SERVICE MANUAL
5.2 TROUBLESHOOTING BY CODED ANOMALIES LIST
The evolved diagnostics of the machine manages the behavior of the appliance when the system detects some issue and
the display can show the following errors:
Event Anomaly Type of
Anomaly General description Possible cause Instruction to User Service Action
Alarm 01 TANK FILLING Alarm
Blocking
TANK not lling
Button G is xed red
1) Tap does not supply water
2) Overow pipe placed incorrectly or not
inserted;
3) Rinse arm nozzles clogged;
4) Inlet pipe constricted
5) Faulty or clogged solenoid valve
6) Clogged boiler
7) Faulty pressure switches
8) Clogged air gap
9) Faulty PCB
To reset this errors, the PCB must
be switched o and then on again
(ON-OFF button).
1) Open water tap
2) Place Overow pipe properly
3) Clean Rinse arm nozzles;
4) Fix Inlet pipe path
5) Please call Service Center
6) Please call Service Center
7) Please call Service Center
8) Please call Service Center
9) Please call Service Center
5) Replace solenoid valve
6) Clean boiler
7) Replace pressure switches
8) Clean air gap
9) Replace PCB
Alarm 02 BOILER HEATING Warning
Not blocking
BOILER not heating
Button G is blinking red
1) Faulty heating element
2) Check boiler heating contactor
3) Faulty PCB relay
To reset this errors press button D
Please call Service Center
1) Replace heating element
2) Replace boiler heating contactor
3) Replace PCB
Alarm 03 TANK HEATING Warning
Not blocking
TANK not heating
Button G is blinking red
1) Faulty heating element
2) Check tank heating contactor
3) Faulty PCB relay
To reset this errors press button D
Please call Service Center
1) Replace heating element
2) Replace tank heating contactor
3) Replace PCB
Alarm 04 TANK DRAINING Warning
Not blocking
No TANK draining within
time-out
Button G is blinking red
1) Dirty lters
2) Drain hose blocked or pinched
3) Drain pump blocked by a foreign body
4) Faulty pressure switches
5) Faulty PCB
To reset this errors, press button D
1) Clean lters
2) Please call Service Center
3) Please call Service Center
4) Please call Service Center
5) Please call Service Center
2) Clean drain hose
3) Clean drain pump
4) Replace pressure switches
5) Replace PCB
Alarm 05 BOILER FILLING Alarm
Blocking
BOILER not lling
Button G is xed red
1) Tap does not supply water
2) Inlet pipe constricted
3) Faulty or clogged solenoid valve
4) Faulty pressure switches
To reset this errors, the PCB must
be switched o and then on again
(ON-OFF button).
1) Open water tap
2) Fix Inlet pipe path
3) Please call Service Center
4) Please call Service Center
3) Replace solenoid valve
4) Replace pressure switches
Alarm 06 BOILER PROBE Warning
Not blocking
Boiler probe temperature
outside range
Button G is blinking red
1) Detached boiler temperature probe
2) Faulty boiler temperature probe
To reset this errors, press button D
Please call Service Center
1) Reconnect boiler temperature probe
2) Replace boiler temperature probe
Alarm 07 TANK PROBE Warning
Not blocking
Tank probe temperature
outside range
Button G is blinking red
1) Detached tank temperature probe
2) Faulty tank temperature probe
To reset this errors, press button D
Please call Service Center
1) Reconnect tank temperature probe
2) Replace tank temperature probe
Alarm 08 THERMOSTOP
TIME-OUT
Warning
Not blocking
Thermostop time-out
before rinse
Button G is blinking red
1) Faulty boiler heating element
2) Check boiler heating contactor
3) Faulty PCB relay
To reset this errors, press button D
Please call Service Center
1) Replace boiler heating element
2) Replace boiler contactor
3) Replace PCB
Alarm 09 BOILER SAFETY
SW
Alarm
Blocking
Boiler safety thermostat
intervention
Button G is xed red
1) Faulty boiler safety thermostat
2) Tripped boiler safety thermostat
To reset this errors, the PCB must
be switched o and then on again
(ON-OFF button).
Please call Service Center
1) Replace boiler safety thermostat
2) Restore boiler safety thermostat