Emerald HOME 60 User manual

OPERATING MANUAL
EMERALD HOME 60
DEVICE
FOR FRESH WATER PURIFICATION AND ELECTROCHEMICAL TREATMENT

1
CONTENTS
1. INTRODUCTION .......................................................................................................................2
2. INFORMATION ABOUT ANTIOXIDANT WATER - CATHOLYTE ...............................3
Theoretical concepts ........................................................................................................................................ 3
Practical application of catholyte .................................................................................................................... 3
3. PRINCIPLES OF WATER TREATMENT .............................................................................5
The main stages of water treatment in EMERALD Device ............................................................................ 7
4. PRECAUTIONARY MEASURES ............................................................................................8
5. DEVICE FEATURES ...............................................................................................................10
6. DELIVERY SET .......................................................................................................................11
7. DEVICE CONNECTION .........................................................................................................13
Description of the main elements on the EMERALD Device casing ........................................................... 13
General rules for handling John Guest® type quick-release fittings ............................................................. 14
Connecting EMERALD Device under sink with clean water tap ................................................................. 16
Connecting EMERALD Device to the electric network ............................................................................... 21
8. DEVICE OPERATION ............................................................................................................22
Basic operating modes .................................................................................................................................. 22
EMERALD Device functioning in OPERATION mode .............................................................................. 23
Water flow setting ......................................................................................................................................... 24
The Device operation indication ................................................................................................................... 24
9. DEVICE MAINTENANCE ......................................................................................................25
Preparing the EMERALD Device for FLUSHING mode ............................................................................ 26
Preparing the citric acid flushing solution .................................................................................................... 26
Connection diagram of EMERALD Device in FLUSHING mode .............................................................. 27
FLUSHING mode ......................................................................................................................................... 28
Mud filter maintenance ................................................................................................................................. 30
10. TROUBLESHOOTING GUIDE .........................................................................................31
11. WARRANTY .........................................................................................................................32
12. TRANSPORT AND STORAGE ..........................................................................................33
13. ACCEPTANCE AND SALE CERTIFICATE ...................................................................34
APPENDIX №.1. POST FILTER CONNECTION .......................................................................35
APPENDIX №.2. CONNECTING EMERALD DEVICE ABOVE THE SINK .........................37
APPENDIX №3. CERTIFICATES .................................................................................................41

2
Important! Before using the EMERALD HOME 60 Device (hereinafter referred to as
«EMERALD Device» or «Device»), please carefully study this Operating Manual. With
careful use and compliance with the requirements specified in this Operating Manual, the
EMERALD Device will serve you for many years.
1. INTRODUCTION
Congratulations on your purchase of the EMERALD HOME 60 Device for water purification
and electrochemical treatment. You have invested wisely in the well-being of your family, and you
have also taken a very important step towards improving your health!
EMERALD HOME 60 Device is a professional compact system to produce from ordinary tap
water in flow-through mode pure drinking water with antioxidant properties (CATHOLYTE),
purified from microbes and microbial toxins, iron, manganese, hydrogen sulfide, heavy metal ions
and harmful organic compounds (including herbicides, pesticides, hormones, antibiotics,
antidepressants). Antioxidant water enriched with molecular hydrogen using electrochemical
activation (ECA) technology, has a beneficial effect on the entire body, normalizing metabolism and
the functioning of internal organs, cleansing them from toxins, strengthening the immune system,
and toning up the whole body.
EMERALD HOME 60 Device is used in apartments, offices, country houses, cottages, fitness
centers and spas to obtain clean and biologically beneficial antioxidant drinking water.
EMERALD HOME 60 Device is certified both in Russia and abroad, including European CE
certificate of conformity, European ROHS declaration (environmental certificate), ISO 9001 quality
management system certificate, hygiene certificate (expert report) of Rospotrebnadzor, EAC
certificate of conformity, GOST R certificate of conformity.
EMERALD HOME 60 Device is developed jointly with the Vitold Bakhir Institute of
Electrochemical Systems and Technologies, which is the world's main scientific center in the field
of electrochemical activation. Many years of experience and modern discoveries, as well as the
direct participation of V.M. Bakhir, Doctor of Technical Sciences, professor, have made it possible
to combine the most advanced water purification and activation technologies in the EMERALD
HOME 60 Device.

