manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Emulex
  6. •
  7. Switch
  8. •
  9. Emulex InSpeed 350 User manual

Emulex InSpeed 350 User manual

Enabling New Levels of RAS
& Performance In Back–end
Storage Designs
Improves reliability 15% with a
field–proven solution
Improves availability 20% by reducing
field service time
Lowers in–field service costs 15% with
advanced diagnostics and statistics tools
Increases overall storage system performance
up to 3x while scaling
Automatic trunking improves overall storage system
performance up to 5x while scaling
Reduces time to market 6 to 18 months
Reduces product cost/MB 20% by increasing the viable
number of drives per controller
Model 350
MAJOR FEATURES InSpeed™
Embedded Storage Switch
www.emulex.com
Switch From Shared
The InSpeed™ Embedded Storage Switch Model 350 is
the only storage switch specifically designed for embedded
root switch storage system applications. Unlike in–house
development efforts that use port bypass circuitry, InSpeed
Embedded Storage Switches are designed as a drop–in
solution to deliver 6 to 18 month time to market advantage for
storage system suppliers who want to improve the Reliability,
Availability and Serviceability (RAS) and performance of their
systems. And unlike traditional complex fabric switches
designed for front–end SAN applications that are too big, too
expensive and consume too much power, InSpeed Embedded
Storage Switches are specifically designed to meet the
compatibility and cost–effectiveness that back–end root
switching applications require.
Despite the numerous advances made in storage system
drives and controllers, the back–end connectivity designed
into many of today’s storage systems is still shared loop
technology. While the severe limitations associated with
shared connectivity are broadly acknowledged, the expense
and complexity of implementing high performance switching
technology into the back–end storage arrays was prohibitive
and physically impossible. Emulex’s InSpeed technology has
changed all that.
InSpeed Model 350 Available to OEMs only
Shared Back–end Storage Architecture:
Unexpected Failures, Difficult Servicing,
Data Availability at Risk
As drive density and rotational speeds increase
to accommodate the exponential growth of
end–user storage capacity requirements, the
risks and difficulties associated with existing
storage system RAS levels also increase.
Additionally, performance bottlenecks during
system scaling due to shared loop connectivity
in the back end introduce new points of system
latency. And the lack of management, statistics
and diagnostics capabilities in shared bus
architectures renders the fundamental process
of predicting, troubleshooting and identifying
drive problems an inefficient and costly
undertaking that often entails bringing entire
arrays offline or requires onsite servicing.
How InSpeed Helps
With the introduction of Emulex’s InSpeed
technology, most leading storage OEMs are now
eliminating the latency and inherent reliability
problems associated with shared connectivity.
As a drop–in solution InSpeed enables a
cost–effective and easy conversion to a 2Gb/s
switched back–end architecture that improves
system RAS characteristics, facilitates much–
needed diagnostics capabilities and enables
linear performance growth as the system
scales. InSpeed decreases OEM’s in–field
service costs and the MTTR of their solutions,
while insuring the integrity of their customers’
data is maintained throughout the life of the
storage solution.
InSpeed: A Unique & Disruptive Technology
The underlying core technology behind Emulex’s
line of Embedded Storage Switch products is
called ‘InSpeed’. Designed for performance,
simplicity and compatibility, InSpeed technology
is an advanced switching architecture coupling
a non–blocking Crossbar switch with unique
port logic and embedded SERDES resulting
in a single, highly–integrated switch–on–a–
chip (SOC), capable of multiple concurrent
conversations between Fibre Channel device
ports. Praised by renowned storage industry
analysts and solutions providers, and tested
or deployed by 9 of the 10 largest storage
companies, Emulex’s award–winning InSpeed
technology makes it possible to truly address
embedded storage system requirements for the
very first time.
Improved Reliability
InSpeed Embedded Storage Switches improve
storage system reliability 15% by delivering
an off–the–shelf, field–proven back–end
switching solution that integrates functionality
required by numerous custom–configured
discrete components. When implemented in a
redundant Root Switch configuration, InSpeed
Embedded Storage Switches deliver failure–
independent A & B data paths directly to disk
drive drawers.
 


