Four-Faith F-PLS User manual

F-PLS User Manual
Document Version
Pages
V1.0
Model:F-PLS
Total:22
F-PLS User Manual
Four-Faith Corporation
Add:11th Floor, A-06 Area, No.370, Chengyi Street, Jimei, Xiamen,
Fujian, China.
Tel:+86 17750019379 Fax: +86 592-5912735
Web: en.four-faith.net

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 2 of 22
Files Revised Record
Date
Version
Remark
Author
2019.2.25
V1.0

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 3 of 22
Copyright Notice
All materials or contents contained in this document are protected by copyright law and all
Copyrights are owned by Four-Faith company,except those contents quoted from other
parties.Without the written permission of Four-Faith company, no one shall copy, distribute,
duplicate, connect, transmit or use any content of this document in any way for any commercial
purpose, besides those are for non-commercial purposes and personal use(on the condition that the
content should not be modified, and shall retain the copyright and ownership information in the
material )
Trademark Notice
Four-Faith、四信、 、 、 are all registered trademarks of Xiamen
Four-Faith Communication Technology Co., Ltd., illegal use of the name of Four-Faith,
trademarks and other marks of Four-Faith is forbidden, unless written permission is authorized in
advance.

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 4 of 22

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 5 of 22
Contents
1 Brief Introduction.............................................................................................................................6
1.1 Overview............................................................................................................................... 6
1.2 Feature................................................................................................................................... 6
1.2.1 Industrial Application Design.................................................................................... 6
1.2.2 Reliability................................................................................................................... 6
1.2.3 Easy to use..................................................................................................................7
1.2.4 Function......................................................................................................................7
1.3 Specification..........................................................................................................................8
1.3.1 Basic Parameters........................................................................................................ 8
1.3.2 Physical Feature......................................................................................................... 8
1.3.3 Environment Parameter..............................................................................................8
2 Installation........................................................................................................................................ 9
2.1 Overview............................................................................................................................... 9
2.2 Package List.......................................................................................................................... 9
2.3 Tower or Pole Installation..................................................................................................... 9
2.3.1 Tool.............................................................................................................................9
2.3.2 Installation Angle and Height.................................................................................... 9
2.3.3 Installation Process.................................................................................................. 10
3 Platform Software...........................................................................................................................11
3.1 Overview............................................................................................................................. 11
3.2 Add New Equipment........................................................................................................... 11
3.3 Real-time Monitoring..........................................................................................................14
3.4 Photo Rotation.....................................................................................................................15
3.5 Warning Process..................................................................................................................16
3.4 Alarm Process......................................................................................................................16
3.6 Configuration Policy........................................................................................................... 17
3.7 Statistics.............................................................................................................................. 18
3.8 System Management........................................................................................................... 19
4 Wechat Function.............................................................................................................................20

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 6 of 22
1 Brief Introduction
1.1 Overview
Power line security camera (F-PLS) is used to monitor the overhead power line (including
transmission line and distribution line,tower and pole).F-PLS takes photo or short video
periodically or manually,prevent the power line from damaging by people,vehicle or some other
construction machines,such like theft the power line or equipment,wildfire,tower
crane,excavator,especially in the construction site or the road which power line across.
F-PLS is a special camera which integrate with solar panel and battery inside. it also has 2G/3G/4
G communication, GPS positioning, 433MHz access, image recognition, line temperature measure
ment, environmental monitoring, voice broadcast and other functions.
F-PLS is an important part of power line monitoring system. Adopting technologies of image acqu
isition, data calculation, remote control, it provides an intelligent and visible real-time status monit
oring solution for power line and power equipment.
Pic 1-1 system diagram
1.2Feature
1.2.1 Industrial Application Design
High performance 64 bit processor
Stainless steel support
IP67 protection
“Solar energy + battery+ super capacitor” multi power source design
1.2.2 Reliability
Re-transmission mechanism, data not easy lost
Photo priority and video assistant, high on-line rate and low communication failure
Support 30 days continuous working without light
8 year life span
30000 hours MTBF

