manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elkay
  6. •
  7. Refrigerator
  8. •
  9. Elkay ECU8 1D Series Installation manual

Elkay ECU8 1D Series Installation manual

ECU8*1D, *2D, *3D
98059C (9/04)
TUBE IS SECURED
IN POSITION
SIMPLY PUSH IN
TUBE TO ATTACH
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
1. Insure proper ventilation. In fully recessed drinking fountains be sure condenser faces louver panel and is
within 1/2" (13 mm) of louver panel when panel is in place.
2. Water inlet is 3/8" (10 mm) O.D. unplated tube connector. Contractor to supply connections as required.
3. Connecting lines to be made of unplated copper. Thoroughly flush all lines to remove all foreign matter before
connecting to cooler.
4. Connect cooler to building supply with a shut-off valve and install a 3/8" (10 mm) water line between the valve
and cooler. Remove burrs from outside of water line. Insert water line into bulkhead union until it reaches a
positive stop, approximately 3/4" (19 mm).
5. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial
plate. Never wire the compressor directly to the power supply.
The grounding of electrical equipment such as telephone, computers, etc., to water lines is a common procedure.
This grounding may be in the building, or may occur away from the building. This grounding can cause electrical
feedback into a water chiller, creating an electrolysis which causes a metallic taste or an increase in the metal
content of the water. This condition is avoidable by using the proper materials indicated below. Drain fittings which
are provided by the installer should be plastic to electrically isolate the chiller from the building plumbing system.
Temperature Control: Factory-set for 50°F water (± 5°) under normal conditions. For colder water, adjust screw
on item no. 5.
Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose, or vacuum
cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the overload
protector.
Lubrication: Motors are lifetime lubricated.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring
seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while pulling on the
tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4.
INSTALLATION
IMPORTANT! INSTALLER PLEASE NOTE:
TROUBLE SHOOTING & MAINTENANCE
START-UP
1. Open supply line valve.
2. Purge all air from all water lines by operating bubbler valve of fountain to which cooler is connected. A steady
stream flow assures that all air is removed.
3. Rotate fan blade to assure proper clearance and free action.
4. Connect to proper electrical power.
WIRING DIAGRAM
INSTALLATION, CARE & USE MANUAL
Refrigeration Package
ECU8*1D, *2D, *3D
98059C (9/04)
ELKAY MANUFACTURING COMPANY2222 CAMDEN COURTOAK BROOK, IL 60523630.574.8484
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
DESCRIPTION
66534C
56237C
66576C
70841C
31513C
36094C
36158C
35768C
35659C
19037000
101516143550
100806740570
20282C
31490C
70018C
30664C
66703C
66743C
36208C
1
2
3
4
5
6*
7
8
9
10
11
12
13
14
15
16
17
18
19
PART NO.
EVAPORATOR
SHROUD
HEAT EXCHANGER
UNION - BULKHEAD
COLD CONTROL
COMPRESSOR SERV. PAK
OVERLOAD
COVER - RELAY
RELAY
CLIP - COMP MTG
STUD - COMP MTG
GROMMET - COMP MTG
BRACKET - FAN MTG
FAN MOTOR
NUT
FAN BLADE
DRIER
CONDENSER
POWER CORD
ITEM NO.
PARTS LIST
1
3
19
2
5
10, 11, 12
6
18
17
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY REPLACE
WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: ALL CORRESPONDENCE PERTAINING TO ANY OF THE ABOVE
WATER COOLERS OR ORDERS FOR REPAIR PARTS MUST INCLUDE
MODEL NO. AND SERIAL NO. OF COOLER, NAME AND PART NO. OF
REPLACEMENT PART.
7, 8, 9
4
DESCRIPTION
36092C
36085C
36174C
36195C
36050C
31431C
31430C
31506C
6*
7
9
14
19
PART NO.
COMP SERV. PAK (60 HZ)
COMP. SERV. PAK (50 HZ)
OVERLOAD (60 HZ)
OVERLOAD (50 HZ)
RELAY (50/60 HZ)
FAN MOTOR (60 HZ)
FAN MOTOR (50 HZ)
POWER CORD (50/60 HZ)
ITEM NO.
220V 50/60HZ PARTS LIST
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
13
14, 15
16

