INTRODUCTION
Thank you for choosing our Euretech brand product. Our products have been subject to all
tests and checks required during the production stage.
You can find all the information required for the operation of the product you purchased with
full performance in a healty manner. Do not start to assemble the device before reading the
operation quidelines thoroughly.
GENERAL OVERVIEW
SKM series sediment filters are held up to sand, rust, mud etc. at a certain level of microns.
Filter operates manually, pollution accumulated in the cartridges is removed by manual
washing for stainless steel and nylon cartridges, by changing the cartridges periodically for
polyprophylene cartridges. Polyprophylene cartridges have 1-5-10 and 20 micron level
treatment sensitivity, washable cartridges have 50 micron level treatment sensitivity.
Multi cartridge filters have a high flow capacity of water treatment. Because of filter body is
made of stainless steel it is healthy and longlived.
WARNINGS AND PRECAUTIONS
Cut off the water supply and make depressurization before any intervention to the
filter.
Cartridges inside the filter should checked periodically. Stainless steel and nylon
cartridges should clean by washing pressured water. Polyprophylene cartridges should
change with the new ones periodically. Pollution on the cartridges should observed or
understanding from the pressure difference on the manometer.
Filters must not operated over 10 bar. Otherwise, stainless steel filter body is exposed
to the pressure and will stretch then water leakage will occur.

4
EUROSAN SU ARITMA SİSTEMLERİ SAN. ve TİC. A.Ş.
Organize San. Bölgesi 2. Cad. No: 4/4 Y.Dudullu-Ümraniye/İstanbul
Tel: 0216 499 84 66-67-68-69 Fax: 0216 499 84 70
ASSEMBLY INSTRUCTIONS
Filter should be mounted on a flat surface with full hygiene. The maintenance works
related to the device should be realized in a suitable a comfortable environment.
A clearance enabling the easy replacement of the cartridges should be left on the top
of filter. This clearance should be a little bit longer than the cartridges.
Inlet connection should done from top of the filter and outlet connection should done
from bottom.
By-pass line should be done to supply continous water while system in maintenance.
The precautions required fixing the inlet outlet connection lines of the filter and to
avoid water hammer should be taken.
TECHNICAL CHARACTERISTICS
Product Code
Model
Flow
(m3/h)
Flow
m3/h
Cartridge
Cartridge
Dimensions
Connection
Diameter
Dimensions
Weight
CP
CN-CX
Quantity
inc
inc
mm
kg
MM.SKM1.304
SKM 1
8
18
3
20
1 ½”
168X780
16
MM.SKM2.304
SKM 2
12
27
3
30
2”
168X1030
20
MM.SKM3.304
SKM 3
16
36
3
40
2”
168X1280
23
MM.SKM4.304
SKM 4
28
63
7
30
3”
273X1045
37
MM.SKM5.304
SKM 5
38
84
7
40
3”
273X1295
39
MM.SKM6.304
SKM 6
48
108
12
30
4”
329X1045
48
MM.SKM7.304
SKM 7
64
144
12
40
4”
329X1295
52
MM.SKM8.304
SKM 8
100
228
19
40
DN 125
400X1295
99
* Flow calculation has made according to 5 micron for CP cartridges, 50 micron for CN and
CX cartridges.

5
EUROSAN SU ARITMA SİSTEMLERİ SAN. ve TİC. A.Ş.
Organize San. Bölgesi 2. Cad. No: 4/4 Y.Dudullu-Ümraniye/İstanbul
Tel: 0216 499 84 66-67-68-69 Fax: 0216 499 84 70
CARTRIDGE INSERTION
1. Remove the top cover from the flange after the completion of the device assembly
(Picture 1)
2. Insert the cartridges to the slots inside the filter body. (Picture 2)
3. Put the washes on the top of the cartridges and tighten the wing nuts by hand power(
do not use any toll at this step) (Picture 3)
4. Reset the top cover and tighten the screws of flange by using allen key(Picture 4)
5. Place a manometer on the top of the collector (Picture 5)
6. After these steps check the leakproofness by giving water inside the filter.
OPTIMUM OPERATIONAL CONDITIONS
Max. Operating Pressure = 10 Bar
Min. Operating Pressure = 2 Bar
Operating Temperature = 2-45 ˚C

6
EUROSAN SU ARITMA SİSTEMLERİ SAN. ve TİC. A.Ş.
Organize San. Bölgesi 2. Cad. No: 4/4 Y.Dudullu-Ümraniye/İstanbul
Tel: 0216 499 84 66-67-68-69 Fax: 0216 499 84 70
TROUBLESHOOTING
Problem
Cause
Solution
There is a water leakage on
the inlet and outlet lines
Flanges did not well
screwed
Check the flanges
Fittings materials are
damaged
Change the fittings materials
There is a water leakage on
the manometer
Water entered in the
manometer or
manometer connection
part and damaged it
Change the manometer
There is a trouble at
manometer connection
point
Demount and reconnect the
manometer
Monometer does not make
pressure measurement
Manometer is out of
order
Change the manometer

7
EUROSAN SU ARITMA SİSTEMLERİ SAN. ve TİC. A.Ş.
Organize San. Bölgesi 2. Cad. No: 4/4 Y.Dudullu-Ümraniye/İstanbul
Tel: 0216 499 84 66-67-68-69 Fax: 0216 499 84 70
PERIODIC MAINTENANCE AND SERVICE INSTRUCTIONS
Although there is no need for continuous and comprehensive maintenance for our
filtration systems, they should be checked regularly.
Cut off the water supply and make depressurization before any intervention to the
filter.
Stainless steel and nylon cartridges are washed with pressured water periodically and
re-used. Approximate life time is 1 year.
Polypropylene cartridges are changed with the new ones approximately in 1,5 months.
This period is changing according to raw water pollution.
Pollution on the cartridges may follow of pressure difference on the manometer
without demounting.
This manual suits for next models
15
Table of contents
Popular Water Filtration System manuals by other brands

Panasonic
Panasonic ET-SFR510 operating instructions

JBL
JBL CristalProfi e491 greenline manual

NOVO
NOVO Clear 485 Installation and operation manual

EHEIM
EHEIM LOOPpro 8000 operating manual

JRC
JRC NSVS1108 manual

Franklin Water Treatment
Franklin Water Treatment POZ1 Series Installation instructions and owner's manual