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 7 of 22
2G/3G/4G antenna, GPS antenna, WIFI antenna, 433MHz antenna embedded
SIM card embedded
1.2.3 Easy to use
Support National Grid online monitoring standard, National Grid encryption, Southern Grid
online monitoring standard
Compliant with transmission line photo/video specification standard
Small size, light weight, compact structure
Easy installation within 10 minutes
Mounting bracket can be adjusted horizontally 360 degree and vertically 90 degree
Support access to sound and light, temperature, meteorological module
1.2.4 Function
Item
Content
F-PLS100
F-PLS110
Timed photo
support
Timed video
support
Remote manual photo
support
Remote manual video
support
Real time video
Not support
support
Sound and light function
support
Remote Shout Function
support
Platform control function
support
Zoom function
Not support
support
Night shot function
Not support
support
Intelligent analyse function
Not support
support
Micro Meteorology access
function
support
Line temperature measuring
access function
support
Auto & Manual working mode
function
support
Near field debug function
support
Table1-Function

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 8 of 22
1.3 Specification
1.3.1 Basic Parameters
Table 2- Basic Parameters
1.3.2 Physical Feature
Table 3-Physical Feature
1.3.3 Environment Parameter
Item
Content
F-PLS100
F-PLS110
High definition lens
8 Mega pixel, max 2100 Mega
pixel optional
8 Mega pixel, max 2400 Mega pixel
optional
Low light lens
/
2 Mega pixel, min light 0.001Lux
Zoom lens
/
20 times
Down view lens
/
Support high definition, low light lens
Tripod head
256 preset positions, 360° horizontally, 110° vertically
Sound light Shout
200 m visible to light and hear sound
Micro
Meteorology
2 factors
wind direction, wind speed
5 factors
wind direction, wind speed, air pressure, temperature, humidity
6 factors
wind direction, wind speed, air pressure, temperature, humidity, rainfall
Line temperature
measurement
Range -40~+290℃, accuracy ±1℃,minimum start current 20A,Non-closed
CT take power, current capture each 1 min
Adjusted angle
Horizon 360°,vertical 90°
Power supply
Solar energy + Lithium iron phosphate battery + Super capacitor
Solar panel
12W
40W
Battery
Embedded 10Ah
Embedded 20Ah
Life time
10 pictures each day. Support 30
days working without light
50 pictures each day, support 30 days
working without light. 1 hour video each
day, support 30 days working without
light.
Network Standard
All network supported
Life span
Above 8 years
Item
Content
F-PLS100
F-PLS110
Weight
≤5kg
≤15kg
Structure
Solar panel and main machine integrated design
IP level
IP67

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 9 of 22
Table 4-Environment Parameter
2 Installation
2.1 Overview
The equipment must be installed correctly to achieve the designed function, usually the
equipment must be installed under the guidance of qualified engineers recognized by the company.
2.2 Package List
For a safe transportation, the equipment usually needs a reasonable packing. Please take good
care of the packaging materials when you unfold the box, so that it can be used in future
transportation.The unpacking list is as follows:
Table 5- Equipment List
2.3 Tower or Pole Installation
2.3.1 Tool
Adjustable spanner :1 set
Slot type screwdriver:1 set
2.3.2 Installation Angle and Height
Camera direction: should be installed horizontal or downward, but not upward
direction. Hidden area (such as construction site, accumulation, pond, fire, etc.) around
the line/tower should be in the center of the image.
Solar panel: solar panel should be installed at SBW 10 °, without shelter, mainly toward
the south.
Installation height: Camera installed at the lowest point of the wire sag is with the best
Item
Content
Working
temperature
-25~+70℃
Storage temperature
-40~+85℃
Relative Humidity
0~100%RH (No condensation)
Items
Details
F-PLS100
F-PLS110
Camera and solar panel Integrated Device
1 Set
1 Set
Pan-and-tilt camera Integrated Device
(Optional) 1set
(Optional) 1set
Loud-speaker
(Optional) 1set
(Optional) 1set
Micro-weather sensor
(Optional) 1set
(Optional) 1set
Battery and solar panel integrated Device
(Optional) 1set
(Optional) 1set
Wire temperature sensor
(Optional) 1set
(Optional) 1set
Installation Instruction
1 Volume
1 Volume
Warranty Card
1 Volume
1 Volume
Certificate of Qualification
1 Volume
1 Volume

