Feelgood mr. steam AromaSteam MS AROMA Instruction manual

mr
.steam®Feel Good Inc.®
____________________
IMPORTANT:
Leave this material with the homeowner.
____________________
Installation, Operation and Maintenance Manual
Steambath Generator Systems
Residential
Models: MX4E-6E
mr
.steam® lFeel Good Inc.
®
Installation, Operation & Maintenance Manual
AromaSteam
Fragrance Metering
Pump for
Residential and Day Spa Steam Rooms
Part Number MS AROMA (104496)
__________________________________
IMPORTANT: Leave this material with the home owner.
__________________________________

2
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
PUR103938 REV 1.23
BEFORE INSTALLING
Carefully inspect the AromaSteam and packaging for shipping
damage. In the event of shipping damage, please contact the
carrier for claim information. Our customer service department can
assist you with product replacement.
Read these instructions before installation or service. Although the
AromaSteam has been fully qualified for shipment by MrSteam, the
following must be reviewed for proper, safe and enjoyable steam
bathing:
1.Verify that the model and accessories specifications are correct for
the application.
2.The physical size of the unit, clearance for plumbing servicing, its
distance from the steam room and fragrance location must all be
considered before final installation.
3.Consider any controls and accessories before initiating
installation. Read the Installation and Operation Manual of all
controls and accessories available at www.mrsteam.com technical
downloads.
IMPORTANT NOTES:
This document contains important safety, operation and
maintenance information. After installation leave this document with
the homeowner. Do not discard this document.
The information in this manual should be used in conjunction with
consultations with an architect, designer and contractor in
determining factors necessary in providing a suitable and safe steam
room. The MrSteam AromaSteam is intended to be operated with
MrSteam iSteam®, AirTempo®or iTempoPlus®controls only. The
controls are to be installed strictly in accordance with the specific
manuals provided with the controls or accessories.
TABLE OF CONTENTS
Installer's Section:
Box Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Important Safety Information . . . . . . . . . . . . . . . .4
Warning Sticker . . . . . . . . . . . . . . . . . . . . . . . . . . .5
AromaSteam Overview . . . . . . . . . . . . . . . . . . . . .6
General System Dimensions . . . . . . . . . . . . . . . . .7
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . .15
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . .16
Homeowner's Section
Fragrances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Important Safety Information . . . . . . . . . . . . . . .18
Locating the AromaSteam . . . . . . . . . . . . . . . . .19
AromaSteam Operation . . . . . . . . . . . . . . . .19-20
This room is equipped with a fragrance dispensing system.
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
mr.steam®
43-20 34th Street, Long Island City NY 111011-800-76 STEAM
www.mrsteam.com
IMPORTANT NOTES:
This “peel and stick”
warning label shall be
posted in a conspicuous
location next to the steam
room door.

INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
All Drawings for Illustrative
Purposes Only
mr
.steam®Feel Good Inc.®
Installation, Operation and Maintenance Manual
Linear Steam Head
Residential Models:
144080
____________________
MP
_
O
_
RT
_
AN
_
T:_
Le
_
ave
_
th
_
is
_
ma
_
teri
_
al
_
wit
_
h
t
_
he
_
ho
_
me
_
ow
_
ner
_
.
IMPORTANT:Leave this material with the homeowner.
AromaSteam
Fragrance Metering Pump System for
Residential and Day Spa Steam Rooms
Part Number MS AROMA(120V)
Thisinstallation, operation and maintenance manual is forgeneral reference.
The installation,operation and maintenance manual supplied with the product must be used for
installation,operation and maintenance purposes. Failure to use the installation, operation and
maintenance manual supplied mayresult in a property damage or personal injur y.
Installation &
Operation Manual
with peel and stick
Warning label
Power Adapter
AromaSteam Pump
Box Contents
Additional Items included
but not shown:
4x Mounting Screws and
Anchors for Aromasteam
14 5
/8"
5 5
/16"
45
/16"
Dimensions
3

