FSN FS-P2404D User manual

Medical Display
FS-P2404D, P2604D
User’s Guide
Before connecting, operating or adjusting this product, please
read this instruction booklet carefully and completely.

FSN1986 - 11/2017
2 - English
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Symbol Denitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
FCC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Connectors, Power Management . . . . . . . . . . . . . . . . . . . 15
Mechanical Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
On Screen Display (OSD) . . . . . . . . . . . . . . . . . . . . . . . . 19
OSD System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Standard Signal Tables. . . . . . . . . . . . . . . . . . . . . . . . . . 31
Signal Connector Pin Assignments . . . . . . . . . . . . . . . . . . 32
General Specication . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Cleaning Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . 36
The specications and information in this document are subject to change without notice.

FSN1986 - 11/2017 English - 3
Overview
FS-P2404D, FS-P2604D
This product from FSN Medical Technologies is a high-end surgical display monitor designed for
advanced digital OR applications. This medical display is uniquely equipped to handle tasks in
the demanding operating room environment. The video input options cover a wide selection
of popular medical signal standards. This unit features LED backlight technology and a bonded
front lter that increases contrast ratio, brightness, humidity tolerance, and breakage resistance.
We have implemented methods to ne-tune the properties of FSN displays. Distinct color space
settings have been calibrated to well-known surgical color preferences, providing the user with
the ideal surgical visualization system. Features include:
t Rapid signal detection, robust mode tables
t Artifact-free HD images
t Fanless - sterile eld compatible
t Calibrated to clinical color
t Image pan, zoom, freeze, picture-in-picture
FSN Medical Technologies has solutions for managing your operating room video signals. Our
products are engineered and built for compatibility with other highly specialized surgical and
diagnostic equipment used in surgical suites, operating rooms, emergency rooms, and proce-
dural facilities.

FSN1986 - 11/2017
4 - English
Symbol Denitions
The following symbols appear on the product, its labeling, or the product packing. Each symbol
carries a special denition, as dened below:
Dangerous : High Voltage Power adapter
Direct Current lndicates equipotential earth
ground
Indicates protective earth
ground
Indicates top-bottom
direction
DC Power control switch Fragile
Do not get wet Maximum Stacking
Consult the operating instruc-
tions.
Indicates the
manufacturer
Indicates the
manufacturing date
Authorized representative in
the European community
Korea Certication Humidity limitation
Serial Number Atmospheric pressure
limitation
Temperature limitation

FSN1986 - 11/2017 English - 5
Indicates proof of conformity to applicable European Economic Community
Council directives and to harmonized standards published in the ocial journal
of the European Communities.
Medical Equipment is in accordance with UL 60601-1 and CAN/CSA C22.2 No.
601.1 in regards to electric shock, re hazards, and mechanical hazard.
Tested to comply with FCC Class B standard.
Indicates the display is approved according to the CCC regulations.
China RoHS labels.
This symbol indicates that the waste of electronic equipment must not be
disposed as unsorted municipal waste and must be collected separately. Please
contact the manufacturer or other authorized disposal company to
decommission your equipment.
Language: English
Note: A printed copy of the manual in English is provided with the product. Users within EU
member states, please contact local distributor for other languages or refer to the CD manual
enclosed with the product. This applies to EU member states where the product has been pur-
chased through authorized channels.

