Emerald HOME 60 User manual

PASSPORT AND OPERATING MANUAL
EMERALD HOME 60
FOR PURIFICATION AND ELECTRICAL TREATMENT OF FRESH WATER

1
CONTENTS
1. INTRODUCTION. .............................................................................................................. 2
2. INFORMATION ON ANTIOXIDANT WATER. .............................................................. 2
3. WATER PURIFICATION AND ELECTRIC TREATMENT PRINCIPLE. ..................... 3
The main stages of water purification and electric treatment in the EMERALD device. .............................. 5
4. PRECAUTIONARY MEASURES. ..................................................................................... 6
5. DEVICE CONNECTION. .................................................................................................. 8
General rules for handling John Guest® -type quick fittings. ........................................................................ 8
Connecting the EMERALD Device over the sink with a diverter. ................................................................. 9
Connection of the EMERALD device under the sink with a pure water tap. ............................................... 12
Connection of the device to the electric network. ......................................................................................... 16
6. DEVICE OPERATION. .................................................................................................... 17
The EMERALD device operation over the sink with a diverter. ................................................................. 17
Operation of the EMERALD device under the sink with the pure water tap. .............................................. 18
Water flow setting. ........................................................................................................................................ 19
System Operation Indication. ........................................................................................................................ 19
Basic operating modes. ................................................................................................................................. 20
7. DEVICE MAINTENANCE. .............................................................................................. 21
Connection diagram of the device in the FLUSHING mode above the sink with a diverter. ...................... 22
Connection diagram of the device in the FLUSHING mode under the sink with a pure water tap. ............ 23
Citric acid solution preparation. .................................................................................................................... 24
FLUSHING Mode. ........................................................................................................................................ 24
8. TROUBLESHOOTING GUIDE. ...................................................................................... 26
9. WARRANTY. ................................................................................................................... 27
7. TRANSPORTATION AND STORAGE. .......................................................................... 28
10. DEVICE SPECIFICATIONS. ....................................................................................... 29
11. CONTENTS OF DELIVERY. ....................................................................................... 30
12. ACCEPTANCE AND SALES CERTIFICATE. ........................................................... 31
APPENDIX No. 1. CERTIFICATES ........................................................................................ 32

2
ATTENTION! Before using EMERALD HOME 60 Device (hereinafter referred to as
"EMERALD Device", or "Device") please carefully study this passport and operating manual.
With careful use and compliance with all requirements specified in this passport and operating
manual, the EMERALD Device will serve you for many years.
1. INTRODUCTION.
Congratulations on your purchase of the EMERALD HOME 60 household water purification
and electric water treatment device. You have invested wisely in the well-being of your family and
also made a very important step towards improving your health!
The EMERALD device is designed to produce drinking water with antioxidant properties from
ordinary tap water purified from microbes and microbial toxins, heavy metal ions and harmful organic
compounds. Antioxidant water from the EMERALD device has a beneficial effect on the whole body,
normalizes metabolism and the functioning of internal organs, cleanses them of toxins and wastes,
and also strengthens the immune system, improves memory and increases the physical vigor.
The EMERALD device has been developed jointly with the Vitold Bakhir Institute, which is the
main scientific center in the field of electrochemical activation of water. Many years of experience
and modern discoveries of experts from the Vitold Bakhir Institute, as well as the direct participation
of V.M. Bakhir, Doctor of Technical Sciences, professor, have allowed us to combine in the
EMERALD device the most advanced water purification and electrical treatment technologies.
All processes of water purification and electric treatment in the device are as close as possible to
what happens with water in living nature. Repeating the most complex natural processes of water
purification and treatment has become possible due to the creation of highly reliable electrochemical
modules, which are the main elements of the system. The modules consist of two flow-through
chambers: anode and cathode. It is in these chambers that under the influence of positive and negative
currents on the anode and cathode, the processes of water electric treatment suggested by nature are
reproduced.
2. INFORMATION ON ANTIOXIDANT WATER.
The human body is more than 70% water. Water plays the most important role in the life of the
human body. An adult needs to drink about 2 to 3 liters of water per day to maintain normal body
activity.
Antioxidant water from EMERALD device has a positive effect on the body when used as part
of a normal diet. EMERALD antioxidant water protects the body from the effects of strong toxic
oxidizing agents. The mechanism of action of antioxidant water is based on the transfer of protective
antioxidant properties to the internal media of the body, which helps to protect against toxic oxidizing
agents present not only in water, but also in air and in food. Tissue respiration is stimulated, which
enhances the action of vitamins and chemical antioxidants in the body. Antioxidant water also
weakens the effect of ionizing radiation, i.e. it exhibits radioprotective properties characteristic of
antioxidants. Antioxidant water improves passive immunity indicators and the general condition of
the body, improves the functioning of the gastrointestinal tract and urinary tract, normalizes blood
counts.
Water treated in EMERALD devices retains its antioxidant properties for no more than a day
from the date of receipt. After this period, the redox potential (ORP) of the treated water returns to the
initial ORP value of the tap water +150 ÷ + 500mV. Upon boiling, the ORP value of antioxidant water