• Keep the AromaSteam and fragrance away from heat,
sparks, electrical outlets, open flames such as candles
and hot surfaces.
• No smoking.
• Keep Out of the Reach of Children.
• Use only non-sparking tools. Take precautionary
measures against static discharge.
• Contains denatured ethyl alcohol
• In case of fire: Use CO2, dry chemical, alcohol foam,
and water spray for extinction.
• Always store the MrSteam Aroma fragrances
in a secure location. Keep container tightly
closed and store in a cool, dry and well-ventilated
place.
•Avoid fragrance contact with eyes. May cause mild eye
irritation. Ingestion may cause irritation, nausea, vomiting.
• Fragrance vapors may cause drowsiness, allergic reac-
tions, difficulty breathing or skin irritation. If condition
persists get medical attention.
•The Fragrance Safety Data Sheet provides comprehensive
information about MrSteam Aroma fragrances. Contact 1-
800-767-8326 or go online at www.mrsteam. com for a
copy of the Safety Data Sheet.
• MrSteam fragrances (MS-OIL1 through MS-OIL5) are
only for use with the MrSteam AromaSteam. Never use
MrSteam fragrances in any other pump, spray or dis-
pensing device. The use of MrSteam fragrances in any
other device may cause personal injury.
• The use of any fragrances other than MrSteam
fragrances with a MrSteam AromaSteam may introduce
excessive concentration of fragrances into the steam
room, resulting in personal injury.
• Keep out of the reach of children.
•Always install the supplied Check Valve. Failure to
install the Check Valve may result in excessive fragrance
delivery into the steam room and cause
dizziness and/or personal injury.
• The AromaSteam has been factory set to deliver a
suitable amount of fragrance into a typical sized
residential or Day Spa steam room. Start with the
AromaSteam volume at a very low setting. Gradually
increase the volume setting until a comfortable
fragrance level is reached. Do not exceed the
“Recommended Setting” indicated on the
AromaSteam volume.
• Do Not alter or modify any MrSteam product. Doing so
may result in a personal injury.
• Discontinue use of the steam generator and control if
the steam generator or control are damaged or
otherwise not functioning properly. Doing so may result
in an inoperative or hazardous installation
•ELECTRICAL SHOCK HAZARD. The AromaSteam
pump is connected to 120V or 240V line voltage and
contains live electrical components. All installation and
service to be performed by qualified and licensed
electricians and plumbers only. Installation or service by
unqualified persons or failure to use MrSteam parts
may result in property damage, a hazardous condition
or an electrical shock hazard.
•Install according to Local and National plumbing and
electrical codes.
4
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
IMPORTANT NOTE: As you follow these instructions, you will notice warning and caution symbols. This blocked
information is important for the safe and efficient installation and use of fragrance and AromaSteam. These are types of
potential hazards that may occur during installation and operation:
Signals a Hazard that may cause serious injury or death if precautions are not followed.
Signals a hazard that may cause minor injury or product damage if precautions are not followed.
IMPORTANT NOTE: This highlights information that is especially relevant to a problem-free installation.
All information in these instructions is based on the latest product information available at the time of publication. MrSteam
reserves the right to make changes at any time without notice.

5
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
Warning Sticker
The "peel & stick" warning label ( supplied on page 2 ) shall be
posted in a conspicuous location next to the steam room door.
This room is equipped with a fragrance dispensing system.
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
mr.steam®
43-20 34th Street, Long Island City NY 111011-800-76 STEAM
www.mrsteam.com
• MrSteam Aroma fragrances are only for use in residential and day spa installations. Do Not use MrSteam Aroma
fragrances in commercial installations.
•Not for use in acrylic or fiberglass rooms. Check with the room manufacturer to determine compatibility of these
fragrances with room construction materials.
•Do Not alter or modify any MrSteam product. Doing so will void the warranty.
• MrSteam Aroma fragrances must be disposed of as hazardous waste.
1.Keep the AromaSteam away from heat, sparks, electrical outlets, open flames such as candles and hot surfaces.
2.Locate the Fragrance and AromaSteam to monitor the consumption of fragrance and for easy replacement.
3.The AromaSteam should not be installed in areas accessible to children. A locked room is strongly recommended
(i.e. utility room)
4.The AromaSteam is designed and intended for indoor use only and is to be located indoors in a dry clean location
and not subject to moisture, condensation or similar high humidity environments.
5.Do not install the AromaSteam outdoors.
6.Do not install the AromaSteam in a location where water could freeze.
7.Do not install the AromaSteam near corrosive materials and chemicals. Installation in areas having high concentra-
tions of chlorine (such as pool equipment room) should be avoided.
8.Attach the AromaSteam onto a secure vertical surface.
9.Use only non-sparking tools. Take precautionary measures against static discharge.
Important Notes
IN CASE OF EYE CONTACT: Rinse the eyes
immediately with plenty of water, also under
the eyelids, for at least 15 minutes. If eye
irritation persists: Get medical attention.
IN CASE OF SKIN CONTACT: Remove/Take off
immediately all contaminated clothing. Rinse
skin with soap and water or shower. If skin
irritation persists, get medical attention.
IF SWALLOWED: Do not induce vomiting. Rinse
mouth thoroughly with water. If conscious,
give large amounts of water. If symptoms
persist, call a physician.
First Aid

