N.B.: The original, authentic version of this manual is the Dutch version produced by Fancom B.V. or one of its
daughter companies (referred to further as Fancom). Any modifications introduced to this manual by third parties
have neitherbeen checked norapproved by Fancom. Modifications are taken by Fancom toinclude translations into
languages otherthan Dutch and the insertion and/or deletion of text and/or illustrations to/from the original contents.
Fancom cannot be held liable for any damages, injury, guarantee claims and other claims relating to this type of
modification, in as far as these modifications result in a content that differs from the original Dutch version of this
manual produced by Fancom. For the latest information about product installation and operation, please contact the
customer service dept. and/or the technical service dept. of the Fancom company concerned. In spite of the care
taken when compiling this manual, if you should discover anyerrors, please inform Fancom B.V. in writing. Fancom
B.V, PO Box 7131, 5980 AC Panningen (the Netherlands).
Copyright © 2011 Fancom B.V.
Panningen (the Netherlands)
All rights reserved. Nothing from thismanual may be copied,distributed or translated into other languages, partly or
wholly, without express prior written permission from Fancom. Fancom reserves the right to modify this manual
without notice. Fancom can give no guarantee, neither implicit nor explicit, for this manual. All risks are for the user.
This manual has been compiled with the utmost care. If, however, you should discover an error, please inform
Fancom B.V.
Art.Nr. A5911787
GB111001

GreenLinkBox ELT Table of contents
GB i
Table of contents
1. General introduction .................................................................................................................................. 1
1.1 Documentation with the control computer.......................................................................................1
1.2 How to use this manual..................................................................................................................1
1.3 Fancom helpdesk........................................................................................................................... 1
1.4 F-Central FarmManager.................................................................................................................1
2. Safety instructions and warnings ............................................................................................................. 2
3. GreenLinkBox ELT ..................................................................................................................................... 3
4. Connecting the GreenLinkBox ELT .......................................................................................................... 4
4.1 Connecting the GreenLinkBox ELT directly to the PC....................................................................4
4.2 Including the GreenLinkBox ELT into an existing local network .....................................................6
4.3 Setting the local network to be able to connect via the Internet...................................................... 8
5. Frequently Asked Questions..................................................................................................................... 9
5.1 How can I check the speed of the network card?........................................................................... 9
5.2 Is it possible to login with more than one person?..........................................................................9
5.3 My IP-address is lost, how can I return to the factory default settings?........................................ 10
5.4 How can I check if the connetion settings are correct?................................................................. 10
6. Appendix 1: Overview GreenLinkBox ELT board.................................................................................. 11
7. Appendix 2: Side view GreenLinkBox ELT board.................................................................................. 12
8. Appendix: EG-declaration of compliance............................................................................................... 13

GreenLinkBox ELT General introduction
GB 1
1. General introduction
This manual has been compiled with the utmost care. If, however, you should discover an error, please inform
Fancom B.V.
1.1 Documentation with the control computer
The documentation consists of the following manual:
•Installer's manual
The installer's manual is intended for installers. This manual supplies information about connecting and
configuring the GreenLinkBox ELT.
Always keep this manual close to the GreenLinkBox ELT.
1.2 How to use this manual
Fancom uses the following symbols in this manual:
Suggestions, advice and remarks with additional information.
Warning indicating damage to the product if procedures are not carefully observed.
Warning indicating a hazard for humans or animals.
Example of an actual application of the described functionality.
Example of a calculation.
Describes the combination of keys required to access a certain screen.
Decimals
The control computer and this manual use a decimal point in values. For example: a weight is shown as 1.5 kg (not
as 1,5 kg).
1.3 Fancom helpdesk
For any questions and support, please contact your local Fancom Sales & Service Centre.
1.4 F-Central FarmManager
Virtually all Fancom equipment can be controlled and managed from a central location. This requires the F-Central
FarmManagersoftware package and a communication module. The screens in the control computers are also used
in F-Central FarmManager. This means you can start working immediately.

