ErgoSafe ClickitUp CiU BalconyFixed User manual

Instruction Manual
CiU®BalconyFixed
by

ClickitUp®has a design and construction that is new on the market and the product is design protected by Ergo-
Safe AB.AB. Design right 002416248. 001-005. 3/3 2014
Contents
Safety ...........................................................................................................................................3
Reception - unloading ......................................................................................................................3
Installation .......................................................................................................................................4
Preparations prior to installation ......................................................................................................... 4
Installation.........................................................................................................................................5
Technical specication ........................................................................................................................ 7
Use ...................................................................................................................................... 8
Warranty.............................................................................................................................................8
Dismantling .................................................................................................................................... 8
Performancedeclaration.......................................................................................................................9

3
ErgoSafe AB | Reparatörgatan 1 | SE-302 62 Halmstad | +46 (0)10-480 47 00 | www
.ergosafe
.se
by
Safety
GLASS
The glass is safety glass - laminated.
Reception - unloading
ON DELIVERY
A delivery inspection of CiU Fixed/Balcony should be performed in order to discover and transport
damage or other defects on the packaging and/or product. Any delivery damage must be noted on the
shipping company’s consignment note and ErgoSafe must be notied at the latest one week after receipt
of the delivery. Thereafter, it is not possible to cite discrepancies regarding the delivery of CiU Fixed/
Balcony.
UNLOADING FROM PALLETS
Note that unloading must be performed in a specic order, otherwise personal injury can occur.
There is also a risk of product damage. Set the pallets on a at surface.
1. Start by removing the packaging plastic
2. Then lift o the sections that are to be installed from pallets
3. Remember to secure the sections remaining on pallets so these do not fall
Each section is individually secured on the packaging to
prevent CiU®Fixed/Balcony from falling during unload-
ing.
Loosen the straps gradually as CiU®Fixed/Balco-
ny sections are installed.Each package accom-
modates 6 sections of CiU®Fixed/Balcony.

by
4
Installation
Single cover cap with 2 screws
6 screws per section are supplied, intended to secure installed
sections.
Note! Screws for fastening in the substrate are not included.
Preparations prior to installation
Below follows a description of what is important to remember when installing CiU Fixed/Balcony.
Read through the manual before starting to install CiU Fixed/Balcony.
Each CiU Fixed/Balcony section is delivered ready-assembled. Sections are linked together to form a
system with the help of double cover caps and double baseplate mounts.
The substrate must be dimensioned according to applicable standards. When fastening to concrete
CiU Fixed/Balcony must be installed with sheet rubber against the concrete surface.
CiU Fixed/Balcony is delivered complete with cover caps and baseplate mounts, single or double
de-pending on what is specified on the order.
Post
Foot
Fixed glass
Deadload

5
ErgoSafe AB | Reparatörgatan 1 | SE-302 62 Halmstad | +46 (0)10-480 47 00 | www
.ergosafe
.se
by
2. Install all sections
Set out the other sections. Continue as per the same principle until all sections are in position.
Installation
1. Install the rst section
Set out a straight line where ClickitUp®is to be installed. Note that if the ground slopes the posts
will be in their bottom position at the ground’s highest point. Any adjustments are made as per
figure 3. If corners are to be installed, start with this. Place the rst section on the baseplate mounts.
Use the fastening fittings on the baseplate mounts that are designed for the glass balustrades
substrate. ErgoSafe encourages ClickitUp®to be fastened to a stable substrate, concrete or timber
joists.
Once the rst section is in position, prepare single/double mounts for the next section.

by
6
ErgoSafe AB | Reparatörgatan 1 | SE-302 62 Halmstad | +46 (0)10-480 47 00 | www
.ergosafe
.se
3. Adjust the height and i t the cover cap
Install level. Use a suitable tool, e.g. a spirit level. Screws are included for fastening sections.
6. Fitting permanent caps
Now to the finish of the CiU Fixed/Balcony installation. Fit the permanent cover caps, single or
double. Exercise care to align the cover cap with the outer edges of the post profi le.
4. Drill six ø5.5 mm holes after the section is installed level
5. Secure with STAPS B6, 3x38 SS HEX8 (supplied).