6
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
AromaSteam Overview
AromaSteam Pump
AromaSteam Transformer
120VAC/240VAC
Typical MrSteam
Steam Generator
(shown with cover removed)
Steam Generator
Printed Circuit Board
Request Cable
Pressure
Hose
Steam
Head
Steam
Line 90˚T
Check
Valve
Receptacle
required

7
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
:%8*0.> 06'>
4)3.%'>
0.8*/'3>
'2;'78> "$-'> >#>
0> 9'> '/'3804>
8'> '&>
.6*&'> 0(> 8'> 005> 9'> *1'> >
3'66;4'>
06'>
8'> '.'3803>
Steam Head
(Inside of Steam Room)
Check Valve
Pressure
Hose 6ft.
Steam Generator
Steam Pipe90° T
Suction Hose
AromaSteam Transformer
120VAC/240VAC
4 1/2ft (To Outlet)
Request Cable 6ft.
(To Steam Generator)
AromaSteam Pump
5 - 10ft. Optimal
Fragrance
Container
AromaSteam Pump Specs
Dimensions: 4.3”W x 14.8”H x 5.4”D
Weight: 5 pounds
Supply Voltage: 120VAC/240VAC, 50/60 Hz
Max Current Draw: 0.1 Amps
General System Dimensions
®
AROMASTEAM

Diagram 3 Diagram 4
Diagram 1 Diagram 2
Installing the AromaSteam
Locating the AromaSteam:
1. Place in a location that allows visual monitoring of the fragrances
level.
2. Place in a location that allows for easy replacement of the
fragrance container.
3. Locate the AromaSteam within 6' of the steam generator as
required to route the request cable in a safe and secure
manner. See the system dimensions on page 7.
4. Locate the AromaSteam within 4' of a grounded outlet as
required to route the electrical cord in a safe and secure
manner. See the system dimensions on page 7.
5. Locate the AromaSteam within 6' of the steam supply line as
required to route the pressure hose in a safe and secure
manner. See the system dimensions on page 7.
6. Do not install in an unheated location where water could
freeze.
7. Locate in a area where the ambient temperature does not
exceed 88oF.
8
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
Tools required:
•Cordless drill with a Phillips bit
• Level
Use only non-sparking tools. Take precautionary measures
against static discharge
Mounting the AromaSteam on a Wall
1. Pre-drill as required and install the two screws provided.
They must be 2 -1/2" inches apart and level as required to
securely mount the AromaSteam keyhole slots. Use Drill
Template on following page if necessary.
2. Use a level to make sure the screws are level.
3. Mount the AromaSteam keyholes onto the screws. Tighten
screws as required to firmly secure the AromaSteam.
4. Use the two mounting screw provided to secure the
AromaSteam using the two mounting hole at the middle of
the AromaSteam (Diagram 3).
5. Use anchors or other hardware as required for secure
mounting. Test the AromaSteam for secure mounting.
Keyhole
slots
Back of Pump
Mounting
Holes
611/16"
21
/2"

21
2"
611
16 "
13
8"
9
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
Drill Template
IMPORTANT NOTE: Do no scale template.
Template must be printed at 1:1 scale.
WARNING:
Failure to print template at 1:1 scale will result in
wrong mounting hole locations.