3
decreases in absolute value, but the water continues to exhibit the properties of a reducing agent. The
water obtained in the EMERALD device should be stored for no more than a day in glass containers
with a closed lid away from direct sunlight and heat sources. Water treated in EMERALD devices
meets the requirements of hygiene standards (see Appendix 1 “Certificates”).
Cooking - food on antioxidant water is cooked faster and retains more beneficial properties.
Antioxidant water is great for soaking fruits, vegetables, fish and meat - due to its properties, such
water actively removes harmful chemicals from products, such as growth hormones and antibiotics.
Making drinks - in addition to drinking antioxidant water from the EMERALD device, you can
enhance the antioxidant effect due to synergies and make antioxidant drinks using natural antioxidants
- freshly squeezed juice of carrots, apples, various berries, by adding antioxidant water from the
EMERALD installation to them. Herbal teas made with this water have a special taste and aroma. Ice
cubes of frozen antioxidant water will give the drink an additional benefit.
Humidification - antioxidant water is useful as a mist when used in humidifiers. Humidified air with
microdrops of antioxidant water, which has the properties of a reducing agent, has a beneficial effect
on the respiratory and cardiovascular systems, prevents asthma attacks and allergic diseases.
Cosmetic applications - for cosmetic purposes, antioxidant water is useful for washing, in the form
of ice cubes for rubbing the face or spraying water in the form of an aerosol to moisturize the skin.
Moisturizing masks on antioxidant water will have a special effect.
Pets and plants - pets will prefer antioxidant water to plain tap or bottled water. Watering indoor
plants with EMERALD water will contribute to their rapid growth and development.
3. WATER PURIFICATION AND ELECTRIC TREATMENT PRINCIPLE.
The EMERALD device is high-performance and works on cold tap water, able to produce from
40 to 60 liters of drinking antioxidant water per hour.
Electrochemical activation technologies in the EMERALD device have allowed combining
highly effective water purification and treatment in order to restore its antioxidant properties.
The EMERALD device provides the highest quality of drinking water due to the sequential
integration of the electric water treatment in the electrochemical module and the use of auxiliary filter
elements. The main element of the EMERALD device is a special electrochemical module (Bakhir
diaphragm flow-through electrochemical module), with oxidative reactions taking place at the anode
and reduction reactions at the cathode. Auxiliary elements in the device are a catalytic filter and an
electrokinetic filter. A distinctive feature of the EMERALD device is the absence of replaceable and
wearing parts.
In the anode chamber of the module, oxidative reactions take place with the destruction of
microbes and microbial toxins, as well as harmful organic compounds. In nature, a similar process of
antimicrobial protection, phagocytosis, has been going on in all living organisms for millions of years
without any failures.
Reduction reactions take place in the cathode chamber, during which water again acquires useful
antioxidant properties (redox potential close to the internal medium of the body). In nature, similar
processes occur during the contact of spring water with rocks, as well as during phase transitions in
the process of glaciers melting.
The auxiliary catalytic filter, consisting of top-quality natural processed coal (grade A
hydroanthracite), serves for the post-treatment of water from oxidized organic and organochlorine
compounds (including herbicides, pesticides, surfactants, phenols, antibiotics, antidepressants,
hormones).

