1625 Surveyor Avenue • Simi Valley, CA 93063 • (805) 527-0987 • (800) 766-VISTA (8478)
FIELD REPLACEABLE
LED ENGINE
SPLICE CONNECTOR
SILICONE O-RING
KNUCKLE ASSEMBLY
FIXTURE BASE
The operating voltage range for this LED luminaire is 6 - 15 volt AC. The Vista electronic driver ensures the LED operates at the intended lumen output while
receiving voltage as low as 6 volts, and as high as 15 VAC, resulting in a balanced lumen output from the rst xture to the last. Eliminating the dimness issues
often attributed to voltage drop.
Note: Operating voltage range for LED luminaries will vary depending on model, style and total number of LEDs. To help determine the operating voltage range
for each Vista luminaire, always consult factory’s specication sheet and/or installation instructions before installation.
INSTALLATION INSTRUCTIONS
LUMINAIRE MOUNTING:
1. To prevent electrical shock, disconnect transformer from electrical supply
before installation or service.
2. Run wire pigtail from luminaire through mounting hole in top of ground
stake.
3. Thread luminaire into threaded hole in ground stake.
4. Place stake in desired position and insert into ground until ange of stake is
ush to grade.
5. Strip two leads from luminaire pigtail. Using two silicone lled safety
connectors (provided), connect leads from luminaire to main supply cable
leads.
NOTE: Luminaires are supplied with 36” of 18-2 cable pigtail for secure
connection to main supply cable. Wire is to be protected by routing in close
proximity to luminaire. Wiring should be buried a maximum depth of 6 inches
(15.2 cm) in order to connect to main supply cable.
6. Provide power to luminaire and check for proper operation.
Vista Professional Outdoor Lighting reserves the right to modify the design and/or construction of the xture shown without further notication.
SEE REVERSE FOR INCANDESCENT
2205 04.16
d
36” Pigtail
Adjustable Knuckle
Housing
Main Supply Cable
Ground Stake
LED ENGINE INSTALLATION/REPLACEMENT:
1. To prevent electrical shock, disconnect transformer from electrical supply
before service.
2. Remove luminary pigtail from main supply cable.
3. Remove xture top from base.
4. Gently pull wire to remove LED engine from xture top.
5. Loosen knuckle assembly to allow engine and pigtail assembly to be
removed from xture.
6. Thread replacement LED engine into knuckle.
7. Re-assemble knuckle and aim to desire position.
8. Re-install engine to xture top and fasten to base.
9. Re-connect pigtail to main supply cable.
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING: Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes. Failure to do so will void the warranty and may
result in serious injury and/or damage to the luminaire.
SAFETY WARNING: Luminaire can become very hot depending on lamp wattage used. Lens and metal around lamp can become hot enough to blister hands.
Particular care should be taken not to locate luminaires where small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO BE BURIED MORE THAN 6”.
WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF TRANSFORMER RATING. DO NOT USE EXTENSION CORDS
ON POWER UNITS.
NOTE: Always use UL recognized wire connectors for connections.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.