
Models FR-14030, FR 14036, FR 14042, and FR 14048 are tested
and listed by PFS Corporation, Cottage Grove, WI, USA, Report No.
08-155. The 14000 Series models are top-vented, gas only fireplaces
that are listed for use only with the FIRE-LOG Gas Log appliance as
manufactured by Heatmaster, Inc. These gas appliances come with a
gas control valve that includes an automatic shut-off switch. The gas
valve has a standing pilot light assembly which is available as either
a standard safety pilot or a millivolt remote control pilot assembly.
The exhaust flue gases are to be vented through the top of the unit
with B-Vent piping. A ten inch (10”) diameter, double wall B-
Venting system and a listed vent cap are not supplied but are required
for proper operation of all FireRock 14000 Series fireplaces. See
venting instructions on pages 19 - 21.
WARNING: This gas appliance must not be connected to a chimney
flue servicing a solid fuel burning appliance.
Intended Use Statement:
The 14000 Series is intended to burn propane (LP) gas or natural gas,
only. This appliance is not intended to be used as a primary source of
heat. The 14000 Series and its approved components are safe when
installed according to this installation manual and when operated as
recommended by the manufacturer. Unless you use Fire Rock
Products, L.L.C. approved components tested for this appliance you
may cause a fire hazard or serious injury.
Before you begin the installation of this appliance read these
instructions completely.
Fire Rock Products, L.L.C. disclaims any responsibility for the
following actions:
1. Modification of the appliance or any of its components.
2. Use of any component part not approved by Fire Rock
Products, L.L.C. in combination with this appliance.
3. Installation or operation in a manner other than instructed
in this manual.
4. Burning of anything other than the listed gas log unit and
the type of gas approved for use in this gas appliance.
Note(s): The most important areas of concern with the installation of
the top venting 14000 Series are clearance to combustible materials,
proper assembly of component parts, load carrying capacity of
underlying floor system, height of chimney system, hearth extensions
and the techniques employed in applying finishing materials to the
wall surrounding the 14000 Series fireplace. Each of these topics will
be covered in detail throughout this manual. Special attention must
be given to each topic as the installation progresses.
Theinstallationofthe14000Seriesfireplacemustconformwith
localcodesor,intheabsenceoflocalcodes,withthecurrent
NationalFuelGasCode,ANSI‐Z223.1/NFPA54orthecurrentNatural
GasandPropaneInstallationCode,CSAB149.1.
SAFETYINFORMATION
WARNING: This product contains or generates chemicals
known to the state of California to cause cancer or birth
defects or other reproductive harm.
Important: Read this owner’s manual carefully and com-
pletely before trying to assemble, operate or service this
WARNING: This product contains or generates chemicals
known to the state of California to cause cancer or birth
defects or other reproductive harm.
Important: Read this owner’s manual carefully and com-
pletely before trying to assemble, operate or service this
5. For propane (LP) use do not place propane supply
tank(s) inside any structure. Locate propane supply tank(s)
outdoors. To prevent performance problems, do not use
propane fuel tank of less than 100 lbs. capacity.
6. Do not install the 14000 Series fireplace in a mobile
home or recreational vehicle.