Envira-North EN560X0010 Guide

1
METRIC & IMPERIAL
DESIGN & ENGINEERING GUIDE
1-866-771-7766 bigair@enviranorth.com
www.EnvIRAnoRTh.CoM/jAzzfAns

2
TABLE OF CONTENTS
JAZZ FAN INTRODUCTION..................................... 1
Moving Air With Style............................................3
Ordering & Installation ..........................................4
Mounting System ...................................................4
Mounting Applications...........................................5
Safety Systems .......................................................6
FAN COMPONENTS DIAGRAM............................... 7
3 m (10’) Jazz Fan Assembly Drawing ....................8
3 m (10’) Jazz Fan Specifications............................9
Minimum Blade Clearance...................................10
Drop Assembly ....................................................11
Drop Pipe............................................................12
Remote Display ...................................................13
Control Assembly ................................................14
Fan Packaging Details..........................................15

3
THE JAZZ FAN - OUR NEWEST ADDITION
From showrooms to restaurants and atriums to office spaces, the
Jazz Fan’s creative touch of ambiance enhances the comforts and
aesthetics of each space. The sleek, ultra-modern design allows for
a magnitude of customizable finishes from vibrant red to brilliant
chrome and every imaginable color in between, enhancing any
sophisticate environment.
MOVING AIR WITH STYLE
Traditional airfoils (or blades) are linear in design and produce
greater noise at a particular frequency. Using varying points on the
leading edge of the blade spreads the noise or acoustic signature
over a greater range of frequencies, virtually eliminating any noise.
As a fan rotates, the tip of a blade spins faster than the fixed point
or ‘centre’ creating pockets of minimal air movement directly
underneath the fan. The Jazz Fan blade design tackles this challenge
with a varying degree angle of attack, never before seen in our
industry. Ranging from 6° (tip) to 14° at its greatest point, the Jazz
Fan diminishes the resistance against each blade maximizing air
movement and minimizing power consumption.
Jazz Fan’s unique blade design doesn’t just look good; it deploys
the same modulated blade technique utilized in advanced stealth
helicopters; making it possible to move more air; quietly and in
style. Jazz Fans move 45,000 CFM with a max noise level of
39dBA. Covering an area of 260m3 (2,800 ft²), the Jazz fan exceeds
the highest of industry standards in all categories of form and
function.

4
ORDERING AND INSTALLATION MADE SIMPLE
Jazz Fans come as a complete package that includes; the Jazz Fan,
Universal Mounting System, Wiring Kit, and Control Panel. Having
everything included in this complete package streamlines ordering,
shipping and installation. From start to finish, Envira-North Systems
provides everything you need – in one simple package.
DISTINCTIVE UNIVERSAL MOUNTING SYSTEM
A complete redesign from top to bottom – no other HVLS Fan
on the market can provide the robust yet sleek design of the Jazz
Fan’s Universal Mounting System. Included in every Jazz Fan,
the distinctive Universal Mounting System permits the Jazz Fan to
be installed on a wide range of ceiling structures that includes; I
Beams, Open Web Steel Joists, Wood Beams (Glu Lam), Purlins and
Wooden Trusses.
The design doesn’t stop there – the entire mounting kit is intended
to act as a housing for your electric wiring – meaning power to the
fan and from the control is invisible to the people below. Better yet,
the Universal Mounting System also allows for the Jazz Fan to be
located on any sloped ceilings from 0-18.5° with a complete 360°
swivel.

5
DIFFERENT MOUNTING APPLICATIONS
GLU LAM MOUNT OWSJ MOUNT
PURLIN MOUNT WOOD TRUSS MOUNT
For a complete review of the mounting system and how it applies to your application, please reference the
Jazz Fan Installation Guide. To obtain a copy, please visit www.enviranorth.com

6
SAFETY SYSTEMS
The Jazz Fans are supplied with superior safety equipment and
harnessing systems to maintain an integral safety status and give
the customer peace of mind. All fan installations include safety
cables, safety flat washers, safety lock washers, safety bolts and
thermal protection on the motor to prevent overheating. If fans are
installed between racks in a storage facility, signs should be posted
identifying locations. The variable frequency drive also comes
equipped with a current limit, motor overload sensor, minimum and
maximum speed control.
[3 mm] 1/8” SS Cable [2.13 m] 7’ Length
(2)[6 mm] 1/4” SS Thimble
(4)[3 mm] 1/4” SS Thimble

