Envirovent ECO2 Air Twin User manual



You are about to install a product that is designed to outlast the life-cycle of the building.
Once installed the unit will operate continuously for 5 years and beyond without a major
service. Please therefore ensure that this product is treated with care and installed properly
i.e. for the life of the building. If the unit is mishandled you might break it! This invalidates
the warranty.
And remember, if you have any problems please call our dedicated Technical Team. We
are always pleased to help and in an emergency will come out to site quickly, completely
free of charge.
HOTLINE: 0845 27 27 810
Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter
products specication and appearance without notice.

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
0845 27 27 810
ECO2Air Twin & ECO2Loftight Twin
PRE-INSTALLATION CHECKLIST
Check that the loft has adequate cross ow
ventilation.
Check for any ued appliance which may draw
air from the loft, report to the client.
Check for any holes in the ceilings which may
allow leakage of air to the loft and repair as
appropriate.
Check that the water storage tank is covered.
1
2
3
4
Check that any ue which passes through the
loft is not damaged, seek advice if the ue is in
a poor state of repair.
IMPORTANT
Smoke Detectors
It is important that any open side of the plastic diuser is
not positioned within 1m of a smoke detector. If the diuser
cannot be repositioned, up to two sides of the diuser may
be closed o using the plastic blanking plate supplied so
that the open sides face a minimum 1.5m unobstructed
path away from the detector.
SAFETY AND RECOMMENDATIONS
All wiring must comply with Building Regulations
and the current I.E.E. Wiring Regulations (BS7671)
or the equivalent standards for your country. The
nal installation should be examined and tested by
a qualied electrician. This appliance is not intended
for use by any person with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety. Children should
be supervised to ensure that they do not play with
the appliance. If the supply cord is damaged, it must
be replaced by the manufacturer, its service agent or
similarly qualied persons in order to avoid a hazard.
Check that all party walls are intact, seek
advice if the wall is missing or broken.
DO NOT REMOVE OR TAMPER
WITH ELECTRONIC CIRCUIT
BOARD
This is not a user function.
6
5
FIXING KIT
Contents
8 X FOAM PADS
4 X PLASTER BOARD PLUGS
4 X PENNY WASHERS
ROLL OF INSULATION TAPE
4 X WOOD SCREWS (10 X 1.5)
4 X WOOD SCREWS (10 X 3)
4 X WOOD SCREWS (8 X 1)
4 X WOOD SCREWS (8 X 1.5)
4 X CABLE TIES

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
0845 27 27 810
ECO2Air Twin & ECO2Loftight Twin
INSTALLATION DIAGRAMS
STANDARD INSTALLATION
Installation diagram for the ECO2Air Twin & ECO2Loftight Twin
UNIT DIMENSIONS
Dimensions of the ECO2Air Twin
Unswitched fuse spur tted
with 3 Amp fuse
230V A.C.
3 core mains lead
For xing instructions, please
refer to the xing instructions
(gure 1) on page 5
650mm x 50mm x 25mm batten
Ceiling joists
Contents for unit
1 x Cardboard template
2 x Diuser
1 x Fixing kit
1 x Unswitched fuse spur
ø100mm Flexi duct
1 x Heater enable switch
or wireless control
1 x Filter
Supply Voltage
• 230V
• 50Hz
• 525W max
Heater enable/disable switch
(Non Wireless-Heater version
only) Fresh air delivered
into dwelling
Fresh air drawn
from outside
405mm
ø150mm
ø100 mm

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
0845 27 27 810
ECO2Air Twin & ECO2Loftight Twin
INSTALLATION INSTRUCTIONS
SECOND STAGE
Position the ECO2Air Twin or ECO2 Loftight Twin unit on 50mm x 25mm wooden battens (not supplied) laid across the
joists or raised platform if the insulate is thicker than the joists so that the trunking between the unit and the diuser
is not impeded. Lightly screw the drilled battens to the joist through the rubber mounts and metal penny washer
provided. Fit the trunking to the unit spigot using half of the tape provided.
THIRD STAGE
Push ducting through the hole in the ceiling. Return to the hallway and connect the ducting onto the neck of the
diuser using rest of the tape provided. Ensure that the diuser is aligned correctly with the walls of the hallway. Adjust
if necessary. Fix the diusers in position using plasterboard plugs and the screws provided.
FOURTH STAGE
Fit the lter as per the diagram below (ECO2Air Twin only)
Fig.1 Fixing Instructions
FIRST STAGE
Position a dustsheet beneath the site you have
chosen for cutting the hole for the diuser. Protect
your lungs with a mask. Enter the loft space with the
ECO2Air Twin or ECO2Loftight Twin unit and check
there are no obstructions to your chosen position for
the diuser. Using the template supplied mark the
hole for the diuser and cut the Ø107mm holes in the
plasterboard.
Use the distance from the unit to each hole to balance/
favour airow:
i. Equal air supply required - diusers equidistant from
unit
ii. More air supply required in hallway - short run to
diuser in the hall
(This is the recommended method of installation)
10 x 3 screw
Penny washer
Foam pad
Foam pad
50mm x 25mm
batten with 20mm
clearance hole
Existing joist
2. First locate the rods (provided)
to support the lter.
3. Then velcro the lter into position.
Detail
1. As soon as the unit is
secured in desired location,
place the lter on.
N.B For installations in 3 storey dwellings, the unit should
be linked to the dwellings smoke alarm system and tted
with a steel re diuser, part number: KIT-PIV-SMOKE.

