Flagro F-1000T Instruction Manual

OPERATING INSTRUCTIONS MANUAL
(Please retain for future reference)
For
F-1000T DUAL FUEL CONSTRUCTION HEATER
CERTIFIED FOR USE IN CANADA AND U.S.A.
As per Standard ANSI Z83.7 2000/
CSA 2.14 2000 Gas Fired Construction Heaters Unvented /Unattended Type.
FLAGRO INDUSTRIES LIMITED
ST. CATHARINES, ONTARIO
CANADA

- 2 -
GENERAL HAZARD WARNING:
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED
WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN,
ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL
SHOCK.
ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS
SHOULD USE OR SERVICE THIS HEATER.
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN
INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT THE MANUFACTURER.
WARNING:
FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID
COMBUSTIBLES, SUCH AS BUILDING MATERIALS, PAPER OR CARDBOARD, A
SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE
INSTRUCTIONS. NEVER USE THE HEATER IN SPACES WHICH DO OR MAY
CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH AS
GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN
CHEMICALS.
WARNING:
NOT FOR HOME OR RECREATIONAL VEHICLE USE.
WARNING:
INTENDED USE IS PRIMARILY THE TEMPORARY HEATING OF BUILDINGS
UNDER CONSTRUCTION, ALTERATION, REPAIR OR EMERGENCIES ONLY.
ALWAYS PROVIDE ADEQUATE VENTILATION. 1 SQ. IN. OF FRESH AIR MUST
BE SUPPLIED FOR EVERY 1000 BTUH OF HEAT.
THIS HEATER SHALL BE INSTALLED SUCH THAT IT IS NOT DIRECTLY
EXPOSED TO WATER SPRAY, RAIN AND/OR DRIPPING WATER.

- 3 -
This heater is designed and approved for use as a
construction heater under ANSI Z83.7 2000 and
CSA 2.14 2000 Gas Fired Construction Heaters
We cannot anticipate every use which may be made
of our heaters. CHECK WITH YOU LOCAL FIRE
SAFETY AUTHORITY IF YOU HAVE QUESTIONS
ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat
producing products in specific applications. Your local
authority can advise you about these.
SPECIFICATIONS
Model ……………………………………………………. F-1000T
Input ……………………………………………………... 1,000,000 btuh
Fuel ……………………………………………………….. Natural Gas or Propane
Inlet Pressure …………………………………………….. Natural Gas: 7.0” W.C.
…………………………………………………
…...
Propane: 11” W.C.
Ignition …………………………………………………….. Direct Spark Ignition
.…………………………………………...….. Thermostat Control
Air Circulation …………………………………………….. 7000 cfm
Fuel Consumption ……………………………………...... 46 lbs/hr
……………………………………………... 952 cfh
Approved ………………………………………………...... cULus listed

- 4 -
INSTALLATION:
The installation of this heater for use with natural gas shall conform with local codes or,
in the absence of codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54 and
the Natural Gas and Propane Installation Code, CSA B149.1.
The installation of this heater for use with propane tank or cylinder shall conform with
Local codes or, in the absence of local codes, with the Standard for the Storage and
Handling of Liquefied Petroleum Gases, ANSI/NFPA 58 and the Natural Gas and
Propane Installation Code, CSA B149.
This heater must be located at least 10ft (3m) from any propane gas cylinder. This
heater shall not be directed toward any propane gas container within 20ft (6m).
CLEARANCE TO COMBUSTIBLES:
F-1000T TOP: 4 ft FRONT: 16 ft SIDES: 2 ft REAR: 2 ft
CONNECTING THE CYLINDER:
If cylinders are used to supply the heater, no cylinders smaller than 100lb capacity shall
be used. These cylinders must supply a vapor withdrawal only.
1. All cylinder connections must be made using a wrench to tighten the POL fitting.
2. Be sure that the cylinder valve is in the closed position when connection
or disconnecting the cylinder.
3. A soap and water solution must be applied to all connections in order to leak
check the system.
The gas must be turned off at the propane supply cylinder(s) when the heater is not in
use. When the heater is to be stored indoors, the connection between the propane
supply cylinder(s) and the heater must be disconnected and the cylinders removed from
the heater and stored in accordance with Standard for the Storage and Handling or
Liquefied Petroleum Gases, ANSI/NFPA 58 and CSA B149.1, Natural Gas and Propane
Installation Code.
PIPING: This heater must be installed by a qualified gas technician following
local codes published by the authority having jurisdiction. Sizing of
supply piping must be determined using the length of pipe run as
well as total btuh rating of the appliance(s). Appropriate piping
tables must be used to determine size of supply piping dependant
on the length of run from source.

