2GB
100 cm
(75 cm)
10 cm
80 cm minimum130cm
10 cm
43 cm
a) b)
a) without mill: minimum distance 10 cm
b) with mill: minimum distance 58 cm
Special Instructions
During operation of the sauna, very high
temperatures are created within the cabin and
particularly at the stove. If the stove is not
installed correctly there will be a fire hazard.
Please read these installation instructions
carefully. You should pay particular attention to
the specified measurements and to the
instructions below.
lThisdevice has notbeen designed forbeing used
by persons (including children) that are physically
ormentallyhandicappedorhavesensorydisabilities.
Moreover,itisnotallowedtouse this devicewithout
sufficient experience and/or knowledge, unless
these persons will be supervised by persons
responsible for their security or in case they have
been instructed how to use this device.
lChildrenaretobesupervisedinordertomakesure
that they do not play with this device.
lThesaunaheatingunitis designedforoperationwith
aninput voltageof400VAC 3N through the sauna
controlunit.
lInstallation and electrical connection of the sauna
heating units, the control unit and other electrical
components must be performed by a qualified
electrician.Thespecialsafetyrequirementsspecified
inVDE 0110v.§49DA/6 and VDE 0100, Part703/
2006-2 must be observed during electrical
installation.
lThe sauna heating and control units may be used
onlyinsauna cabins constructed of suitable,resin-
free,untreatedmaterial(e.g.Nordicspruce).
lThesaunacabinmusthaveaminimuminsideheight
of 2.10 m.
lOnlyonesaunaheaterprovidingtherequiredheating
outputmaybeinstalledinthesaunacabin(seeTable
2.
lEvery sauna cabin must have a fresh-air inlet and
anexhaust outlet.Allventilation inlets/outletsmust
be positioned behind the sauna heating unit and
approx.5-10cmabovethefloor.Minimuminlet/outlet
dimensions are listed in Table 1.
lTheexhaust outlet must be positioned inthe lower
sectionoftherearwallofthesaunacabin,diagonally
oppositethesaunaheating unit.Fresh-airinletsand
exhaustoutletsmustnotbe closed. Please observe
the instructions provided by your sauna cabin
supplier.
lCaution: Covered or improperly filled stone
grates can cause fire hazards.
Please ensure that no objects have been left
lying on the sauna heating unit prior to each
operation.
lCaution: Due to the high temperatures generated
during operation of the sauna heating unit, direct
contact with the unit can cause burns.
lThe sauna heating unit is not designed for
installation/use in a niche, beneath the reclining
benchorbeneath an inclined ceiling.
lThesaunaheatingunitmustnotbeoperatedwhen
the fresh-air inlet is closed.
lCabinlightingandlighting installation components
mustbesplash-resistantandsuitableforoperation
at environmental temperatures of up to 140°C.
Therefore,onlyVDE-testedsaunalightingsystems
(max.40Watt)may be used in connection with the
saunaheatingunit.
lThe complete sauna system (sauna heating
unit, control unit, lighting system, etc.) may be
connected to the main power system by a
locally certified electrician only. All electrical
wiring installed inside the cabin must be suitable
foruseatenvironmental temperatures ofupto140°
C. Silicone cables are recommended. If single
filament cables are used, they must be protected
with flexible metal tubing. Minimum diameters for
connection cables and suitable cabin sizes for
specific heating output values in kW are listed in
Table2.
lWhen installing the sauna heater, please ensure
that the vertical height between the top surface of
the sauna heater and the roof of the sauna is at
least 130 cm, and that the horizontal separation
between the heater and the cabin wall or other
flammable materials is at least 10 cm. Ensure that
theheaterisnotplacedonafloormadefromhighly
flammable materials (e.g. wood, plastic flooring).
Ceramic tiles or similar are most suitable for the
saunaarea.
lThedistancebetweentheheaterguardand/orbench
and other flammable materials must be at least 10
cm. The height of the heater guard must be the
same as the height of the front of the stove.
lTobeusedwith allEOSsaunacontrolunitssuitable
foradditionalpowercontrolunits.