Ezy Spa 104074 User manual

Ezy Spa Hot Tub
Instruction ManualImportant safety guidelines for hot tub usePlease read & understand prior to using your hot tub
ezyspa

23SPECIFICATION--------------------------------------------- 4 INSTALLATION-------------------------------------------- 5 ASSEMBLY--------------------------------------------------- 6 OPERATION OF SPA PUMP---------------------------- 10 SPA MAINTENANCE---------------------------------------- 15 SIMPLE TROUBLE SHOOTING--------------------------- 18CONTENTSSPECIFICATION104074U.S. Regulations MS-18068A4Persons800L(211gal) Φ180*68CM(Φ71”*26.7”) Φ140*68CM(55”*26.7”)68CM(26.7”) 108*3mm110~120V,60Hz,1250W 1200W(15℃water Temperature)650W 5.5mStyleEuropean regulations Product number Capacity Water capacity Outer diameterInner diameter HeightBubble jets RatedpowerHeater power Bubble jetpower Powercord lengthFilter pump specifications4Persons800L(211gal) Φ180*68CM(Φ71”*26.7”) Φ140*68CM(55”*26.7”)650W 5.5mAC12V/35W1880L/420gal/H Pool coverAC12V/50W 2300L/600gal/HΦ142*20cmΦ142*20cm1540W(15℃water temperature)68CM(26.7”) 108*3mm220~240V,50Hz,1545WⅠ.Model and Specification

45SPECIFICATIONINSTALLATION Ⅲ.INSTALLATIONA1:SPApool B1:Pump E1:HoseC1: Pool cover C2:PVCinflatablecover (optional)G1:Valvewrench J1:Backwatercover N1: Repair material ManualD1:Inflation tubeH1: Plug lock H2: KeyK1: Hosel L1: Waterproof repair patchF1:Filter CartridgeI1:Blocker M1:InstructionⅡ.Configuration ListNote: Check all accessories included3.1InstallationSiteRequirements Note:Thegroundshouldbeabletobeartheweightof the pool.Note:Thereshouldbeawaterdrainingsystemaround Note: In order to prevent the danger of electric shock, please do not use the adaptor to connect the pump. ImportantTips:The ground shall be smooth and flat, and there shall be no sharp objects. The user should also consider the totalweightoftheuser,SPAandwater,andensurethat the ground in the use area has Sufficient strength to support it. There is a good drainage system beside the installation area. If the SPA is installed in a place thatdoesnotmeetthesafetyrequirements,anyloss causedisnotcoveredbythewarrantybecauseitis caused by improper use by consumers.1) Indoor installa-tion:Somespecialrequirementsforindoorinstallationthat need to be paid attention to:◎DuringtheinstallationoftheSPA,duringthefilling anddrainingwater,watermayspillontheground.So floor drains and moisture-proof must be installed in this place.◎WhenSPAisused,itwillbringalargeamountof watervapor,andthereshouldbenoarticlesandappli-ancesthatareeasytobeaffectedwithdampintheuse area.Inordertoensureairqualityandusercomfort,it must be installed in a good ventilated environment.Note: Do not install SPA on carpets or other items that areeasydamagedbywater.2) Outdoor installation: ◎Thegroundwherespapoolisonmustbeflatandthere are no sharp objects such as branches and stones nearby.

67b)ConnectthepowerplugoftheSPApumpintotheadapt-edpowersocket,pressthebubblejetbuttontostart inflating the SPA pool (see figure 4 above)PleasefilltheairchamberonthesidewalloftheSPA pool first. If the inflatable top cover is provided, fillthetopcoveraswell. Tips: 1)Howtousethesafetyvalve. ◎ Open the cap of valve;◎ Insert the inflatable hose into the inlet to inflate andinsertthecapofthevalvewhentheinflationis complete;seeFigure5;◎ Deflation: open the cap of valve and let the air out slowlyfromthechamber;2)Howtousearotatedvalve:◎ Open the cap of valve;Press the red point on the up position.◎ Insert the inflatable hose into the air inlet and rotateitinplaceclockwise,andcoverthecapwhenthe inflationiscomplete;seeFigure6;◎ Deflation: open the cap of valve, press the middle redpointonthedownposition,lettheairslowlyout from the chamber.◎Donotuseinanenvironmentwiththetemperature below10degreesCelsius(50degreesFahrenheit).◎ItwillaffecttheheatingeffectofSPA. ◎AlsodonotexposeSPAtothesunforalongtime, whichwillshortentheservicelifeofSPA.◎ThereshouldbeagooddrainagesystemnearSPA pool,as SPA needs to drain.3.2SPApoolassemblyWarning: Please use SPA's matching pump to inflate the pool, and do not over inflate it. Please do not use other high-pressure air pumps for inflation. The normal workingpressureofthepoolis5.0KPa/0.87psi.Exces-sivepressurewillcausetoburstordamagethejoinsof the pool.a) Take the pool on the ground,connect the threaded end oftheinflatabletubetotheinletwithbubblemarkon thepump(seefigure1&2)andinflatetheSPApoolwith anotherendoftheinflatabletube.(seefigure3)1 2 3 4 ASSEMBLYASSEMBLY
ezyspa

3.3Useoflocksockets Insert the key into the hole in the middle of the socket and open or lock it in the direction of the switchshowninfigure8;Fillthewaterwithwaterhoseuntilthewaterreaches theprintedwaterlevellineontheinnerwallofthe pool.Warning:◎ Donotpluginduringfillingthewater.Takecareof thewaterhosetopreventthemfromfallingofftocause thewaterleakage.◎ Pleasecoverthepoolwellwhenyouheatthewater. ◎ Please make sure that the children use the pool under the supervision of adults.◎ When not in use, please cover the pool and lock the buckle to prevent children from entering the pool.3.5ReplacementpumpsBefore replacing the pump, cover the inlet and outlet on theinnerwallofthepoolwithabackwatercoverto preventthewaterfromflowingout,asshowninfigure 113.4Connectingthepumptothepool Note:Thepowerplugmustbepulloutbeforeconnecting the pump to the pool.◎ Assembling the filter cartridge Thefiltercartridgeisscrewedtothewaterinletwall ofthepoolandrotatedclockwise.Seefigure10◎ Fillthepoolwithwater89ASSEMBLYASSEMBLY
Table of contents
Popular Hot Tub manuals by other brands

CalderaSpas
CalderaSpas CalderaSpas Utopia Series owner's manual

anko
anko SS-601A user manual

CalderaSpas
CalderaSpas CANTABRIA owner's manual

Dimension One Spas
Dimension One Spas HYDRO SPORT Installation and owner's guide

Bestway
Bestway Lay-Z-Spa Maldives HydroJet Pro manual

Dimension One Spas
Dimension One Spas Nautilus Specifications