GreenLinkBox ELT Safety instructions and warnings
GB 2
2. Safety instructions and warnings
Read the safety instructions, regulations and conditions carefully before installing and/or using the system. Installing
the device and remedying any malfunctions must only be carried out by an authorized installer, according to the
prevailing regulations. The guarantee will notapply if this product is built into a switch boxin any way other thanthat
indicated by Fancom.
The network module is a piece of electronic apparatus. There is always a risk of a malfunction occurring.
Fancom has made every effort to ensure that an alarm is given in the event of an emergency.
Unfortunately, a 100% guaranteed cannot be provided as not all circumstances are under Fancom's
control. Fancom cannot be held liable for any damage caused by incorrect settings and/or non or partial
functioning of the entire installation. Ask your installer if the alarm outputs of each control computer have
been connected to a separate alarm circuit.
Inspect the network module regularly for any damage. Report any damage to your installer immediately.
A damaged control computer is dangerous!
Do not use running water (highpressure cleaners) to clean your controlcomputer. The network moduleis
water resistant, but not waterproof! Do not switch off the network module when houses are unoccupied;
otherwise there is the risk of condensation forming in the network module.
When mounting the computer, the following should be observed:
Never mount the network module near water pipes, drainage pipes etc.
Never mount the network
module in a place where the weather has direct influence (not in the sun, or in
places where the temperature can rise sharply, etc.).
Never mount the network module in a humid and/or dusty room and certainly not in the room where the
animals are present.
No condensation may take place in or on the network module.
Use the holes behind the cover screws on the corners of the box to securely fasten the network module.
Use gland nuts to connect the network module. Use the sealing plates supplied to seal the gland nuts
which are not used. Seal all gland nuts after connection to prevent the entry of dust, aggressive gases
and/or humidity.
To protect against lightning, place an over voltage protection device in the power supply of the network
module.
Take precautions against electrostatic discharge (ESD) when working on the control computer. Ensure
the workplace is clean and dry.
Use the wiring/cables indicated on the connection diagrams and follow all instructions (see installer
manual). Only apply power after the wiring has been connected correctly. Incorrect connections can
cause permanent damage. Before a new fuse is placed, the cause of the defect should be remedied by an
authorized installer. Only replace a defective fuse by a fuse of the same type (see connection diagram).

GreenLinkBox ELT GreenLinkBox ELT
GB 3
3. GreenLinkBox ELT
The GreenLinkBox ELT is an interface between the controller and a PC. Controller data areexchanged with the PC.
The GreenLinkBoxELT can be accessed through the FarmManager software. This manual will help to work with the
device correctly. The next chapters explain how to connect the GreenLinkBox ELT correctly. To be able to work with
the GreenLinkBox ELT proceed as follows:
1. Connect the GreenLinkBox ELT directly to the PC (see paragraph 5.1)
2. Include the GreenLinkBox ELT into an existing local network (see paragraph 5.2)
3. Set the local network to be able to connect via the internet (see paragraph 5.3)

GreenLinkBox ELT Connecting the GreenLinkBox ELT
GB 4
4. Connecting the GreenLinkBox ELT
4.1 Connecting the GreenLinkBox ELT directly to the PC
Connect the GreenLinkBox ELT to the network card of the PC using the yellow network cable (cross cable). The
figure below shows the connection scheme.
Disconnect the power before installation.
Figure 1: Connection scheme to connect the GreenLinkBox ELT directly to the PC.
4.1.1 Creating connection settings to connect the GreenLinkBox ELT to the PC
To be able to work with the GreenLinkBox ELT you have to create a network between the GreenLinkBox ELT and
the PC. To set up a network you have to perform the following steps:
The network card must be suitable for connection to a 10Mbit device. For more information see page 9.
1. Start the PC and go to Start Control panel.
2. Double click Network connections.
3. Right click the LAN connection you want to use.
4. Select Properties.

GreenLinkBox ELT Connecting the GreenLinkBox ELT
GB 5
5. Select Internet Protocol TCP/IP.
6. Click Properties.
Write down the original settings. If the pc has to return to a local network reinstate the original settings.
7. Change the settings of the Internet Protocol to:
IP address 192.168.2.111 (the last number may be chosen between 0 -
254, as long as the address is
unique in the local network)
Subnet mask 255.255.255.0
The netmask indicates which IP-addresses can be identified by the network card. In the example of
255.255.255.0 the network card can only communicate with network devices with an IP-address
beginning with 192.168.2.x.
8. Press 2x OK.
If you don’t want to connect the GreenLinkBox ELT to a network you are finished after completing this
step.

