Electrocorp Clean Breeze III User manual

Congratulations!
You are moments away from fresher, cleaner indoor air. Your new AllerAir unit will combat many of the
chemicals, gases, and odors responsible for poor indoor air quality (IAQ). Poor IAQ may cause or worsen
allergies, asthma, multiple chemical sensitivities (MCS) and sick building syndrome. We recommend
proper maintenance of your unit to keep it running efficiently for years to come.
Model No. ___________________
Serial No. ___________________
Operation and
Maintenance Manual
Clean Breeze III
Note:
As original packaging is required for warranty returns,
new AllerAir owners are advised to keep boxes and
shipping materials.
Operation:
All units except D and DX models are shipped fully assembled and ready for use. (D and DX model owners
may refer to their additional instruction sheet for filter installation, or refer to Page 5 of this booklet.)

CleanBreezeIII

3Electrocorp · 1.866.667.0297 · www.electrocorp.net
Operating and Maintenance Manual
REPLACING OR CLEANING THE PRE-FILTER
STEP 1 STEP 3
STEP 2
We recommend changing or cleaning pre-filters every one to two months.
No user serviceable parts inside.
Risk of fire, electric shock, or injury to persons through misuse.
This is an electrical appliance. It is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given prior instructions concerning use of the appliance or they are being supervised by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Do not operate any unit with a damaged cord or plug. Discard unit or return to AllerAir for examination
and/or repair.
Do not run cord under carpeting and do not cover it up in any way. Do not place cord under furniture
or appliances. Arrange cord away from high-traffic areas and do not make it a tripping hazard.
Refrain from poking or sticking any object into the unit’s air vent discharge.
Do not use any parts, attachments or filters not recommended by AllerAir.
WARNING!
To install: Gently press the
pre-filter flat against the inner
walls of the innermost filter.
Return the unit to an upright
position.
Slowly remove the dirty pre-filter to avoid
dispersing its contents.
To clean: Carefully vacuum both sides of
the filter.
To discard:Gently insert into a plastic bag
and discard.
Turn the unit off, unplug it,
and gently lay it on its
side.
GETTING STARTED
Keep packaging in case of warranty returns
Wipe the unit with a soft damp cloth to remove any dust which may have accumulated
during shipping
Check the inlet opening for extra prefilters if ordered. (Bottom of unit)
Place the unit on its casters and plug it into a 120-volt outlet with ground
Run the unit on TURBO for a few minutes to re-adjust the airflow patterns in the room
Depending on your interior conditions, you may choose to run the unit on HIGH during
the day and on LOW at night*
Running the unit on LOW is energy-efficient and increases the amount of air dwell time
in the cleansing chambers
*Depending on interior dust conditions. For VOC's, chemicals, smoke or odors we suggest operating continuosly on the
low setting to allow for the longest dwell time and adsorbtion.

STEP 1
Make sure the unit is set to
“Off” and the unit is unplugged.
STEP 3
Grasp the top. Remove the top by
pulling gently up.
STEP 2
Using a #2 Philips screwdriver,
remove the four screws that hold
the top onto the unit.
CleanBreeze Series
REPLACING superHEPA and/or CARBON FILTERS
STEP 4
Reach inside the unit, and remove
felt pad.
STEP 5A or
Remove the carbon filter along
with the 0.1 micron superHEPA
filter. (pull up gently by placing
thumbs on the inner side of the
filter)
STEP 5B
Remove the carbon filter along
with the 0.1 micron superHEPA
filter. For 5” ultra models, use
straps to pull up gently.
FILTER ASSEMBLY HD and Ultra
The model you have selected is shipped in 2 separate boxes to protect certain components. The
filter comes in one box, and the outer shell of the unit, containing the motor and the fan, comes in
another. Filters must be installed before turning the unit on in order for it to work. AllerAir
technicians recommend removing the base, installing the filter, and replacing the base according to
steps 1 - 4 and 12 - 16 of the following procedure.
PRE-FILTER ORDER REFERENCE NUMBERS*
Models PrefiltersAirMedic Pro 5 AirMedic Pro 6 Notes
Exec, VocarbPoly Prefilters A5FMP009 A6FMP012packs of 4 or 8
S Models Tacky Prefilters A5FMPS09 A6FMPS12 packs of 5 or 10
Ultra Models Poly Prefilters A5FMP911 A6FMP1211 packs of 4 or 8
MCS Models Cotton Prefilters A5FCP019 A6FCP022packs of 6
*Please use the above part numbers when ordering your replacement parts.
To order a new pre-filter, call AllerAir toll-free at 1-888-852-8247 during regular business hours (EST), or
4
Visit our clean air news blog: https://www.allerair.com/blogs/clean-air-news-blog