7
FAN COMPONENTS DIAGRAM
[3 mm] 1/8” SS Cable
[2.13 m] 7’ Length
(2)[6 mm] 1/4” SS Thimble
(4)[3 mm] 1/4” SS Thimble
[152.4 mm] 6” Standard Jazz Drop Pipe
Optional Custom Lengths Available
See Mounting Applications
Hub Cover Assembly
(LED Light Optional)
Fan Drive Assembly
(Includes Hub)
(5) Blades (Not Shown)
(20) 1/4” - 20 x 0.75 LG
Hex Cap Screws
(5) 8-32 x 1.375” LG Pan Head Screws
Note: All bolts are “class 8.8”
FT = Fully Threaded
(#) = Quanitity Supplied

8
3 M (10’) JAZZ FAN
0.7m
27.1in
3.1m
120.3in
Checked Date:
July-17-15 2:50:10 PM
.
Last Saved Date:
1
2
3
4
5
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF ENVIRA-NORTH SYSTEMS LTD. ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF ENVIRA-NORTH SYSTEMS LTD IS
PROHIBITED. SHOULD THERE BE ANY DISCREPANCIES WITH
THIS CONSTRUCTION DRAWING, ENVIRA-NORTH SYSTEMS LTD
SHOULD BE CONTACTED IMMEDIATELY FOR RESPONSE.
PROPRIETARY AND CONFIDENTIAL
REVISIONS:
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
WEIGHT IS IN POUNDS
TOLERANCES:
FRACTIONAL
1/16
ANGULAR: MACH
0.1
BEND
0.5
TWO PLACE DECIMAL
0.060(1.5mm)
THREE PLACE DECIMAL
0.030(0.76mm)
MATERIAL
VENDORS NUMBER:
AS SPECIFIED
AS SPECIFIED
DRAWN
Checked By:
COMMENTS:
Drawing Date:
Last Revised Date:
TITLE:
SIZE
A
DWG. NO.
REV
WEIGHT: 83.92
SCALE: 1:25
BM
28/05/2015
SHEET 1 OF 1
EN560X0010
DO NOT SCALE DRAWING
FINISH
Envira-North Systems Ltd.
JAZZ FAN - COMPLETE
ASSEMBLY
Q:\01_Envira-North\SolidWorks (DWG) EN\EN560X0010
Note:
Contractor is responsible for
verifying all site conditions to include field
dimensions where applicable. It the contractor elects to
make any changes without notifying Envira-North Systems
Ltd. the contractor is responsible for the same. All
drawings are to be used as general architectural intent only
unless otherwise stamped. See Engineering drawings for
structural design information. Contractor to ensure that all
building departments and
authorities are informed in regard to the work and that all
permits are attained before commencing the work.
0

9
3 M (10’) JAZZ FAN
General
Model Number.............................................................. EN560X0010
Diameter ....................................................................... 3 m (10’)
Number of Blades.......................................................... 5
Motor Power ................................................................. 0.5 hp
Noise Level ................................................................... 53 dBA
Overall Weight (no mount)............................................ 90 lbs (41 kgs)
Packaged Fan Weight ................................................... 135 lbs (61 kgs)
Performance (at max speed)
Airflow .......................................................................... 45,000 CFM
Maximum Speed ........................................................... 120 RPM
Power Usage ................................................................. 450 W
Maximum Effective Diameter ........................................ 18.2 m (60’)
Construction
Frame............................................................................ Black Zinc Coated Steel
Hub .............................................................................. Black Zinc Coated Steel
Blades ........................................................................... Fibre Filled Polypropolene
Safety Components
Safety Cables................................................................. 1/8” Stainless Steel Cable
Mounting Hardware
Standard Mount............................................................. Universal Mounting System
Mounting*
Glu Lam Mount............................................................. Included
Open Web Steel Joist..................................................... Included
Wood Beam Mount....................................................... Included
Purlin “Z” Mount........................................................... Included
Gearmotor
Type.............................................................................. Helical Inline
HP................................................................................. 0.5 hp (0.37 kW)
Ratio.............................................................................. 15.77:1
Volts.............................................................................. 230 V
Amps Consumed ........................................................... 1.9 A
Insulation Class ............................................................. F
Torque........................................................................... 289 lb-in
VFD Control
Enclosure....................................................................... Nema 4X
Standard Power ............................................................. 110 V
50 / 60 Hz Operation
Jazz Wall Control
Operation...................................................................... Keypad
Lockable........................................................................ Yes
Light Control ................................................................. Dimmable ON / OFF
Wiring........................................................................... Supplied
Diagnositc Capability .................................................... Full