3
2. INFORMATION ABOUT ANTIOXIDANT WATER - CATHOLYTE
Theoretical concepts
Electrochemically activated catholyte is antioxidant water with pronounced electron-donor
properties. Catholyte is obtained from fresh water, in which powerful unipolar action (in the double
electric layer at the cathode of the electrochemical module) causes formation and storing of
metastable products of cathode electrochemical reactions, in particular, molecular ions НО2¯, О2¯,
ОН¯.
Electrochemically activated catholyte exhibits an electron-donor ability, i.e., it is a strong
reducing agent and reduction catalyst in various physicochemical reactions, including biochemical
ones. Catholyte provides for effective neutralization of toxic forms of active oxygen, including free
radicals, and restoration of the optimal balance of oxidative and reduction reactions (REDOX-status)
of the body in the intercellular fluid and in cells, which is directly related to the correct course of all
fundamental life processes of the body.
Practical application of catholyte
Electrochemically activated catholyte is one of the best antioxidants. Antioxidants found in
foods, vitamins or dietary supplements do not give a person proper protection. Due to their large
size, their molecules are not able to penetrate into cells and neutralize toxic oxidants (including free
radicals).
Antioxidant water from EMERALD HOME 60 Device has a beneficial effect on the entire
body, normalizing metabolism and the functioning of internal organs, cleansing toxins, and also
strengthening the immune system, improving memory and toning up the body.
Antioxidant water has a positive effect on the body when consumed as part of a regular diet and
protects against the action of strong toxic oxidants. The mechanism of action of antioxidant water is
based on the transfer of protective electron-donor properties to the body's internal environments,
helping the body's internal antioxidant system to cope with excessive exposure to various oxidative
factors of technogenic origin (polluted air, poor quality of drinking water and food, stress and
overwork, alcohol and cigarettes). Catholyte stimulates tissue respiration, which enhances the action
of vitamins and chemical antioxidants in the body. Antioxidant water also weakens the effect of
ionizing radiation, i.e. exhibits radioprotective properties characteristic of antioxidants. Antioxidant
water improves passive immunity and general condition of the body, improves the functioning of the
gastrointestinal tract and urinary tract, and normalizes blood counts.
Water treated in EMERALD HOME 60 Devices, like any natural antioxidant water, retains its
electron-donor properties for no more than a day from the date of obtaining. After this period, the
redox potential (ORP) of the treated water returns to the original ORP values of non-activated water,
on average, in the range (+100) ÷ (+250) mV, SCE. When boiling, the electron-donor properties of
antioxidant water also decrease. Antioxidant water produced in the EMERALD Device should be
stored for no more than a day in glass containers with a closed lid, away from direct sunlight and
heat sources.

4
SOME APPLICATIONS OF CATHOLYTE
Consuming as part of a normal diet - The human body is more than 70% water. Water plays
the most important role in the life of the human body. An adult needs to consume about 2 or 3 liters
of water per day to maintain the normal functioning of the body.
Cooking - food on antioxidant water is cooked faster and retains more beneficial properties.
Antioxidant water is great for soaking fruit, vegetables, fish and meat - due to its strong extraction
properties, catholyte actively removes harmful chemicals from foods, such as growth hormones and
antibiotics.
Making drinks - in addition to drinking antioxidant water from EMERALD Device, you can
enhance the antioxidant effect due to synergistic phenomena and make antioxidant drinks using
natural antioxidants - freshly squeezed juices of carrots, apples, various berries, by adding
antioxidant water from EMERALD Device to them. Herbal teas prepared with this water acquire a
special taste and aroma. Ice cubes made of frozen antioxidant water will give the drink an extra
benefit.
Air humidification - antioxidant water is useful in the form of a mist when used in
humidifiers. Humidified air with microdrops of antioxidant water, having the properties of a
reducing agent, produces a beneficial effect on the respiratory and cardiovascular systems, prevents
asthma attacks and allergic diseases.
Cosmetic purposes - for cosmetic purposes, antioxidant water is useful for washing, in the
form of ice cubes for wiping the face, or in the form of a spray to moisturize the skin. Moisturizing
masks based on antioxidant water will have a special effect.
Pets, plants and seeds - pets will prefer antioxidant water to regular tap or bottled water. The
use of water from the EMERALD Device for watering houseplants or germinating seeds will
promote their accelerated growth and development.
Important!
The latest technology in the EMERALD Device allows you to get clean and healthy antioxidant
water while maintaining a neutral acid-base balance (pH level). pH neutral antioxidant water is
suitable for regular consumption as part of a normal diet. Due to the similarity with the internal
environment of a human, such water is instantly absorbed by the body and holistically restores it.
EMERALD HOME 60 Device is not a medical device. Before using catholyte for preventive or
therapeutic purposes, consult a specialist. The information on the properties and methods of using
catholyte presented in this section is for reference only and does not apply to medical reports.

