General instructions
Read these instructions carefully before
installation and use. Keep this manual
for future reference.The product may
only be used as set out in the assembly
and operating instructions. The war-
ranty is only valid if the product is
used in the manner intended and in
accordance with the instructions.
Important The underoor heating system
is an electrical power installation and must
therefore be installed in accordance with the
current regulations and under the supervision
of a qualied electrician.

3
EN
This is TAP16R
In the box
Installing TAP16R
Getting started
How TAP16R works
Symbols on the display
How to set TAP16R
Energy saving programs
Troubleshooting
Technical specications
............................................. 4
..................................................... 5
....................................... 6
........................................... 8
................................... 9
......................... 16
................................. 17
...................... 21
..................................... 26
....................... 27

4
This is TAP16R
TAP16R is a microprocessor-controlled
thermostat with LCD display. The dis-
play is backlit and stays lit for 30 sec-
onds after the last push of a button.
The front is tted with an LED and three
control buttons.
There are a number of temperature re-
duction programs to choose from for
energy-smart heating. It is also possible
to adjust the programming to suit your
own heating needs. The adaptive fun-
ction means that the thermostat col-
lects data from the time it is started up
and uses this to calculate when to turn
on.
Temperature control is done with an
algorithm using fuzzy logic. This techni-
que reduces temperature uctuations
and thereby provides a more even tem-
perature and lower energy consump-
tion.

5
EN
In the box
1
2
3
4
5
1. Front for Schneider Exxact (RAL 9003)
2. Frame
3. Thermostat
4. Heightening frame
5. Connection clip
Manual
Quick guide

6
Installing TAP16R
Important TAP16R must not be located
somewhere it is exposed to the
following:
• direct sunlight and draughts.
• extreme uctuations in temperature
or high air humidity (IP21).
All tubes leading into the appliance box
must be sealed so that the air tem-
perature sensor cannot be aected by
draughts.
Installation
Mount TAP16R in a standard 65 mm
junction box or in the included heigh-
tening frame.
1. Make sure the box is level with the wall.
2. Take o the front and frame by press-
ing in the latch on the right-hand side
with a chisel or similar tool, as shown in
the illustration.
3. Connect the power, connection vol-
tage 230 V/AC The protective conduc-
tor is connected with a coupling clamp
in the box. See the wiring diagram at
the right.

7
EN
4. Insert the thermostat into the ap-
pliance box and screw tight with the
existing screws.
5. Fit the frame and front.
6. If the thermostat is mounted in a
multi-compartment frame, the internal
corners of this frame must be removed.
External sensors (NTC 10 kΩ) are
available as accessories.
LOAD LOAD
N
L
SENSOR
SENSOR
DO NOT USE
230 V

8
Getting started
There is a quick guide so that you can
easily get started with TAP16R.
You will nd it in the box. The guide
describes the most important
functions and settings.

9
EN
LED
Select button
Dag
Time
Temp
Selected control
How TAP16R works
This section describes all you need
to know about how Tap16R works. To
learn how to enter settings to suit your
own requirements, read the section
How to set TAP16R.
Display
Turn on the LCD display’s backlight by
pressing any button. The display stays lit
for 30 secs after the last push of a button.
When TAP16R is started for the rst
time the display shows the factory
settings as in the illustration.

10
How to enter personal settings is
described in the section How to set
TAP16R.
There is an explanation of the symbols
on the display in the section Symbols.
Using the buttons
The buttons are used to raise and lower
the temperature as well as navigating
the menus.
You access the menus by pressing
the select button . Use the arrows to
navigate to a menu option and then
conrm with to select it. The menu
system is a scrolling system, in other
words you come to all submenus re-
gardless of the direction you start from.
If you want to exit a menu, navigate
until the display shows END. Then
press the select button . You can also
wait for 30 secs and the menu will end
automatically. How to navigate the
menus is described in the section How
to set TAP16R.
Turning TAP16R o and on
To enter standby mode, keep the select
button depressed for 4 seconds.
Return to normal mode by depressing
for another 4 seconds.

11
EN
The heating is not controlled in stand-
by mode. The clock runs as normal and
programmed times and temperatures
remain in the memory.
Locking the keypad
The keypad can be deactivated to
prevent anyone touching the buttons
by mistake. This is shown with the lock
symbol in the display.
Press and navigate to LOCK. Conrm
with to lock.
Unlock by holding down both arrows
until the key symbol has disappeared.
Temperature
Display of the actual temperature (actual
value) Lock the keypad rst. Press .
The light turns on and the current
temperature in the room (R) is shown
with small numbers above the desired
temperature. If an external sensor is
used, its current temperature (F) is
shown instead.
The temperature is shown for 30 secs
after the last push of a button.

