FSN FM-A2701D User manual

Medical Display
FM-A2701D, FM-A2701DS
FM-B2702D, FM-B2702DG
User’s Guide
Before connecting, operating or adjusting this product, please
read this instruction booklet carefully and completely.

FSN2006 - 4/2019
2 - English
Table of Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Symbol Denitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
FCC Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16, 18
Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17, 19
Mechanical Drawing . . . . . . . . . . . . . . . . . . . . . . . . . 20, 21
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22, 23
Window Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24, 25
On Screen Display (OSD) . . . . . . . . . . . . . . . . . . . . . . 26-28
Standard Signal Tables. . . . . . . . . . . . . . . . . . . . . . . . . . 29
Signal Connector Pin Assignments . . . . . . . . . . . . . . . . 30-32
General Specication . . . . . . . . . . . . . . . . . . . . . . . . 33, 34
Cleaning Instructions . . . . . . . . . . . . . . . . . . . . . . . . 35, 36
The specications and information in this document are subject to change without notice.

FSN2006 - 4/2019 English - 3
Overview
FM-A2701D, FM-A2701DS
FM-B2702D, FM-B2702DG
This product from FSN Medical Technologies is a high-end surgical display monitor designed for
advanced digital OR applications. This medical display is uniquely equipped to handle tasks in
the demanding operating room environment. This unit features LED backlight technology.
We have implemented methods to ne-tune the properties of FSN displays. Distinct color space
settings have been calibrated to well-known surgical color preferences, providing the user with
the ideal surgical visualization system. Features include:
• Rapid signal detection, robust mode tables
• Artifact-free 4K UHD images
• Fanless - sterile eld compatible
• Calibrated to clinical color
• Image pan, zoom, freeze, picture-in-picture
FSN Medical Technologies has solutions for managing your operating room video signals. Our
products are engineered and built for compatibility with other highly specialized surgical and
diagnostic equipment used in surgical suites, operating rooms, emergency rooms, and proce-
dural facilities.

FSN2006 - 4/2019
4 - English
Symbol Denitions
The following symbols appear on the product, its labeling, or the product packing. Each symbol
carries a special denition, as dened below:
Dangerous : High Voltage Power adapter
Direct Current lndicates equipotential earth
ground
Indicates protective earth
ground
Indicates top-bottom
direction
DC Power control switch Fragile
Do not get wet Maximum Stacking
Consult the operating instruc-
tions.
Indicates the
manufacturer
Indicates the
manufacturing date
Authorized representative in
the European community
Serial Number Humidity limitation
Temperature limitation Atmospheric pressure
limitation

FSN2006 - 4/2019 English - 5
Indicates proof of conformity to applicable European Economic Community
Council directives and to harmonized standards published in the ocial journal
of the European Communities.
Medical Equipment is in accordance with ANSI/AAMI ES60601‐1 (2005) + AMD
1 (2012) and CAN/CSA‐C22.2 No. 60601‐1 (2014) in regards to electric shock,
re hazards, and mechanical hazard.
Tested to comply with FCC Class B standard.
This symbol indicates that the waste of electronic equipment must not be
disposed as unsorted municipal waste and must be collected separately. Please
contact the manufacturer or other authorized disposal company to
decommission your equipment.
Language: English
Note: A printed copy of the manual in English is provided with the product. Users within EU
member states, please contact local distributor for other languages or refer to the CD manual
enclosed with the product. This applies to EU member states where the product has been pur-
chased through authorized channels.