5
3. PRINCIPLES OF WATER TREATMENT
The EMERALD Device is high performance and runs on cold tap water, producing 40 to 60
liters of purified antioxidant drinking water (catholyte) per hour.
EMERALD Device ensures high quality of drinking water purification due to the consistent
combination of water activation in electrochemical modules and the use of auxiliary
environmentally friendly filter elements. The main elements of the EMERALD Device are 2 (two)
MB-11 type electrochemical modules (diaphragm flow-through electrochemical Bakhir modular
elements), in which oxidation reactions take place at the anode and reduction reactions at the
cathode (Fig. 1). Auxiliary elements in the Device are a catalytic filter and an electrokinetic filter. A
distinctive feature of EMERALD Device is the absence of replaceable and wear parts.
All processes of water purification and electrical treatment in Device are as close as possible to
what happens to water in wildlife. It has become possible to repeat the natural processes of water
purification and treatment due to the creation of reliable electrochemical modules, which are the
main elements of the system. The modules consist of two flow-through chambers: anode and
cathode. It is in these chambers that, under the influence of a positive current on the anode and a
negative current on the cathode, the water treatment processes suggested by nature are reproduced.
In the anode chamber of the module oxidative reactions take place, during which microbes and
microbial toxins are destroyed. In nature, a similar process of antimicrobial protection, phagocytosis,
has been occurring in all living organisms for millions of years without any failures. Also, in the
anode chamber, harmful organic compounds (including hormones and antibiotics), iron, manganese
and hydrogen sulfide are oxidized.
In the cathode chamber, reduction reactions take place during which water again acquires
useful antioxidant properties due to enrichment with hydrogen. In nature, similar processes occur
during the contact of spring water with rocks, as well as during phase transitions in the process of
melting glaciers. Also, cathode water treatment can effectively remove heavy metals.
The auxiliary catalytic filter consisting of natural coal of the highest standard (grade A
hydroanthracite) is used to purify water from oxidized organic and organochlorine compounds
(including herbicides, pesticides, surfactants, phenols, antibiotics, antidepressants, hormones).
The auxiliary electrokinetic filter, consisting of the purest natural mountain quartz, is an
environmentally friendly analogue of a mechanical fine filter and serves to purify water from
mechanical impurities, heavy metal hydroxides, oxidized forms of iron, manganese, hydrogen
sulfide.
Fig. 1. A new generation MB-11 type electrochemical module, appearance.

6
Useful information!
All water purification and activation processes in EMERALD Devices are as close as possible
to what happens to water in living Nature, since the mechanism of fresh water purification in Nature
is represented by two main processes: redox reactions and filtration.
Therefore, in EMERALD Devices the combination of electrochemical anode and cathode water
treatment with environmentally-friendly filter elements requiring no replacement provides deep
water purification from microbes, microbial toxins, biofilms, heavy metals, iron, manganese,
hydrogen sulfide and harmful organic compounds.
The safety of water treatment using ECA technology is ensured by the complete absence of any
chemicals in EMERALD Devices. MB-11 type electrochemical modules in which electrical
treatment of water takes place, exchange only electrons with water, taking them from the water in
the anode chamber, where oxidative reactions take place and the water is enriched with oxygen, and
introducing the electrons into the water in the cathode chamber, where reduction reactions take place
and the water gets enriched with hydrogen.
This allows the catalytic and electrokinetic filters to work in «clean condition». In the hydraulic
scheme of the EMERALD Device, they are located after the anode destruction of microbes,
microbial toxins and biofilms, which significantly increases their efficiency and service life.
Therefore, the filter elements in the EMERALD Device are protected from microbial growth,
fouling with harmful biofilms and water pollution by microbial toxins!
It is important to note that EMERALD Device has no consumables or wear parts.
Electrochemical modules and auxiliary filter elements (catalytic filter and electrokinetic filter) do
not require periodic replacement under the operating conditions described in this Operating Manual.

