Hardware Contents:
1.
RadioSecure SLM Device
2.
Stainless Steel wire rope with header
3.
Horizontal bolt
4.
Locking Barrel
5.
Sim window cover

` 3
ENVOTECHNETWORKSDNBHD(657306‐W)
25,JalanKilang2,KawasanPerindustrianJelapang(TamanPertama),
30100Jelapang,Ipoh,Perak,Malaysia.
Tel:+6055278287/+6055279287Fax:+6055261287
SIM Card installation
RadioSecure SLM is delivered with SIM Window Cover unattached.
User is to follow the following procedure to insert SIM and
subsequent closing the window to retain the IP67.
Check that Green Reset Plug is inserted and secured.
Use a pair of long nose plier or a pair of tweezer to grip the sim card.
Hold the SLM at eye level and gently insert the sim card into the sim holder
with the contact face down.
Apply sufficient Silicon base adhesive such as
Loctite 5607 to the groove around the SIM
window.
Align SIM window cover with arrow facing
down and gently press to lock the SIM
window cover.
Leave it to cure according to manufacturer’s
instruction.

` 4
ENVOTECHNETWORKSDNBHD(657306‐W)
25,JalanKilang2,KawasanPerindustrianJelapang(TamanPertama),
30100Jelapang,Ipoh,Perak,Malaysia.
Tel:+6055278287/+6055279287Fax:+6055261287
Charging the RadioSecure SLM
RadioSecure SLM is delivered with the battery charged to
approximately 25%. Before deploying the RadioSecure SLM, make a
full charge of the battery with an appropriate charger. (3hrs with
4amp rapid charger).
To charge the battery,
slide the interface connector sliding window to the left.
unscrew green reset plug.
Align charger receptacle to connector by aligning the key to the key-way and
gently push down to mate.
Switch on charger and leave it to charge for the required period. When fully
charged, the charger indicator will turn green

` 5
ENVOTECHNETWORKSDNBHD(657306‐W)
25,JalanKilang2,KawasanPerindustrianJelapang(TamanPertama),
30100Jelapang,Ipoh,Perak,Malaysia.
Tel:+6055278287/+6055279287Fax:+6055261287
Preparing RadioSecure SLM for deployment:
RadioSecure SLM with fully charged battery is stored with reset plug inserted
and securely tightens. The reset plug disconnects power supply to the CCA.
The following procedure and visual observations should be observed in
deploying the RadioSecure SLM.
1. Slide the interface connector window to left, unscrew green reset plug.
2. Red LED start blinking for approximately 45s (system initialization).
3. Red LED latched (system completed initialization).
4. Red and Green LED latched (GSM initialization).
5. Red LED latched, Green LED blink (GSM primary login).
6. Green LED latched (RadioSecure SLM ready for commissioning).
7. Insert header end of the stainless steel wire rope into the larger hole on
the top of RadioSecure SLM.
8. Insert Horizontal Bolt and lock it with locking barrel.
9. Pass stainless steel wire rope through the hasp of object to be sealed and
insert the taper end of the cable through the smaller hole.
10. Pull to seal tight.

` 6
ENVOTECHNETWORKSDNBHD(657306‐W)
25,JalanKilang2,KawasanPerindustrianJelapang(TamanPertama),
30100Jelapang,Ipoh,Perak,Malaysia.
Tel:+6055278287/+6055279287Fax:+6055261287
Unseal and Decommission the RadioSecure SLM
To end journey, the following procedure and observation should be observed.
1. pull the horizontal bolt to left.
2. use a sharp bolt cutter to cut the bolt at the recess area.
3. grip the locking barrel and pull out the remaining portion of the horizontal bolt.
4. pull the stainless steel wire rope out from the smaller hole (left).
5. un thread the stainless steel wire rope from the hasp.
6. pull out the remaining end (with the header) to access the interface connector.

` 7
ENVOTECHNETWORKSDNBHD(657306‐W)
25,JalanKilang2,KawasanPerindustrianJelapang(TamanPertama),
30100Jelapang,Ipoh,Perak,Malaysia.
Tel:+6055278287/+6055279287Fax:+6055261287
7. align green reset plug to the interface connector and gently pressed while turning
clockwise.
8. the RadioSecure SLM has successfully completed an assignment and is in deep
sleep.

` 8
ENVOTECHNETWORKSDNBHD(657306‐W)
25,JalanKilang2,KawasanPerindustrianJelapang(TamanPertama),
30100Jelapang,Ipoh,Perak,Malaysia.
Tel:+6055278287/+6055279287Fax:+6055261287
Maintaining the SLM
RadioSecure SLM has a delicate Floating Mechanism which requires
maintenance. Maintenance schedule shall depend on usage
environment. It is advisable to carry out monthly maintenance for
normal usage. Usage in dusty environment may require more
frequent maintenance.
1. Dust off any visible sludge or dust accumulated in or around the cable-header
insertion hole, cable end insertion hole and the horizontal bolt insertion hole.
2. Spray light lubricant into these three holes.
3. Hold SLM with drain hole facing downward and in an angle where excess
lubricant can be drained.
Cable header insertion hole Horizontal bolt insertion hole
Cable end insertion hole
Drain Hole

` 9
ENVOTECHNETWORKSDNBHD(657306‐W)
25,JalanKilang2,KawasanPerindustrianJelapang(TamanPertama),
30100Jelapang,Ipoh,Perak,Malaysia.
Tel:+6055278287/+6055279287Fax:+6055261287
4. In the event that force is applied to pull the cable out of the locking mechanism
without removing the H-bolt, the locking cam will “bite” the cable resulting cable
unable to be removed. To release the bite, push/pull cable downward, pull out H-bolt
and then the cable. Spray lubricant into the cable inserting hole to remove metal
filings.

FCC WARNING
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
This device must be installed to provide a separation distance of at least 20 cm from all persons
and must not be collocated or operating in conjunction with any other antenna or transmitter.
NOTE 1: Any changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.
Table of contents
Popular Security System manuals by other brands

Bosch
Bosch Plena Power Amplifier Software manual

Federal Signal Corporation
Federal Signal Corporation WV450XL Series Installation and maintenance instructions

Whelen Engineering Company
Whelen Engineering Company 295HFS5 Series Installation & operating manual

Panasonic
Panasonic KX-HNS105AZ installation guide

Velleman
Velleman CCTVPROMT1 Quick installation guide

DSC
DSC PC 5010 instruction manual