manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Erco
  6. •
  7. Floodlight
  8. •
  9. Erco Kona User manual

Erco Kona User manual

3000049097
0816
EERCO GmbH
Postfach 2460
58505 Lüdenscheid
Brockhauser Weg 80-82
58507 Lüdenscheid
Germany
Tel.: +49 2351 551 0
Fax: +49 2351 551 300
[email protected]
www.erco.com
Kona
1
Projector
Floodlight
Lens wallwasher
Projector
Floodlight
Lens wallwasher
Mounting instructions
1
2
Projector
Floodlight
Lens wallwasher
Projector
Floodlight
Lens wallwasher
Floodlight
3000049097
33000049097
0.07
0.07
0.09
0.11
195x250x299
A (m2
)
D (mm) W (kg)
228x300x363
228x350x413
6.70
6.70
8.80
10.90
228x250x313
8
Projector
Floodlight
Lens wallwasher
English
Read the instructions carefully
before installation and com-
missioning!
Leave the instructions for
users/customers for future
reference!
Our updated product documen-
tation can be accessed at
www.erco.com/download.
General safety information
Warning!
Risk of electric shock!
Before carrying out maintenance and
installation on the luminaire, discon-
nect from the mains supply and also
from any other DALI control wiring, and
ensure that all power is switched off.
Warning!
Risk of falling parts!
Before working on the luminaire ensure
that no one is standing below.
Attention!
- Do not operate luminaires with da-
maged or missing safety glass.
- In case of damage or a defective LED
module, the entire luminaire must be
returned to the factory.
- When installing, always observe the
national installation and accident pre-
vention regulations.
Intended use
The luminaire is suitable for outdoor
and indoor use and is approved for a
height of light source exceeding 15m.
Dimensions (D), max. reference plane
for wind loads (A) and weight (W) are
detailed in Fig. 8.
Choosing the mounting location
Position the luminaire so as to avoid
operation in direct sunlight or near
other sources of heat. High ambient
temperatures can reduce the life and
efficiency of the control gear or LED
module.
Electrical installation
For 3-circuit installation: to avoid any
damage to the control gear, the neutral
conductor must never be connected or
disconnected during operation.
Overvoltage protection
ERCO uses electronic control gear with
overvoltage protection in accordance
with DIN EN 61547. If additional protec-
tion from spikes is required, e.g. when
switching off inductive loads, separate
overvoltage protection units should be
installed.
Luminaire with DALI control gear
- All cables, materials and devices used
must be suitable for mains voltage, as
the DALI signal is not transmitted using
safety extra low voltage (SELV).
- For general information on DALI, please
go to: www.dali-ag.org.
Notes on corrosion protection
Ensure that the powder coating is
not damaged during installation or
maintenance work. Any damage, which
becomes wet, can result in corrosion
occurring. In aggressive environments,
the installation and maintenance of
all parts will require the appropriate
protective measures. Chemicals damage
the corrosion protection.
Installation
Note: The arrow on the base plate indi-
cates the beam direction.
Mounting the base plate onto the
conrete plinth (Figures 1-4)
Use the washers supplied.
Caution! Always comply with the
standards and regulations in place for
the mounting location when selecting
the mounting parts. Ensure suitable
corrosion resistance as required for the
environment.
Note: The luminaire can be mounted
using heavy load rawl bolts
M6 ( 120mm) or M10 ( 153mm) in
accordance with the manufacturer’s
instructions.
Mounting the base plate on accesso-
ries (Fig. 1)
Base plate 120mm: The luminaire may
be mounted on the concrete anchor
33979 or the mounting plate 33982.
Base plate 153mm: The luminaire
may be mounted on the ground socket
33974, the concrete anchor 33981 or
the mounting plate 33982.
Use the washers and cylinder head
screws supplied (included with the
mounting accessory).
Note: Follow the accessory instructions.
Mounting on upright supporting pole
(Fig. 1)
The luminaire may be mounted on an
upright supporting pole of 60-89mm
using the traverse 34955, the attach-
ment 34953 and die clamping plate
34954.
Note: Follow the accessory instructions.
Mounting the luminaire (Fig. 5)
Connect the earth conductor to the
base plate.
Rotate luminaire into the required
position and tighten set screws to the
specified torque.
Rotating the luminaire (Fig. 5)
Rotate luminaire into the required
position and tighten set screws to the
specified torque.
Warning!
Risk of falling parts!
If the set screws are unscrewed too far
and the in/out marking on the base
plate lines up with the tongue, the
luminaire will detach from the base
plate. The luminaire may fall off and
injure someone below.
Tilting the luminaire (Fig. 6)
Attention! Tighten the screws to the
specified torque to prevent water pene-
trating the luminaire.
Rotating the beam (Fig. 7)
The beam may only be rotated when
using floodlights with oval flood cha-
racteristic.
Warning!
Risk of falling parts!
Always hold on to the attachment.
When opening the luminaire, the
attachment may fall off and injure
someone below.
Flashing of the LED module
It is normal for the LED module to flicker
when switching on and off.
Cleaning
Always clean carefully using a soft
cloth and a commercially available,
ph-neutral, alcohol-free, non-abrasive
cleaning agent.
Take care not to damage the powder-
coating.
Cleaning the safety glass
Safety glass can be cleaned with
cleaning agents that are also suitable
for glass-ceramic cooking hobs.
Disposal
In accordance with EU Directive
WEEE (Waste Electrical and Electro-
nic Equipment), luminaires must not be
disposed of with other household waste.
At the end of their life, luminaires must
be taken to the appropriate local facility
available for the disposal or recycling of
electronic products.