7
The main stages of water treatment in EMERALD Device
Fig. 2. Anode chamber.
Stage 1. Anode chamber of the MB-11 electrochemical module
u Destruction of microorganisms, microbial toxins and
biofilms in the water flowing through the anode chamber of the
electrochemical module;
u Oxidative destruction of organic compounds, such as
herbicides, pesticides, antibiotics, hormones, antidepressants,
surfactants, phenols, petroleum products;
u Water purification from iron, manganese and hydrogen
sulfide due to instant oxidation and subsequent filtration;
u Water enrichment with oxygen.
Fig. 3. Catalytic filter.
Stage 2. Catalytic filter
u Water purification from a wide range of organic and
inorganic dissolved impurities after oxidative destruction in the
anode chamber of the module;
u Water purification from free chlorine and organochlorine
compounds;
u Water taste improvement and elimination of unpleasant
odors, including through the anode removal of phenols and
hydrogen sulfide.
Fig. 4. Cathode chamber.
Stage 3. Cathode chamber of the MB-11 electrochemical module
u Water treatment in the cathode chamber of the
electrochemical module imparting antioxidant (electron donor)
properties to water, reducing the water redox potential to the zone
of reduction values;
u Water purification from heavy metal ions converted into
insoluble hydroxides to be subsequently removed on an
electrokinetic filter;
u Microelements useful and necessary for human body are
preserved in water: calcium, magnesium, sodium, potassium,
lithium, iodine;
u Water enrichment with hydrogen;
Fig. 5. Electrokinetic filter.
Stage 4. Electrokinetic filter
u Final purification of water from mechanical impurities,
hydroxides of heavy metals, iron, manganese, hydrogen sulfide;
u Guaranteed water clarity, removal of turbidity and
impurities.

8
4. PRECAUTIONARY MEASURES
u For normal operation of the EMERALD Device, it is necessary to comply with the
requirements for its operation and maintenance specified in this Operating Manual.
u Before you start using the Device, please read this manual carefully. If you have any
questions regarding the connection or operation of the EMERALD Device, please contact our
authorized dealers for advice or call our customer service.
u Device is intended for purification and electrical treatment of only cold drinking water
from centralized water supply systems, corresponding to SanPiN 2.1.4.1074-01!
u If the tap water does not meet the requirements of SanPiN 2.1.4.1074-01, or if there are
visible suspensions, turbidity and rust flakes in the tap water, it is necessary to use a preliminary
water purification system before inlet to the Device, purchaseable immediately with the Device (see
Table 6), or to be ordered separately.
u Do not use the Device to treat microbiologically unsafe water or water of unknown origin
without appropriate pre-disinfection. If you have a weakened immune system or if you require
absolutely pure water for medical reasons, please consult your doctor before using the Device.
u Do not run warm or hot water through the Device, as this may damage it (see DEVICE
OPERATION section).
u Do not use for food purposes the first 15 liters of treated water immediately after
connecting the Device or after flushing the Device with citric acid.
u To ensure the declared water treatment parameters, it is recommended not to use and drain
the first 2 liters of purified water in the OPERATION mode (approximately 2 minutes) when the
Device is idle for more than 10 hours. If the Device is idle for a long time (more than 72 hours), the
first 15 liters of purified water in the OPERATION mode should also be drained (approximately 15
minutes of Device operation).
u The Device is not intended for use by children, people with physical and mental
disabilities, lacking the necessary experience and knowledge, except in cases of direct instruction by
a person responsible for their safety.
u When using the electrical system, basic safety precautions should always be followed to
reduce the risk of fire, electric shock and/or personal injury.
u Before operating the Device, make sure that all hydraulic and electrical connections are
secure. Do not leave the running Device unattended;
u Materials a plumber uses for sealing the joints must not enter the Device. Avoid adding
vegetable oil, petroleum jelly, or other lubricants, solvents, ammonia, alcohols, or strong cleaning
solutions to the system. They can seriously damage the Device.
u Regular maintenance of the EMERALD Device should be carried out to wash the filter
elements and electrochemical modules (see DEVICE MAINTENANCE section).

