Fresh-Aire FALLH-01 Series User manual

Personal Ultrasonic Humidifier
FALLH-01 series

Important safeguards
WHEN USING ELECT ICAL P ODUCTS, ESPCIALLY WHEN CHILD EN A E P ES NT, BASIC
SAFETY P ECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE DOLLOWING:
EAD ALL INST UCTION BEFO E USING
DANGE
– TO EDUCE THE ISK OF ELECT IC SHOCK:
Always place humidifier on a firm, flat surface. A waterproof mat or pad is
recommended for use under the humidifier. Never place it on a rug or carpet, or on a
finished floor that may be damaged by exposure to water or moisture.
Always unplug the unit from the electrical outlet immediately after using and before
cleaning
DO NOT reach for a unit that has fallen into water. Unplug it immediately.
DO NOT us while bathing or in the shower.
DO NOT place or store the unit where it can fall or be pulled into a tub or sink.
DO NOT place or drop into water or other liquids.
DO NOT use water above 86°Fahrenheit.
WA NING
-TO EDUCE THE ISK OF BU NS, ELECT IC SHOCK, O INJU Y TO PE SONS:
A unit should never be left unattended while plugged in.
Close supervision is necessary when the unit is used by or near children, invalids, or
disabled persons.
Use this unit only for its intended use as described in this manual. Do not use
attachments not recommended by the manufacturer, specifically do not use any
attachments not provided with this unit or supplied by the manufacturer.
NEVE drop or insert any object into any opening.
DO NOT operate where aerosol (spray) products are being used, or where oxygen is
being administered.
Always hold the water tank firmly with both hands when carrying a full thank of water.
NEVE use the humidifier in an environment where explosive gasses are present.
DO NOT place the humidifier near heat sources, such as a stove and do not expose the
humidifier to direct sunlight.
DO NOT carry this unit by the power cord or use the power cord as a handle.
TO disconnect, turn all controls to the “off” position, then remove the plug from the
outlet.
This unit is designed for personal, non-professional use only.
DO NOT use outdoors. For indoor use only.
SAVE THESE INST UCTIONS
CAUTION
-PLEASE EAD ALL INST UCTIONS CA EFULLY BEFO E OPE ATION
Never cover the unit while it is operating.
Always keep the cord away from high temperature and fire.
If the cord sustains damage, you must stop using the product immediately and
contact Fresh Aire consumer relations (see Warranty section for consumer
relations contact information).
Perform regular maintenance on the ultrasonic membrane.
Never use detergent to clean the ultrasonic membrane.
Never clean the ultrasonic membrane by scraping with a hard object.
DO NOT attempt to adjust or repair the unit. Servicing must be performed by
professional or qualified personnel.
Stop using this unit if there is an unusual noise or smell.
Unplug this unit when not in use for a long period of time.
Do not touch the water or any parts of the unit that are covered by water while
the unit is on or plugged in.
Never operate without water in the tank.
Only use water in the tank.
Never use any additive to the water.
Do not wash, adjust, or move the unit without first unplugging it from the
electrical outlet.
Keep this unit out of reach of children. Do not allow children to use this unit
without supervision.
-- 1 -- -- 2 --

