Farsun FG2600 User manual

Barcode scanner
User¶s Manual

2
Contents
Programming with Parameter.............................................................. 4
Interface selection...................................................................................... 6
Scanning Mode Setting............................................................................... 7
Keyboard wedge......................................................................................... 9
USB interface............................................................................................ 11
RS-232 Interface ....................................................................................... 12
Global Settings.......................................................................................... 16
Indication.................................................................................................. 21
EAN-13 and ISBN/ISSN.............................................................................. 22
EAN-8........................................................................................................ 24
UPC-A........................................................................................................ 23
UPC-E ........................................................................................................ 28
Code128 C................................................................................................. 28
Code 39..................................................................................................... 29
Code 93..................................................................................................... 32
Interleaved 2 of 5 ..................................................................................... 34
Industrial 2 of 5......................................................................................... 38
Matrix 2 of 5 ............................................................................................. 40
Codabar .................................................................................................... 37
Code 11..................................................................................................... 38
MSI/Plessey .............................................................................................. 44
UK/Plessey................................................................................................ 46

3
GS1 DataBar (GS1 DataBar Truncated)..................................................... 44
GS1 DataBar Limited................................................................................. 45
GS1 DataBar Expanded............................................................................. 50
Advanced Bar Code Data Formatting ....................................................... 51
Prefix................................................................................................... 51
Suffix................................................................................................... 52
Preamble ............................................................................................ 52
Postamble........................................................................................... 53
Code ID ............................................................................................... 48
Code ID position ................................................................................. 48
Code name transmission .................................................................... 49
Code length transmission ................................................................... 49
Case conversion:................................................................................. 49
Insert String G1 Setting....................................................................... 50
Insert String G2 Setting....................................................................... 50
Insert String G3 Setting....................................................................... 50
Insert String G4 Setting....................................................................... 51
FN1 substitution string setting ........................................................... 51
Truncate leading G5 String setting ..................................................... 57
Truncate ending G6 string setting ...................................................... 57
Replace String Setting......................................................................... 58
Appendix 1 ASCII Table 1-2....................................................................... 53
Appendix 2 Parameter bar code............................................................... 55
**Wireless Communication Setting.56
Wireless Channel...57
RF operĂƚŝŶŐŵŽĚĞ..58

4
Battery Status... 59
Programming with Parameter
It is need to scan more than one setting barcode to program the scanner
with parameter.
Program Parameters
Notice:
1. Please carefully read the User Manual before using the barcode scanner.
2. All software, including firmware, furnished to the user is on a licensed basis.
3. The right is reserved to make changes to any software or product to improve
reliability, function, or design.
4. The material in this manual is subject to change without notice.
.when poweredon,the wirelessfunction willautomaticallysendsignal
each11seconds.Foryourhealth,turn it offisrecommendedwhen not use.
5

5
The steps of programming are:
1. 6FDQWKH)XQFWLRQ6HWWLQJ%DUFRGH7KH6FDQQHUZLOOLVVXHDEHHS´
sound, and the Red LED is on until the program is finished.
2. Scan the parameters bar code. The parameters may be one or more than
one digits.
3. 6FDQWKHVHWWLQJEDUFRGH³)LQLVK6HWWLQJ´,ILWLVSURJUDPPHG
VXFFHVVIXOWKHVFDQQHUZLOOLVVXHD³EHHSEHHS´VRXQGEXWLVVXHD
³EHHSEHHSEHHS´VRXQGZKHQIDLOV
e.g.
˖
Set min. code length of Code 128 to 5 chars
˖
ƻ
1˖Open the manual and turn chapter "code128 ". Scan the setting bar code
³Scan Min. Code Length´
Scan Min. Code Length˄2 Digits˗00~99ˈ1*˅
ƻ
2˖Turn to the last page of this Manual Appendix 10 Parameter bar code,
VFDQWKHSDUDPHWHUEDUFRGH³´DQG ³´˖
0
5

6
ƻ
3˖6FDQ³)LQLVK6HWWLQJ´ILQLVKWKHVHWWLQJ.
Finish Setting
Set Factory Defaults
If you wish to return the base unit to the entire factory default settings (radio
FRPPXQLFDWLRQVHWWLQJLVQRWLQFOXGHGVFDQWKHEDUFRGH´Set Defaults´
Set Defaults
Interface selection
This scanner supports interfaces such as keyboard wedge, RS-232 serial
wedge, and USB interface.
Typically, host is able to identify the host port type automatically. In extreme
cases, host port may need setting manually if the host fails to identify it.
AutomaticIdentification*
USB

7
PS/2KeyBoard RS232
Scanning Mode Setting
Good-read off scanning Mode: The trigger button must be pressed once
to activate scanning. The light source of scanner stops scanning when there
is a successful reading or no code is decoded after the Stand-by duration
elapsed.
Select Good-read off scanning Mode *

8
Auto-detection scanning Mode: The scanner will start scan Automatically
if any object enter the scan area. The laser light of scanner stops scanning
when there is a successful reading or no code is decoded after the Stand-by
duration elapsed. Once the laser light stops scanning, the present object must
be remove away from the scan area to enable Auto-detect sensor.
Select Auto-detection scan
Press Scanning Mode˖It can continue scan barcode when the button is
continuing pressed.
Press Scanning Mode
Click Scanning Mode: When the button is click, the scanner will keep
scanning the barcode until the barcode is reader or the Stand-by duration
elapsed.
Click Scanning Mode
Continuous Scanning mode: the scan engine is always scanning and
decoding. The module will read the barcode which gets into the scanning
area automatically. Only when the barcode that has been read gets out of the
scanning area, the module can read the next barcode.