12
Time and date
Time can be shown in 12- or 24-hour
format. The correct day of the week is
worked out automatically. The calendar
resets itself in leap years and adapts
to DST. Read how to set the correct
time and date in the section How to set
TAP16R/Time and date.
Adaptive function
TAP16R has a function which works out
when the heating should start to give
the correct temperature at the correct
time. It is activated on delivery, but can
be turned o:
Press and navigate to SET. Select with
. Navigate to AF, select with .
Navigate between ON/OFF, then con-
rm with .
Ventilation mode
If the room temperature falls by more
than 3 °C in a single minute, e.g. when
airing the room, the ventilation mode
is activated. TAP16R will then stop
heating for 15 minutes before return-
ing to normal mode. This function is
always active.

13
EN
Delay between turning o and on
There is a built-in delay in order to
avoid unnecessary wear and tear on
internal components and to extend
the life of the thermostat. If you raise
the desired temperature so that the
thermostat comes on, and then lower
it shortly afterwards, it takes 30 sec
before it goes o again.
Operation time
The thermostat can display the opera-
tion time as a percentage for the last
24 hours and 7/30/365 days.
Press and navigate to UTIL. Press
to select. The display now shows the
operation time as a percentage for the
last 24 hours. You can then navigate
between the operation time as a per-
centage for the last 7/30/365 days.
LED
The LED allows you to see the current
status of TAP16R.
Green light –the thermostat is on and
the heat is turned o.
Red light –the thermostat is on and
the heat is turned on.

14
Flashing green and red lights –error
indication. The heat is turned o. The
thermostat shows the error message
until it is turned o. Find out more
under Error codes.
No light – the thermostat is switched
o or is not getting any power.
Control functions
TAP16R can regulate the temperature
in three dierent ways.This enables the
comfort temperature and any ooring
temperature requirements to be com-
bined. How you select the function you
want is described in the section How to
set TAP16R/Control functions.
External sensor – If the external sensor
is connected when the thermostat
is switched on for the rst time, this
function is selected automatically. The
preset to value is 22 °C.
Room thermostat – TAP16R has a
built-in sensor to measure the room
temperature and control the heat. The
control function cannot be selected if
the external sensor is connected.

15
EN
Room sensor and external sensor (com-
bined) – Not normally used. The built-in
sensor controls the room temperature
and the external sensor works as a
temperature limiter. The limitation is
adjustable between 5 °C and 45 °C.

16
Symbols on the display
1. Day of the week
2. Time and date
3. Selected menu/Current temp
(actual value) °C
4. Set temp (set point) °C
5. Selected control
6. Shows that a program is running
7. Lock symbol
8. Program
9. Event functions for personal settings
1
2
4
3
5
8
9
6
7

17
EN
How to set TAP16R
This section describes how to set up
TAP16R. By adjusting these settings,
you can customize the heating system
to your own needs.
If you want to nd out more on how to
navigate the menus or use the keypad,
read the section How TAP16R works.
Reset
You use the Reset function to make
TAP16R revert to default factory set-
tings. All your personal settings will be
deleted.
Press and navigate to SET. Select with
. Navigate to RST and select with .
Navigate between YES/NO, then con-
rm with . YES deletes the settings,
NO returns to the menu.

18
Light and contrast
Set the light intensity of the LED
Press and navigate to SET. Select with
. Navigate to LED and select with .
Navigate between LED L (weak light)
and LED H (strong light). Conrm with
.
Set display contrast
Press and navigate to CONT. Press
to select. The display shows a number
between 1 and 8 depending on the
current setting. Navigate to regulate
the contrast. Conrm with when you
have achieved the correct level.
Time and date
Set time and date
Press and navigate to SET. Select with
. Navigate to CLK and select with .
First set the hours by navigating to the
correct time and conrm with .
Set the minutes in the same way and
conrm with .
Set the day, month and year in the
same way. Conrm with . The correct
day of the week is set automatically.

19
EN
Set time format
Press and navigate to SET. Select with
. Navigate to DISP and select with .
Navigate between 12- and 24-hour
format. Conrm with .
Turn o DST
The calendar switches to DST automat-
ically. This function can be turned o.
Press and navigate to SET. Select with
. Navigate to S and select with .
Navigate between ON/OFF, then con-
rm with .
Temperature
Change desired temperature (set point)
Each press of the up or down arrow
increases or decreases the temperature
by 0.5 °C.

20
Control functions
These are described in more detail in
the section How TAP16R works/Control
functions.
Select control function
Press and navigate to SET. Select with
. Navigate to RNF and select with .
The icon for the current function (R, F
or R&F) ashes. Navigate between the
dierent options and conrm with .
Important R cannot be selected if the exter-
nal sensor is connected.
Adjustment of the temperature limitation
for the room sensor and external sensor
(combined) (R&F)
Press and navigate to SET. Select with
. Navigate to OH and select with .
The set temperature now ashes on
the display. Navigate to the desired
temperature and conrm with .
Other manuals for TAP16R
1
Table of contents
Other Frico Thermostat manuals