Other Erco Floodlight manuals

Erco Lightscan User manual

Erco

Erco Lightscan User manual

Erco Nadir IP67 User manual

Erco

Erco Nadir IP67 User manual

Erco Trion User manual

Erco

Erco Trion User manual

Popular Floodlight manuals by other brands

VelLight LEDA315 user manual

VelLight

VelLight LEDA315 user manual

OmniSistem Rocket Laser AL04 Series user manual

OmniSistem

OmniSistem Rocket Laser AL04 Series user manual

brennenstuhl Professional X 4000 MA operating instructions

brennenstuhl

brennenstuhl Professional X 4000 MA operating instructions

LSI Zone Sports Flood installation instructions

LSI

LSI Zone Sports Flood installation instructions

Somogyi Elektronic Home FLP 150/BK instruction manual

Somogyi Elektronic

Somogyi Elektronic Home FLP 150/BK instruction manual

LUMINELL SL1 Installation & user manual

LUMINELL

LUMINELL SL1 Installation & user manual

Eterna FL124BPIR installation instructions

Eterna

Eterna FL124BPIR installation instructions

AEL ACP Installation & maintenance instructions

AEL

AEL ACP Installation & maintenance instructions

Hubbell LED ALF-6LU-5K Series installation instructions

Hubbell

Hubbell LED ALF-6LU-5K Series installation instructions

NightSearcher WORKBRITE Series user manual

NightSearcher

NightSearcher WORKBRITE Series user manual

Eye Lighting HOF103 Installation & maintenance

Eye Lighting

Eye Lighting HOF103 Installation & maintenance

Sylvania Luminaires installation guide

Sylvania

Sylvania Luminaires installation guide

Leviton JCC JC090001 installation guide

Leviton

Leviton JCC JC090001 installation guide

Acclaim Lighting REA Information sheet

Acclaim Lighting

Acclaim Lighting REA Information sheet

Gewiss DEDALO B 15d HS manual

Gewiss

Gewiss DEDALO B 15d HS manual

Chauvet COLORdash Par-Quad 18 user manual

Chauvet

Chauvet COLORdash Par-Quad 18 user manual

GlacialLight GL-SD15 user manual

GlacialLight

GlacialLight GL-SD15 user manual

EuroLite LED SLS-5 QCL user manual

EuroLite

EuroLite LED SLS-5 QCL user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.