GreenLinkBox ELT Connecting the GreenLinkBox ELT
GB 6
4.2 Including the GreenLinkBox ELT into an existing local network
Connect the GreenLinkBox ELT to a local network card of the PC using the blue network cable (patch cable). The
figure below shows the connection scheme.
Disconnect the power before installation.
Figure 2: Connection scheme to connect the GreenLinkBox ELT to the PC with a switch / router.
If you already have an existing network you can make the GreenLinkBox ELT part of this network. Therefore you
have to determine if it is necessary to change the network settings. If the network has the same IP-address range as
shown in the table below you do not have to change settings. The GreenLinkBox ELT can then be connected to a
free port in the network using a normal network cable (not the supplied yellow cross cable). If the network has a
different IP-address range as shown in the table, the standard IP-address of the GreenLinkBox ELT must be
changed (see paragaph 5.2.2).
IP-Address range
Subnet mask
192.168.xx 255.255.0.0
192.168.2.x 255.255.255.0

GreenLinkBox ELT Connecting the GreenLinkBox ELT
GB 7
4.2.1 Changing the standard IP-address
After changing the IP-address you can check if the settings are correct. See page 10.
Change the standard IP-address on the PC
To change the standard IP-address of the GreenLinkBox ELTyou have to perform the steps explained in paragraph
"Creating connection settings to connect the GreenLinkBox ELT to the PC" page 4.
Reserve an IP-address that isnot yet in use in the current network. This IP-address will be assigned to the
GreenLinkBox ELT as described in the next section.
Change the standard IP-address on the GreenLinkBox ELT
To change the standard IP-address on the GreenLinkBox ELT:
1. Start a web browser on the PC.
2. Enter the IP-address of the GreenLinkBox ELT in the address bar and login using the installer’s password.
3. Go to the window System configuration:
4. Change the settings of the Internet Protocol to:
IP address The unique reserved IP-address in the previous step.
Subnet mask Same as entered on the PC.
5. Click on Send configuration.
The setting will only apply after the GreenLinkBox ELT has been off and on once.
If you want to use loop communication then you have to activate it (default loop communication is off). In the
drop down menu Select second port select Current-Loop. The GreenLinkBox ELT will automatically search
for the right baudrate. At the bottom op the page the Current-Loop status will be displayed.
Reinstate the IP-address of the PC
1. Reinstate the IP-address of the PC (see paragraph "Creating connection settings to connect the GreenLinkBox
ELT to the PC" page 4).
2. Remove the yellow cross cable.
3. Reconnect the PC to the network by using the original network cable.
4. Connect the GreenLinkBox ELT with the normal network cable to a free port in the network.
If you do not want to set the local network for global access you are finished after this step.

GreenLinkBox ELT Connecting the GreenLinkBox ELT
GB 8
4.3 Setting the local network to be able to connect via the Internet
4.3.1 Connecting with a VPN connection
For connection via the Internet Fancom advises a VPN connection. VPN can be used to set up a connection
between a device (e.g. pda, smartphone and PC) and your local network with the GreenLinkBox ELT. Once this
connection is made the device behaves like it is connected directly to the local network and can connect to the
GreenLinkBoxELT. Setting upa VPN network can be done with a commercial available VPN solution. Contact your
local IT provider to install a VPN solution according to your needs.
4.3.2 Connecting using portforwarding
The GreenLinkBox ELT behaves like a web server. When you have a permanent high speed Internet connection
this server can be made accessible via the IP-address you received from you local Internet Service Provider. The
used technique is called portforwarding. The settings for portforwarding must be made in the router and/or DSL
modem which are used in your local network. Check the manual of your router how to set up portforwarding or
contact your local IT provider.
Application
Port
Protocol
Web pages 80 TCP/IP
FarmManager 10000 UDP
Ports and protocols available for portforwarding in the GreenLinkBox ELT.
This setup is much less secure than using a VPN solution. Always change the default passwords to avoid unwanted
access.
The port for webpages can be changed in the GreenLinkBox ELT. Login as installer and go to the System
configuration page. Add /showport to the URL in the address bar of your browser and press Enter. An extra edit
value for the port setting will occur. If the port number is not default the edit value will always be visible at the System
configuration page. Port numbers are valid between 1024 and 65535.

GreenLinkBox ELT Frequently Asked Questions
GB 9
5. Frequently Asked Questions
5.1 How can I check the speed of the network card?
If the GreenLinkBox ELT is connected directlyto the PC ensure the network card is suitable for a 10Mbit device. Do
this by setting the speed of the network card to Auto:
1. Start the PC and go to Start Control panel.
2. Double click Network Connections.
3. Right click the network adapter used for the GreenLinkBox ELT and choose Properties.
4. Click Configure and choose tab page Advanced.
5. Select Speed & Duplex at the left side. Now the Value option appears on the right side.
6. Select Auto.
7. Click OK to finish.
5.2 Is it possible to login with more than one person?
No, only one person may be logged in at the same time.
Go to the main page and logout to be able to login using a different web browser or PC. After 5 minutes of
non-activitythe GreenLinkBox ELT automatically logs off. You will have to login again tocontinue. Setdipswitch 4 to
On, to set this automatic logout time to 1 minute.

