BEDIENUNGSANLEITUNG EE75
USB - Schnittstellenkabel
MANUAL EE75
USB - interface cable
Langwiesen 7
A-4209 Engerwitzdorf
Austria
T: +43-7235-605-0 F: +43-7235-605-8
E: [email protected] www.epluse.com
1. Belegung USB - Schnittstellenkabel / Assignment USB - interface cable:
Litzenfarbe / colour of wire: Signal / signal: Terminal Nr.:
grün / green D+ 11
weiß / white D- 12
rot / red Vbus 13
schwarz / black USB-GND 14
Schirmung / shielding
Eine Verlängerung des USB Kabels kann zu Kommunikationsproblemen führen.
Lengthen the USB cable can cause communication problems.
2.a) Anschlussbild Klemmleiste / Connection diagram terminal:
2.b) Anschlussbild Stecker - optional / Connection diagram plug - optional:
BA_EE75_USB_Kabel_04 // Technische Änderungen vorbehalten / technical data are subject to change // 302346
USB-Schnittstelle / USB-interface
Versorgung / supply
Analog Ausgänge / analogue outputs
Messfühler / sensing probe
braun / brown
grün / green
weiß / white
rot / red
schwarz / black
schwarz / black
orange / orange
rot / red
Schirm / shield
Bezeichnung Buchsenbelegung
description:connection assignment:
D+ 3
D- 1
V-bus 2
GND 4
Euro-Norm
Euro-Standard
Stecker für PC - Schnittstelle
plug for PC - interface
(Ansicht von vorne / front view)
Schirmung / shielding
3. Handhabung der USB-Schnittstelle:
Konfigurationssoftware installieren und USB-Schnittstelle einrichten (siehe
Bedienungsanleitung “Konfigurationssoftware”, Kapitel 2).
Wichtig: Zu Beginn der Routine darf der Messumformer nicht mehr an der
Stromversorgung angeschlossen sein!
1. Belegung der Klemmen des Messumformers und Anschluss der USB-Schnittstelle
im spannungsfreien Zustand im Gehäuseunterteil durchführen
2. Gehäuseoberteil aufsetzen und festschrauben
3. EE75 an Spannungsversorgung (VCC) anschließen
4. PC und EE75 mittels USB-Kabel verbinden
Achtung: zuerst USB-Kabel an EE75 anstecken, erst danach am PC
5. Konfigurationssoftware starten
6. Zugewiesene COM-Port-Nummer eingeben, welche in der Systemsteuerung von
MS Windows ersichtlich ist: Start -> Einstellungen -> Systemsteuerung -> System ->
Hardware -> Gerätemanager -> Anschlüsse (COM und LPT)
7. Konfigurationsänderungen durchführen
Achtung: Die USB-Verbindung darf während des Konfigurationsvorgangs nicht
unterbrochen werden, denn das kann zur Blockierung der USB-Schnittstelle am PC
führen. Sollte dies der Fall sein, muss die EE75-Konfigurationssoftware bei unter-
brochener USB-Verbindung geschlossen werden. Daraufhin wieder ab Punkt 4.
fortfahren.
8. Konfigurationssoftware beenden
9. USB Stecker zuerst am PC ziehen, erst danach Verbindung am
Messumformer lösen!
Using the USB-interface:
Install configuration software and USB-interface (refer to manual “configuration
software”, chapter 2).
Important: Starting the procedure the transmitter should be disconnected from any power
supply!
1. Connect terminals and USB-interface located in the back module of the EE75
housing under zero-potential conditions
2. Replace and secure the upper module of the housing
3. Connect EE75 to the supply voltage (VCC)
4. Connect the computer with the EE75 using the USB interface cable
Attention: Connect USB-cable first to EE75 and afterwards to PC
5. Start configuration software
6. Enter assigned COM-port-number, which can be found in the system properties of
MS Windows: Start -> Settings -> Control Panel -> System -> Hardware -> Device
Manager -> Ports (COM and LPT) – expand to Communications Port
7. Enter configuration modifications
Attention: USB-connection must not be disconnected during configuration process
due to the possibility that this could cause a hang-up of the USB-interface of the PC.
In that case please close EE75 configuration software while USB-connection is
interrupted. Thereafter please proceed again from point 4.
8. Exit configuration software
9. Disconnect the USB interface cable at the computer first; than disconnect the EE75
transmitter!
BEDIENUNGSANLEITUNG EE75
USB - Schnittstellenkabel
MANUAL EE75
USB - interface cable
Langwiesen 7
A-4209 Engerwitzdorf
Austria
T: +43-7235-605-0 F: +43-7235-605-8
E: [email protected] www.epluse.com

Other manuals for EE75

1

Popular Cables And Connectors manuals by other brands

Staubli MA231 Assembly instructions

Staubli

Staubli MA231 Assembly instructions

Amphenol PL18 30 Series Assembly manual

Amphenol

Amphenol PL18 30 Series Assembly manual

Philips SWV3442W Specifications

Philips

Philips SWV3442W Specifications

ITT PS-00055-CU operating instructions

ITT

ITT PS-00055-CU operating instructions

ELCART 42/12490-00 user manual

ELCART

ELCART 42/12490-00 user manual

Torqeedo 1974-00 operating manual

Torqeedo

Torqeedo 1974-00 operating manual

Flair 858080 instruction manual

Flair

Flair 858080 instruction manual

peerless-AV ACC800 manual

peerless-AV

peerless-AV ACC800 manual

CYP PUV-1H4HPL-AVLC Operation manual

CYP

CYP PUV-1H4HPL-AVLC Operation manual

Whirlwind W1 Technical data

Whirlwind

Whirlwind W1 Technical data

Renesas 2368 Series user manual

Renesas

Renesas 2368 Series user manual

ESI MIDIMATE eX user guide

ESI

ESI MIDIMATE eX user guide

Festo NEBU-M8R3 Series Assembly instructions

Festo

Festo NEBU-M8R3 Series Assembly instructions

Philips SWV3472S/10 user manual

Philips

Philips SWV3472S/10 user manual

Masimo LNOP MP Series manual

Masimo

Masimo LNOP MP Series manual

Jabra GN1210 brochure

Jabra

Jabra GN1210 brochure

AFL LG 250 installation instructions

AFL

AFL LG 250 installation instructions

Tripp Lite N818-02M Specification sheet

Tripp Lite

Tripp Lite N818-02M Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.