7
ErgoSafe AB | Reparatörgatan 1 | SE-302 62 Halmstad | +46 (0)10-480 47 00 | www
.ergosafe
.se
by
Technical specification
Description Glass balustrade
Safety The glass is safety glass - toughened laminated. ClickitUp® Fixed/Balcony
has been tested according to EN 12600:2002 pendulum impact test
Manufacturing
method
Structural glazing is used to t the glass to the aluminium posts
Baseplate mounts As standard there are baseplate mounts which are double or single.
cover caps cover caps are available as double and single mounts
Material Glass, aluminium and stainless steel
Glass Toughened laminated glass 8.76 mm
Height 1100 mm
Width straight
section
Max 1800 mm (depending on prevailing wind loads)
Surface treatment Natural anodised as standard. As an option at an additional charge, black ano-
dised or powder coated in a RAL colour (only xed posts)

by
8
Use
MAINTENANCE
In order for stainless steel details (the cover cap) to maintain their appearance they should be
polished annually.
Warranty
In order for the warranty to be valid the conditions A-C must be met:
A: When invoking the warranty, the seller must be contacted to assess the complaint with regard to the
warranty. The seller must confirm that the fault is of such a nature that it is covered by the warranty.
All interventions or measures on the product that do not go through ErgoSafe’s complaints depart-
ment invalidate the warranty and are entirely the responsibility of the person who has performed or
ordered the work.
B: When invoking the warranty, the product’s serial number must be stated as well as any pictures that
clarify what is being claimed on the warranty.
C: When exchanging parts, these must unconditionally be returned to the seller. If this does not
occur, the customer loses the right to warranty compensation.
The warranty does not cover: Incorrect installation or a settlement in the ground or timber struc-
ture.
Dismantling
When dismantling CiU Fixed
Note!
Risk of cuts
Exercise care when handling glass. The product consists of thermally tempered glass that, in the
event of incorrect handling, can break and cause injuries.
MATERIAL RECYCLING
All metals are sorted in containers for metal.
Plastic and rubber are sorted as inammable materials.
Glass is sorted as lling material.
ErgoSafe AB | Reparatörgatan 1 | SE-302 62 Halmstad | +46 (0)10-480 47 00 | www.ergosafe.se

9
ErgoSafe AB | Reparatörgatan 1 | SE-302 62 Halmstad | +46 (0)10-480 47 00 | www
.ergosafe
.se
by
Declaration of Performance for
ClickitUp®Balcony
Product:
Balcony system
Intended use:
Personal protection Balcony
Manufacturer:
ERGOSAFE
Reparatörgatan 1
30262 Halmstad, Sweden
Systems of attestation of
conformity:
2+
Notified body:
SP AB
Notified body no.: 0402
Has performed an initial audit and assessment of factory production control as well as performed the ongoing
supervision of factory production control and has issued certificates for factory production control (FPC) no.:
0402-CPR - SC1078-15
Essential characteristics
Performance
Harmonised technical specification
Geometric data (tolerances for
dimensions and form)
EN 1090-1, tolerance class 1
EN 1090-3 annex G
Weldability
NPD
Fracture toughness
NPD
Reaction to fire
Material class A1
EN 13501-1
Release of Cadmium
NPD
Radioactive radiation
NPD
Durability
Surface treatment according to
1090-2, degree of pre-treatment P3.
Surfaces painted according to EN
ISO 12944.
EN 1999-1-1
Deformation in serviceability limit
state
<30 mm at full load
EN 1090:2009+A1:2011
Execution classification
EXC2
EN 1090-3 Annex G
Fire resistance
NPD
Ultimate bearing strength
characteristics
NPD
Fatigue
NPD
This declaration of performance is issued under the sole responsibility
of ErgoSafe AB. Signed for and on behalf of the manufacturer by:
Halmstad 17/12/2016
Fredrik Johansson, CEO

10
by

11
ErgoSafe AB | Reparatörgatan 1 | SE-302 62 Halmstad | +46 (0)10-480 47 00 | www
.ergosafe
.se
by

ErgoSafe AB | Reparatörgatan 1 | SE-302 62 Halmstad | +46 (0)10-480 47 00 | www.ergosafe.se
Copyright © 2015 ErgoSafe AB.
Table of contents
Other ErgoSafe Fencing & Gate manuals
Popular Fencing & Gate manuals by other brands

Barrette
Barrette Plastic Lattice owner's manual

Geuther
Geuther 2764 manual

Zippity
Zippity Baskenridge Assembly instructions

Fortress Technologies
Fortress Technologies PURE VIEW GLASS BALUSTER AL13 HOME installation instructions

VEVOR
VEVOR D3602-4 manual

Safety 1st
Safety 1st Easy Close Metal quick start guide

WamBam
WamBam TRADITIONAL CLASSIC VF13003 Assembly instructions

Casanoov
Casanoov VELETA 350C180 instruction manual

U-Line
U-Line H-5615 manual

Fortress Building Products
Fortress Building Products OASIS installation instructions

Carlson
Carlson 2323 instruction manual

PS
PS Safemezz MGH Series Installation Instructions, Operation and Maintenance Manual