Elicent ELEGANCE 100 EC 2V User manual

Instruction Manual
COD. 01141-01 09/17
The equipment must be installed only by a specialised technician!
Read and apply that referred to the following pages before carrying out the installation.
Keep this manual in a safe place.
1
4
Dear Customer,
the product you have purchased is an axial extractor fan for exhausting directly outside through short lengths of ducting and is
suitable for wall or ceiling installation. To ensure optimum operation and guarantee a long life, please read this manual carefully that
explains how to effectuate a correct installation and to use and maintain the product properly. Following all the instructions ensures
reliability and long life, both mechanically and electrically.
The manufacturer declines any responsibility for damages caused to persons or things deriving from the lack of observ-
ance of the following described instructions.
The product is constructed using state of the art technology and respects the standards in force regarding electrical equipment. It
conforms with the EMC European Directive in force regarding radio interference suppression and electro-magnetic compatibility.
Installation and usage instructions
WARNING: Serious injury or death can be caused if these instructions are
not applied!
Do not use this product for uses that are different from those for which it has been de-
signed.
-
recycling norms in force in your country.
This appliance can be used by children aged from 8 years and above and persons with
-
ge if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without su-
pervision.
The means of disconnection from the supply mains must have a contact separation
in all poles and must provide full disconnection under overvoltage category III condi-
tions.
-
stances and vapours, such as alcohol, insecticides, petrol, etc.
The product can be connected to the supply mains only if the voltage and the frequency
of the supply mains correspond to those written in the rating label.
In the case of malfunction, anomaly or any type of fault disconnect the appliance from
for repairs.
norms in force regarding electrical systems.
-
ation of fumes coming from the combustion of stoves or other combustion devices. It
must discharge directly outside the building.
9
10 11
MAINTENANCE
elicent
OFF
ON
TROUBLESHOOTING
DISMANTLING AND RECYCLING
of old products in normal domestic waste material.
100 EC 2V
EN
In case of incorrect or doubtful translation, only the Italian text applies (Translation of the original instructions).
Maico Italia S.p.A.
Tel +39 030 9913575 Fax +39 030 9913766
Maximum speed selection
Adjusting humidity thresholds and timers
To adjust the humidistat and timer trimmers, remove the front cover of the fan to access the trimmers.
a higher level of relative humidity.
to decrease it.
Activation / Deactivation DELAY ON-TIMER
Jumper DELAY-ON TIMER
Disable
Jumper 3 Enable
TM HY
NL
X 1 2 3
TM HY
NL
X 1 2 3
TM HY
NL
X 1 2 3
PROBLEM CAUSE AND REMEDY
The appliance does not switch on There is no voltage.
The impeller does not turn
TM HY
NL
X 1 2 3
TM HY
NL
X 1 2 3
TM HY
NL
X 1 2 3
Jumper Low speed setting
Jumper 1
Jumper 2

INSTALLATION
100
CLICK
3
5
1
2
98,2 mm
4
6 mm
WARNING: Damage can be caused to the device if the following instructions
are not applied!
possible applications of this product are illustrated in this manual.
-
ance.
-
tures.
For an optimum functioning of the appliance, it is necessary to ensure an adequate re-
circulation of air in the room. Consult the local norms with regards to this.
-
-
WIRING DIAGRAMS
A
!
Ø 3.5 mm
A
8
it is recommended to
drill the pre-set hole
drainage.
H03 VV- F H03 VVH2- F
0,5÷1,5 mm² 0,5÷1,5 mm²
3
2
CEILING INSTALLATION
N
L
N
L
L
N
L
N
9/19/19/19/19/19/19/19/2
FUNCTIONING
Version ELEGANCE 100 EC 2V
performance when required via an external switch.
Version ELEGANCE 100 EC 2V DT
In addition, it is equipped with the delay-on-timer function, which is activated by positioning the second available jumper in the
activates an external switch that will bring it to the maximum speed. It is equipped with the delay-on timer; this means that the
product continues to operate at the continuous speed as long as the user does not activate an external switch. The maximum
speed activation will be delayed by two minutes. If the maximum speed of the switch is turned off before that time, the fan will
continue operating at continuous speed. Conversely, after two minutes of the delay-on timer the product will start to run at full
operating at continuous speed.
Version ELEGANCE 100 EC 2V HDT
SETTINGS
Selection of the continuous low speed
The low speed running 24h can be selected between 2 preset minimum speeds – see below.
6/27
6/1
Other Elicent Ventilation Hood manuals
Popular Ventilation Hood manuals by other brands

EuroKitchen
EuroKitchen PS29 Installation guide and user's manual

VentAHood
VentAHood EUROLINE installation instructions

German pool
German pool RDS Series user manual

VentAHood
VentAHood Ventilation Hood Models Equipped with K250... Owner and maintenance guide

German pool
German pool GPR-DL900 user manual

V-ZUG
V-ZUG DFL6 instruction manual