4
An auxiliary electrokinetic filter, consisting of the purest natural mountain quartz, serves for the
post-treatment of water from mechanical impurities, heavy metals, iron, manganese, hydrogen sulfide.
Helpful information!
Water purification and electric treatment in the anode and cathode chambers is highly
efficient and safe. Water treatment processes are identical to natural ones, but at the same time
they are accelerated by tens of thousands of times due to the use of the latest technologies and
electrochemical modules.
Catalytic and electrokinetic filters operate in clean conditions. They are located after the
anodic destruction of microbes, microbial toxins and biofilms, which significantly increases
their efficiency and service life. Therefore, the filter elements in the EMERALD device are
protected against the growth of microbes, fouling with harmful biofilms and water pollution
with microbial toxins!
The latest technologies in the EMERALD device allow producing clean and healthy
antioxidant water, while maintaining a neutral level of acid-base balance (pH level). PH neutral
antioxidant water is suitable for everyday use in regular diets. Due to the similarity with the
internal medium of human body, such water is instantly absorbed by the body and holistically
restores it.
The parameters of the purified antioxidant water are monitored by the instrumental
method, by measuring the pH and the redox potential (ORP) of the treated water using
appropriate instruments. These gages are purchased separately and are not on the delivery list.

5
The main stages of water purification and electric treatment in the EMERALD device.
Fig. 1 The anode chamber
of the module
Stage 1. The anode chamber of the Bakhir electrochemical module
u In water flowing through the anode chamber of the
electrochemical module, microorganisms, microbial toxins and
biofilms are destroyed;
u There is oxidative destruction of organic compounds, such as
herbicides, pesticides, surfactants, phenols, oil products, etc.;
u Iron removal is carried out with the conversion of iron ions
into light 3-valent form for mechanical cleaning;
u Water is given the properties of an active oxygen carrier.
Fig 2 Catalytic filter
Stage 2. Catalytic filter
u At this stage, water is purified from a wide range of organic
and inorganic dissolved impurities that undergo oxidative
degradation in the anode chamber of the module;
u Water is purified from free chlorine and organochlorine
compounds;
u The taste of water improves and the unpleasant odor is
eliminated, including due to the anode removal of phenols and
hydrogen sulfide.
Fig. 3 The cathode chamber of
the module
Stage 3. The cathode chamber of the Bakhir module
u Water treatment in the cathode chamber of the
electrochemical module gives antioxidant properties to water,
reducing the redox potential of water;
u Heavy metal ions are converted to insoluble hydroxides and
subsequently removed on an electrokinetic filter;
u At the same time, all minerals useful and necessary for a
person are stored in water: calcium, magnesium, sodium, potassium,
lithium, fluorine, iodine;
u Water is given the properties of an active hydrogen carrier;
Fig. 4 Electrokinetic filter.
Stage 4. Electrokinetic filter
u Water undergoes final cleaning from mechanical impurities,
hydroxides of heavy metals, iron, manganese, hydrogen sulfide;
u Guaranteed is transparency of water, removal of turbidity and
impurities .

