta

Effekta Emergency luminaire 300 Mounting instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.