- 5 -
PRESSURES: MAXIMUM INLET PRESSURES: LP: 14.0 IN. WC.
NG:14.0IN.WC.
MINIMUM INLET PRESSURES: LP: 11.0 IN. WC.
NG:7.0IN.WC.
This heater must be supplied by pressures indicated on the
approval label. Over pressure may cause controls to fail.
DONOTsupply this unit with more than ½psig (14.0 in. W.C.)
Note: A second stage regulator must be installed if the supply
pressure exceeds ½psig.
FUEL: This heater will operate on propane or natural gas. The manifold
pressures are listed on the approval label. Ensure that the proper
pressure settings are achieved depending on the fuel being used.
A fuel selector valve is located on the manifold of the heater.
Ensure that this valve is in the proper position depending on the
fuel being used. DO NOT operate the heater with the valve in the
incorrect position.
HOSES: All hoses used to connect this heater of fuel supply must be Type 1
approved propane / natural gas hose assemblies.
ELECTRICAL: WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for
your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle.
120v supply must be available. Please note that the motor on this
unit requires 20 amps. Ensure appropriate gauge extension cord is
used.

- 6 -
MAINTENANCE:
1. Every construction heater should be inspected before each use, and at least
annually by a qualified service person.
2. The hose assembly shall be visually inspected prior to each use of the heater. If it is
evident there is excessive abrasion or wear, or the hose is cut, it must be replaced
prior to the heater being put into operation. The replacement hose assembly shall be
that specified by the manufacturer.
3. The appliance must be kept clear and free from combustible materials, gasoline and
other flammable vapors and liquids.
4. The flow of combustion and ventilation air must not be obstructed. Be sure to check
the fan assembly and ensure that the motor and blade are operating properly.
5. Compressed air should be used to keep components free of dust and dirt build up.
Note: Do not use the compressed air inside any piping or regulator components.

- 7 -
START UP INSTRUCTIONS:
1. Set fuel selector valve according to gas supply to be
used.
2. Connect construction heater to gas supply with
approved hose assembly.
3. Plug the electrical cord into a 20 amp supply.
4. Open all gas supply valves.
5. Depress the main switch to the “START” position.
The fan will start and the burner should ignite.
Release switch to “RUN” position.
6. Set the Thermostat to the desired temperature.
7. If heater fails to ignite after 3 attempts call your
supplier for service.

- 8 -
TO SHUT DOWN:
1. Close main gas supply valve while heater is
operating.
2. Move main switch to the “OFF” position.
3. Disconnect heater from gas supply.

- 9 -
F-1000T TROUBLESHOOTING ANALYSIS
PROBLEM POSSIBLE CAUSES REMEDY
Heater will not light
Air switch improperly set
- use centre adjusting screw to set air switch.
Turn clockwise to increase sensitivity, turn
counter clockwise to decrease sensitivity.
Blockage in copper inlet
tubes
- disconnect tubes from air switch. Use high
pressure air to clean any debris that may
block airflow.
Rearofheaterblocked-ensurerear of heater is unobstructed and
proper rear clearances are maintained (see
approval label)

- 10 -
Faultyswitch-replaceswitch
Gassupply-ensurerequired gas supply pressures are
supplied to the heater (see approval label)
Solenoid-ensuresolenoidisenergized(usevolt
meter)
- ensure plunger in solenoid is being
activated (use manometer at test point
after solenoid)
SparkPlug-ensuregapinspark plug is approx. 1/8”
- check spark plug wire connections
- ensure spark plug has good spark
- replace spark plug if necessary
IgnitionBoard-ensureelectrical signals for both spark
plug and solenoid are present (use volt
meter)
- ensure ignition board is properly
grounded

- 11 -
Thermostat-ensurethermostat is calling for heat
Heater will not remain lit after
start up
Faulty flamerod wire - check flamerod wire for any damage.
Replace if necessary.
Faultyflamerod-ensureconnectionsaresecure.
Replace flamerod if necessary.