6
4. PRECAUTIONARY MEASURES.
u Important! For normal operation of the EMERALD device, all requirements for its operation
and maintenance specified in this passport and in the operating manual must be observed.
u Before you start using the device, please read all the instructions carefully. If you still have
questions about connecting or operating the EMERALD device, consult our authorized dealers or call
our service department.
u When using an electric device, always follow basic safety precautions to reduce the risk of
fire, electric shock, and/or people’s injury.
u The device is designed for purifying and electric treatment of ONLY COLD DRINKING
WATER FROM CENTRALIZED WATER SUPPLY SYSTEMS CORRESPONDING TO SANPIN
2.1.4.1074-01!
u In the event the tap water does not meet the requirements of SanPiN 2.1.4.1074-01, as well as
in the presence of visible suspensions, turbidity and flakes of rust in the tap water, it is necessary to
use a preliminary water treatment system before inlet in the device.
u Do not use the device for the treatment of microbiologically unsafe water or water of unknown
origin without proper prior disinfection. If you have a weakened immune system or if for medical
reasons you need absolutely clean water, please consult a professional doctor before using the device.
u Do not run warm or hot water through the device, as this may damage it (see the “DEVICE
OPERATION” section).
u Do not use the first 30 liters of purified water for food immediately after connecting the system
or after flushing the system with citric acid. For prolonged shutdowns of the device (more than 1 day),
the first 30 liters of purified water should also be drained.
u To prevent electric shock, do not place electronic components near water or other liquid
substances. The outlet should not be located directly above the sink or any other place where water
can enter it. Before connecting to the power supply network, make sure that the device and all its
elements are dry. During operation, all components of the EMERALD Device must be dry and not
leak.
u The water purification system is not intended for use by children, people with physical and
mental disabilities, with a lack of necessary experience and knowledge, except in cases of direct
instruction by the person responsible for their safety.
u Use only spare parts approved by the manufacturer. Do not use the device with damaged
electrical wires of the power source after breaking their integrity.
u Do not use this device for other purposes. Do not use the device outdoors. The device is
intended for domestic use only. Do not use the device for water desalination.
u Do not disassemble or repair the device yourself. Contact an authorized service center. In order
to reduce the risk of fire or electric shock, it is categorically not recommended to disassemble the
electronic components of the system.
u Avoid rough handling of the device, do not drop or hit it. Do not store or transport the device
with residual water at an ambient temperature below 0ºС. Use the device in an upright position only.
u Before starting the device operation, make sure all hydraulic and electrical connections are
secure. Do not leave the running device unattended;
u Be sure to disconnect the device from the power supply during prolonged interruptions in
operation. Do not use any other power supplies or adapters in place of the enclosed power supply.
Check the power cord, power plug and the device itself for damage. If any damage is found, contact
the nearest service center for inspection or repair of the device.
u Do not let materials the plumber uses to seal the joints to enter the system. Avoid vegetable
oil, petroleum jelly or other lubricants, solvents, ammonia, alcohols or powerful cleaning solutions
getting into the system. They can seriously damage the device.
u Avoid any liquids (including water) getting on the electrical components of the system.

7
u To connect the power cord, you need a grounded power outlet (socket). If you need to install
a new outlet, this must be done by an electrician with the appropriate permission or certificate issued
in accordance with the current legislation of your country of residence.
u For the proper functioning of the EMERALD Device, your socket must work without
interruption and must have EARTHING!
u Incorrect connection to the power supply can result in a risk of electric shock. Do not replace
the plug yourself.
u Regularly perform maintenance on the EMERALD Device for flushing the filter elements and
the electrochemical module (see the DEVICE MAINTENANCE section).

8
5. DEVICE CONNECTION.
ATTENTION! This section describes the main methods for connecting the EMERALD Device
above and below the sink, which are recommended by the manufacturer. If you use an alternative
method of connecting the EMERALD Device, you must make sure that the method you choose does
not contradict other provisons of this Passport and operation manual. In case of violation of the
installation and operation regulations of the EMERALD Device, claims for warranty may be rejected.
General rules for handling John Guest® -type quick fittings.
Manually connect white tube ¼ to fittings. John Guest® quick fittings allow you to repeatedly
connect/disconnect tubing and fittings.
Important! Do not use force when performing these procedures! Correct connection/disconnection of
John Guest® tubes and fittings is effortless!
Fig. 5. General guidelines for connecting tubing to John Guest®-type quick fittings
u To connect the tube to the fitting:
u Insert the white tube all the way into the fitting hole. With proper connection, the tube enters
the fitting hole by 15-18 mm;
u Check the connection by returning the tube. When the tube moves back, the end ring (collet)
of the fitting extends from the base;
u The fixing lock (blue clip) is inserted into the gap between the end ring (collet) and the base
of the fitting.
u To disconnect the tube from the fitting:
u Temporarily remove the lock (blue clip) of the fitting;
u Press the end ring (collet) of the fitting with the hand or a special key to the base of the fitting
and hold it in this position while pulling the white tube;
u Pull the tube out of the fitting hole.

