OPERATING THE CONTROLLER
When powering up the thermostatic programmable controller,
it will automatically start to run in mode with the factory
settings. There is no mechanical ON/OFF switch. To access this
feature, simply soft tap on the touchscreen and/or the symbol
FRENGER Systems Limited | Riverside Road | Pride Park | Derby | DE24 8HY
E - sales@frenger.co.uk | T - +44 (0)1332 295 678 | F - +44 (0)1332 381 054
TECHNICAL SPECIFICATION
18.08.22-01EN
Operang voltage / Power supply 85-230VAC, 50/60Hz
Standby power < 1.0W
Rated Current / Relay 16A resisve load, 230V
Seng range, temperature 5-45°C
Floor limitaon, temperature range 20-45°C
On/O dierenal ±0.5°C
Humidity sensor, air 0-100%
Operang modes
Three programming modes:
Weekday/Weekend (5 + 2)
- edit/set 4 me periods per day
Seven day programming (7)
- edit/set 4 me periods per day
24 hours mode
- edit/set 4 me periods
Hold/Timer mode:
- acvate and adjust a boost period of
up to 24h, by oponal seng range
temperature
Home/Away mode:
- the controller will turn on the heat-
ing, if the room temperature drops
below the set value.
Holiday mode:
- calendar based and programmable
in advance.
OFF mode:
- frost protecon included, by adjust-
able temperature range
Baery backup 2 months
Appliance and protecon class Class II - IP20
Size (H/W/D) 86/96/44 mm
Build-in depth 30 mm
Installaon type Flush, hole pitch 60 mm
Terminals 2.5 mm², screw cage clamp
Terminal wire size max. 2.5 mm²
Display size 3.5” - Color capacive touch
Display resoluon 480x320 TFT
Oponal external oor sensor NTC (10 kΩ), Class II, 3 meter
Oponal external room/air sensor NTC (10 kΩ), Class II, 3 meter
Max. length sensor cable 50 m, 2 x 1.5 mm²
CE Direcves EMC Direcve 2014/30/EU
RoHS Direcve 2011/65/EU
Wiring
Connect the wires in accordance with the diagram. The wires
must be connected as follows:
CONNECTIONS - WIRING
Terminal Marking
Terminal - (minus):
Terminal RT2:
Terminal RT1:
Terminal N:
Terminal N:
Terminal (empty):
Terminal L:
Terminal Load:
Sensor connecon point (cold)
External room/air sensor (hot)
External oor sensor (hot)
Output (neutral)
Power supply (neutral)
Do not connect
Power supply (live)
Output, max. 16A (3680W)
Programming and Setup
The controller carries a lot of features and settings.
In order to access these points please contact our
technical department for a copy of the user manual.
This document will guide you through the setup of
the different functions and modes.
Output, max 16A
Main Supply
230V
Sensor Connection Point
(cold wire)
External Sensor
(hot wire)
Floor Sensor
(hot wire)