Eternal Lighting BT4812 User manual

Issue 2014
Model:
BT4812
Multi Voltage Bell / Chime Transformer
These instructions are provided as a guideline to assist you.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLATION
AND RETAIN FOR FUTURE REFERENCE
Pack contents:
1 x Bell transformer
4 x Fixing screws
4 x Wall plugs
FOR PRODUCT ADVICE:
• T: 01933 673 144
• F: 01933 678 083
Visit our website:
www.eterna-lighting.co.uk
INSTALLATION INSTRUCTIONS
A guide for qualied electricians
EVENTUALLY, YOU MAY WANT TO
REPLACE THIS PRODUCT:
Regulations require the recycling of Waste from
Electrical and Electronic Equipment (European
“WEEE Directive” eective August 2005—UK
WEEE Regulations eective 2nd January 2007).
Environment Agency Registered Producer: WEE/
GA0248QZ.
WHEN YOUR PRODUCT COMES TO THE END OF
ITS LIFE OR YOU CHOOSE TO REPLACE IT, PLEASE
RECYCLE IT WHERE FACILITIES EXIST DO NOT
DISPOSE WITH HOUSEHOLD WASTE.
CLEANING:
• Clean this transformer only with a soft dry cloth.
• Do not use any chemical or abrasive cleaners.
IF YOU EXPERIENCE PROBLEMS:
If you believe your product is defective, please return
it to the place where you bought it. Our Technical
Team will gladly advise on any Eterna Lighting
product, but may not be able to give specic
instructions regarding individual installations.
For breakage information visit:
www.eterna-lighting.co.uk

READ THIS FIRST:
Check the pack and make sure you have all of
the parts listed on the front of this booklet. If not,
contact the outlet where you bought this product.
This transformer must be installed by a
competent person in accordance with the
Building Regulations making reference to the
current edition of the IEE Wiring Regulations
(BS7671).
As the buyer, installer and/or user of this product
it is your own responsibility to ensure that this
transformer is t for the purpose for which you
have intended it. Eterna Lighting cannot accept
any liability for loss, damage or premature failure
resulting from inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard
and is intended for normal domestic service. Use
of this transformer for any other than its intended
purpose, may result in a foreshortened working life.
Switch o the mains before commencing
installation and remove the appropriate circuit fuse.
When working at heights, please use a suitable
platform.
Do not overload the transformer; check that the
total load does not exceed the maximum marked
on the transformer.
Disconnect the transformer from the electrical
supply before ash or high voltage testing.
Suitable for indoor use only.
This product is suitable for installation on surfaces
with normal ammability e.g. wood, plasterboard,
masonry. It is not suitable for use on highly
ammable surfaces (e.g. polystyrene, textiles).
Before making xing hole(s), check that there are no
obstructions hidden beneath the mounting surface
such as pipes or cables.
The chosen location of your new transformer should
allow for the product to be securely mounted and
safely connected to the mains supply.
Do not cover the transformer with any insulating
materials.
Ensure that the transformer will be accessible after
installation for maintenance or replacement.
Do not attach to surfaces which are damp, freshly
painted or otherwise electrically conductive (e.g.
metallic surfaces).
If the location of your new transformer requires
the provision of a new electrical supply, the supply
must conform with the requirements of the Building
Regulations making reference to the current edition
of the IEE Wiring Regulations (BS7671).
This product is designed for permanent connection
to xed wiring: this should be either a suitable
circuit (protected with a 5 or 6 Amp MCB or fuse)
or a fused spur (with a 3 Amp fuse) via a fused
connection unit. We recommend that the supply
incorporates a switch for ease of operation.
Make connections to the electrical supply in
accordance with the following code:
Live - Brown or Red
Neutral - Blue or Black
This transformer is double insulated, and the
transformer output is SELV (Safety Extra Low
Voltage). Do not connect any part to earth.
When making connections, ensure that the
terminals are tightened securely and that no strands
of wire protrude. Check that the terminals are
tightened onto the bared conductors and not onto
any insulation. Wrap loose terminal blocks well with
insulating tape.
You are advised at every stage of your installation to
double-check any electrical connections you have
made. After you have completed your installation
there are electrical tests that should be carried out:
these tests are specied in the Wiring Regulations
(BS7671) referred to in the Building Regulations.
INSTALLATION:
1) Choose the location for your new transformer
giving consideration to each of the points opposite.
2) Loosen the screw on the front of the case and lift
o the top.
3) Remove the xing kit.
4) Using the rear of the case as a template, mark the
xing holes on the mounting surface.
5) Secure the transformer in place using the xings
supplied. If the xings are not appropriate for your
installation use suitable alternatives.
6) Make the connections to your bell and/or bell push
according to the instructions supplied with them.
Check the Voltage required by your bell/sounder
and connect to the terminals as shown in g.1
below.
7) Make the connections to the mains supply as
detailed above.
8) Replace the front of the case.
9) Restore the power supply and switch on.
REPLACEMENT LAMP TYPE:
Supply Voltage: 240V 50Hz
Output Voltage: 4V 50Hz or
8V 50Hz or
12V 50Hz
Maximum Current: 1A
8V 4V 12V
DIAGRAMS BELOW SHOW HOW TO CONNECT TO THE CORRECT VOLTAGE
MAINS MAINS MAINS
N L N L N L
Fig 1
Popular Transformer manuals by other brands

Megger
Megger MTO 330 quick start guide

Monacor
Monacor IMG STAGELINE LR-1000T operating instructions

Williams Sound
Williams Sound IR T2-POE KT1 Wiring guide

AUDAC
AUDAC Q2TR user manual

ORTEA NEXT
ORTEA NEXT ICAR MICROmatic HP10 Series Installation, operating and maintenance manual

Peavey
Peavey Automatch user guide