9
Connecting the EMERALD Device over the sink with a diverter.
The EMERALD device can be located without
fastening on the worktop, or it can be fixed to the wall with
screws, for which there are special suspensions on the rear
wall of the device casing (see Fig. 6). To connect the
EMERALD Device above the sink, you must use the
connecting tubes (white tube ¼ made of food-grade plastic)
and the parts included in the kit. Connect the device in
accordance with the diagram in Fig. 7.
ATTENTION! Before starting the device
connection procedure, be sure to read through the basic
principles of connecting a white tube with fittings described
in the paragraph General rules for handling John Guest®”-
type quick fittings.
Connecting the EMERALD Device requires certain
skills in working with plumbing equipment. We recommend
using the services of authorized specialists of the
EMERALD ECOTECHNOLOGIES LLC, a representative
of the dealer network or the services of a qualified plumber
of the housing and communal services organization at your
place of residence. Do not install the system in a place where
maintenance is difficult.
Before starting the connection, turn off the cold water supply tap, and then open the cold water
tap on the kitchen faucet to relieve pressure in the pipe. Avoid direct sunlight on the surface of the
system casing.
* The presented mounting option is for informational purposes only. The arrangement of elements
on the device may differ from those shown on the photo.
Fig. 6. EMERALD device mounting
option with fixing on the wall near the
sink*

10
EMERALD HOME 60 DEVICE CONNECTION OVER THE SINK DIAGRAM.
Fig. 7. EMERALD Device wiring diagram in OPERATION mode
1.Installation of EMERALD HOME 60 above the sink; 2. Power supply (adapter); 3. A diverter
on the tap with a control; 4. Tap water inlet fitting; 5. Purified water outlet fitting; 6. Plug for
connecting a power source; 7. Plug for connecting the power of the flushing unit; 8. On/off button of
the flushing unit; 9. Sink/worktop. 10. Electronic ammeter / voltmeter

11
INSTALLING THE DIVERTER ON THE TAP.
u To connect the diverter to the tap:
u Remove the regular aerator from the tap;
u Using the necessary nozzles from the delivery set, install the
diverter on the tap;
u To fix the diverter on the tap, press it against the tap and tighten
the ring at the base of the diverter by hand.
u Check that all connections are secure and tight.
During installation, the connecting white tube that comes with
the connection kit is cut into 2 parts (the length of the parts is
selected on the spot). In accordance with the diagram in Fig. 7, the
first segment of the tube connects the diverter to the Water Inlet
fitting on the side of the system; the second segment of the tube connects the Pure Water fitting on
the side of the system to the diverter.
After fully connecting the device, make sure all connections are tight. If you notice water leakage
at the points where the diverter is connected to the tap, at the points where the connecting tubes are
connected to the diverter, or at the places where the tubes are connected to the water inlet and outlet
fittings, disconnect and reconnect them. During installation, pay attention to the fact that the inlet and
outlet tubes pass freely along radii that exclude kinks.
Fig. 8. Tap diverter with a set
of nozzles