9
Electrical safety measures:
u The assemblage of the electrical outlet to connect the Device to the electric network must
be carried out by qualified electricians in accordance with the laws in force in your country of
residence.
u To prevent the risk of electric shock, do not place the Device near water or other liquid
substances. The socket should not be located directly above the sink or in any other place where
water can enter it. Before connecting to the power supply, make sure that the Device and all its
elements are dry. During operation, all elements of the EMERALD Device must be dry and not
leaking.
u For the proper functioning of the EMERALD Device, your outlet must be uninterrupted,
have a working ground contact and be connected through a residual current device (RCD) or a
differential circuit breaker with a rated leakage current of 30 mA!
u Be sure to disconnect the Device from the power supply during long breaks in operation.
Do not use any other power supply or adapter in place of the supplied power cord. Check the power
cord, power plug, and the Device itself for damage. If any damage is found, please contact the
nearest service center for examination or repair of the Device.
u Incorrect connection to the electric network supply can lead to the risk of electric shock.
u In order to avoid accidents, it is strictly forbidden to carry out any repair/maintenance
work without disconnecting the Device from the electric network!
Additional Security Measures:
u Use only spare parts approved by the manufacturer.
u Do not use the Device for purposes other than those intended. Do not use the Device
outdoors. Do not use the Device for water desalination.
u Do not disassemble or repair the Device yourself. Contact an authorized service center. In
order to reduce the risk of fire or electric shock, it is strongly recommended not to disassemble the
electronic components of the Device.
u Avoid rough handling of the Device, do not drop or hit it. Do not store or transport the
Device with residual water at an ambient temperature below 0°C. Use Device only in vertical
position.

10
5. DEVICE FEATURES
Table 1. Specifications
Recommended productivity, no more than, liters per hour
60
Consumed electrical power, not more than, W
60
Specific electricity consumption, not more than W* h/l
1.0
Supply voltage - standard socket with grounding (for adapter), V.
110 - 220
Power supply frequency, Hz
50 - 60
The number of electrochemical modules of MB-11 type, pieces
2
Overall dimensions (excluding inlet and protruding parts), WxHxD, mm
140х353х121.5
Gross weight, kg
5.3
Net weight, kg
3.0
Table 2. Processing parameters of water purification *
Table 3. Parameters of catholyte and anolyte in terms of ORP and pH *
The reduction of the ORP of the catholyte relative to the ORP of the source
water, mV, SCE
(-250)…(-700)
The increase in the pH of the catholyte relative to the pH of the source water,
pH units
0.5 - 2.0
Table 4. Operating conditions
Ambient temperature, °C
+5…+40
Relative air humidity (at 25 °С), no more than, %
80
Tap water temperature, °C
+1…+30
Temperature of flushing solution of citric acid, not more than, °C
+70
Water line pressure, bar
1 - 5
Total dissolved solids (TDS) of supplied tap water, mg/l
100 - 400
pH of supplied tap water
6 - 9
* The averaged parameters are given. In each specific case, the results of water treatment are individual in nature and differ from each other due to the
different physical and chemical composition and the level of contamination of the treated water.
Efficiency of anode oxidation of divalent iron ions at their concentration in
source water of 3 mg/l, %
92 - 95
Efficiency of catalytic conversion of chlorine-oxygen oxidants into hydroper-
oxides in the catalytic filter, %
60 - 70
Efficiency of conversion of trivalent iron ions into hydroxide at their concen-
tration in source water of 0.1 mg/l, %
80 - 90
Reduction of permanganate oxidizability of water at the concentration in the
source water of 10 mg/l, %
70 - 85
Efficiency of removal of hydroxides of heavy metals and iron on the electro-
kinetic filter at their concentration in source water of 0.5 mg/l,%
80 - 90
Disinfection of water at 300 colony-forming units (CFU) per 1 ml in source
water, %
99

11
6. DELIVERY SET
Table 5. Delivery Set
1.
EMERALD HOME 60 Device.
1
2.
Power supply (adapter), 24V, 2.5A, 60W.
1
3.
Network cable with IEC320 C14 plug for
connecting the power supply to the electric
network.
1
4.
EMERALD HOME flushing tank with
connection fittings.
1
5.
T-bend with a ball valve for connection to
the water supply line with connections: M
G1/2" (male thread) – F G1/2" (female
thread) - 1/4" tube.*
1
6.
Clean water tap with a set of connection
fittings: 1 pc. fitting F G7/16" – 1/4" tube).
1
7.
Mud filter, a set of fittings for connecting
the preliminary water purification system:
1 pc. elbow fitting 1/4" tube - 1/4" nipple;
2 pcs. fittings M G1/2" - 1/4" tube.
1
8.
Set of connecting tubes, size 1/4", length 4
meters.
1
9.
Fitting kit: 1/4", 3/8" fitting and tube
wrench, set of fixing clip-locks and closing
plugs for 1/4" fittings.
1
10.
Operating Manual.
1
* М (male) – eternal thread, F (female)–internal thread, G1/2" – cylindrical pipe thread 1/2".
No.
Name
Number, pcs.
Appearance