Unique Features and Specifications
Ultrasonic Technology
This humidifier uses ultrasonic high frequency technology to turn the water into 1-5 million
super particles that are dispersed into the air evenly.
Wick
Includes wicks. One wick is already installed and there are 2 additional replacement
wicks included.
120V AC Adaptor Included
Perfect for use at home, in the office, or on-the go.
Voltage Tank Capacity
5V DC 50ml
How to Use
Power ON/OFF
Insert single pin plug into base of humidifier, then plug unit in to a 120 volt AC electrical
outlet. Push the POWER Button once to turn unit on with light. Push POWER
Button again to keep the unit on with light off .Push the POWER Button again to turn
the unit off.
How to Fill the Humidifier
CAUTION: Before filling with water, turn power off and unplug.
1. To remove the mist spout, turn the top to right until the icons align
In the “unlock” position. Lift up to remove the mist spout and
Set it aside. (See Fig. )
2. NOTE :For first time use and with each new wick, you must
soak the wick in water before operating. Unlock the spring loaded
wick by turning the wick holder to the left. Remove the wick from the
wick holder and soak the wick in water for 20 minutes. Return the
wick to the wick holder and secure to the humidifier top cover by
turning to the right.(See Fig. 4)
CAUTION: DO NOT operate the humidifier without first soaking
the wick. The humidifier WILL NOT function without a wick or if
the wick is dry.
. Fill the water tank with clean, cool (not cold) tap water to the MAX
FILL line. DO NOT OVERFILL. We recommend using distilled
Water if you live in a hard water area. (See Fig. 5)
4. Place the mist spout back on the unit, making sure the icons
Align in the “unlock” position. Look into place by turning the
top to the left until the icons are aligned in the “lock”
position. (See Fig.6A&6B)
NOTE: Be sure to wipe away and excess water from the top of
the tank before replacing the mist spout.
5. Plug adaptor into standard wall outlet.
6. To turn on, press the POWER Button. The POWER Button
Will illuminate when the humidifier is ON.
NOTE: This humidifier does not include an Auto Shut-off when
the unit runs out of water. The unit MUST be unplugged when
not in use. Refill or turn off before the tank runs dry. Never leave
humidifier on if you will be away for more than 4 hours.
FIG.1
FIG.2
Fig.3
Fig.4
Fig.5
Fig.6A
Fig.6B
-- 3 --
-- 4 --

How to Change Wick
1. Remove replacement wick from package and soak in water for 20 minutes.
2. Remove the mist spout by turning it to the right until the icons align in the “unlock” position.
Lift up to remove the mist spout and set it aside.
. Unlock the spring loaded wick by turning the wick holder to the left and removing from the top
Cover.(Fig.4)
4. Remove the old wick from the wick holder and discard.(Fig.7)
5. Place the new, soaked wick into the wick holder.(Fig.7)
6. Place the wick holder back on the unit and lock into place by turning the holder to the right.
NOTE : To order additional replacement wicks Model# FALLH-01, please visit
www.fresh-aire.com or call Futec Products Limited (852)2793 0886
Cleaning and Care
CAUTION: Before cleaning the unit, turn power off and disconnect the
Plug from the unit.
Tank Cleaning
Remove the mist spout from the water tank. We suggest cleaning the
Water tank once every two to three weeks, depending on your water
Conditions. Clean tank using a 50/50 mix of vinegar and water.
Ultrasonic Membrane Cleaning
To clean the ultrasonic membrane, you must first remove the spring
loaded wick. Remove the mist spout.
Make a 50/50 solution of vinegar and water. Dip a soft bristle brush into
the solution and brush ultrasonic membrane. Wipe clean with a soft
cloth. Clean both sides of membrane.
NOTE: DO NOT pour water into the ultrasonic membrane or submerge
in water.
Surface Cleaning
Clean the surface of the unit with a clean damp soft cloth.
Wick
Wick Holder
FIG.7
-- 5 --
-- 6 --

Troubleshooting
P OBLEM POSSIBLE CAUSE SOLUTION
Power Light off
Unit is not plugged in
No power at unit
Plug unit in
Push POWE button to turn
the power on
Check circuits, fuses, try a
different outlet
Power Auto
Shut off
Operation over time efill the water
Press the On/OFF Button
again to restart the unit.
Peculiar Odor Unit is new
If unit is in use, the odor
may be a dirty water
reservoir, old tank water
or an old wick
Empty any water and clean
and refill tank
eplace wick
Excessive
Noise
Unit is not level
Low water level
Wick was not soaked
Place unit on a flat, even
surface
Check the water level.
efill the reservoir if the
water is low.
emove wick, soak for 2
minutes and replace wick
NOTE: This device complies with Part 18 of the FCC Rules
Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
Note: The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user
authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 18 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
-- 7 -- -- 8 --
Table of contents
Popular Humidifier manuals by other brands

DriSteem
DriSteem HUMIDI-TECH Installation instructions and maintenance operations manual

Aprilaire
Aprilaire 400 Series manual

HoMedics
HoMedics UHE-OW14BK instruction manual

Hunter
Hunter 33222 user manual

Emerson
Emerson MoistAIR HD1405 owner's manual

Vornado
Vornado Ultrasonic Vortex Humidifier owner's guide