12
Connection of the EMERALD device under the sink with a pure water tap.
The EMERALD device is located without fastening on
the lower shelf of the washing cabinet (see Fig. 9), or it is
attached to one of its walls with screws, for which there are
special suspensions on the rear wall of the device casing. To
connect the EMERALD device under the sink, you must use
the connecting hoses (white tube ¼ made of food-grade
plastic) and the parts included in the kit to connect the device
in accordance with the diagram in (Fig. 10).
ATTENTION! Before starting the device connection
procedure, be sure to read through the basic principles of
connecting the white tube with fittings described in the
paragraph General rules for handling John Guest®-type quick
fittings.
Fixed installation of the EMERALD device requires
certain skills in working with plumbing equipment. We
recommend using the services of authorized specialists of the
company EMERALD ECOTECHNOLOGIES LLC, a
representative of the dealer network or the services of a
qualified plumber of the housing and communal services
organization at your place of residence. Do not install the
system in a place where maintenance is difficult.
Before starting the connection, turn off the cold water
supply tap, and then open the cold water tap on the kitchen
faucet to relieve pressure in the pipe. Avoid direct sunlight on
the surface of the system casing.
After fully connecting the device, make sure all connections are tight. During installation, pay
attention to the fact that the inlet and outlet tubes pass freely along the radii that exclude kinks.
Fig. 9. EMERALD device placing
option on the lower shelf of the sink
cabinet.

13
EMERALD HOME 60 DEVICE CONNECTION UNDER THE SINK DIAGRAM.
The procedure for connecting the EMERALD device (Fig. 10) consists of the following steps:
u Connection to the cold water supply line (3) and (4);
u Installation and connection of a clean water tap (5) and (9);
u Connection of the device to the electric network (2) and (6)
Fig. 10. Wiring diagram of the EMERALD device under the sink
1.Installation of EMERALD HOME 60 under the sink; 2. Power supply (adapter); 3.
T-bend with a ball valve, for supplying water to the device; 4. Tap water inlet fitting; 5.
Purified water outlet fitting; 6. Plug for connecting the power source; 7. Plug for connecting
the power of the flushing unit; 8. On/off button of the flushing unit; 9. A tap for clean
drinking water; 10 sink/worktop; 11. Electronic ammeter / voltmeter
During installation, the connecting white tube that comes with the connection kit is cut into 2
parts (the length of the parts is selected on the spot). In accordance with the diagram (Fig. 10): the T-
bend (3) is connected with the first tube section to the “Water inlet” fitting (4) on the side of the
system; the second tube section connects the Pure Water fitting (5) on the side of the system with a
clean water tap (9) installed on the sink/worktop (10).

14
CONNECTING TO THE COLD WATER SUPPLY LINE.
Fig. 11. Connection to the cold water supply line
u Block the flow of cold water to the sink, and then open the cold water tap on the faucet to
relieve pressure in the pipe;
u If necessary, tighten threaded connections.
u Unscrew the nut on the T-bend and put it on the connecting tube;
u Fit the pipe tightly onto T-bend fitting and tighten the nut;
u Check that all connections are secure.
Attention! When connecting these elements, do not overtighten
the connections! This can lead to the destruction of the T-bend or tap,
including a hidden defect (with long-term consequences). The amount
of waterproofing material used (FUM tape, etc.) should not be
excessive! Consult a professional plumber to install these items on a
cold water main. In case of any mechanical damage to the connection
unit due to improper installation and use, warranty claims may be
rejected.
Fig. 12. Ball T-bend with
water supply control tap

15
MOUNTING AND CONNECTING THE PURE WATER TAP.
Drill a hole with a diameter of 12 mm for the tap in the
sink/worktop and install the tap into it (see Fig. 13). Drilling the hole
in the sink should only be done if you are sure the sink will not be
destroyed by this procedure. Particular care should be taken when
drilling holes in ceramic, porcelain, granite, marble, Teflon sinks, as
well as in sinks made of artificial stone and so on. If it is not possible to
make a hole in the sink, the tap can also be installed on the worktop.
Method 1. The classic version
Connect the pure water tap according to the diagram in Fig. 14.
To do so you ought to:
u Put on the threaded shank of the tap a decorative stand
with a rubber gasket;
u Insert the tap into the drilled hole;
u Put plastic and metal lock washers on the threaded shank
from below and screw on the fixing nut.
u To connect the white tube, pass it through the clamping
nut; put a plastic sleeve on the connected end of the tube and
insert a plastic piston into the tube; then insert the tube into the
shank of the tap and tighten the clamping nut until snug.
u Check that all connections are secure.
Method 2. Express version using a quick fitting (recommended option).
u Connect the pure water tap according to the diagram in Fig. 14 down
to item 7D;
u To connect the plastic tube in this version, use a quick fitting for a tap
of the type ¼ thread - tube ¼ (see Fig. 15). To do this, screw the fitting
onto the tap after the 7D nut, and on the other side of the fitting, insert
the plastic tube into the quick fitting. Do not forget to insert the fixing
clip into the sliding ring of the fitting;
u Check that all connections are secure.
Fig. 13. A sample of drilling a
hole for the pure water tap
Fig. 14. Assembly diagram of hydrau-
lic elements of the pure water tap
Fig. 15. Sample assembly of the pure water
tap with quick fitting
WORKTOP

