5
CONTENTS
Warnings ......................................................................................................................................................................................................page 2
General notes for installers, maintenance technicians, and users .......................................................................................................... page 3
Rapid operating instructions......................................................................................................................................................................page 4
1. Instructions for the user..........................................................................................................................................................................page 7
1.1. Control panel......................................................................................................................................................................................................................................page 7
1.2. Interpreting BOILER STATUS from LCD DISPLAY INDICATIONS ........................................................................................................................................page 9
1.3. Enabling/disabling the “Comfort” function.............................................................................................................................................................................page 12
1.4. Selecting the operating mode.....................................................................................................................................................................................................page 13
1.5. Adjusting heating and DHW temperature ..............................................................................................................................................................................page 14
1.6. Timer setting.......................................................................................................................................................................................................................................page 15
1.7. "Day temperature" and "night temperature" setting...........................................................................................................................................................page 16
1.8. "Manual" programme setting.......................................................................................................................................................................................................page 17
1.9. "Automatic" programme setting.................................................................................................................................................................................................page 17
1.10. CH programme mode................................................................................................................................................................................................................... page 18
1.11. Parameters display......................................................................................................................................................................................................................... page 19
1.12. Failures that cannot be reset......................................................................................................................................................................................................page 20
1.13. Resuming boiler function............................................................................................................................................................................................................page 20
1.14. Boiler operation ..............................................................................................................................................................................................................................page 21
1.14.1. Switching on ...........................................................................................................................................................................................................................page 21
1.14.2. CH function ..............................................................................................................................................................................................................................page 21
1.14.3. DHW function..........................................................................................................................................................................................................................page 21
1.14.3.1. DHW integration through boiler burner................................................................................................................................................................ page 21
1.14.3.2. DHW production through solar plant..................................................................................................................................................................... page 22
1.14.4. Freeze protection function.................................................................................................................................................................................................page 22
1.14.4.1. Ambient probe freeze protection function ..........................................................................................................................................................page 22
1.14.4.2. Flow freeze protection function ...............................................................................................................................................................................page 22
1.14.4.3. Plate DHW freeze protection function ...................................................................................................................................................................page 22
1.14.4.4. Solar collector freeze protection function ............................................................................................................................................................ page 22
1.14.5. Pump and valve anti-shutdown function .....................................................................................................................................................................page 23
1.14.6. Collector heat transfer function........................................................................................................................................................................................page 23
1.14.7. Water heater cooling function...........................................................................................................................................................................................page 23
1.14.8. Solar mode operation and failure signal ....................................................................................................................................................................... page 23
1.14.9. Operation with (optional) external probe.....................................................................................................................................................................page 23
1.14.10. Operation with (optional) Remote Control ...............................................................................................................................................................page 23
1.15. Boiler shut-down ........................................................................................................................................................................................................................... page 24
1.15.1. Burner shut-down..................................................................................................................................................................................................................page 24
1.15.2. Shut-down due to incorrect air/ue gas system draught ....................................................................................................................................... page 24
1.15.3. Shut-down due to low water pressure...........................................................................................................................................................................page 24
1.15.4. Shut-down for fan malfunction ........................................................................................................................................................................................page 25
1.15.5. Alarm due to temperature probe malfunction ...........................................................................................................................................................page 25
1.15.6. Alarm due to (optional) Remote Control connection malfunction .....................................................................................................................page 25
1.16. Maintenance ...................................................................................................................................................................................................................................page 25
1.17. Notes for the user..........................................................................................................................................................................................................................page 25
2. Technical features and dimensions........................................................................................................................................................ page26
2.1. Technical features .............................................................................................................................................................................................................................page 26
2.2. Dimensions .........................................................................................................................................................................................................................................page 28
2.3. Key components...............................................................................................................................................................................................................................page 30
2.4. Boiler operating diagram...............................................................................................................................................................................................................page 32
2.5. Operating data...................................................................................................................................................................................................................................page 33
2.6. General characteristics....................................................................................................................................................................................................................page 33
2.7. CH circulation pump available head..........................................................................................................................................................................................page 34
2.8. Low and high temperature circulation pumps available head (V versions)................................................................................................................ page 35
2.9. Low and high temperature circulation pump available head (Z versions)..................................................................................................................page 35
2.10. Solar circulation pump available head................................................................................................................................................................................... page 36
3. Instructions for the installer ...................................................................................................................................................................page37
3.1. Installation standards...................................................................................................................................................................................................................... page 37
3.2. Installation........................................................................................................................................................................................................................................... page 37
3.2.1. Packaging ....................................................................................................................................................................................................................................page 37
3.2.2. Choosing where to install the boiler .................................................................................................................................................................................page 37
3.2.3. Installing the boiler.................................................................................................................................................................................................................. page 37
3.2.4. Boiler room ventilation...........................................................................................................................................................................................................page 38
3.2.5. Air intake and ue gas venting system.............................................................................................................................................................................page 38
3.2.5.1. Conguration of air intake and ue gas venting ducts: B23, B53, C13, C33, C43, C53, C83 .................................................................. page 39
3.2.5.2. Ø 100/60 mm and Ø 125/80 mm air/ue gas coaxial duct system.................................................................................................................page 40
3.2.5.3. Air intake and ue gas venting via 80 mm split pipes.........................................................................................................................................page 41
3.2.5.4. Air intake and ue gas venting via 60 mm split pipes.........................................................................................................................................page 41
3.2.6. Checking combustion eciency.........................................................................................................................................................................................page 42
3.2.6.1. Flue cleaning function.................................................................................................................................................................................................... page 42
3.2.6.2. Measurement procedure ...............................................................................................................................................................................................page 42
3.2.7. Connection to gas mains.......................................................................................................................................................................................................page 43
3.2.8. Hydraulic connections............................................................................................................................................................................................................ page 43
3.2.9. Solar collector probe installation........................................................................................................................................................................................page 44
3.2.10. Connection to electrical mains .........................................................................................................................................................................................page 44
3.2.11. Selecting the operating range in CH mode.................................................................................................................................................................. page 44
3.2.12. Connection to ambient thermostat (optional)............................................................................................................................................................ page 45
3.2.13. Connection to Open Therm Remote Control (optional)..........................................................................................................................................page 45
3.2.14. Connection to the (optional) external probe and sliding temperature operation ........................................................................................page 46
3.2.15. TSP parameters that can be set from interface and Remote Control..................................................................................................................page 48
3.3. Filling the system..............................................................................................................................................................................................................................page 50
3.3.1. Filling the CH system...............................................................................................................................................................................................................page 50
3.3.2. Filling the solar plant...............................................................................................................................................................................................................page 51
3.4. Starting up the boiler......................................................................................................................................................................................................................page 51