    


















Higher Availability
InSpeed Embedded Storage Switches
improve system availability 20% by delivering
a very rich set of features designed to keep
storage systems active. These capabilities
are invaluable right from system setup by
performing intelligent pretest of drive drawers
and devices before they are inserted into the
system to eliminate situations where newly
added devices can disrupt a stable system.
And their intelligent health and performance
monitoring is continually collecting vital
statistics to predict failures and take automatic
corrective action to remove problem devices
from the system before they affect overall
system health; error types that affect as much
as 50% of known device failures.
Maximum storage system stability is achieved
with InSpeed’s unique Stealth Intelligent
Change Manager that gives unprecedented
control over embedded network interruptions
caused by health or configuration changes
sent by initiator and target devices. OEMs
can now pre–configure ports at the factory
to appropriately protect them from system
interruptions in their most effective manner.
And, InSpeed’s One-Step Zoning can be evoked
for flexible, dynamic hardware–protected
isolation between groups of ports within the
storage system; an important capability for
applications that require an additional level of
isolation from each other, whether temporarily
or permanently.






The InSpeed Embedded Storage Switch Model 350 is a 1U, half–
rack form factor 12–port non–blocking switch that is ideal for:
Embedded Root Switch In
Disk Storage Systems
Root Switch implementations place switched connectivity be-
tween the storage controller (or NAS head) and drive shelves
within a disk array for enhanced RAS capabilities and up to
3x performance while scaling improvements.












Fully Switched Infrastructure of
Root Switches & SOC–based SBODs
Fully Switched Infrastructures implement a Root Switch in
conjunction with Emulex InSpeed SOCs in SBODs to obtain
maximum RAS and up to 3x performance while scaling im-
provements, and up to 5x with the use of Automatic Trunking.
Improved Serviceability
One of the greatest problems with legacy
loop–based architectures is the ability to quickly
isolate and diagnose problems. This situation
is now eliminated with InSpeed’s built–in
advanced diagnostics and statistics tools.
Problems can now be identified more quickly
and while storage systems are still active to
end users, minimizing system downtime and
lowering field service costs. Furthermore,
InSpeed Embedded Storage Switches deliver
hot–pluggable interface ports that make
removing and replacing drive shelves a simple
effort, as opposed to having to go through
the significant rewiring efforts loop–based
architectures require. Overall, InSpeed–based
storage switches can reduce the total cost
to service storage in the field by as much as
15%, and allow less sophisticated personnel to
perform system diagnosis for faster repair.
Higher System Performance While Scaling
Another primary benefit to storage system
switched back ends is the ability to scale
the number of disk drive spindles behind an
individual storage controller and not encounter
performance degradation. InSpeed Embedded
Storage Switches deliver up to three times the
performance of shared loop architectures as
the storage system scales to higher numbers of
drives. The number of IOPs per MB of storage
can now stay constant, regardless of drive and
capacity scale. Based on a wire speed non–
blocking Crossbar switch core that dynamically
handles multiple simultaneous conversations
at 2 or 1Gb/s performance across all ports, the
switch has a total bandwidth of 48Gb/s. Because
InSpeed delivers multiple direct port–to–port
connections, congestion typically found in shared
loop architectures is eliminated and performance
is made consistent especially as storage systems
scale to additional drives and capacities, and
when storage systems are running advanced
processes like remote mirroring, remote
replication, remote backup or rebuilding activities.
InSpeed Embedded Storage Switches are
packed with standard advanced performance
while scaling enabling features. Fairness and
Prioritization ensure devices communicating
with each other have guaranteed access
to all devices in the system, or explicitly
gives prioritized access over other devices.
And Automatic Trunking fully multiplies
load–balanced bandwidth between InSpeed
Embedded Storage Switches and/or InSpeed
SOCs in fully switched infrastructures and
provides dynamic path failover protection. Up
to 5x performance while scaling improvements
over shared loop infrastructures are possible.
Faster Time to Market
InSpeed Embedded Storage Switches
deliver a 6 to 18 month time to market
improvement over proprietary in–house
developed architectures using port bypass
circuits because InSpeed is a drop–in solution
that has been tested and field deployed by
numerous leading storage system providers.
Testing and validation has been performed
in numerous configurations using InSpeed
storage switches to ensure they are fully
reliable and market ready.








