Operang voltage / Power supply 85-230VAC, 50/60Hz
Standby power < 1.0W
Rated current / Relay 16A resisve load, 230V / SPST
Seng range, temperature 5-45°C
Floor limitaon, temperature range 20-45°C
On/O dierenal ±0.5°C
Humidity sensor, air 0-100%
Operang modes
Three programming modes:
Weekday/Weekend (5 + 2)
- edit/set 4 me periods per day
Seven day programming (7)
- edit/set 4 me periods per day
24 hours mode
- edit/set 4 me periods
Hold/Timer mode:
- acvate and adjust a boost period of
up to 24h, by oponal seng range
temperature
Home/Away mode:
- the controller will turn on the heat-
ing, if the room temperature drops
below the set value.
Holiday mode:
- calendar based and programmable
in advance.
OFF mode:
- frost protecon included, by adjust-
able temperature range
Baery backup 2 months
Appliance and protecon class Class II - IP20
Size (H/W/D) 86/96/44 mm
Build-in depth 30 mm
Installaon type Flush, hole pitch 60 mm
Terminals 2.5 mm², screw cage clamp
Terminal wire size max. 2.5 mm²
Display size 3.5” - Color capacive touch
Display resoluon 480x320 TFT
Oponal external oor sensor NTC (10 kΩ), Class II, 3 meter
Oponal external room/air sensor NTC (10 kΩ), Class II, 3 meter
Max. length sensor cable 50 m, 2 x 1.5 mm²
- Low Voltage Direcve 2014/35/EU
- EMC Direcve 2014/30/EU
- RoHS Direcve 2011/65/EU
- Radio Equipment Direcve 2014/53/EU
- Electrical Equipment (Safety) Regulaons 2016
- Electromagnec Compability Regulaons 2016
-
RT2RT1NNLLoad
230VAC
~~
FRENGER Systems Limited | Riverside Road | Pride Park | Derby | DE24 8HY
E - sales@frenger.co.uk | T - +44 (0)1332 295 678 | F - +44 (0)1332 381 054
22.03.29-V1.3
TECHNICAL SPECIFICATION
Programming and Setup
The controller carries a lot of features and sengs.
In order to access these points please contact our
technical department for a copy of the user manual.
This document will guide you through the setup of
the dierent funcons and modes.
OPERATING THE CONTROLLER
When powering up the thermostac programmable controller, it
will automacally start to run in mode with the factory sengs.
There is no mechanical ON/OFF switch. To access this feature,
simply so tap on the touchscreen and/or the symbol
External Sensor
Floor Sensor
Output, max 16A
Main Supply
230V
Wiring
Connect the wires in accordance with the diagram. The wires
must be connected as follows:
Output (neutral)
Power supply (neutral)
Power supply (live)
Output, max. 16A (3680W)
External oor sensor (hot)
External room/air sensor (hot)
Sensor connecon point (cold)
Terminal Marking
Terminal N:
Terminal N:
Terminal L:
Terminal Load:
Terminal RT1:
Terminal RT2:
Terminal - (minus):
CONNECTIONS - WIRING
-
RT2RT1NNLLoad
Model: T60
Supply voltage: 85-230V~ 50/60Hz
Rated current: 16A resistive load
Ingress protection code: IP20
RoHS