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
0845 27 27 810
ECO2Air Twin & ECO2Loftight Twin
INSTALLATION INSTRUCTIONS
FIFTH STAGE - Fitting the inline lter
Filter location - The lter should be located in the supply airow between the external input point and the unit. It is
recommended that it is tted directly to the ECO2 Loft Unit spigot in a section of Ø150mm x 350mm (min) ridged
duct. See Fig.4.
Filter Orientation - The cone lter should always point towards ECO2Air Twin and ECO2Loftight Twin.
Fixing and sealing - The lter should be fully sealed into the ducting, however it should not be permanently bonded
into position, this is to allow for removal of the lter during maintenance. Use a exible section as shown in Fig 1 &
Fig 4 to aid removal, 300mm is recommended. Always apply the label provided to the lter location, this is to assist
future lter maintenance (Fig 3).
Installation congurations - For sample congurations see (Fig 2).

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
0845 27 27 810
ECO2Air Twin & ECO2Loftight Twin
INSTALLATION INSTRUCTIONS
Maintenance - For maximum eciency of the unit, it is recommended that the lter is cleaned every 24 to 36 months
by a competent person. Use a vacuum cleaner, a soft brush or warm water (air dry fully before replacing).
Size
Fig 3.
Filter Assembly
Filter Ø150mm x 350mm Link
Seal Seal, if required
Ridged / FlexiDuct
300mm Flexi
Section
ECO2Air Twin

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
0845 27 27 810
ECO2Air Twin & ECO2Loftight Twin
Solar Gain
1
2
3
SIXTH STAGE
Choose a location for the fresh air intake and drill a
ø158mm (or ø132mm) hole for wall kit. Depending
on the layout of your attic, you have three options for
locating the input of fresh air (wall input; roof input
and under tiles input). If ø125mm wall / roof kit is
installed, use an ø150mm adaptor to connect to the
unit with ø150mm insulated ducting. Make sure that all
connections are sealed well.
It is recommend that ø150 intake vent is used for best
performance
1
2
3
Fresh air drawn from outside - Wall Input
Fresh air drawn from outside - Under Tiles Input
Fresh air drawn from outside - Roof Input
Delivering Fresh Air - Options
SEVENTH STAGE
The ECO2Air Twin and ECO2Loftight Twin units must only be installed by a competent person and should be
connected to an electrical supply in accordance with the current electrical regulations. A disconnection device should
be used in the xed wiring. Connect the heater enable cable to the switch provided (non wireless versions only).
EIGHTH STAGE
Check the unit is working correctly. Set the unit’s controls according to the house size and check that the lters are
securely in place.
NINTH STAGE - Manual settings
Method of operation: Adjust the settings on the top of the unit by pressing the house setting button. By pressing the
button, the correct ventilation rate for the size of the house can be selected i.e. if the unit is on SMALL / TRICKLE and
the button is pressed, the unit will then switch to MEDIUM. Similarly, if the unit is on BOOST and the button is pressed,
the unit will then switch to SMALL / TRICKLE. The manual setting panel can be found on the side of the ECO2Air Twin
unit and top of the ECO2Loftight Twin unit.
SMALL / TRICKLE MEDIUM
PRESS BUTTON
LARGE BOOST
INSTALLATION INSTRUCTIONS

SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL
0845 27 27 810
ECO2Air Twin & ECO2Loftight Twin
NINTH STAGE cont. - Wireless units only
For heater enable/disable
To change speed setting
On commission the unit
will default to the trickle
ow rate with heater
enable on
Press button for ve
seconds turns heater
enable o. LED will
ash red for a few
seconds
Press button for ve
seconds turns heater
enable on. LED will
show constant red for a
few seconds
Press button once, to
indicate current fan
speed and heater status.
LEDs stay on constant
for a few seconds
Next press moves the unit to the
next speed and so on. When the
speed is chosen the LED remains
on for a few seconds
If the two LEDs situated just above
the button ash alternately red and
green (when it is pressed) the control
will need to be reprogrammed.
Call your maintenance company or
EnviroVent for advice.
Heater enable ON
Auto LED stays on constant for a few
seconds.
Heater enable OFF
Auto LED ashes for a few seconds.
Boost
(Green)
Remote Control out of range (Red)
Heater enable
(Red)
Remote Control
in range
(Green)
When the battery needs replacing, unscrew the front
cover. The battery is located on the back of the cover.
Battery type - 3V Lithium, CR2032
(Green)
LED Colours
Constant Red
Flashing Red
Constant Green


EnviroVent Ltd
EnviroVent House
Hornbeam Business Park
Harrogate
HG2 8PA
T 0845 27 27 807
F 01423 810 910
www.homeventilation.co.uk
E&OE | MKT ENV248-V3-28.03.14
Due to our policy of continuous innovation and
improvement EnviroVent reserves the right to alter
products specication and appearance without
notice.
AFTER INSTALLING THIS FAN PLEASE PASS ONTO END USER - DO NOT THROW AWAY
Please read carefully to ensure simple installation and a
long trouble free life for the user.
This manual suits for next models
1
Table of contents
Other Envirovent Air Cleaner manuals