Pager Module Installation Page 1AW000924-B
Energate Foundation™ Pager Module Installation
The optional RM41F pager module allows electricity providers to communicate remotely with the
Energate Foundation™ Smart Thermostat and Home Energy Gateway.
You can add a pager module to Foundation models FZ100 or FZ100C.
The pager module ships with a cover that replaces the filler plate in Foundation’s casing after the module
is installed.
Installation
To begin the pager module installation, remove the Foundation from the mounting bracket, even if it is
not mounted on a wall.
1. Use a large flathead screwdriver to lift up the snap-fit tab located on top of the mounting bracket
until you can pull the top of the Foundation away from the bracket. Then completely remove
Foundation from the bracket.
Note: Be careful not to dislodge any wiring that is still connected on the back.
If the screwdriver is too small, the tab and/or thermostat housing can be damaged.
2. Locate the covered USNAP module
slot on the back of the Foundation.
Use a small, flathead screwdriver to
remove the filler plate.
3. Slide the pager module into the slot, ensuring that the tabs that position it are at the bottom,
against the circuit board. Ensure that the module’s pin connector is completely inserted.
4. Snap the supplied cover over the tab
end of the pager module slot. It
should be flush with the side of the
Foundation’s casing.
5. To re-attach the Foundation to the
mounting bracket, position the
Foundation in the bottom of the
bracket using the bottom snap-fit tab.
Gently push the Foundation into the
rest of the bracket until the top tab
snaps into place.
6. Wait for the Foundation to power up.

Pager Module Installation Page 2AW000924-B
7. From the Thermostat main menu, navigate to the Installer Setup menu.
When the pager module is installed and working properly, the Pager option is displayed in the
Installer Setup menu. Use this option to access information about the pager module’s connection to
the network and other troubleshooting information.
Pager Module Signal Status
The thermostat cannot receive messages or DR events until it is provisioned using the CCDR website
provided by the electric utility.
After the pager module is provisioned, the link status indicator at the top right of the Temperature or
Energy home screen displays the status of the Foundation’s wireless uplink signal(s). The following
indicators can be displayed to the right of the signal strength bars:
•F: Thermostat is receiving communications from its server using the pager module.
•D: Thermostat is communicating with its server using both the pager module and a ZigBee
gateway (dual wireless uplinks).
•Z: Thermostat is communicating with its server using a ZigBee gateway.
Pager Link Information
Use the Pager menu’s Link Info option to display information such as connection status, pager radio signal
strength, and hardware/firmware version information. A two-digit confirmation code (CC) is displayed in
the bottom-right corner of the Link Info screen, verifying successful provisioning.
The first Link Info screen displays the current status of the pager module’s connection to the network:
Message
Description
CONNECTION
ACTIVE
Normal condition when working correctly.
Foundation is connected to and successfully communicating with the CCDR
server over the pager radio network.
SEARCHING FOR
NETWORK
The pager module is working but is unable to detect the pager network.
NETWORK LOST
The pager module is working and was previously connected to the pager
network, but is no longer communicating with the network.
PAGER HARDWARE
ERROR
There is a problem with the pager module related to its hardware or
configuration. Please contact technical support.
WAITING FOR
COMMISSION
The pager module is working, has detected the pager network, and is waiting
to be provisioned (commissioned).
WAITING FOR
BEACON
The pager module is connected to the pager network but is waiting for a
beacon signal from the pager network.
The Foundation cannot be provisioned until it receives the beacon signal.
For information on troubleshooting a pager module installation, see the Troubleshooting section in
Installation Guide for Energate Thermostats.
Compliance Information
Product: Flex Pager USNAP Radio Module
Model: RM41F
Responsible Party: Energate Inc., 2379 Holly Lane, Suite
200, Ottawa, Ontario K1V 7P2, Canada. T.: 613-482-7928
This equipment is RoHS compliant.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications not expressly approved by the
party responsible for compliance could void the user's
authority to operate the equipment
This device complies with Industry Canada licence-
exempt RSS standard(s). Operation is subject to the
interference, and (2) this device must accept any
following two conditions: (1) this device may not cause
interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie
Canada applicables aux appareils radio exempts de
licence. L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de
brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le
fonctionnement.
This Class B digital apparatus complies with Canadian
ICES-003.
Cet appareil numérique de la classe B est conforme à la
norme NMB-003 du Canada.
Cet appareil numérique de la classe B est conforme à la
norme FCC 47 CFR Part 15.
Table of contents