PLEASE READ BEFORE
TURNING THE PC ON
8 Channel HD Audio
Quick Start Guide – First time setup instructions
Draining Procedure
Filling Procedure
Disconnect all the external cables including the power cable
and remove all external panels from the chassis. Stand the
system upright on the back side and attach a tube to the lower
port on the front of the reservoir. Place the tube into an
appropriate drain or container and put the system back on its
feet. Remove the plug from the fill port to allow the coolant to
drain faster. Tilt the chassis in every direction to remove as
much coolant as possible.
Over time your system may require additional coolant or you might want to add
dyes to customize the appearance. It is important that you do not mix coolants.
If you are topping off the coolant use pure distilled water.
Disconnect all external cables including the power cable and
remove all external panels from the chassis. Ensure thet the
drain port is sufficiently tightened and fill the reservoir through
the top front port, with the provided fill bottle. Momentarily
power on the system until the reservoir level drops enough to
add more coolant. Repeat until the components are completely
free of air.
1. Unbox the PC and place carefully on a flat desk or open floor space. You
will need a small amount of room to tilt the system later.
2. Remove the two thumb screws located on the back of the case and pull
the handle to remove the top panel.
3. Carefully lift out the front and side glass panels. Be sure to support the
bottom of the panel in case of slips.
4. Carefully remove the shipping foam located inside the case. Please do
not discard! This should be stored in your case box in case of future
transport or return.
5. Remove the bottle of Cryofuel from the case, along with the fill bottle.
6. Locate the fillport at the front of the case, unscrew the port cover with
a coin. We advise against using a screwdriver.
7. Using the provided fill bottle, fill the distribution plate to the marked
line.
8. Replace the port cover, screw until tight, but do not over-tighten.
9. Remove the sticker over the power button and start up your system!
10. Once the distribution plate has emptied into the water-loop, turn off your
system and repeat steps 7-9 until the coolant level remains at the marked
line.
11. Allow the system to run for a few minutes, until bubbles in the water-loop
have finished surfacing at the top of the distribution plate.
12. Gently tilt the system side to side, making sure to secure the system with both
hands. This will help to circulate any remaining bubbles in your water-loop.
13. Should the coolant level drop below the fill line in your distribution plate after
step 11, repeat steps 7-8.
14. Gently slide the front and side glass panels into the chassis.
15. Slide the top panel back onto the chassis, secure with thumb screws.