Salon Series
STEP 16
The unit is now ready for use.
STEP 15
Replace the four screws.
STEP 14
Replace the top, making sure the
arrow on the gold sticker lines up
with unit's rear seam.
5Electrocorp · 1.866.667.0297 · www.electrocorp.net
STEP 6
Remove the used 0.1 micron
superHEPA filter.
Operating and Maintenance Manual
STEP 10
While wrapping the strap around
the filter make sure to exert a
reasonable amount of tension on
the strap so it is not loose once the
loop is complete.
STEP 11
Procedure ended successfully -
metal angle exerts pressure on the
edge of the superHEPA. Straps
keep the material in contact with
filter’s edges.
NEW
CARBON
STEP 12A or
Gently insert the new carbon filter
into the unit, either end up.
See page 6 for instructions on
replacing carbon filling.
STEP 12B
For 5” ultra models, use straps to
insert new carbon filter into unit.
See page 6 for instructions on
replacing carbon filling.
STEP 13
Put back the felt pad removed in
STEP 4.
STEP 9
Place “hook” side of the velcro
strap on the inside and start
wrapping the strap around the
edge of the filter.
STEP 8
Position metal bar on the edge of
overlap after wrapping the
superHEPA around the outside of
the carbon canister.
STEP 7
Replace with a new 0.1 micron
superHEPA.

6
Visit our clean air news blog: https://www.allerair.com/blogs/clean-air-news-blog
CleanBreeze Series
HEPA & CARBON FILTERS ORDER GUIDE
These replacement filters will extend the life of your AllerAir unit. Please be sure to follow the
instructions for changing the filters in your unit.
We recommend changing pre-filters every two months, HEPA filters every three to five years, and
carbon filters every two years.
ORDER REFERENCE NUMBERS
Please use the numbers in the following charts when placing your order. Call AllerAir at
1-888-852-8247 during regular business hours (EST) or send an e-mail to info@allerair.com.
Models AirMedic Pro 5 AirMedic Pro 6
HD Models
Ultra Models
Microparticulate SuperHEPA Filter Order Guide
Replacement Carbon Filter Order Guide
Models
MCS Models 2"** A5FCW120 - - - - - - - - -
Plus Exec Models 3"** A5FCW330 A6FCW330
Plus Vocarb Models 3"** A5FCW230 A6FCW230
HD Exec Models 3.5"** A5FCW335 A6FCW335
HD MCS Models3.5" A5FCW130 - - - - - - - - -
HD Vocarb Models3.5" A5FCW235 A6FCW235
HDS Models 3.5” A5FCW635 A6FCW635
MG Exec Models 4" A5FCW340 A6FCW340
MG Vocarb Models 4” A5FCW240 A5FCW240
Ultra Exec Models 5” A5FCW350 A6FCW350
UltraS Models 5” A5FCW650 A6FCW650
Ultra Vocarb Models 5” A5FCW250 A6FCW250
Please use the following part
numbers when ordering your
replacement parts.
If you have ordered a special blend
of carbon in the past please let us
know about it when ordering the
replacement.
**Please refer to your carbon filter
depth when ordering a replacement.
Please use the following part
numbers when ordering your
replacement parts.
This is the filter that wraps around
any carbon filter.
AirMedic Pro 5 AirMedic Pro 6
Plus Models A5FSH945 A6FSH1245
A5FSH948 A6FSH1248
A5FSH948 A6FSH1248

Operating and Maintenance Manual
Please use these part
numbers when ordering
your replacement parts.
REFILLING THE CARBON CANISTER
Your AllerAir unit contains a refillable carbon filter. You may choose to refill it* or simply purchase a
new filter. Tools Required: Philips screwdriver, garbage bag large enough to hold all of the old carbon, rubber mallet.
*When changing the carbon filter, it should be placed on a newspaper or protective surface as it may leak some carbon particles.
AllerAir makes a special funnel to evenly refill carbon filters. Call 1-888-852-8247 during regular
business hours (EST) or send an e-mail to info@allerair.com.
STEP 2
Gently pull back the pre-filter to
access the four screws at the top of
the filter. Remove the screws with a
Philips screwdriver and take off the
lid of the filter.
STEP 3
Discard all of the old carbon. Pour
it into a garbage bag of adequate
size and tie the bag shut.
STEP 4
Pour in the new carbon, using a funnel
if desired. As you pour, tap the sides
of the filter with the rubber mallet to
help settle the carbon granules.
STEP 5
When the filter is full, replace the lid
and its screws. Adjust the pre-filter,
and gently slide the filter back into
the unit.
STEP 6
Replace the felt gasket. Replace
the base of the unit. Align the
arrow on the gold sticker with the
unit's seam, and replace the four
screws with a Philips screwdriver.
STEP 1
Remove the carbon filter from the unit
by pressing thumbs against the inner
rim and pulling up.
Bulk Carbon Order Guide
Models AirMedic Pro 5 AirMedic Pro 6
Exec Mix AM000911 AM000911
Vocarb Mix AM000912 AM000912
TobaccoSmoke Mix AM000912 AM000912
MCS Mix AM000901 AM000901
Special Blend MixPlease Call
7Electrocorp · 1.866.667.0297 · www.electrocorp.net