10
FAN BLADE CLEARANCE JAZZ FAN BLADE CLEARANCES
12in
(304.8mm)
120in
3048mm
12in
304.8mm
8in
203mm
27in
686mm
27in
675mm
29in
739mm
CLEARANCES:
Open ceiling, center of fan to roof deck for ideal
•
operating performance without comprising
overall fan performance
Finished ceiling, min 48" [1220] center of fan to
•
finished ceiling for ideal operating performance
without comprising overall fan performance
Min 12" [304.8 from fan blade's leading edge to
•
obstruction above or below fan.
Min 8" [203] from side of fan to any obstruction
•
Min floor to fan leading edge height 120" [3048]
•
NOTE: All dimensions are
minimum requirements
Dimensions are in inches,
metric dimensions [mm].
SLOPED ROOF
FLAT ROOF
FAN FRAME DETAIL
HEAT SOURCE CLEARANCES:
As per heating installation minimum clearances
•
AIR DUCT CLEARANCES:
Excessive air movement on the fan will create
•
improper balancing and excessive stresses to
the moving components
ENG APPR. Date:
ENG APPR.
Checked Date:
September-08-15 11:42:05 AM
Last Saved Date:
1
2
3
4
5
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF ENVIRA-NORTH SYSTEMS LTD. ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF ENVIRA-NORTH SYSTEMS LTD IS
PROHIBITED. SHOULD THERE BE ANY DISCREPANCIES WITH
THIS CONSTRUCTION DRAWING, ENVIRA-NORTH SYSTEMS LTD
SHOULD BE CONTACTED IMMEDIATELY FOR RESPONSE.
PROPRIETARY AND CONFIDENTIAL
REVISIONS:
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
1/16
ANGULAR: MACH
0.1
BEND
0.5
TWO PLACE DECIMAL
0.060
THREE PLACE DECIMAL
0.030
MATERIAL
VENDORS NUMBER:
DRAWN
Checked By:
MFG APPR.
Q.A.
COMMENTS:
Drawing Date:
Last Revised Date:
TITLE:
SIZE
A
DWG. NO.
REV
WEIGHT:
SCALE: N.T.S.
B. MARKS
08/09/2015
.
.
SHEET 1 OF 1
DO NOT SCALE DRAWING
FINISH
Envira-North Systems Ltd.
Q:\01_Envira-North\SolidWorks (DWG) EN\JAZZ-MOUNTING-CONTRAINTS\JAZZ-MINIMUM CLEARANCES
Note:
Contractor is responsible for
verifying all site conditions to include field
dimensions where applicable. It the contractor elects to
make any changes without notifying Envira-North Systems
Ltd. the contractor is responsible for the same. All
drawings are to be used as general architectural intent only
unless otherwise stamped. See Engineering drawings for
structural design information. Contractor to ensure that all
building departments and
authorities are informed in regard to the work and that all
permits are attained before commencing the work.
JAZZ FAN
MIMIMUM CLEARANCES
MINIMUM DIMENSIONS
FOR CLEARANCE