9
Select Continuous Scanning mode
Auto Continue mode: The scanner will start continuous scan Automatically
if any object enter the scan area. When there is no bar code is read for half a
minute, the scanner shutdown the laser line and exit continuous scanning
mode.
Auto Continue mode
Keyboard wedge
Keyboard type IBM ATˈPS/2 *

10
Other˄Reserved˅
Keyboard layout
USA *
Italian
French
Turkish F
Turkish Q

11
USB interface
USB device type
HID Keyboard* Virtual RS232 Port˄reserved˅
Note: Virtual RS232 Port need driver!
IBM Table Top USB IBM Hand-Held USB
USB OPOS Hand-Held
USB Keyboard layout
USA* German
French Other

12
RS-232 Interface
Baud Rate
2400
4800
9600*
19200
38400

13
57600
Handshaking
None
˖
Scan the bar code below if no Hardware Handshaking is desired
None˄Default˅
Standard RTS/CTS
˖
Scan the bar code below to select Standard RTS/CTS
Hardware Handshaking.
Standard RTS/CTS
RTS/CTS Option 1: When RTS/CTS Option 1 is selected, the scanner
asserts RTS before transmitting and ignores the state of CTS. The scanner
de-asserts RTS when the transmission is complete.
RTS/CTS Option 1
RTS/CTS Option 2: When Option 2 is selected, RTS is always high or low
(user-programmed logic level). However, the scanner waits for CTS to be
asserted before transmitting data. If CTS is not asserted within Host Serial
Response Time-out, the scanner issues an error indication and discards the

14
data
RTS/CTS Option 2
RTS/CTS Option 3: When Option 3 is selected, the scanner asserts RTS
prior to any data transmission, regardless of the state of CTS. The scanner
waits up to Host Serial Response Time-out for CTS to be asserted. If CTS
is not asserted during this time, the scanner issues an error indication and
discards the data. The scanner de-asserts RTS when transmission is
complete.
RTS/CTS Option 3
ACK/NAK: When this option is selected, after transmitting data, the scanner
expects either an ACK or NAK response from the host. When a NAK is
received, the scanner transmits the same data again and waits for either an
ACK or NAK. After three unsuccessful attempts to send data when NCK are
received, the scanner issues an error indication and discards the data.
ACK/NCK
ENQ: When this option is selected, the scanner waits for an ENQ character
from the host before transmitting data. If an ENQ is not received within the
Host Serial Response Time-out, the scanner issues an error indication and

15
discards the data. The host must transmit an ENQ character at least every
Host Serial Response Time-out to prevent transmission errors.
ENQ
ACK/NAK with ENQ: This combines the two previous options. For
re-transmissions of data, due to a NAK from the host, an additional ENQ is
not required. ACK/NCK with ENQ
XON/XOFF: An XOFF character turns the scanner transmission off until
the scanner receives an XON character. There are two situations for
XON/XOFF:
;2))LVUHFHLYHGEHIRUHWKHVFDQQHUKDVGDWDWRVHQG:KHQWKHVFDQQHU
has data to send, it waits up to Host Serial Response Time-out for an XON
character before transmission. If the XON is not received within this time,
the scanner issues an error indication and discards the data.
;2))LVUHFHLYHGGXULQJDWUDQVPLVVLRQ'DWDWUDQVPLVVLRQWKHQVWRSVDIWHU
sending the current byte. When the scanner receives an XON character, it
sends the rest of the data message. The scanner waits up to 30 seconds for
the XON
XON/XOFF

16
RTS Line State
Host: Low RTS ˄Default˅
Host: High RTS &RH
Host Serial Response Time-out
2 sec˄Default˅5sec
7.5 sec 10 sec
Data Bits
7-Bit 8-Bit*˄Default˅
Stop Bit Select
1 Stop Bit˄Default˅2StopBit

17
Parity None*˄Default˅
Odd
Even
Select Mark parity and the parity bit is always 1.
Mart
Select Space parity and the parity bit is always 0.
Space
Global Settings
Element amendment
Enable Element amendment *
Disable Element amendment

18
Printable character Output only
Enable
Disable*
Decoder optimization
Enable Decoder optimization *
Disable Decoder optimization
Save Power
Enable*
Disable

19
Standby duration
2 second
5 second *
10 second
20 second
Double confirm
Disable Double confirm* 5 Times

20
2Times 10Times
Same barcode delay time
If a barcode has been scanned and output once successfully, the laser beam
must be off or moved away from the barcode beyond delay time to active
VFDQQLQJWKHVDPHEDUFRGH:KHQWKLVIHDWXUHLVVHWWREH³[))´WKHQWKH
delay time is indefinite.
Same barcode delay time˄2 Digits;00~99;00*˅
Global Max./Min. code length
Global Max. code length˄2 Digits;00~99;99*)
Global Min. code length˄2 Digits;00~99;XX*)
Table of contents