FSN1986 - 11/2017
6 - English
Safety Instructions
On Safety
1. Before connecting the AC power cord to the DC adapter outlet make sure the voltage desig-
nation of the DC adapter corresponds to the local electrical supply.
2. Never insert anything metallic into the cabinet openings of the medical LCD monitor. Doing
so may create the danger of electric shock.
3. To reduce the risk of electric shock, do not remove cover. No user-serviceable parts inside.
Only a qualied technician should open the case of the medical LCD monitor.
4.
Never use your medical LCD monitor if the power cord has been damaged. Do not allow anything
to rest on the power cord, and keep the cord away from areas where people can trip over it.
5. Be sure to hold the plug, not the cord,when disconnecting the medical LCD monitor power
cord from an electric socket.
6. Unplug your medical LCD monitor power cord when it is going to be left unused for an ex-
tended period of time.
7. Unplug your medical LCD monitor power cord from the AC outlet before any service.
8. If your medical LCD monitor does not operate normally, in particular, if there are any unusual
sounds or smells coming from it, unplug it immediately and contact an authorized dealer or
service center.
9. Please contact the manufacturer if the set should be installed in an inaccessible area.
Warning: Do not touch input or output connectors and the patient simultaneously.
Warning: This medical LCD monitor is intended for connection to input/output signals and other
connectors that comply with relevant IEC standard (e.g.,IEC60950 for IT equipment and IEC60601
series for medical electrical equipment). In addition, all such combination-system shall comply
with the standard IEC 60601-1-1 or clause 16 of the 3 Ed. of IEC 60601-1, respectively, safety re-
quirements for medical electrical systems. Any person who has formed a combination-system is
responsible for the system to comply with the requirements of IEC 60601-1-1 or clause 16 of the 3
Ed. of IEC 60601-1, respectively. If in doubt, contact qualied technician or your local representative.
Warning: To avoid risk of electric shock, this equipment must only be connected to a supply
mains with protective earth. Power supply (AC/DC Adapter) is specied as a part of the LCD Color
Display. Do not to position equipment so that it is dicult to disconnect the power cord plug
from the appliance inlet.
Warning: Do not modify this equipment without authorization of the manufacturer.

FSN1986 - 11/2017 English - 7
On installation
1. Openings in the medical LCD monitor cabinet are provided for ventilation. To prevent over-
heating, these openings should not be blocked or covered. If you put the medical LCD moni-
tor in a bookcase or some other enclosed space, be sure to provide adequate ventilation.
2. Put your medical LCD monitor in a location with low humidity and a minimum of dust.
3. Do not expose the medical LCD monitor to rain or use it near water (in kitchens, near swim-
ming pools, etc.). If the medical LCD monitor accidentally gets wet, unplug it and contact an
authorized dealer immediately. You can clean the medical LCD monitor with a damp cloth if
necessary, but be sure to unplug the medical LCD monitor rst.
4. Place your medical LCD monitor near an easily accessible AC outlet.
5. High temperature can cause problems. Don’t use your medical LCD monitor in direct sunlight
and keep it away from heaters, stoves, replaces,and sources of heat.
6. Don’t place your medical LCD Monitor on an unstable stand, Medical LCD monitor may mal-
function or fall.
7. This medical LCD monitor should not topple over when tilted at a 5° angle, in any position,
during NORMAL USE, excluding transport.
8. In the position specied for transport, medical LCD monitor shall not overbalance when tilted
at a 10 degree angle.
9. When carrying this product, please use both handles (if included) on the left and right side of
the product, and carry using two people. If you want the product to be installed in another
place, please call your service center.
10. Do not use other cables or accessories that are not provided.
11. Do not lay this monitor on the other equipment.
Environmental Conditions for Operation and Storage
Temperature range within 0°C to 40°C(operation), -20°C to 60°C (storage)
Relative humidity range 10% to 85%
Atmospheric pressure range within 500 to 1060hPa.
Intended Use
This Medical LCD Monitor is an accessory intended for use with Medical Equipment to display
alphabetical, numerical and graphical data.

