SS-EN-00-IDM250
250W Universal In-Line LED Dimmer Module
Operating Voltage 240V ac
Nominal Operating Frequency 50 Hz
Dimming Technique Trailing & leading edge phase control
Compliance BS EN 60669-2-1
Multi-Gang Switch De-Rating Chart - LED Lighting
1 Gang 2 Gang 3 Gang 4 Gang 5 Gang
250W 212W 175W 137W 100W
On/O󰀨 and dimming is achieved with a connected Retractive Switch, or multiple
(parallel) Retractive Switches, please refer to example circuit diagrams on the
other side of this document for details.
A fast click of the Retractive Switch will turn the lamp (or Load) on and o󰀨,
holding the switch will alternately dim the lamp up or down, release the switch
when desired lamp brightness has been achieved.
The minimum/maximum level and dimming mode can be manually adjusted by
following the procedures below.
SETTING THE MINIMUM LEVEL
1. Whilst on, adjust dimmer to your desired minimum brightness.
2. Push the setup button 3 times within 2 seconds.
3. The LEDs will step up and down in brightness once to conrm the setting has
been saved.
SETTING THE MAXIMUM LEVEL
1. Whilst on, adjust dimmer to your desired maximum brightness.
2. Push the setup button 5 times within 3 seconds.
3. The LEDs will step up and down in brightness once to conrm the setting has
been saved.
FACTORY RESET FOR MIN/MAX BRIGHTNESS
Please note this factory reset will reset all the min and max brightness settings.
1. Whilst on, push the rear setup button 7 times within 5 seconds.
2. The LEDs will step up and down in brightness three times to conrm that the
min/max setting has been cleared.
CHANGING THE DIMMING MODE
The default mode of the dimmer is Trailing Edge, but it can be put into Leading
Edge if required. Please ensure that you know the correct mode for your lamp.
1. Whilst on, push the setup button 9 times within 5 seconds.
2. The LEDs will step up and down in brightness twice to conrm the setting
has been changed to Leading Edge mode.
NOTE:
To switch back to Trailing Edge mode, just repeat the process again, the LEDs
will step up and down once to show the dimmer is back in Trailing Edge mode.
SETUP INSTRUCTIONS
Load Symbol Compatible Loads Max Load Min Load
Dimmable LED lighting 250W TE
100W LE 2W
240V Incandescent
& Halogen lamps
250W TE
100W LE 2W
Low voltage lighting with
electronic transformers
250W TE
100W LE 2W
• Easy push button setup
• Trailing/Leading Edge
• No Neutral required
• On, O󰀨 & Dimming funtion
controlled via connected
Retractive Switch(s)
• Soft start feature
• Small form factor, will t into an
achitrave back box
• Silent & icker free
• Self Recovering Thermal Fuse
• Short Circuit & Overload Protection
WARNING - PLEASE READ
RISK OF ELECTRIC SHOCK
●Hazardous voltage and electrical current may be present at the wire leads of this product even when
the device is switched o󰀨.
●Lock out and tag the input circuit before accessing the wiring connections.
●This device must be installed by a qualied and experienced electrician in accordance with applicable
current electrical regulation.
●To comply with all safety standards, the product must be used only for the purpose described in this
instruction and must be installed in accordance with the wiring rules and regulation in the location
where it is installed.
●There are no user serviceable parts inside the product.
Failure to follow these instructions can result in death or serious injury.
EQUIPMENT DAMAGE HAZARD
●Install the device according to instructions in this document.
●Pay attention to the specications and wiring diagrams related to the installation.
●Do not use this product for any other purpose than specied in this instruction.
●The product is suitable for indoor use only.
●Apply IEC60898-1 compliant 250V~ 6A MCB as an overload protective device.
LEGAL DISCLAIMER
The installation of electrical products is inherently dangerous and can lead to serious injury or death.
The products we sell MUST be installed by a qualied and experienced electrician in accordance with
applicable current electrical regulation. Any advice, guidance or other information provided by Enkin on
their website or within any of our publications cannot completely anticipate your situation and common
sense must prevail. Products need to be checked prior to installation and regularly for damage and wear
and tear. Products should be returned and not used if in any doubt of their integrity.
Electrical rated loads and limits of a given product should NEVER be exceeded at any time. The
electricity supply should always be isolated at its source (Distribution Board) before attempting any
installation or maintenance.
No advice or information, whether oral or written, obtained by you from us or through the service, our
employees, consultants and/or retailers shall create any warranty not expressly made herein.
You agree to assume all and any risk resulting from the utilisation of information provided by Enkin. You
also expressly agree not to hold us responsible for any damage, personal injury, death or loss resulting
from your use of our information, service or regulatory compliant products.
Enkin is a trading name of Trade Ivy. Registered in England Number: 10809945. Copyright © 2021
All Rights Reserved. Trade Ivy Limited, Unit 3C Latham Park, St Blazey Road, Par, PL24 2HY.
ENVIRONMENTAL PROTECTION
Waste electrical products should not be disposed of with household waste. Please recycle where
facilities exist. Check with your local authority or retailer for recycling advice.
Scan QR Code for more detailed technical
information on this product
IP20
www.enkin.com
RETRACTIVE
SWITCH
DIMMER SETUP
BUTTON
LIVE
N
L
LOAD SWITCHED LIVE
(LOAD)
1
LC
2
WIRING DIAGRAM
Single Retractive Switch
PARALLEL
RETRACTIVE
SWITCHES
DIMMER SETUP
BUTTON
LIVE
N
L
LOAD SWITCHED LIVE
(LOAD)
1
LC
2
WIRING DIAGRAM
Multiple Retractive Switches

Popular Controllers manuals by other brands

Fujitsu MB86292 Orchid Faq

Fujitsu

Fujitsu MB86292 Orchid Faq

ICP DAS USA I-8431 quick start guide

ICP DAS USA

ICP DAS USA I-8431 quick start guide

Audiovox CDC-10R owner's manual

Audiovox

Audiovox CDC-10R owner's manual

JEON DG Series manual

JEON

JEON DG Series manual

JENCO 6309PDTF Operation manual

JENCO

JENCO 6309PDTF Operation manual

Holley 551-102 Quick start manual

Holley

Holley 551-102 Quick start manual

Assured Automation K4 Series Installation, operation & maintenance manual

Assured Automation

Assured Automation K4 Series Installation, operation & maintenance manual

Arbor Technology ARES-1970-E user manual

Arbor Technology

Arbor Technology ARES-1970-E user manual

Mitsubishi Electric MELSEC iQ-R Series user manual

Mitsubishi Electric

Mitsubishi Electric MELSEC iQ-R Series user manual

Marmitek IRRF7243 operating instructions

Marmitek

Marmitek IRRF7243 operating instructions

cashco DA8 Installation, operation & maintenance manual

cashco

cashco DA8 Installation, operation & maintenance manual

Rotem Platinum PLUS installation manual

Rotem

Rotem Platinum PLUS installation manual

Hoval TopTronic E instructions

Hoval

Hoval TopTronic E instructions

HP 30242 Installation and service manual

HP

HP 30242 Installation and service manual

Aurora Scientific miniPID 200C manual

Aurora Scientific

Aurora Scientific miniPID 200C manual

ZyXEL Communications NXC2500 Handbook

ZyXEL Communications

ZyXEL Communications NXC2500 Handbook

LINK-MI LM-TV09S user manual

LINK-MI

LINK-MI LM-TV09S user manual

Ametek Dunkermotoren BGE 6060 A EC Operation manual

Ametek

Ametek Dunkermotoren BGE 6060 A EC Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.