- 12 -
Ignition board - check ground wire for proper
connection
- check polarity of extension cord
compared to polarity of plug on the
heater
- replace faulty ignition board
Thermostat-ensurethermostat is calling for heat
Electrical All components - before replacing any component, all
connections must be checked to ensure
electrical circuit is complete. (use volt
meter and enclosed wiring diagram).
- any point in the circuit where 120v is
not achieved indicates location of
problem and/or possible faulty
component.
Piping All pipe fittings - When loosened, tightened or
replaced, the complete fitting should be
removed and approved pipe dope
applied to all male threads before
reconnection.
- After a heater is serviced, the valve
train should be checked for leaks with a
soap and water solution or approved
leak detector solution.

- 13 -
PARTS LIST
F-1000T CONSTRUCTION HEATERS
S-1000 1 HP Motor
S-1001 Fan blade
S-1002 Regulator
S-1002FS S.S. Filter screen
S-1002T Modulating regulator hi/low fire
S-1003 Fuel selector valve
S-1003A Fuel shut-off valve
67871A Solenoid valve cover
S-1004 Solenoid valve
S-1005 Burner
S-406 Flame rod (S-1006)
S-1007 Flame rod wire
S-408A Long reach igniter (S-1008)
S-1009 Ignition wire
S-410 High temperature limit (S-1010)
S-411 Off-run-start switch (S-1011)
S-412 Main relay (S-1012)
S-414 Air proving switch (S-1014)
S-415A Ignition control-120V (Fenwal) old (S-1015)
S-415P Potted ignition control 120V (Fenwal 02)
S-416 Thermostat (S-1016)
S-1019 Screen assembly
S-1020A Clear indicator light
S-1020B Red indicator light
S-1020C Green indicator light
S-1021 Power cord including plug
S-1022 Rubber wheel - 8"
B42R1.25 1-1/4" Second Stage Regulator
S54180-20 1-1/4" x 15-ft Hose Assembly

- 14 -

- 15 -

F-1000T Parts List

F-1000T Parts List
1
2
3
4
5
3
4
6
7
3
3
8
9
10
11
10
11
12
4

F-1000T Parts List
14A
14C
16
17
18
19
20
21
22
23
24
17
14B

F-1000T Parts List
Item # Description P/N
111/4"x31/2"Nipple40-113G3.5
211/4"BMUnion40-104-20
311/4"x90BMStreetElbow40-116-20
411/4"x51/2"Nipple40-113G5.5
5FuelShutOffValveS-1003A
6FuelSelectorValveS-1003
711/4"x11"Nipple40-113G11
8PipeHangerS-1031
911/4"x41/2"Nipple40-113G4.5
10 Solenoid S-1004
11 1 1/4" x 2" Nipple 40-113G2
12 Regulator S-1002
14A Clear Light Indicator S-1020A
14B Red Light Indicator S-1020B
14C Green Light Indicator S-1020C
16 Off/ON Switch S-411
17 Power Cord including plug S-1021
18 Thermostat S-416
19 Main Relay S-412
20 Air proving switch S-414
21 Potted Ignitino control S-415P Hose & Regulator
22 Rubber Wheel 8" S-1022
23 1 HP Motor S-1000
24 Rear Filter Screen S-1002FS
25 Long reach Igniter S-1009
26 Flame Rod S-406
27 Fan Blade S-1001
28 Burner S-1005
29 1 1/4" x 15FT Hose Assembly S54180-20
30 1 1/4" Second Stage Reg. B42R1.25
25
26
27
28
29
30