FSN1986 - 11/2017
8 - English
Cautions
Caution
CAUTION
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
This symbol alerts the user that important literature concerning the operation of this unit
has been included. Therefore, it should be read carefully in order to avoid potential problems.
This symbol warns users that un-insulated voltage within the unit may have sucient
magnitude to cause electrical shock. Therefore, it is dangerous to make contact with any part
inside the unit. To reduce the risk of electrical shock, DO NOT remove cover (or back). There are
no user-serviceable parts inside. Refer servicing to qualied service personnel.
To prevent re or shock hazards, do not expose this unit to rain or moisture. Do not use this unit’s
polarized plug with an extension cord receptacle or other outlets unless the prongs can be fully
inserted. This display is designed to meet the medical safety requirements for a patient vicinity
device. This device may not be used in connection with life support equipment.
Underwriters Laboratories (UL) Classication:
UL safety Compliance:
This medical LCD monitor is U.L. Classied WITH RESPECT TO ELECTRIC SHOCK, FIRE AND ME-
CHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 60601-1/CAN/CSA C22.2 NO. 601.1
EEC Safety Compliance:
This medical LCD monitor unit meets the requirements of EN-60601-1 so as to conform to the
Medical Device Directive 93/42/EEC (general safety information). Use 120V rating 5-15P type plug
only in the U.S.
This medical LCD monitor complies to the above standards only when used with the supplied
medical grade power supply.
FS-P2404D - BM120S24F02
FS-P2604D - ATM160T-P240
Caution: Make sure the power cord is the correct type that is required in your area. This medical
LCD monitor has a universal power supply that allows operation in either 100-120V AC or 200-
240V AC voltage areas (no user adjustment is required).
Use the proper power cord with correct attachment plug type. If the power source is 120 V AC,
use a power cord which is a Hospital Grade Power Cord with NEMA 5-15 style plug, labeled for
125 volts AC with UL and C-UL approvals. If the power source is a 240 V AC supply, use the tan-
dem (T blade) type attachment plug with ground conductor power cord that meets the respec-
tive European country’s safety regulations.

FSN1986 - 11/2017 English - 9
The hospital-grade plug for medical products intended for use in Denmark has DEMKO approval
and is rated 13 amps at 250Vac. Plug is recommended for use in medical applications and specica-
tions are being added to the standard SB 107-2-D1. Plug mates with maker’s Danish hospital-grade
socket. Hospital sockets have slightly dierent shaped openings allowing only the hospital plug, not
the standard Danish plug, to be inserted, to protect the ac circuit in specic medical settings.
A ground post, located on the back of the display, may be used for the purpose of grounding
the display’s chassis. Any such ground must be installed in accordance with applicable electrical
codes. The ground post is shown on the mechanical drawing found in this user’s guide.
Recycling
Follow local governing ordinances and recycling plans regarding the recycling or disposal of this
equipment.
Cleaning Instructions
Follow your hospital protocol for the handling of blood and body uids. Clean the display
with a diluted mixture of mild detergent and water. Use a soft cotton towel or swab.
Use of
certain detergents may cause degradation to the labels and plastic components of the product.
Consult cleanser manufacturer to see if agent is compatible. Do not allow liquid to enter the display.
Servicing
Do not attempt to service the medical LCD monitor yourself, as opening or removing covers may
expose you to dangerous voltages or other hazards, and will void the warranty. Refer all servicing
to qualied service personnel. Unplug the medical LCD monitor from its power source and refer
servicing to qualied personnel under the following conditions:
- If the power cord or plug is damaged or frayed.
- If liquid has been spilled into the medical LCD monitor.
- If objects have fallen into the medical LCD monitor.
- If the medical LCD monitor has been exposed to rain or moisture.
- If the medical LCD monitor has been subjected to excessive shock by being dropped.
- If the cabinet has been damaged.
- If the medical LCD monitor seems to be overheated.
- If the medical LCD monitor emits smoke or abnormal odor.
- If the medical LCD monitor fails to operate in accordance with the operating instructions.
Accessories
Use only accessories specied by the manufacturer, or sold with the medical LCD monitor.
Classication
- Protection against electric shock : Class I including AC/DC Adapter
- Applied Parts : No Applied Parts
- Degree of safety in the presence of ammable anesthetics mixture with air or with oxygen or
with nitrous oxide. Not suitable for use in the presence of a ammable anesthetics mixture with
oxygen or with nitrous oxide.
- Mode of operation : Continuous.