16
Connection of the device to the electric network.
The EMERALD device is connected to the electric network in several stages - see Fig. 16. First
you need to connect the power supply (adapter) to the network cable. Then you need to connect the
power cable to an electrical outlet and insert the plug of the power supply into the power socket of the
EMERALD device in the upper left corner of the side of the casing.
Fig. 16. General view of connecting the EMERALD installation to the mains
Important!
Make sure that the device is connected to the power source of an electrical network with suitable
characteristics (see the DEVICE SPECIFICATIONS section, Table 2).
For the EMERALD Device to function properly, your outlet must be uninterrupted and must be
EARTHED!
It is forbidden to disconnect the working device from the network by pulling the plug of the
power source from the device. This can lead to malfunctioning of the device. Disconnecting the device
from the power supply should only be done by disconnecting the power plug from the outlet!
.
4

17
6. DEVICE OPERATION.
Important! After connecting the EMERALD device, it is necessary to study the operating
rules in detail.
Important! Do not use the first 30 liters of purified water immediately after connecting the
device for food purposes. After long downtimes of the device (more than 1 day), the first 30
liters of purified water should also be drained.
The device is designed for cleaning and electric processing of ONLY COLD WATER
FROM CENTRALIZED WATER SUPPLY SYSTEMS! In the drinking water preparation
mode, do not run warm or hot water through the system, as this may damage it.
Do not use the device for the treatment of microbiologically unsafe water or water of
unknown origin without proper pre-filtration and disinfection.
The EMERALD device operation over the sink with a diverter.
Fig. 17. Water supply using the diverter control.
To turn on the device in the OPERATION mode, it is necessary to open the cold water supply
on the tap, and then gently turn the control on the diverter to a horizontal position (see Fig. 17) so that
cold tap water starts to flow into the device.
Vertical position of the control on the diverter - water is drained into the sink and is NOT supplied
to the device;
Horizontal position of the control on the diverter - water is supplied to the device.
The device turns on automatically as soon as water begins to flow into it. When the device is
switched on in the OPERATION mode, the multifunction LED lights up in one of the corresponding
modes.
Turning off the device also occurs automatically immediately after the cessation of water supply
(after the cessation of water flow in the device). When the device is turned off, the multi-function
LED goes out.

18
Operation of the EMERALD device under the sink with the pure water tap.
WATER SUPPLY THROUGH THE T-BEND WITH A BALL VALVE
To supply water to the device, it is
necessary to smoothly open the
tap on the T-bend (see Fig. 18) so
that cold tap water begins to flow
into the device.
Vertical tap position - no water
supply.
Horizontal tap position - water is
supplied to the device
Important! At high water pressure in the water supply system, a full opening the T-bend tap is
optional. Partial opening of the tap on the T-bend will moderate the overall water flow rate and reduce
the degree of load on the device hydraulic units.
USING THE PURE WATER TAP
To start operating, it is necessary to smoothly open the tap on the T-bend (see Fig. 18).
Next it is necessary:
u To turn on the device, open the shut-off valve on the
pure water tap (see Fig. 10 - “9” and Fig. 19) so that cold water
starts to flow into the device;
u To turn off the device, reverse the operation and close
the shut-off valve so that water stops flowing into the device.
The device turns on automatically as soon as water begins
to flow into it. When the device is switched on in the
OPERATION mode, the multifunction LED lights up in one of
the corresponding modes.
Turning off the device also occurs automatically immediately
after the cessation of water supply (after the cessation of water
flow in the device). When the device is turned off, the multi-
function LED goes out.
Fig. 18. Water supply using the T-bend with a ball valve.
Fig. 19. Shut-off valve on the pure wa-
ter tap