FSN2006 - 4/2019
6 - English
Safety Instructions
On Safety
1. Before connecting the AC power cord to the DC adapter outlet make sure the voltage desig-
nation of the DC adapter corresponds to the local electrical supply.
2. Never insert anything metallic into the cabinet openings of the medical LCD monitor. Doing
so may create the danger of electric shock.
3. To reduce the risk of electric shock, do not remove cover. No user-serviceable parts inside.
Only a qualied technician should open the case of the medical LCD monitor.
4.
Never use your medical LCD monitor if the power cord has been damaged. Do not allow anything
to rest on the power cord, and keep the cord away from areas where people can trip over it.
5. Be sure to hold the plug, not the cord,when disconnecting the medical LCD monitor power
cord from an electric socket.
6. Unplug your medical LCD monitor power cord when it is going to be left unused for an ex-
tended period of time.
7. Unplug your medical LCD monitor power cord from the AC outlet before any service.
8.
If your medical LCD monitor does not operate normally, in particular, if there are any unusual sounds
or smells coming from it, unplug it immediately and contact an authorized dealer or service center.
9. Please contact the manufacturer if the set should be installed in an inaccessible area.
Warning: Do not touch input or output connectors and the patient simultaneously.
Warning: This medical LCD monitor is intended for connection to input/output signals and other
connectors that comply with relevant IEC standard (e.g.,IEC60950 for IT equipment and IEC60601
series for medical electrical equipment). In addition, all such combination-system shall comply
with the standard IEC 60601-1-1 or clause 16 of the 3 Ed. of IEC 60601-1, respectively, safety re-
quirements for medical electrical systems. Any person who has formed a combination-system is
responsible for the system to comply with the requirements of IEC 60601-1-1 or clause 16 of the 3
Ed. of IEC 60601-1, respectively. If in doubt, contact qualied technician or your local representative.
Warning: To avoid risk of electric shock, this equipment must only be connected to a supply
mains with protective earth. Power supply (AC/DC Adapter) is specied as a part of the LCD Color
Display. Do not to position equipment so that it is dicult to disconnect the power cord plug
from the appliance inlet.
Warning: Do not modify this equipment without authorization of the manufacturer.
Product fuse has a lower breaking capacity. Do not install at the building power system, prospec-
tive short-circuit current exceeding 35 A.

FSN2006 - 4/2019 English - 7
On installation
1. Openings in the medical LCD monitor cabinet are provided for ventilation. To prevent over-
heating, these openings should not be blocked or covered. If you put the medical LCD moni-
tor in a bookcase or some other enclosed space, be sure to provide adequate ventilation.
2. Put your medical LCD monitor in a location with low humidity and a minimum of dust.
3. Do not expose the medical LCD monitor to rain or use it near water (in kitchens, near swim-
ming pools, etc.). If the medical LCD monitor accidentally gets wet, unplug it and contact an
authorized dealer immediately. You can clean the medical LCD monitor with a damp cloth if
necessary, but be sure to unplug the medical LCD monitor rst.
4. Place your medical LCD monitor near an easily accessible AC outlet.
5. High temperature can cause problems. Don’t use your medical LCD monitor in direct sunlight
and keep it away from heaters, stoves, replaces,and sources of heat.
6. Don’t place your medical LCD Monitor on an unstable stand, Medical LCD monitor may mal-
function or fall.
7. This medical LCD monitor should not topple over when tilted at a 5° angle, in any position,
during NORMAL USE, excluding transport.
8. In the position specied for transport, medical LCD monitor shall not overbalance when tilted
at a 10 degree angle.
9. When carrying this product, please use both handles (if included) on the left and right side of
the product, and carry using two people. If you want the product to be installed in another
place, please call your service center.
10. Do not use other cables or accessories that are not provided.
11. Do not lay this monitor on the other equipment.
Environmental Conditions for Operation and Storage
Temperature range within 0°C to 40°C(operation), -20°C to 60°C (storage)
Relative humidity range 10% to 85%
Atmospheric pressure range within 500 to 1060hPa.
Intended Use
This Medical LCD Monitor is an accessory intended for use with Medical Equipment to display
alphabetical, numerical and graphical data.