FSN1986 - 11/2017
10 - English
This medical LCD monitor unit has been tested and found to comply with the limits of a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reason-
able protection against interference. This monitor can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, it may interfere with other radio com-
munications equipment. There is no guarantee that interference will not occur in a particular
installation. If this equipment is found to cause harmful interference to radio or television recep-
tion, the user is encouraged to try to correct the interference by carrying out one or more of the
following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the distance between the medical LCD monitor and the subject of interference.
3. Plug the monitor into an outlet on a dierent electrical circuit than that to which the subject of
interference is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
NOTICES TO USER
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interfer-
ence received, including interference that may cause undesired operation.
FCC WARNING
This medical LCD monitor generates or uses radio frequency energy. Changes or modications
to this medical LCD monitor may cause harmful interference unless the modications are ex-
pressly approved in the instruction manual. The user could lose authority to operate this equip-
ment if an unauthorized change or modication is made.
PRODUCT LIFETIME
The average lifespan of this LCD monitor has been determined to be approximately 5 years, con-
sidering the LCD at panel which has been specied with a lifetime of 50,000 hours.
FCC Information

FSN1986 - 11/2017 English - 11
1. Guidance and manufacturer’s declaration - electromagnetic emission
The medical LCD monitor is intended for use in the electromagnetic environment specied below. The
customer or the user of the medical LCD monitor should assure that it is used in such an environment.
Emission test Compliance Electromagnetic environment -guidance
RF Emissions
CISPR 11 Group 1
The medical LCD monitor uses RF energy only for its internal
function. Therefore, its RF emissions are very low and are not
likely to cause any interference in nearby electronic equipment.
RF Emissions
CISPR 11 Class B
The medical LCD monitor is suitable for use in all establish-
ments, including domestic establishments and those directly
connected to the public low-voltage power supply network
that supplies buildings used for domestic purposes.
Harmonic emissions
IEC 61000-3-2 D
Voltage uctuations
IEC 61000-3-3 Complies
2. Guidance and manufacturer’s declaration - electromagnetic immunity
This medical LCD monitor is intended for use in the electromagnetic environment specied below.
The customer or the user of the medical LCD monitor should assure that it is used in such an environment.
Immunity test IEC 60601 Test
level
Compliance
level
Electromagnetic environment-guidance
Electrostatic
discharge(ESD)
IEC 61000-4-2
6 kV contact
8 kV air
6 kV contact
8 kV air
Floors should be wood, concrete or
ceramic tile. If oors are covered with
synthetic material, the relative humidity should
be at least 30%
Electrical fast
transient/burst
IEC 61000-4-4
2 kV for power
supply lines
1 kV for input/
output lines
2 kV for power
supply lines
1 kV for input/
output lines
Main power quality should be that of a typical
commercial or hospital environment.
Surge
IEC 61000-4-5
1 kV dierential mode
2 kV common mode
1 kV dierential mode
2 kV common mode
Main power quality should be that of a typical
commercial or hospital environment.
Conducted RF
IEC 61000-4-6
3 Vrms
150 kHz to
80MHz
3 Vrms
150 kHz to
80MHz
Portable and mobile RF communications equip-
ment should be used no closer to any part of
the LCD monitor, including cables, than the
recommended separation distance calculated
from the equation applicable to the frequency
of the transmitter.
Recommended separation distance : d
݀ൌ
͵ǡͷ
ܸଵ൨ξܲ
Where Pis the maximum output power rating of
the transmitter in watts (W)