Installing the 90 degree T
For optimal results locate a brass 90 degree T (not
provided) in the steam supply line within 5-10 feet of
the steam head. If using copper tubing for steam lines,
install a female 1/2 NPT Tee in the steam line facing
upward.
IMPORTANT NOTE: Follow the installation
instructions for the steam pipeline in the MrSteam
Steam Bath Installation and Operation Manual. Visit
www.mrsteam.com to download this document.
Install Check Valve into 90° T/adaptor.
Failure to install the supplied Check Valve may result in
excessive fragrance delivery into the steam room and
cause dizziness and/or personal injury.
The supplied Check Valve prevents excessive amounts
of fragrance from entering the steam line and steam
room. Never install the AromaSteam without the
supplied Check Valve.
10
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
Pressure Hose
AromaSteam
Pump
Check Valve
Steam Pipe (not supplied)
90o T(not supplied)
All Drawings for Illustrative Purposes Only

Installation of the fragrance container
1.Locate the container cap with the hole that is included with the bottle of fragrance. Replace the fragrance
container cap with the cap with the hole. Hand tighten only.
2.Insert the suction hose through the hole in the container cap.
3.Place the fragrance container into AromaSteam’s open cavity, ensure both bottom corner of the fragrance
container are seated in rectangular openings on the bottom of the AromaSteam.
4. Insert the fragrance container with its label facing outward, so it is visible at all times. This label contains
important information (Bottom Diagram).
IMPORTANT NOTE: To prevent damage, do not use tools to tighten the container cap.
11
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only
AromaSteam
Pump
Fragrance Container
Cap with Hole
Fragrance Container
securely seated in the
Aroma Steam Pump
Suction Hose

Electrical Connection of AromaSteam
IMPORTANT NOTE: AromaSteam is for use with AirTempo®iSteam®and iTempoPlus®controls only.
1.Disconnect all power to the MrSteam steam generator.
Failure to disconnect power may result in an electrocution hazard.
2.Remove the top cover.
3.Run the request cable from the AromaSteam through one of the knock outs in the side of the steam bath
generator. Use a strain relief bushing or grommet to prevent chafing.
4.Locate the two quick connect tabs labeled “AROMA” on the printed circuit board in the location shown.
5.Connect the request cable to the terminals. The terminals are not polarized.
6.Connect AromaSteam’s transformer into a 120VAC/240VAC wall outlet.
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
AromaSteam Connections
Steam Generator
Circuit Board
AromaSteam Pump
AromaSteam Transformer
120VAC/240VAC
Typical MrSteam
Steam Generator
(shown with cover removed)
Request
Cable
AromaSteam Connections
Steam Generator
Circuit Board
12
All Drawings for Illustrative Purposes Only
Receptacle
Required

Priming the AromaSteam
1.Ensure MrSteam fragrance container is full
2.Press and hold the priming button until liquid fills the suction hose all the way to pump head in
AromaSteam.
3.Liquid will automatically enter pressure hose when pump is activated from steam room control. It might take
multiple steam sessions to reach steam head, based on length of pressure hose and location of 900T.
IMPORTANT NOTE: If liquid is not filling tubing in AromaSteam head, release priming button and check if
suction hose is securely installed onto barb fitting below AromaSteam head and check valve.
IMPORTANT NOTE: If an extended pressure hose is needed, please contact MrSteam Technical Service.
13
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
Steam Head
(Inside Steam Room)
Check Valve
Pressure
Hose 6ft.
Steam Generator
Steam Pipe90° T
Fragrance
Container
Suction Hose
AromaSteam Pump
Priming Button
Pump Head
®
AROMASTEAM

The AromaSteam has been factory set to deliver a suitable
amount of aromatic fragrance into a typical sized steam
room. Do not exceed the maximum setting. Please contact
the MrSteam Technical Service Department before changing
this setting.
Contact the MrSteam Technical Service Dept. at (800) 76-
STEAM (West Coast) or (800) 72-STEAM (East Coast) for
assistance or additional information.
Increasing the settings may introduce excessive
concentration of fragrance into the steam room, resulting in a
health hazard.
Activating the AromaSteam from a
AirTempo®Control
1.Press the ON/OFF button to turn the steam
generator ON.
2.Press the AromaSteam button, AROMA will be displayed
on the screen when AromaSteam is on.
3.Aroma fragrance will automatically be pumped into the
steam line at preset intervals.
Activating the AromaSteam from an iSteamX®Control
1.Press the START button to turn the steam generator on.
2.In the dashboard press the AromaSteam icon (flower) on
the left, then press the On Button to start or Off button to
stop.
3.Aroma fragrance will automatically be pumped into the
steam line at preset intervals.
Activating the AromaSteam from iTempo/Plus®Control
1.Press the ON/OFF button to turn the steam generator ON.
2.Press the AromaSteam button, AROMA will be displayed
on the screen when AromaSteam is on.
3.Aroma fragrance will automatically be pumped into the
steam line at preset intervals.
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
AromaSteam
Button
chroma
timetemp
aroma
AromaSteam
Button
14
Fragrance Volume Scale
Fragrance Volume Indicator
Volume Adjustment Knob
LED Light
AromaSteam
Button
Adjusting the Amount of Fragrance Delivery
®
AROMASTEAM