11
JAZZ MOUNT
9
A A
SECTION A-A
2
1
3
4
5
8
7
6
ITEM NO.
PART NUMBER
DESCRIPTION
QTY.
1
EN562X2501
JAZZ LOWER PIVOT PLATE
1
2
EN562X2502
JAZZ DROP PIVOT PIN
1
3
EN562X2500
JAZZ UPPER PIVOT PLATE
1
4
EN562X2506
1/4 X 1-1/4 LG.-SQUARE KEY
1
5
EN823X6026
1/4-20 X 0.625 SOCKET HEAD CAP SCREW
3
6
EN562X2503
JAZZ DROP COUPLER
1
7
EN562X2505-6IN
JAZZ DROP PIPE 1-1/2"NPT X 6
1
8
EN562X2504
JAZZ DROP FLANGE
1
9
EN823X6027
5/16 X 3/8 SET SCREW CUP POINT
3
ENG APPR. Date:
ENG APPR.
Checked Date:
September-08-15 10:15:44 AM
1-Change SN part numbers to EN part numbers
Last Saved Date:
1
2
3
4
5
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF ENVIRA-NORTH SYSTEMS LTD. ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF ENVIRA-NORTH SYSTEMS LTD IS
PROHIBITED. SHOULD THERE BE ANY DISCREPANCIES WITH
THIS CONSTRUCTION DRAWING, ENVIRA-NORTH SYSTEMS LTD
SHOULD BE CONTACTED IMMEDIATELY FOR RESPONSE.
PROPRIETARY AND CONFIDENTIAL
REVISIONS:
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
1/16
ANGULAR: MACH
0.1
BEND
0.5
TWO PLACE DECIMAL
0.060
THREE PLACE DECIMAL
0.030
MATERIAL
VENDORS NUMBER:
AS SPECIFIED
AS SPECIFIED
DRAWN
Checked By:
MFG APPR.
Q.A.
COMMENTS:
Drawing Date:
Last Revised Date:
TITLE:
SIZE
A
DWG. NO.
REV
WEIGHT: 10.71
SCALE: 1:3
BM
15/06/2015
17/06/2015
PA
SHEET 1 OF 2
EN561X2500
DO NOT SCALE DRAWING
FINISH
Envira-North Systems Ltd.
JAZZ DROP
Q:\01_Envira-North\SolidWorks (DWG) EN\EN561X2500
Note:
Contractor is responsible for
verifying all site conditions to include field
dimensions where applicable. It the contractor elects to
make any changes without notifying Envira-North Systems
Ltd. the contractor is responsible for the same. All
drawings are to be used as general architectural intent only
unless otherwise stamped. See Engineering drawings for
structural design information. Contractor to ensure that all
building departments and
authorities are informed in regard to the work and that all
permits are attained before commencing the work.
1
JAZZ FAN DROP ASSEMBLY

12
JAZZ FAN DROP PIPE
6.00 (PROVIDED)
1-1/2 NPT BOTH ENDS
NOTE: VARIOUS DROP LENGTHS AVAILABLE UPON REQUEST
DO NOT SCALE DRAWING
EN562X2505
SHEET 1 OF 1
11/06/2015
BM
UNLESS OTHERWISE SPECIFIED:
SCALE:
WEIGHT: 1.34
REV
DWG. NO.
A
SIZE
TITLE:
Last Saved Date:
Drawing Date:
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
Checked Date:
DRAWN
Sun-North Systems Ltd.
AS SPECIFIED
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
1/16
ANGULAR: MACH
0.1 BEND
0.5
TWO PLACE DECIMAL
0.060
THREE PLACE DECIMAL
0.030
REVISIONS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF SUN-NORTH SYSTEMS LTD. ANY REPRODUCTION
IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF
SUN-NORTH SYSTEMS LTD IS PROHIBITED. SHOULD THERE BE ANY
DISCREPANCIES WITH THIS CONSTRUCTION DRAWING, SUN-
NORTH SYSTEMS LTD SHOULD BE CONTACTED IMMEDIATELY
FOR RESPONCE.
5
4
3
2
1
Last Revision Date:
ENG APPR. Date:
September-04-15 12:42:40 PM
Checked By:
Q:\02_Sun-North\SolidWorks (DWG) SN\SN710X2505
BLACK GALVANIZED
JAZZ DROP PIPE 1-1/2"NPT X 6
1:2
VENDOR: FASTENAL P/N-66476
0