TEN YEAR LIMITED WARRANTY
Your AllerAir unit comes with a 5-year limited warranty excluding expendable parts such as pre-filters
and filters. This warranty provides for the repair of any defective components and labor for 10 years
from the date of delivery. An additional 5-year warranty is provided on parts. This product is not
covered against damage resulting from misuse. This warranty does not cover damage, fault or failure
due to alteration or repairs made by anyone other than AllerAir or the use of supplies and
acccessories other than those manufactured by AllerAir. This warranty is provided to the original
purchaser and may not be transferred. A return authorization number is required for warranty repairs.
Please contact AllerAir at 1-888-852-8247 for more information.
THE ALLERAIR AIR FILTRATION SYSTEM
ACTIVATED CARBON
Your AllerAir air purifier contains activated carbon that permanently traps dangerous airborne
chemicals, gases and odors. This vital filter should be changed approximately every two to three
years, depending on the environment in which the unit is operating. You can also upgrade your Plus
or HD unit at any time to accommodate a larger and deeper carbon filter suitable for removing
heavier concentrations of chemicals, gases and odors.
PRE-FILTER
The pre-filter included with your unit removes larger particles and helps prolong the life of your HEPA
filter. The pre-filer should be vacuumed or replaced every three months.
SUPER-HEPA*
HEPA filters are widely recommended by allergists, doctors and indoor air quality experts for home
and office use. The robust and flexible Super-HEPA in AllerAir units traps 99.9% of fine particles at 0.1
microns in size, including dust, hair, pollen and even some bacteria and viruses. Depending on the
particle level in the environment in which the unit is used, your HEPA filter should be replaced every
three to five years.
*Note that a pleated HEPA filter is also available. Contact AllerAir or check our website for more
information.
THE ALLERAIR ADVANTAGE
Our units offer complete air filtration removing airborne chemicals, gases, odors and particles.
Our deep bed, activated carbon filters last longer than the average thin filter which is generally
carbon sprayed onto a synthetic material.
Our units do not use dangerous ozone technology
Our units are manufactured to clean your air and therefore are not made with a plastic housing, or
other materials which may off-gas chemicals.
Our units are powered by American-made motors that are energy efficient and cost only pennies a
day to operate.
Particles from paint may clog your HEPA filter, therefore we recommended that users unplug their
units and remove the HEPA filter, storing it off-site until the paint job is complete. Due to the
serious toxic nature of paint it is also recommended that your carbon filter be replaced or refilled in
the weeks after the paint job is complete. See, Replacing HEPA and/or carbon filters, for
instructions on how.
PLANNING ON PAINTING YOUR HOME? READ THIS FIRST:
IMPORTANT NOTICE!
1.888.852.8247
www.electrocorp.net
E-0197
Table of contents
Popular Industrial Equipment manuals by other brands

Donaldson Torit
Donaldson Torit WSO 20 Installation and operation manual

VOLTCRAFT
VOLTCRAFT VC-CJS61 operating instructions

Loctite
Loctite Zeta 7411-S instruction sheet

Siemens
Siemens BD2 installation instructions

Titgemeyer
Titgemeyer SAN2URCap Implemenation Guide

IMC
IMC F79/060 Operating, and servicing instructions

Wilo
Wilo Stratos PICO Installation and operating instructions

Trumpf
Trumpf TC 2020R Student guide

Allen-Bradley
Allen-Bradley Guardmaster LRTS installation instructions

ABB
ABB LT 460AC operating instructions

Arroyo Instruments
Arroyo Instruments TECMount 286 user manual

BioZone Scientific International
BioZone Scientific International IceZone x manual