Troubleshooting
TO AVOID ELECTRIC SHOCK, DISCONNECT POWER TO AROMASTEAM BEFORE SERVICING
AromaSteam does not prime
1.Check if correct voltage is available.
2.Check liquid level in fragrance container. Replenish liquid, if necessary.
3.Check for air bubbles in the suction hose or the AromaSteam head. To eliminate air bubbles see: Priming
AromaSteam.
4.Check valves for contamination. Clean valve with compressed air if necessary.
AROMASTEAM DOES NOT INJECT FRAGRANCE INTO STEAM ROOM
1.Check if voltage is available.
2.Check liquid level in fragrance container. Replenish fragrance if necessary.
3.Check for air bubbles in the suction hose or the AromaSteam head. To eliminate air bubbles see: Priming
AromaSteam. See page 13.
4.Check valves for contamination. Clean valves if necessary.
5.Check fragrance container for contamination.
6.Check the pressure hose for kinking or jamming. Straighten or replace.
7.Check if fragrance is freely flowing through the Check Valve when the AromaSteam is energized. Apply
compressed air through the Check Valve. Attach the compressed air at the point of connection of the
pressure hose.
8.Ensure the AromaSteam has been powered up.
AromaSteam fragrance delivery too much or too little
The AromaSteam has been factory set to deliver a suitable amount of aromatic fragrance into a typical sized
steam room. Please contact the MrSteam Technical Service Department before changing this setting. See page 13
for instructions on adjusting the amount of fragrance delivery.
Contact the MrSteam Technical Service Dept. at (800) 76-STEAM {East coast) or (800) 72-STEAM
(West Coast) for assistance or additional information.
Electrical Shock Hazard
MrSteam AromaSteam’s are connected to 120V/240V line voltage and contain live electrical components. All
installation and service to be performed by qualified and licensed electricians and plumbers only. Installation or
service by unqualified persons or failure to use MrSteam parts may result in property damage or in a hazardous
condition.
15
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®

Check Valve
104240
Tube (per foot)
104255
Pump Line Cord 120VAC
104494
Tube (per foot)
104255
Pump Head
104492
INSTALLER SECTION
AromaSteam Operation and Installation Instructions
®
Pump head
104492
Check Valve
104493 (5 pcs.)
Pressure hose (per foot)
104255
Suction Hose (per foot)
104255
AromaSteam Transformer
120VAC/240VAC,
104494
Replacement Parts
This AromaSteam is factory wired. If the power cord of the AromaSteam is damaged it must be replaced by the
MrSteam service department or similarly qualified personnel in order to avoid an electric shock hazard. All electrical
connections to be made by a licensed, qualified electrician. Disconnect all power to the steam generator before
making power connections.
All items listed below are field serviceable.
16
®
AROMASTEAM

17
HOMEOWNER SECTION
AromaSteam Operation and Installation Instructions
®
The AromaSteam’s state-of-the-art AromaSteam introduces
fragrance into the steam pipe and into your steam shower.
MrSteam Aroma is Available in These Five Fragrances:
FRAGRANCE PART NO. CONTAINER VOLUME.
Eucalyptus (MS-OIL1) 1 liter /33 fl.oz ..
A deeply refreshing aroma with cleansing effects, eucalyptus may help open air
passageways.
Lavender (MS-OIL2) 1 liter /33 fl.oz.
A sweet, lightly floral scent, lavender may help soothe anxiety with its calming &
restorative properties.
Evergreen (MS-OIL3) 1 liter /33 fl.oz.
A refreshing blend of spruce, fir and pine reminiscent of a forest on a crisp morning.
Energizing Mint (MS-OIL4) 1 liter /33 fl.oz.
A blend of mint, citrus and herbs that may stimulate and energize.
Breathe (MS-OIL5) 1 liter /33 fl.oz.
A tropical combination that may help clear chest, nose and sinuses.
The Safety Data Sheet provides comprehensive information about MrSteam Aroma
fragrances. Contact 1-800-767-8326 or go online at www.mrsteam.com for a copy of the
Safety Data Sheet.
MrSteam Aroma
Fragrances (MS OIL 1-5)
READ ME FIRST!
Warning..... As you follow these instructions, you will notice warning and caution symbols. This blocked
information is important for the safe and efficient installation and operation of this generator. These are types of
potential hazards that may occur during installation and operation:
Warning..... Indicates a potentially hazardous situation, which, if not avoided, could result in death or
serious injury.
Caution...... Indicates a potentially hazardous situation, which, if not avoided may result in minor or
moderate injury or product damage.
IMPORTANT NOTE: This highlights information that is especially relevant to a problem-free installation.
All information in these instructions is based on the latest product information available at the time of publication.
Mr.Steam reserves the right to make changes at any time without notice.