12
Table 6. Auxiliary items purchased separately
No.
Name
Number, pcs.
Appearance
Add. 1
Activated carbon post filter, replaceable,
with quick-release fitting for 1/4" tube with
the connection set: fixing clips for
fastening the post filter, 2 pcs.; self-tapping
screws for mounting fixing clips, 2 pcs.
1
Add. 2
Diverter with M22 connection and 1/4"
tube nipples for connecting the Device
above the sink, with a set of nozzles: М
G1/2" х M22, F G1/2" х M22, М22 х
M24, clamp adapter.
1
Add. 3
Slim Line 10" flask for water pre-treatment
cartridges with a bracket, a wrench and a
set of fittings for connection. The kit in-
cludes 2 pcs. of M G1/2" - 1/4" tube fit-
tings, for connecting the flask with water
supply line and the Device.
1
Add. 4
Mechanical polypropylene filter, 5 mi-
crons, replaceable, for Slim Line 10" flask.
1
Add. 5
Filter with ion-exchange resin for water
softening (removal of hardness salts), re-
placeable, for Slim Line 10" flask.
1
Add. 6
Water iron removal filter, replaceable, for
Slim Line 10" flask.
1
Add. 7
Water mineralizer filter (to increase the
electrical conductivity of water), replacea-
ble, for a 1/4" tube.
1

13
7. DEVICE CONNECTION
Description of the main elements on the EMERALD Device casing
Fig. 6 shows the main elements of the EMERALD HOME 60 Device located on the left and
right side parts of the casing. For the user's convenience, the numbering of elements in fig. 6 and on
the main connection diagrams of the Device in the OPERATION and FLUSHING modes is the
same.
1. EMERALD HOME 60 Device;
2. Plug for connecting the power supply (adapter) to the Device;
5. INLET (TAP WATER) fitting for supplying water to the Device;
6. CATHOLYTE (CLEAN WATER) fitting for purified antioxidant water outlet;
7. FLUSHING fitting for supplying the flushing solution (used only in the FLUSHING mode);
8. Electronic display with ammeter and voltmeter;
9. FLUSHING mode On/Off button;
Fig. 6. Main elements on the EMERALD HOME 60 Device casing.
1
2
5
6
7
8
9

14
General rules for handling John Guest® type quick-release fittings
The connection of the 1/4" tubes to the fittings is done manually. John Guest® type quick-
release connections allow you to repeat the procedures for connecting/disconnecting the tubes and
fittings if necessary. When properly connected, the tube enters the fitting hole by 15-18 mm.
Correctness and reliability of the connection is checked by the return movement of the tube, after
connecting to the fitting. With a force of 8 to 10 kgf, the tube should not be pulled out of the fitting.
Important! Do not apply force when performing these procedures! Proper
connection/disconnection of John Guest® tubes and fittings does not require excessive force!
Fig. 7.1. General principles for connecting the tubes to John Guest® quick-release fittings.
1
2
3
4

15
CONNECTING TUBES AND CLOSING PLUGS TO QUICK-RELEASE FITTINGS.
Connecting tubes or plugs to fittings
is to be performed in accordance with Fig.
7.2:
u Insert the tube by hand into the
fitting hole (1) as far as it will go.
When properly connected, the tube
enters the fitting hole by 15-18
mm;
u Insert a fixing clip-lock (2,3) into
the gap between the sliding collet
ring and the base of the fitting;
u Check that the connection is secure
by moving the tube back. With a
force of 8 to10 kgf, the tube should
not be pulled out of the fitting.
DISCONNECTING TUBES AND
CLOSING PLUGS FROM QUICK-
RELEASE FITTINGS.
Disconnecting tubes or plugs from
fittings is to be performed in accordance
with Fig. 7.3:
u Remove the fixing clip-lock from
the fitting (2);
u Using a hand or a special wrench
(9, Tab. 5), press the collet ring of
the fitting to its base (3);
u While holding the collet ring of the
fitting in the pressed position (3),
pull the tube or plug out of the
fitting by hand (4).
Fig. 7.3. Disconnecting tubes and closing plugs from quick-release
fittings on the Device casing.
1
2
3
4
Fig. 7.2. Connecting tubes and closing plugs to quick-release
fittings on the Device casing.
1
2
3