GreenLinkBox ELT Frequently Asked Questions
GB 10
5.3 My IP-address is lost, how can I return to the factory default
settings?
If the IP-address of the GreenLinkBoxELT is lost it is always possible to return to the factorydefault settings. Using
a paperclip press for about 5 seconds on thebuttonNext to the Ethernet connection (see chapter8). The green LED
next to the power supply will illuminate. The GreenLinkBox ELT has now reverted to the IP-address 192.168.2.100
and netmask 255.255.0.0.
5.4 How can I check if the connetion settings are correct?
Check LAN connection
To check the new LAN settings you have to double click the LAN connection icon (see paragraph "Creating
connectionsettings toconnect the GreenLinkBoxELT to the PC" page 4 step 1 until 4) and select tab page Support.
The new LAN settings are shown in the window as follows:
Check the GreenLinkBox ELT connection with a web browser
If the network settingsare correct you can access the GreenLinkBoxELT via a web browser. Starta web browser on
the PC and enter the IP-address of the GreenLinkBox ELT in the address bar. As soon as a web page appears with
an login code this means the network has been configured correctly and the GreenLinkBox ELT can be used.
The web browser must support Java scripts. Web browsers on PC’s and notebooks usually suppor
t this.
However this is not always the case with pda’s en smartphones. The default browser delivered with an
Iphone, Ipad or android device supports this feature. Older devices with Pocket Internet Explorer do not
support Java scripts. Test your device for proper use.

GreenLinkBox ELT Appendix 1: Overview GreenLinkBox ELT board
GB 11
6. Appendix 1: Overview GreenLinkBox ELT board
Component
Description
Colour
CN 1 Boot connector
CN 2 FNet and Current loop connector
CN 3 Ethernet connection
CN 4 Power 5 Volt +/- 3%
CN 5 Connection for Wireless Module
LED 1 FNet Transmit Red
LED 2 IO-net or Current loop Red
LED 3 Ethernet active Yellow
LED 4 Ethernet link Green
LED 5 Supply voltage present Red
LED 6 Run led Green
LED 7 UDP communication Yellow

GreenLinkBox ELT Appendix 2: Side view GreenLinkBox ELT board
GB 12
7. Appendix 2: Side view GreenLinkBox ELT board
Component
Description
5Vdc Power connector
Ehternet Network cable connector
Reset Reset to default IP-settings (press 5 sec.)
Dipswitch S 1 IO-net termination resistor
Dipswitch S 2 FNet termination resistor
Dipswitch S 3 Block password change
Dipswitch S 4 Auto logout after 1 or 5 minutes
R- Loop connection
R+ Loop connection
T+ Loop connection
T- Loop connection
Gnd Loop connection
Fnet Fnet connection
The dipswitch functions are not active in the Off position.

GreenLinkBox ELT Appendix: EG-declaration of compliance
GB 13
8. Appendix: EG-declaration of compliance
Manufacturer Fancom B.V.
Address: Industrieterrein 34
Place: Panningen (the Netherlands)
Hereby declares that: GreenLinkBox ELT
Satisfies the conditions of:
1. The Low Voltage Directive 2006/95/EC according to EN-61010
2. the EMC Guideline, directive 2004/108/EC
Emission and immunity according to NEN-EN-IEC 61326
Panningen Date: 01-10-2011
Chris van Erp Roland Kruijtzer
Manager Technology Project Manager


N.B.: De originele, authentieke versie van deze handleiding is de door Fancom B.V. of door een van haar
dochterondernemingen (verder aangeduid als Fancom) geproduceerde Nederlandse versie. Achteraf door derden
aangebrachte wijzigingen in deze handleiding zijn door Fancom noch gecontroleerd, noch goedgekeurd. Onder
wijzigingen verstaat Fancom o.a. het vertalen in een andere taal dan het Nederlands en het toevoegen en/of
verwijderen van tekst en/of illustraties uit de originele inhoud. U kunt Fancom niet aansprakelijk stellen voor schade,
letsel en garantieclaims, en andere claims die verband houden met dit soort wijzigingen, voor zover deze
wijzigingen resulteren in een inhoud die afwijkt van de authentieke door Fancom geproduceerde Nederlandse
versie van deze handleiding. Voor actuele informatie over productinstallatie en bediening, neem contact op met de
klantenservice en/of technische serviceafdeling van de betreffendeFancom onderneming.Mocht u onverhoopt toch
een fout ontdekken, dan vragen wij u vriendelijk Fancom B.V. hiervan schriftelijk in kennis te stellen: Fancom B.V.,
PO Box 7131, 5980 AC, Panningen.
Copyright © 2011 Fancom B.V.
Panningen (Nederland)
Alle rechten zijn voorbehouden. Niets uit deze handleiding mag worden gekopieerd, gedistribueerd of vertaald in
andere talen, geheel of gedeeltelijk, zonder voorafgaande schriftelijke toestemming van Fancom. Fancom houdt
zich het recht voor wijzigingen in de handleiding aan te brengen. Fancom kan echter geen garantie geven, impliciet
noch expliciet, voor deze handleiding. Het risico hiervan ligt volledig bij de gebruiker.
Deze handleiding is met de grootst mogelijke zorg samengesteld. Mocht u onverhoopt toch een fout ontdekken, dan
vragen wij u vriendelijk Fancom B.V. hiervan in kennis te stellen.
Art.Nr. A5911787
NL111001