19
Water flow setting.
BASIC WATER FLOW ADJUSTMENT
Basic adjustment of the water flow through the EMERALD HOME 60 device is carried out by
regulating:
u Cold water shut-off valve on the common tap (use above the sink) - see Fig. 19;
u Shut-off valve on the pure water tap (use under the sink) - see Fig. 19;
Important! For high-quality water purification and electric treatment, set the water flow through
the device in the range of 1 liter/min (60 liters/hour). Do not set the water flow too low (less than 50-
60 liters/hour), as in this case the water flow sensor located in the device will not work and the device
will not turn on.
During operation of the device, the water flow rate may gradually decrease. To restore normal
flow rate, it is necessary to flush the system (see the INSTALLATION MAINTENANCE section).
If you are unable to set a sufficient level of water flow - see the TROUBLESHOOTING GUIDE
Section, Tab. 1.
System Operation Indication.
The multifunctional LED
The first indicator of the proper functioning of the
EMERALD device is the multifunctional LED integrated into
the installation casing. The multifunctional indicator allows
you to evaluate:
u Device resource, after which it is necessary to flush the
system;
u Device flushing process, allowing the user to verify that
all stages of the FLUSHING mode are correctly completed;
u Correct connection of hydraulic and electrical joints.
Electronic ammeter / voltmeter
This measuring device allows the user to see how efficiently
the process of electrical water treatment in the device takes
place. The voltmeter shows the voltage in volts (hereinafter
"V") that is applied to the electrochemical modules. The
ammeter shows the current strength in amperes (hereinafter
"A"), which passes in the electrochemical modules during
water treatment.
Voltmeter readings in OPERATION mode are always
around 24V.
The ammeter readings in the OPERATION mode take on
different values due to:
1) Different total mineralization (TDS) of the source water. The higher the TDS of the source water,
the higher the passing current will be during its electrical treatment (and vice versa).
2) Different degrees of contamination of the electrochemical module and the device as a whole.
The greater the degree of contamination, the weaker the passing current will be and, accordingly,
the efficiency of water purification and activation.
Based on the readings of the current strength (A), the user can estimate:
- The efficiency of the device. The higher the current strength in the OPERATION mode, the more
effective the processes of water purification and activation are (including the process of reducing the
ORP of water).
- The device’s contamination degree; The device must be flushed from accumulated contamina-
tions if the current strength in the OPERATION mode has significantly decreased relative to the ini-
tial values;
Fig. 20. Electronic ammeter / voltmeter
Other manuals for HOME 60
2
Table of contents
Other Emerald Water Filtration System manuals
Popular Water Filtration System manuals by other brands

Bluewater
Bluewater Pro 400B-HR user manual

Pureit
Pureit Ultima RO + UV instruction manual

System air
System air Fantech HERO HS300 Installation and operation manual

Pure Water
Pure Water AquaClean MD-4 owner's manual

Water Care
Water Care TotalCare Series Installation instructions & owner's manual

Puretec
Puretec FP Series user guide

AQUA EL
AQUA EL ULTRA FILTER user manual

Eco Pure
Eco Pure EPWPFF Installation and operation manual

Ro-Man
Ro-Man 3 Stage Standard Instructions for use

Puretec
Puretec ES2 Series user guide

Water Care
Water Care Ion ProSeries Installation instructions & owner's manual

Aqua Medic
Aqua Medic Systemfilter 2000 Operation manual