16
Connecting EMERALD Device under sink with clean water tap
This section describes the basic way to connect the EMERALD Device under the sink, as
recommended by the manufacturer. If you use an alternative method of connecting the EMERALD
Device, you must make sure that the method you choose does not contradict other conditions of this
Operation Manual. In case of violation of the conditions of installation and operation of the
EMERALD Device, warranty claims may be rejected.
EMERALD Device is located without fastening on the bottom shelf of the sink cabinet. To
connect the EMERALD Device under the sink, it is necessary to connect the Device using
connecting hoses (the white tube 1/4" in size and the parts included in the delivery set, in accordance
with the diagram in Fig. 8. The white tube is cut into the required lengths already on installation site.
In domestic conditions, you can cut the tube with a regular kitchen or stationery knife using a cutting
board.
Important! Keep the tubes and plugs remaining after the Device installation! You will need
them to carry out the FLUSHING mode (see DEVICE MAINTENANCE section), as well as to
transport the Device.
Before starting the Device connection procedure, be sure to read the basic principles of
connecting the white tube to fittings, described in the General Rules for Handling John Guest®
Quick-release fittings
Fixed connection of EMERALD Device requires certain skills in working with plumbing
equipment. We recommend using the services of authorized specialists of the company EMERALD
ECOTECHNOLOGIES LLC, a representative of the dealer network or the services of a qualified
plumber of the housing and communal services organization at your place of residence. Do not
install the Device in a place where its maintenance would be difficult. Do not install the equipment
in a place where the Device casing will be exposed to water or direct sunlight.
Turn off the cold water supply valve before connecting, and then open the cold water valve on
the kitchen faucet to relieve pressure in the pipe.
After the Device is fully connected, make sure that all connections are tight. During
installation, pay attention to the fact that the inlet and outlet tubes pass freely along radii to exclude
kinks.

17
CONNECTION DIAGRAM OF EMERALD HOME 60 DEVICE UNDER THE SINK.
u The procedure for connecting the EMERALD Device is carried out in accordance with the
diagram in fig. 8 and consists of the following steps:
u Connection to the cold water supply line (4.5);
u Installation and connection of the clean water tap (6,11);
u Connecting the Device to the electric network (2,3).
1. EMERALD HOME 60 Device;
2. Plug for connecting power supply (adapter) to Device;
3. Power supply (adapter) connected to the electrical network;
4. A t-bend with a ball valve for supplying water to the Device;
5. INLET (TAP WATER) fitting for supplying water to the Device;
5.1. Mud filter with a set of connection fittings for mechanical pretreatment of water (or other
water pretreatment system);
6. CATHOLYTE (CLEAN WATER) fitting for the outlet of purified antioxidant water;
7. FLUSHING fitting for supplying flushing solution (used only in FLUSHING mode);
8. Electronic display with ammeter and voltmeter;
9. FLUSHING ON/OFF Button;
10. Kitchen worktop/sink;
11. Clean antioxidant water outlet tap with a shutoff valve.
* The activated carbon post filter connection diagram is given in Appendix №1.
Fig. 8. Connection diagram of EMERALD Device under the sink with pure water outlet tap.*

18
CONNECTING THE T-BEND WITH A BALL VALVE TO THE WATER SUPPLY LINE.
The connection is made in accordance with the diagram
in Fig. 9:
u Shut off the cold water supply to the sink, and then open
the cold water shutoff valve on the kitchen faucet to
relieve pressure in the pipe;
u When using the flexible connection, unscrew the union
nut of the flexible cold water connection (7), through
which water is supplied to the faucet. Insert a t-bend with
a ball valve (1) into the gap between the cold water line
(3) and the flexible hose. If there are no sealing rings (2)
at the threaded connections, seal the connections (for
example, using Tangit uni-lock ® plumbing thread);
u Insert the union nut from the t-bend nipple (4) through the
1/4" tube (5);
u Push the 1/4" tube up to the stop on the t-bend nipple (4);
u Tighten the union nut to tightly fix the tube on the nipple;
Water is supplied through the t-bend by the valve (6).
For details, see the DEVICE OPERATING section.
Important! When
connecting these elements,
do not overtighten the
connections! This can lead
to a damage of the t-bend
or valve, including a
hidden one (with long-
term consequences). The
amount of plumbing
sealing material used must
not be excessive! In the
event of any mechanical
damage to the connection
node due to improper
installation and use,
warranty claims may be
rejected.
Fig. 9. Connecting Diagram for the t-bend
with a ball valve to the water supply.
Fig. 10. Installation of the t-bend with a ball valve for water supply to the Device.
2
4
5
1
3
7
6