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 10 of 22
shooting Angle, as far as possible to install on high to prevent theft, try to apply the
cross-brace installation.
2.3.3 Installation Process
Pic :2 -1 Pic:2-2
Remove the package.then pull out the solar panel cable and fix it to panel side (hide it in
panel backside and fix it by plugging it to the panel edge), Finally, lock the No.1 and
No.2 screws.
Turn on the power switch and observe and check the red light, if it is blinking normally,
it means normal operation.
Preset the direction of solar panel and camera according to the shooting area and
suspension direction, and pre-install the device. Configure the WeChat account of
on-site debugging person and input related equipment on the platform. Then find the
line to be installed, and test the automatic take photo function.
Pic:2 -3 Pic:2-4
Hook the angle iron with two screw hooks and lock it with a screw head. As per photo
2-3.
After adjusting the solar panel and camera angle, tighten screws No.1,2,3 and 4.as per
photo 2-4.
Note:
Screw 1: adjust the horizontal angle of the solar panel
Screw 2: adjust the levelness of the camera
Screw 3: adjust the horizontal direction of the camera
Screw 4: adjust the vertical direction of the camera

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 11 of 22
3 Platform Software
3.1 Overview
The software and hardware of the platform shall be used together. After the installation of the
equipment, users can check the position, pictures, video, sensor data and other information on the
platform. Users shall ask for the account number and password from the service staff before
logging into the platform initially.
3.2 Add New Equipment
Step 1: Add power lines and tower poles (after adding tower pole, remember to add "monitor
point" information).
Pic 3-1
Pic 3-2

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 12 of 22
Pic 3-3
Step 2: Add SIM card and camera information (after that, it must be installed on the tower, and the
installation of temperature measurement module and weather module is with the same steps.)
Pic 3-4
图3-5

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 13 of 22
图3-6
图3-7
Step 3: Correlate the devices to the group and user as required
Pic 3-8

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 14 of 22
Pic 3-9
Pic 3-10
3.3Real-time Monitoring
After adding the device, the data information of the device can be viewed in the real-time
monitoring.
Click "real-time monitoring" and select the device to view to see all pictures of the device,
click any picture to enter the large picture display and operation page, then historical pictures,
temperature data, weather data will be indicated in the picture.and it also can auto-take photos,
take auto-record video, view location information, set group and hidden danger types, etc..

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 15 of 22
Pic 3-11
Pic 3-12
3.4Photo Rotation
Picture rotation can replace manual view of equipment pictures. Set rotation conditions after
entering this page, and then start rotation.

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 16 of 22
Pic 3-13
3.5Warning Process
The platform analyzes the pictures and video data reported by the monitoring and
photographing device in real time, and displays the hidden trouble pictures in the first time when
hidden trouble occurs near the corridor of the line. Users can also conduct corresponding
operation for the hidden trouble.
Pic 3-14
3.6Alarm Process
The platform analyzes the pictures and video data reported by the monitoring and
photographing device in real time, and displays the hidden trouble pictures in the first time when
hidden trouble occurs near the corridor of the line. Users can also conduct corresponding
operation for the hidden trouble.
Pic 3-15

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 17 of 22
3.7Configuration Policy
The platform can set the rules of taking photos, temperature alarm, micro weather alarm, etc.
Since the device is in a dormant state when it is not in working status, it takes a certain time to
take effect after parameter setting.
图3-16
Pic 3-17

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 18 of 22
Pic 3-18
3.8Statistics
The platform carries out automatic statistics on warning and alarm, operation status and
device information, and the corresponding statistical information can be viewed through the
statistics interface.
Pic 3-19

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 19 of 22
Pic 3-20
3.9System Management
The platform supports the management of gourps, roles, users, and organizational parameters
(not all users have this capability, depending on the level of the account).
Pic 3-21
Pic 3-22

F-PLS User Manual
F-PLS-V1.0 en.four-faith.net
Page 20 of 22
Pic 3-23
Pic 3-24
4 Wechat Function
Real-time Photo Delivery: every photo taken by the device is immediately delivered to the