GreenLinkBox ELT Inhoudsopgave
NL i
Inhoudsopgave
1. Algemene inleiding..................................................................................................................................... 1
1.1 Documentatie bij de regelcomputer................................................................................................ 1
1.2 Hoe gebruikt u deze handleiding....................................................................................................1
1.3 Fancom helpdesk........................................................................................................................... 1
1.4 F-Central FarmManager™..............................................................................................................1
2. Veiligheidsinstructies en waarschuwingen.............................................................................................. 2
3. GreenLinkBox ELT ..................................................................................................................................... 3
4. De GreenLinkBox ELT aansluiten............................................................................................................. 4
4.1 De GreenLinkBox ELT rechtstreeks op de PC aansluiten.............................................................. 4
4.2 De GreenLinkBox ELT in een bestaand lokaal netwerk opnemen..................................................6
4.3 Het lokale netwerk dusdanig instellen dat het via internet te bereiken is........................................ 8
5. Meest gestelde vragen............................................................................................................................... 9
5.1 Hoe kan ik de snelheid van de netwerkkaart controleren?............................................................. 9
5.2 Is het mogelijk om met meer personen in te loggen?..................................................................... 9
5.3 Ik ben mijn IP-adres kwijt; hoe kan ik terugkeren naar de fabrieksinstellingen?.............................9
5.4 Hoe kan ik controleren of de verbindingsinstellingen kloppen?.................................................... 10
6. Bijlage 1: Overzicht print GreenLinkBox ELT...................................................................................... 11
7. Bijlage 2: Zijaanzicht print GreenLinkBox ELT.................................................................................... 12
8. Bijlage: EG-verklaring van overeenstemming........................................................................................ 13

GreenLinkBox ELT Algemene inleiding
NL 1
1. Algemene inleiding
Deze handleiding is met de grootst mogelijke zorg samengesteld. Mocht u onverhoopt toch een fout ontdekken, dan
vragen wij u vriendelijk Fancom B.V. hiervan in kennis te stellen.
1.1 Documentatie bij de regelcomputer
De documentatie bestaat uit de volgende handleiding:
•Installatiehandleiding
De installatiehandleiding is bedoeld voor installateurs. Deze handleiding geeft informatie over het aansluiten en
configureren van de GreenLinkBox ELT.
Bewaar deze handleiding altijd bij de GreenLinkBox ELT.
1.2 Hoe gebruikt u deze handleiding
In deze handleiding worden de volgende symbolen gebruikt:
Suggesties, adviezen en opmerkingen met aanvullende informatie.
Waarschuwing duidend op schade aan het product, als u procedures niet zorgvuldig uitvoert.
Waarschuwing duidend op gevaar voor mens of dier.
Voorbeeld van een concrete toepassing van de beschreven functionaliteit.
Voorbeeld van een berekening.
Beschrijft de knoppencombinatie om bij een bepaald scherm te komen.
Weergave van decimalen
Op de regelcomputer en in deze handleiding wordt de punt gebruikt als decimaal scheidingsteken. Bijvoorbeeld:
een gewicht wordt weergegeven als 1.5 kg (niet als 1,5 kg).
1.3 Fancom helpdesk
Voor eventuele vragen en ondersteuning kunt u de locale Fancom Sales & Service Centre raadplegen.
1.4 F-Central FarmManager™
Vrijwel alle Fancom apparatuur kan worden aangestuurd en beheerd vanaf een centrale locatie. Hiervoor dient u te
beschikken over het softwarepakket F-Central FarmManager en een communicatiemodule. De schermen van uw
computers worden ook in F-Central FarmManager gebruikt. Hierdoor kunt u direct aan de slag.