18
HOMEOWNER SECTION
AromaSteam Operation and Installation Instructions
®
•Keep away from heat, sparks, open flames, & hot surfaces
• No smoking
•Keep container tightly closed
• Ground/bond container and receiving equipment
• Use only non-sparking tools
•Take precautionary measures against static discharge
• Use explosion-proof equipment
•Wear protective gloves, protective clothing, eye
protection or face protection
•Store in a well-ventilated place
• Keep cool
• Dispose of contents and container at an approved
waste disposal plant
•To prevent spillage always use with the caddy provided
with the pump
• Keep away from children
First Aid
In case of Eye Contact
Rinse immediately with plenty of water, also under the
eyelids, for at least 15 minutes. If eye irritation persists:
Get medical advice/attention.
In case of Skin Contact
Remove/Take off immediately all contaminated clothing. Rinse
skin with water/shower. If skin irritation persists, call a physician.
In case of Inhalation
Remove exposed individual(s) to fresh air for 20 minutes.
Consult a physician/poison center if individual's condition
declines or if symptoms persist.
In case of Ingestion
Rinse mouth thoroughly with water. Do NOT induce
vomiting. If conscious give large amounts of water. If
symptoms persist, call a physician.
Important Notes:
•Not for use in acrylic or fiberglass rooms. Check with the room manufacturer to determine compatibility of these
fragrances with room construction materials.
•Do Not alter or modify any MrSteam product. Doing so will void the warranty.
• MrSteam Aroma fragrances must be disposed of as hazardous waste.
• Avoid fragrance contact with eyes. May cause mild eye
irritation. Ingestion may cause irritation, nausea,
vomiting.
• Fragrance vapors may cause drowsiness, allergic
reactions, difficulty breathing or skin irritation. If
condition persists get medical attention.
• The Fragrance Safety Data Sheet provides
comprehensive information about MrSteam Aroma
fragrances. Contact 1-800-767-8326 or go online at
www.mrsteam. com for a copy of the Safety Data Sheet.
• MrSteam fragrances (MS OIL 1-5) are only for use with
the MrSteam AromaSteam (part number MS AROMA
and MS AROMAC). Never use MrSteam fragrances in
any other AromaSteam, spray or dispensing device.
The use of MrSteam fragrances in any other device may
cause personal injury.
•The use of any fragrances other than MrSteam
fragrances with a MrSteam AromaSteam may introduce
excessive concentration of fragrances into the steam
room, resulting in personal injury.
• Keep out of the reach of children.
• The AromaSteam has been factory set to deliver a
suitable amount of fragrance into a typical sized
residential or Day Spa steam room. Start with the
AromaSteam volume at a very low setting. Gradually
increase the volume setting until a comfortable
fragrance level is reached. Do not exceed the
“Recommended Setting” indicated on the
AromaSteam volume.
• Do Not alter or modify any MrSteam product. Doing so
may result in a personal injury.
FLAMMABLE LIQUID AND VAPOR
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS

