ELECTRICAL ADJUSTMENTS
2-3: CUT OFF
1. Receive the color bar petter”.
2. Using the remote control. set brightness and
contrast to
minimum
position.
3. Connect the oscilloscope to
,TPO24.
4. Adjust the screen control until voltage is 150VOC.
(Refer to Fig. 2-6)
--
ON”
jiO”
Fig. 2-f
2-4: FOCUS
1. Receive the broadcasting signal.
2. Adiust the locus control until picture is distinct
2-5: VERTICAL SIZE
1. Receive the crosshatch petter” from the color
bar generator.
2. Adjust the bright and contrast controls until
the
crosshatch patter” is distinct.
3. Adjust VA401 until the center of crosshatch
is square.
4. Receive broadcasting signal, the” confirm
picture is
normal.
2-6: VERTICAL POSITION
1,
Receive the color bar patter”.
2. Using the remote control. set brightness and
Contrast Lo maximum position.
3. Adjust the value of A429 and
R430
until horizontal
line of the color bar comes to approximate center
of the CRT.
NOTE
Lessen the value of R430......Picture will move about
5mm
UP.
Lessen the value of R429.....Picture will move about
5mm
DOWN.
R429 and R430 are fixed resistors. Use a variable
resistor to determine the optimal value and insert
that value resistor.
2-7:
HORIZONTAL
POSITION
Receive the color bar patter”.
Using
the remote control. set brightness and
contrast to maximum position.
Adjust the value of
R444
and
C460
until the color width
of both
screen
edges are equal.
Receive
the broadcasting signal, the” confirm
picture
is
normal.
NOTE
Lessen the value of R444......Picture will move right.
Lessen the value of
C460
,...,.Picture
will move left.
R444
and
C460
are fixed components. Use a variable
resistor or capacitor to determine the optimal value
and insert that value component.
3.
PURITY
AND
CONVERGENCE
ADJUSTMENT
NOTE
1. Turn the unit on and let it warm up for at
least
30 minutes before performing the
followiiig
adjustments.
2. Place the CRT surface facing east or west to
reduce the terrestrial magnetism.
3. Turn ON the unit and demagnetize with
a
degauss Coil,
3-1: STATIC CONVERGENCE (ROUGH
ADJUSTMENT
1. Tighten the screw for the magnet. Refer to the
adjusted
CRT
for the position.
(Refer
to
Fig. 3-1)
If the deflection yoke and magnet are in one
body, untighten the screw for
the
body.
2. Receive the green
raster
patter” from
color
bar generator.
3.
Slide the deflection yoke until it touches
the
funnel side
of
the
CRT.
4. Adjust center of screen to green. with red
and blue a” the sides, using the pair
of
purity magnets.
5. Switch the color bar generator from the
green
raster patter” to, the crosshatch
pattern.
6. Combine red
and
blue of the 3
color
crosshatch
Patter”
on
the
center
of the screen by adjusting
the pair of
4
pole magnets.
7. Combine red/blue (magenta) and green by
adjusting the pair of 6 pole magnets.
8. Adjust the crosshatch petter” to change to
white by repeating steps 6 and 7.
3-2:
PURITY
NOTE
Adjust after; performing adjustments in section 3-1
Receive
the green
raster petter” from color bar
generator.
Adjust the pair of purity magnets to center
the
color on the screen.
Adjust the pair of purity magnets so the color
at ends are equally wide.
Move the deflection yoke backward (to
neck
side) slowly, and Stop it at the position
when
the whole screen is green.