13
JAZZ VFD DRAWINGJAZZ FAN REMOTE DISPLAY
247.7mm
9.8in
184.2mm
7.3in
ISOMETRIC VIEW
SCALE: 1:4
25.4mm
1.0in
73mm
2.9in
Checked Date:
August-28-15 3:56:00 PM
1- New dimmer,switch and keypad inside another
enclosure
Last Saved Date:
1
2
3
4
5
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF ENVIRA-NORTH SYSTEMS LTD. ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF ENVIRA-NORTH SYSTEMS LTD IS
PROHIBITED. SHOULD THERE BE ANY DISCREPANCIES WITH
THIS CONSTRUCTION DRAWING, ENVIRA-NORTH SYSTEMS LTD
SHOULD BE CONTACTED IMMEDIATELY FOR RESPONSE.
PROPRIETARY AND CONFIDENTIAL
REVISIONS:
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
WEIGHT IS IN POUNDS
TOLERANCES:
FRACTIONAL
1/16
ANGULAR: MACH
0.1
BEND
0.5
TWO PLACE DECIMAL
0.060(1.5mm)
THREE PLACE DECIMAL
0.030(0.76mm)
MATERIAL
VENDORS NUMBER:
AS SPECIFIED
DRAWN
Checked By:
COMMENTS:
Drawing Date:
Last Revised Date:
TITLE:
SIZE
A
DWG. NO.
REV
WEIGHT: 1.56
SCALE: 1:2
B.MARKS
29/07/2015
SHEET 1 OF 1
EN561X3500
DO NOT SCALE DRAWING
FINISH
Envira-North Systems Ltd.
JAZZ REMOTE
Q:\01_Envira-North\SolidWorks (DWG) EN\EN561X3500
Note:
Contractor is responsible for
verifying all site conditions to include field
dimensions where applicable. It the contractor elects to
make any changes without notifying Envira-North Systems
Ltd. the contractor is responsible for the same. All
drawings are to be used as general architectural intent only
unless otherwise stamped. See Engineering drawings for
structural design information. Contractor to ensure that all
building departments and
authorities are informed in regard to the work and that all
permits are attained before commencing the work.
28/08/2015
1

14
JAZZ FAN CONTROL ASSEMBLY
232mm
9.1in
42.5mm
1.7in
426.9mm
16.8in
42.4mm
1.7in
76.2mm
3.0in
161mm
6.3in
176mm
6.9in
55mm
2.2in
82.3mm
3.2in
57.9mm
2.3in
27.4mm
1.1in
76.2mm
3.0in
DO NOT SCALE DRAWING
EN561X2070
SHEET 2 OF 2
30/07/2015
B.MARKS
UNLESS OTHERWISE SPECIFIED:
SCALE: 1:2
WEIGHT: 8.5
REV
DWG. NO.
A
SIZE
TITLE:
Last Saved Date:
Drawing Date:
COMMENTS:
Q.A.
MFG APPR.
ENG APPR.
Checked Date:
DRAWN:
Envira-North Systems Ltd.
AS SPECIFIED
FINISH
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
1/16
ANGULAR:
MACH
0.1
BEND
0.5
TWO PLACE DECIMAL
0.060
THREE PLACE DECIMAL
0.030
REVISIONS:
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE
PROPERTY OF ENVIRA-NORTH SYSTEMS LTD. ANY
REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE
WRITTEN PERMISSION OF ENVIRA-NORTH SYSTEMS LTD IS
PROHIBITED. SHOULD THERE BE ANY DISCREPANCIES WITH THIS
CONSTRUCTION DRAWING, ENVIRA-NORTH SYSTEMS LTD
SHOULD BE CONTACTED IMMEDIATELY FOR RESPONSE.
5
4
3
2
1
Last Revision Date:
ENG APPR. Date:
Checked By:
Q:\01_Envira-North\SolidWorks (DWG) EN\
Tolerance:
+/- 0.005"
JAZZ CONTOL
ASSEMBLY
July-30-15 1:12:03 PM
0

15
JAZZ FAN PACKAGING DETAILS
EXTERIOR
INSIDE OUTSIDE
[33 cm]
13”
[63.5 cm]
25”
[157.5 cm] 62”

16
Tel: 1-519-527-2198 Fax: 1-519-527-2560
Toll Free: 1-886-771-7766
92 Railway St. P.O Box 668
Seaforth, Ontario
Canada N0K 1W0
www.EnvIRAnoRTh.CoM/jAzzfAns
Table of contents
Popular Fan manuals by other brands

Kichler Lighting
Kichler Lighting Canfield Patio 310192 instruction manual

EDM Product
EDM Product 33973 instruction manual

Lincat
Lincat SV1212 User and installation instructions

Mitsubishi Electric
Mitsubishi Electric Lossnay series Technical manual

Salda
Salda RIRS 400HE/HW EKO 3.0 Technical manual

Holmes
Holmes HAOF1233 owner's guide