          












 
Reduced Product Costs
Most importantly, InSpeed Embedded Storage
Switches reduce the total cost per MB as
much as 20% of the storage offering to end
users by reducing the number of storage
controllers required to maintain equal or
greater performance as capacity is added to
each controller path. Total cost of ownership
is further reduced because storage system
management is simplified with the advanced
RAS and performance monitoring capabilities
InSpeed provides.
Switch From Shared
Now you can see why Emulex’s InSpeed
Embedded Storage Switches have become
the standard used by most leading storage
system providers within their storage systems.
The InSpeed Embedded Storage Switch
Model 350 exclusively delivers improved
RAS capabilities and greater performance
while scaling over legacy shared loop–based
architectures by providing the dynamic switching
capability required in today’s storage system
environments.









          














 
STANDARDS
Fibre Channel Protocols:
FC-AL, FC-AL2, FC-PH, FC-PH2, FC-PH3, FC-PI,
FC-PLDA, FCP
Interoperability:
connects to any FC_AL compliant device and any
vendors fabric via FL_Port
ARCHITECTURE
Fibre Channel Ports:
12
Physical Interface:
hot–pluggable industry–standard optical
SFP transceivers at all ports
Scalability:
up to 8 switches and 126 devices
1Trunking:
automatic trunking fully multiplies
inter–switch bandwidth with failover pathing
and device prioritization
Zoning:
one–step zoning is port– or ALPA–based
overlapping and port–based non–overlapping
Stability:
Stealth Intelligent Change Manager
automatically eliminates state and
configuration change notification disruptions—
zone and port–based management
Integration:
Emulex InSpeed SOC 320 with integrated SERDES
Redundancy:
resident backup firmware copy
PERFORMANCE
Port Speed:
2.125 or 1.0625 Gb/s bi–directional
(400MBps per port, full duplex)
Switch Latency:
less than 1µSec with no contention, cut–through
routing at 2Gb/s
Performance:
full wire–speed switching
Aggregate Bandwidth: 48Gb/s
Switch Core:
non–blocking Crossbar switch core dynamically
delivers multiple concurrent port–port connections
1Fairness & Prioritization:
ensures all devices have guaranteed access to all
other devices, or explicitly have prioritized access
PHYSICAL ATTRIBUTES
Dimensions:
8.5”w x 1.57”h x 16”d
(21.6cm x 4cm x 40.6cm)
half–rack width, 1U height
Weight:
7.0 lbs (3.2 kg)
Mounting:
rack mount or tabletop
MANAGEMENT
Standard Management Software:
Intuitive Integrated Management Web Server
with Smart Settings
Access:
TELNET, http Web Server, SNMP MIB
Physical Interface:
10BaseT Ethernet (RJ-45), RS-232 serial port
DIAGNOSTICS
Continuous Diagnostic Operations:
power on self test, port test before insertion, traf-
fic & utilization monitoring, continuous link health
monitoring, clock delta monitoring, pinpoint
detection of drive problems, trend monitoring of
device behavior, preventative action before failure,
automatic bypass for rogue and unused ports
Diagnostic Troubleshooting Tools:
CRC error monitoring & counting, ordered set
detectors, counters on every port, ordered set
capture, ordered set transmit
POWER REQUIREMENTS
Nominal:
universal auto–sensing 100-240 VAC, 50/60 Hz,
0.5-0.3 amps
ENVIRONMENTAL CONDITIONS
Operating Temperature: 0° to 40° C
Storage Temperature: -40° to 80° C
Humidity: 5-95% non–condensing
Operating Altitude: up to 15,000 feet
Storage Altitude: up to 35,000 feet
Operating Shock: 5g, 11ms 1/2 sine
Storage Shock: 30g, 11ms 1/2 sine
Operating Sine Vibration: 1g, 5-500 Hz
Operating Random Vibration: ISTA 2A
2AGENCY APPROVALS
United States:
Safety: NRTL, EMC: FCC Class A
Canada:
Safety: NRTL, EMC: ICES-003 Class A
Europe:
Safety: EN60950, EMC: EN55022, EN55024, CE
Japan:
Safety: IEC60950, EMC: VCCI Class A
Australia:
Safety: AS/NZS 3260, EMC: AS/NZS 3548, Class A
International:
Safety: IEC60950, EMC: CISPR22, CISPR24
OPTIONS & ACCESSORIES
The base model 350 ships with a US power cord,
serial cable and Quick Install Card. The Users
Guide is available for download through a weblink
within the embedded web management interface.
Rack mount kit and SFP transceivers are sold
separately.
This document refers to various companies and products by their trade
names. In most, if not all cases, their respective companies claim these
designations as trademarks or registered trademarks. This information
is provided for reference only. Although this information is believed to
be accurate and reliable at the time of publication, Emulex assumes no
responsibility for errors or omissions. Emulex reserves the right to make
changes or corrections without notice.
SPECIFICATIONS
Model 350
InSpeed™
Embedded Storage Switch
www.emulex.com
04-195 1/04
Corporate HQ 3535 Harbor Blvd Costa Mesa CA 92626 714 662.5600 | Wokingham U.K. (44) 118 977 2929 | Paris France (33) 41 91 19 90
1 Patent pending
2 All agency approvals given with optical SFPs only