FSN1986 - 11/2017
12 - English
3. Guidance and manufacturer’s declaration - electromagnetic immunity
This medical LCD monitor is intended for use in the electromagnetic environment specied below.
The customer or the user of monitor should assure that it is used in such an environment.
Immunity test IEC 60601 Test
level
Compliance level
Electromagnetic environment-guidance
Power frequency
(50/60Hz)
Magnetic eld
IEC 61000-4-8
3.0 A/m 3.0 A/m
Power frequency magnetic elds should be
at levels characteristic of a typical location in
a typical commercial or hospital
environment.
Voltage dips,
short Interrup-
tions and voltage
variations on
power supply
input lines
IEC 61000-4-l 1
<5% UT(>95% dip in
UT) for 0.5 cycle
40% UT(60% dip in UT)
for 5 cycle
70% UT(30% dip in UT)
for 25 cycle
<5% UT(<95% dip in
UT) for 5 sec.
<5% UT(>95% dip in
UT) for 0.5 cycle
40% UT(60% dip in UT)
for 5 cycle
70% UT(30% dip in UT)
for 25 cycle
<5% UT(<95% dip in
UT) for 5 sec.
Main power quality should be that of a
typical commercial or hospital environment.
If the user of monitor requires continued
operation during power mains interruptions,
it is recommended that monitor be powered
from an uninterruptible power supply or a
battery.
Note: UTis the A.C. mains voltage prior to
application of the test level.
Radiated RF
IEC 61000-4-3
3 V/m
80.0 MHz to 2.5
GHz
3 V/m
80.0 MHz to 2.5
GHz
Recommended separation distance
݀ൌ
͵ǡͷ
ܧଵ൨ξܲ80MHz to
800MHz
݀ൌ
ܧଵ൨ξܲ80MHz to
2.5GHz
Where Pis the maximum output power rat-
ing of the transmitter in watts (W) according
to the transmitter manufacturer and dis the
recommended separation distance in meters
(m). Field strengths from xed RF transmit-
ters, as determined by an electromagnetic
site survey, should be less than the compli-
ance level in each frequency range.

FSN1986 - 11/2017 English - 13
4. Recommended separation distances between portable and mobile RF
communications equipment and this medical LCD monitor.
The medical LCD monitor is intended for use in an electromagnetic environment in which radi-
ated RF disturbances are controlled. The customer or the user of the monitor can help prevent
electromagnetic interference by maintaining a minimum distance between portable and mobile
RF communications equipment (transmitters) and the medical LCD monitor as recommended
below, according to the maximum output power of the communications equipment.
Rated maximum
output power [W]
of transmitter
Separation distance according to frequency of transmitter[m]
150kHz to 80MHz
݀ൌ
͵ǡͷ
ܸଵ൨ξܲ
80MHz to 800MHz
݀ൌ
͵ǡͷ
ܧଵ൨ξܲ
800MHz to 2.5GHz
݀ൌ
ܧଵ൨ξܲ
V1=3Vrms E1=3V/m
E1=3V/m
0.01 0.116 0.116
0.2333
0.1 0.368 0.3687 0.7378
1 1.166 1.1660 0.2333
10 3.687 3.6872 0.7375
100 11.660 11.6600 23.333
For transmitters rated at a maximum output power not listed above, the recommended separation dis-
tance (d) in meters (m) can be estimated using the equation applicable to the frequency of the transmitter,
where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter
manufacturer.
Note 1) At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
Note 2) These guidelines may not apply in all situations. Electromagnetic propagation is aected by ab-
sorption and reection from structures, objects and people.

FSN1986 - 11/2017
14 - English
Parts
Monitor
FS-P2404D
FS-P2604D
Accessories
User Manual AC-DC Adaptor
FS-P2404D - BM120S24F02
FS-P2604D - ATM160T-P240
(6.23ft/1.9m)
AC Power Cord
(6ft/1.8/m US,UK,EU, China)
(Hospital Grade)
DVI-D Cable
(6ft/1.8m)
BNC Cable
(6ft/1.8m)
DC Cable Terminal
Male / female
(available for purchase)
D-SUB Cable
(6ft/1.8m)
(available for purchase)
Screw BH M4 x 14

FSN1986 - 11/2017
DVI 2 IN
(optional)
DVI 2 IN
(optional)
English - 15
Connectors
24” FS-P2404D
26” FS-P2604D
Power Management
This monitor saves energy by switching into a low power mode when it has not been used for a
certain period of time. Normal operation automatically returns to the monitor when horizontal
and vertical sync return.
State Normal
Operation DPMS standby DPMS suspend Power o
(OSD button)
Power o
(DC switch)
Horizontal Sync Active Inactive Active Inactive Inactive
Vertical Sync Active Active Inactive Inactive Inactive
Video Active Blanked Blanked Blanked Blanked
Power Indicator O Blue Flashing
(1 sec. interval)
Blue Flashing
(1 sec. interval) Blue O
Power Consumption
FS-P2404D
FS-P2604D
≤ 55W
≤ 65W
≤ 0.5W
≤ 0.5W
≤ 0.5W
≤ 0.5W
≤ 0.5W
≤ 0.5W
≤ 0.5W
≤ 0.5W

