Barcode Scanner Quick Guide
Reset Defaults
StartB F3 CodeC 99 99 98 36 End
USB HID
StartB F3 CodeC 31 64 00 26 End
RS232
StartB F3 CodeC 41 55 54 84 End
Configurable Prefix/Suffix
One or two prefix or suffix characters can be added and assigned for data
transmission. Use one of the codes below with a 3 code byte sequence that
represents the desired character (see ASCII Conversion Chart, end of document)
for your prefix or suffix. (To add additional prefix/suffix characters, refer to your
Single-Line Configuration Guide.)
Scan the Enter/Exit Programming bar code to begin. Then scan the 3 digit
decimal equivalent of the ASCII character into the appropriate character location
with the code byte bar codes (see Code Bytes, end of document). To save, scan
the Enter/Exit
Programming bar code again.
Example: To add an asterisk (*) as a prefix,
scan the bar codes:
1. Enter / Exit Programming
2. Prefix 1st Char
3. Code Byte 0
4. Code Byte 4
5. Code Byte 2
6. Enter / Exit Programming StartB F3 CodeC 99 99 99 41 End
Enter / Exit Programming
StartB F3 CodeC 90 35 00 87 End
Prefix 1st Char
StartB F3 CodeC 90 36 00 91 End
Prefix 2nd Char
StartB F3 CodeC 90 45 00 24 End
Suffix 1st Char
StartB F3 CodeC 90 46 00 28 End
Suffix 2nd Char
Code Byte
StartB F3 CodeC 0 : End
0
StartB F3 CodeC 1 < End
1
StartB F3 CodeC 2 > End
2
StartB F3 CodeC 3 @ End
3
StartB F3 CodeC 4 B End
4
StartB F3 CodeC 5 D End
5
StartB F3 CodeC 6 F End
6
StartB F3 CodeC 7 H End
7
StartB F3 CodeC 8 J End
8
StartB F3 CodeC 9 L End
9
LASER LIGHT. DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
1.0 mW MAX OUTPUT: 650nM
IEC 60825-1:1993+A1+A2
Complies with 21 CFR 1040.10 and 1040.11
except for deviations pursuant to Laser
Notice No. 50, dated June 24, 2007. LASER RADIATION
Laser Product
This device has been tested in accordance with and complies with IEC60825-1:
1993+A1+A2, EN 60825-1:1994+A1+A2 and 21 CFR 1040.10 and 1040.11,
except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.
CAUTION-Laser light when open. DO NOT STARE INTO BEAM.
CAUTION - use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous laser light exposure.
Elite Scanner
PN: EDM85696-1 Rev A1125.1
Elite reserves the right to make changes in specifications and other information
contained in this document without prior notice, and the reader should in all cases
consult Elite to determine whether any such changes have been made.
The information in this publication does not represent a commitment on the part
of Elite.
Elite shall not be liable for technical or editorial errors or omissions contained
herein; nor for incidental or consequential damages resulting from the furnishing,
performance, or use of this material.
This document contains proprietary information that is protected by copyright. All
rights are reserved. No part of this document may be photocopied, reproduced,
or translated into another language without the prior written consent of Elite.
Copyright 2015 All rights reserved.
Web Address: www.aidcti.com
Disclaimer

Minimum Symbol Length
Minimum Symbol Length specifies the minimum number of characters allowable
for non-UPC/EAN bar codes. Scan the Enter/Exit Programming bar code to begin.
Scan Minimum Symbol Length, then scan the minumum number of characters
allowed using code byte bar codes, below. For example, for a 12-character symbol
length, scan 012. To save, scan the Enter/Exit Programming bar code again.
StartB F3 CodeC 90 18 00 19 End
Enter / Exit Programming
StartB F3 CodeC 99 99 99 41 End
ASCII Conversion Chart
Hex
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
Hex
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
Hex
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
Hex
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
Hex
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
Dec
000
001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
021
022
023
024
025
Dec
026
027
028
029
030
031
032
033
034
035
036
037
038
039
040
041
042
043
044
045
046
047
048
049
050
051
Dec
052
053
054
055
056
057
058
059
060
061
062
063
064
065
066
067
068
069
070
071
072
073
074
075
076
077
Dec
078
079
080
081
082
083
084
085
086
087
088
089
090
091
092
093
094
095
096
097
098
099
100
101
102
103
Dec
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
Char
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
FF
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
Char
SUB
ESC
FS
GS
RS
US
!
“
#
$
%
&
‘
(
)
*
+
,
-
.
/
0
1
2
3
Char
4
5
6
7
8
9
:
;
<
=
>
?
@
A
B
C
D
E
F
G
H
I
J
K
L
M
Char
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
\
]
^
_
`
a
b
c
d
e
f
Char
g
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z
{
|
}
~
UPC-A Transmit Lead Zero
StartB F3 CodeC 10 75 14 77 End StartB F3 CodeC 10 75 04 27 End
on
StartB F3 CodeC 10 75 13 72 End
on
StartB F3 CodeC 10 75 03 22 End
off
UPC-A Tramsmit Number System
StartB F3 CodeC 10 75 11 62 End
on
StartB F3 CodeC 10 75 01 12 End
off
UPC-E Expands to 12 Digits
StartB F3 CodeC 10 75 15 82 End
on
StartB F3 CodeC 10 75 05 32 End
off
off
UPC-E Transmit Lead Zero
Beeper Tones
Notmal Tone
StartB F3 CodeC 31 85 75 73 End
Optional Tone 1
StartB F3 CodeC 31 85 65 23 End
Optional Tone 2
StartB F3 CodeC 31 85 55 76 End
Optional Tone 3
StartB F3 CodeC 31 85 45 26 End
Optional Tone 4
StartB F3 CodeC 31 85 35 79 End
Optional Tone 5
StartB F3 CodeC 31 85 25 29 End
Optional Tone 6
StartB F3 CodeC 31 85 15 82 End
No Beep
StartB F3 CodeC 31 85 05 32 End
Code39
Full ASCII Standard
StartB F3 CodeC 10 02 17 06 End StartB F3 CodeC 10 02 07 59 End
Minimum Symbol Length specifies the minimum number of characters allowable
for non-UPC/EAN bar codes. Scan the Enter/Exit Programming bar code to begin.
Scan Minimum Symbol Length, then scan the minumum number of characters
allowed using code byte bar codes, below. For example, for a 12-character symbol
length, scan 012. To save, scan the Enter/Exit Programming bar code again.
StartB F3 CodeC 90 18 00 19 End
Minimum Symbol Length
StartB F3 CodeC 90 19 00 23 End
Symbol Length Lock
Symbol Length Lock specifies the exact number of characters required for
non-UPC/EAN bar codes. Scan the Enter/Exit Programming bar code to begin.
Scan Symbol Length Lock, then scan three bar codes representing the desired
number of characters using the code byte bar codes, below. For example for a
12-character symbol length lock, scan 012. To save, scan the Enter/Exit
Programming bar code again.
StartB F3 CodeC 11 66 13 39 End
CR = on
StartB F3 CodeC 11 66 03 92 End
CR = off
StartB F3 CodeC 11 66 12 34 End
LF = on
StartB F3 CodeC 11 66 02 87 End
LF = off
StartB F3 CodeC 11 66 10 24 End
Tab = on
StartB F3 CodeC 11 66 00 77 End
Tab = off
Suffix