OPERATION
Powering Up the AromaSteam
IMPORTANT NOTE: This step only needs to be
performed during installation.
1.The AromaSteam needs to be connected to a
power source before it can be used.
2.LED light on pump's power block will illuminate when
pump is connected to a power source.
3. LED light on pump will illuminate when steam
generator sends signal to pump.
4. Adjust fragrance volume to desired level by rotating Volume
Adjustment Knob.
19
HOMEOWNER SECTION
AromaSteam Operation and Installation Instructions
®
Locating the AromaSteam/Fragrance:
1.Place in a location that allows visual monitoring of the fragrances level.
2.The AromaSteam should not be installed in areas accessible to children. A
locked room is strongly recommended (ie: utility room).
3.The AromaSteam is designed and intended for indoor use only. Do not
install outdoors.
4.Do not install in an unheated location where water could freeze.
5.Locate in a area where the ambient temperature does not exceed 88oF.
Using a fragrance container that is not secured in the
AromaSteam, or using a AromaSteam that is not mounted may result in
spillage, excessively strong vapors or a fire hazard.
6.Insert the fragrance container with the label facing outward so it is visible
through the AromaSteam. The label contains important information.
7.Always keep the container in the AromaSteam while it is connected to the
dispensing AromaSteam.
Fragrance Volume Scale
Fragrance Volume Indicator
Volume Adjustment Knob
LED Light
Adjusting the Amount of Fragrance
The AromaSteam has been factory set to deliver a suitable
amount of fragrance into a typical sized steam room.
Do not exceed the maximum setting. Please contact the
MrSteam Technical Service Department before changing
this setting.
Contact the MrSteam Technical Service Dept. at
(800) 76-STEAM (East coast) or (800) 72-STEAM
(West Coast) for assistance or additional information.
Increasing the settings may introduce excessive concentration
of fragrance into the steam room, resulting in a health hazard.
Fragrance Volume Scale
Fragrance Volume Indicator
Volume Adjustment Knob
LED Light
®
AROMASTEAM
®
AROMASTEAM

HOMEOWNER SECTION
AromaSteam Operation and Installation Instructions
®
iTempoPlus®Control
1.Press the ON/OFF button to turn the steam generator ON.
2.Press the AromaSteam button, AROMA will be displayed on
the screen when AromaSteam is on.
3.Aroma fragrance will automatically be pumped into the steam
line at preset intervals.
iSteamX®Control
1.Press the START button to turn the steam generator on.
2.In the dashboard press the AromaSteam button, the
button will be highlighted when AromaSteam is on.
3.Aroma fragrance will automatically be pumped into the
steam line at preset intervals.
Activating the AromaSteam from a Control Air Tempo®Control
1.Press the ON/OFF button to turn the steam generator ON.
2.Press the AromaSteam button, AROMA will be displayed on the
screen when AromaSteam is on.
3.Aroma fragrance will automatically be pumped into the steam line at
preset intervals.
AromaSteam
Button
chroma
timetemp
aroma
AromaSteam
Button
OPERATION (cont.)
mr
.steam
®
Feel Good Inc.®
PUR103938 REV 2.22
2023 © Mr.Steam and des., AirTempo, AromaFlo, AutoFlush, AutoSteam, AudioWizard, Butler Package, ChromaSteam, Clean Steam...Every Time, Club
Therapy, Digital 1, Express Steam, From Bathroom to Spa, HomeWizard, iButler, iTempo, iTempo/Plus, iGenie, iSizing, iSteam, Linear Steamhead, Making
Wellness a Way of Life, MusicTherapy, SmartSizing, Spa Package, Steam Genie, Steam@Home, SteamStart, SteamTherapy, Tala, Tala Bath & Body Therapy
The Intelligent Steambath, Valet Package, and Virtual Spa System are registered trademarks of Mr.Steam.
43-20 34th Street, Long Island City, NY 11101 1.800.76.STEAM • 9410 S. La Cienega Blvd. Inglewood CA 90301 1.800.72.STEAM
www.mrsteam.com
Products, information and specifications are subject to change without notice. For more information call
Sales & Support at 1.800.767.8326 (East Coast) or 1.800.727.8326 (West Coast) for more information.
mr
.steam
®
PUR103938 REV 1.23
AromaSteam
Button
This manual suits for next models
1
Table of contents
Popular Water Pump manuals by other brands

TOHATSU
TOHATSU VE1500A-Ti installation manual

Bruin Pumps
Bruin Pumps BR4300 Maintenance and Inspection

AMT
AMT 4946-99 Specifications information and repair parts manual

Samoa
Samoa 402000 Parts and technical service guide

ARO
ARO ARO 670074 Operator's manual

Clarke
Clarke DW75 Operation & maintenance instructions

Wilo
Wilo CronoLine-IL-E Installation and operating instructions

Clarke
Clarke CEB103 Operation & maintenance instructions

Wesco
Wesco 272397 Operating instructions and parts manual

SPX FLOW
SPX FLOW Johnson Pump CombiProLine OH3 instruction manual

Silvercrest
Silvercrest SGP 230 A1 Translation of the original instructions for use

Astral Pool
Astral Pool COLUMBIA Manua