This manual suits for next models

2

Other Elkay Refrigerator manuals

Elkay EZ8WS Series User manual

Elkay

Elkay EZ8WS Series User manual

Elkay ECH8 Installation manual

Elkay

Elkay ECH8 Installation manual

Elkay ECH8 2MQ Series Installation manual

Elkay

Elkay ECH8 2MQ Series Installation manual

Elkay ECU8 1A Series User manual

Elkay

Elkay ECU8 1A Series User manual

Elkay ECU8 1G Series Installation manual

Elkay

Elkay ECU8 1G Series Installation manual

Elkay ECP8 Installation manual

Elkay

Elkay ECP8 Installation manual

Elkay ECH8GRN Installation manual

Elkay

Elkay ECH8GRN Installation manual

Elkay EFRC8C-A Installation manual

Elkay

Elkay EFRC8C-A Installation manual

Elkay ERW20-1B User manual

Elkay

Elkay ERW20-1B User manual

Elkay ECH8-1 Installation manual

Elkay

Elkay ECH8-1 Installation manual

Elkay ER30 User manual

Elkay

Elkay ER30 User manual

Elkay ECU8*1A User manual

Elkay

Elkay ECU8*1A User manual

Elkay ECH8-1 Installation manual

Elkay

Elkay ECH8-1 Installation manual

Elkay ECH8 Installation manual

Elkay

Elkay ECH8 Installation manual

Elkay ECH8-1E Installation manual

Elkay

Elkay ECH8-1E Installation manual

Elkay ECH8 2MQ Series Installation manual

Elkay

Elkay ECH8 2MQ Series Installation manual

Elkay ERS1-2F Installation manual

Elkay

Elkay ERS1-2F Installation manual

Elkay ECU8 1E Series Installation manual

Elkay

Elkay ECU8 1E Series Installation manual

Elkay ECP8-1 User manual

Elkay

Elkay ECP8-1 User manual

Elkay ERS1-1D Installation manual

Elkay

Elkay ERS1-1D Installation manual

Elkay ECU8*1C Installation manual

Elkay

Elkay ECU8*1C Installation manual

Popular Refrigerator manuals by other brands

Kenmore 795.77192600 Service manual

Kenmore

Kenmore 795.77192600 Service manual

Dometic Tundra TJ18 Installation & operating instructions

Dometic

Dometic Tundra TJ18 Installation & operating instructions

Vestfrost VF 473 EBH Instruction booklet

Vestfrost

Vestfrost VF 473 EBH Instruction booklet

Zanussi PLB2400 Instructions for the use and care

Zanussi

Zanussi PLB2400 Instructions for the use and care

iGenix IG347FF Instructions for use

iGenix

iGenix IG347FF Instructions for use

Husky Glass Door Drinks Cooler Instruction manual and users guide

Husky

Husky Glass Door Drinks Cooler Instruction manual and users guide

Smeg FAB32NES7 Information sheet

Smeg

Smeg FAB32NES7 Information sheet

Midea HD-332RWEN Service manual

Midea

Midea HD-332RWEN Service manual

GE CustomStyle GSC23LGQ Specifications

GE

GE CustomStyle GSC23LGQ Specifications

Whirlpool 4ET20ZK Use and care guide

Whirlpool

Whirlpool 4ET20ZK Use and care guide

Candy ONE DOOR user manual

Candy

Candy ONE DOOR user manual

Hanseatic HEKS17754GEW user manual

Hanseatic

Hanseatic HEKS17754GEW user manual

KRAFT KF-DF340W user manual

KRAFT

KRAFT KF-DF340W user manual

JUNO JGI9440 operating instructions

JUNO

JUNO JGI9440 operating instructions

Gram KF 310-01 Instructions for use

Gram

Gram KF 310-01 Instructions for use

Whirlpool WD5600S Use and care guide

Whirlpool

Whirlpool WD5600S Use and care guide

Bosch KSV33VWEP Instructions for use

Bosch

Bosch KSV33VWEP Instructions for use

Danby DCR032A2WBUD1 Owner's use and care guide

Danby

Danby DCR032A2WBUD1 Owner's use and care guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.