Other manuals for InSpeed 350

1

Other Emulex Switch manuals

Emulex Model 375 User manual

Emulex

Emulex Model 375 User manual

Emulex Model 375 Instructions for use

Emulex

Emulex Model 375 Instructions for use

Emulex InSpeed 350 User manual

Emulex

Emulex InSpeed 350 User manual

Emulex InSpeed 370 User manual

Emulex

Emulex InSpeed 370 User manual

Emulex InSpeed 355 User manual

Emulex

Emulex InSpeed 355 User manual

Emulex InSpeed 355 User manual

Emulex

Emulex InSpeed 355 User manual

Popular Switch manuals by other brands

Intellinet IES-08FP instructions

Intellinet

Intellinet IES-08FP instructions

Edge-Core AS6701-32X quick start guide

Edge-Core

Edge-Core AS6701-32X quick start guide

NETGEAR GSS108E user manual

NETGEAR

NETGEAR GSS108E user manual

SIMEREC PCS-2 quick start guide

SIMEREC

SIMEREC PCS-2 quick start guide

3Com 4510G Configuration guide

3Com

3Com 4510G Configuration guide

Agilent Technologies Agilent 3499A Quick reference guide

Agilent Technologies

Agilent Technologies Agilent 3499A Quick reference guide

Videosec PSH04GE+4GE user guide

Videosec

Videosec PSH04GE+4GE user guide

Samsung SPU-400 user guide

Samsung

Samsung SPU-400 user guide

steute Ex T 356 Mounting and wiring instructions

steute

steute Ex T 356 Mounting and wiring instructions

ZyXEL Communications ZyXEL P-872H quick start guide

ZyXEL Communications

ZyXEL Communications ZyXEL P-872H quick start guide

ifs NS4750-24S-4T-4X-V2 Quick installation guide

ifs

ifs NS4750-24S-4T-4X-V2 Quick installation guide

IKEA DIRIGERA manual

IKEA

IKEA DIRIGERA manual

Linksys SLM2024 Product data

Linksys

Linksys SLM2024 Product data

Manley Mastering Backbone owner's manual

Manley

Manley Mastering Backbone owner's manual

Juniper EX4500 Series Hardware guide

Juniper

Juniper EX4500 Series Hardware guide

STEINEL PROFESSIONAL HF 180 manual

STEINEL PROFESSIONAL

STEINEL PROFESSIONAL HF 180 manual

Enabling Devices Button Click Switch user guide

Enabling Devices

Enabling Devices Button Click Switch user guide

HEIDENHAIN TNC 415 Technical manual

HEIDENHAIN

HEIDENHAIN TNC 415 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.