19
CONNECTING PRE-FILTERS BEFORE WATER INLET INTO THE DEVICE.
The delivery set includes a mud filter (Fig. 11.1) with a set of
connection fittings, which serves for preliminary rough mechanical water
purification before being supplied to the Device. Water filtration is carried
out by a stainless steel metal mesh built into the screw-of part of the case
(3, Fig. 11.1). The mud filter is connected in accordance with the diagram
in Fig. 8. When connecting the mud filter, make sure that the direction of
the water flow corresponds to the arrows on its case. Locking blue clip-
locks are installed in all quick-release connections. The two main
connection options are described below:
Option 1. Connection to the gap of the water supply tube (Fig. 11.2):
u The first part of the water supply tube from the t-bend (4, Fig. 8) is
connected to the inlet fitting (1) on the case of the mud filter;
u The second part of the water supply tube is connected from the outlet
fitting (2) on the mud filter case to the INLET fitting (5, Fig. 8) on the
Device;
Option 2. Connection directly to the Device using an elbow fitting
nipple (Fig. 11.3):
u The first part of the water supply tube from the t-bend (4, Fig. 8) is
connected to the inlet fitting (1) on the mud filter case;
u The outlet fitting (2) on the mud filter case is connected with a short
piece of connecting tube to the corresponding fitting of the elbow
fitting (4) with nipple; The nipple of the elbow fitting (5) is connected
to the INLET fitting (5, Fig. 8) on the Device casing. For ease of
connection, the mud filter is immediately supplied assembled with an
elbow fitting.
Important! If the source water does not comply with the requirements
of SanPiN 2.1.4.1074-01, it is possible to install an additional pre-
treatment system instead of the mud filter or before it (purchased
separately, see Table 6). To do this, by analogy with the mud filter, before
the Device the Slim Line 10" flask is connected (Fig. 11.4), into which,
depending on the type of contamination in the source water, various
replaceable filters are installed: polypropylene, carbon, ion exchange or
iron removal filter):
u The necessary filter is installed inside the flask;
u The corresponding threaded parts of the connecting fittings (3.4) are
screwed into the threaded fittings of the flask (1.2). Threaded
connections are sealed;
u In accordance with the arrows of the water flow on the flask case, the
water supply tube from the t-bend (4, Fig. 8) is connected to the water
inlet fitting into the flask (3), and the water outlet fitting from the flask
(4) is connected to the INLET fitting ( 5, Fig.8) on the Device; Blue
fixing clip-locks are installed in all quick-release fittings.
Fig. 11.1 Mud filter (left)
with connection fitting
(right).
1
2
3
4
Fig. 11.2 Mud filter
connected to the gap in the
water supply tube.
Fig. 11.3 Mud filter
connected directly to the
Device.
5
1
2
3
4
Fig. 11.4. Main Slim Line
10" flask with connection
fittings.
Other manuals for HOME 60
2
Table of contents
Other Emerald Water Filtration System manuals
Popular Water Filtration System manuals by other brands

Pura
Pura UV89572 Installation manual & owner's guide

VWR
VWR Avantor 171-1249 instruction manual

Viqua
Viqua Sterilight S1Q-PA owner's manual

Cornelius
Cornelius QLT 180 INSTALLATION & CLEANING INSTRUCTIONS

H2WaterForLife
H2WaterForLife H2 USB Sport PRO II quick start guide

ProSystems
ProSystems 38247 owner's manual

Atlas Filtri
Atlas Filtri K-MATIC Installation, use and maintenance manual

SuperFish
SuperFish Aqua-Flow 75 user manual

ETS-Lindgren
ETS-Lindgren LPRX Series Installation and maintenance manual

Honeywell
Honeywell miniplus FK06 Installation instruction

Sartorius
Sartorius Sartolab RF 150 Sartolab BT 150 quick start guide

Argo-Hytos