FSN1986 - 11/2017
575.4 mm / 22.66 in.
82 / 3.23
392
15.43
35.7
1.41
171.5
6.75
100
3.94
4-M4
VESA MOUNT
HOLES
100 / 3.94
16 - English
Mechanical Product Drawing
24” FS-P2404D Dimension

FSN1986 - 11/2017
640 mm / 25.20 in.
78 / 3.07
402
15.83
31.7
1.25
171.2
6.74
100
3.94
100 / 3.94
8-M4
VESA MOUNT
HOLES 200 / 7.87
English - 17
Mechanical Product Drawing
26” FS-P2604D Dimension

FSN1986 - 11/2017
18 - English
Controls
On Screen Display (OSD) Touchscreen
Touchscreen icons, located in bottom right corner of the LCD display, allows
the user to make adjustments to various display parameters using the On Screen Dis-
play (OSD) system. Slightly touch any icon to activate all of the icons.
QUICK ADJUST. Press
to decrease the display
contrast. No need to
enter the OSD main
menu.
When the OSD menu
is activated, press to
decrease the adjustment
of the selected function.
QUICK ADJUST. Press
to decrease the display
brightness. No need
to enter the OSD main
menu.
When the OSD menu is
activated, press to move
the menu selection
downward.
Press to enable PIP (Pic-
ture in Picture) function.
Select from:
PIP
PBP1
PBP2
Press to turn power on/
o to the display’s front
LCD screen.
If this icon is not illumi-
nated, then the power
switch on the back of
the display has been
turned o.
Press to show the input
selection menu and
to change the display
signal source.
Input choices:
DVI1, DVI2, DSUB Ana-
log, SDI, YPbPr, RGBS,
S-Video, C-Video.
Press 1 second for DSUB
Analog auto adjustment.
QUICK ADJUST. Press to
increase the display con-
trast. No need to enter
the OSD main menu.
When the OSD menu is
activated, press to enter
sub menu, or increase
the adjustment of the
selected function.
QUICK ADJUST. Press
to increase the display
brightness. No need
to enter the OSD main
menu.
When the OSD menu is
activated, press to move
the menu selection
upward.
Press to activate the
OSD menu.
When the OSD menu
is active, press to exit
from the main menu or
submenu.

FSN1986 - 11/2017 English - 19
On Screen Display (OSD) Input Source Select
FSN display monitors are compatible with many dierent types of video input signals. To view
and select a signal type, follow the steps below.
1. Enter the Input Source Select Menu
To activate, press the input button.
2. Pick a Video Source to Display
After entering the OSD, use the UP and DOWN buttons on the front of the display monitor
to navigate to the desired input video source type.
3. Activate the Input Source
After using the UP and DOWN buttons to navigate to the desired input video source type,
press the +button to display the active signal.

FSN1986 - 11/2017
20 - English
On Screen Display (OSD) Menus
FSN display monitors come equipped with a rich set of features for system set-up, image
adjustments, and screen layout control. These features are managed through the On Screen
Display, or OSD. Some options presented in the OSD are contextual and vary depending on the
active input signal. See the Controls section for a complete description of each OSD button.
1. Enter the OSD
To activate the OSD menu, press the MENU
button on the front of the display monitor. To
close the OSD menu, press the menu button to
exit from the main menu or a sub menu.
2. Pick a Main Menu Category
After entering the OSD, use the UP and DOWN buttons on the front of the display monitor
to navigate to a main menu category.
The ADJUST menu controls brightness, contrast, and more.
The COLOR SETTING menu controls preset or customized color settings.
The IMAGE menu controls horizontal / vertical positioning and sharpness.
The SETUP menu controls language, OSD behavior, and more.
The PIP menu controls picture in picture layouts.
3. Pick a Submenu Category
After using the UP and DOWN buttons to navigate to the desired main menu category,
press the +button to enter the submenus associated with the selected main menu.
This manual suits for next models
4
Table of contents
Other FSN Monitor manuals