FSN2006 - 4/2019
8 - English
Cautions
Caution
CAUTION
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
This symbol alerts the user that important literature concerning the operation of this unit
has been included. Therefore, it should be read carefully in order to avoid potential problems.
This symbol warns users that un-insulated voltage within the unit may have sucient
magnitude to cause electrical shock. Therefore, it is dangerous to make contact with any part
inside the unit. To reduce the risk of electrical shock, DO NOT remove cover (or back). There are
no user-serviceable parts inside. Refer servicing to qualied service personnel.
To prevent re or shock hazards, do not expose this unit to rain or moisture. Do not use this unit’s
polarized plug with an extension cord receptacle or other outlets unless the prongs can be fully
inserted. This display is designed to meet the medical safety requirements for a patient vicinity
device. This device may not be used in connection with life support equipment.
Underwriters Laboratories (UL) Classication:
UL safety Compliance:
This medical LCD monitor is U.L. Classied WITH RESPECT TO ELECTRIC SHOCK, FIRE AND ME-
CHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 60601-1/CAN/CSA C22.2 NO. 601.1
EEC Safety and EMC Compliance:
This medical LCD monitor unit meets the requirements of EN60601-1 and EN60601-1-2 so as to
conform to the Medical Device Directive 93/42/EEC.
This medical LCD monitor complies to the above standards only when used with the supplied
medical grade power supply. Use 120V rating 5-15P type plug only in the U.S.
ATM160T-P240
Caution: Make sure the power cord is the correct type that is required in your area. This medical
LCD monitor has a universal power supply that allows operation in either 100-120V AC or 200-
240V AC voltage areas (no user adjustment is required).
Use the proper power cord with correct attachment plug type. If the power source is 120 V AC,
use a power cord which is a Hospital Grade Power Cord with NEMA 5-15 style plug, labeled for
125 volts AC with UL and C-UL approvals. If the power source is a 240 V AC supply, use the tan-
dem (T blade) type attachment plug with ground conductor power cord that meets the respec-
tive European country’s safety regulations.

FSN2006 - 4/2019 English - 9
The hospital-grade plug for medical products intended for use in Denmark has DEMKO approval
and is rated 13 amps at 250Vac. Plug is recommended for use in medical applications and speci-
cations are being added to the standard SB 107-2-D1. Plug mates with maker’s Danish hospital-
grade socket. Hospital sockets have slightly dierent shaped openings allowing only the hospital
plug, not the standard Danish plug, to be inserted, to protect the ac circuit in specic medical
settings.
A ground post, located on the back of the display, may be used for the purpose of grounding
the display’s chassis. Any such ground must be installed in accordance with applicable electrical
codes. The ground post is shown on the mechanical drawing found in this user’s guide.
Recycling
Follow local governing ordinances and recycling plans regarding the recycling or disposal of this
equipment.
Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided
because it could result in improper operation. If such use is necessary, this equipment and the
other equipment should be observed to verify that they are operating normally.
Warning: Use of accessories, transducers and cables other than those specied or provided
by the manufacturer of this equipment could result in increased electromagnetic emissions or
decreased electromagnetic immunity of this equipment and result in improper operation.
Warning: Portable RF communications equipment (including peripherals such as antenna cables
and external antennas) should be used no closer than 30 cm (12 inches) to any part of this medi-
cal LCD monitor, including cables specied by the manufacturer. Otherwise, degradation of the
performance of this equipment could result.
Warning: Failure to use this equipment in the X-ray or magnetic resonance environment could
result in degradation of the performance of this equipment, interference with other equipment
or interference with radio services.
Warning: This equipment has been tested for radiated RF immunity only at selected frequencies,
and use nearby of emitters at other frequencies could result in improper operation.
Warning: This product is not considered physically to connect to HF (High Frequency) electrosur-
gical equipment.

FSN2006 - 4/2019
10 - English
Cleaning Instructions
Follow your hospital protocol for the handling of blood and body uids. Clean the display
with a diluted mixture of mild detergent and water. Use a soft cotton towel or swab. Use of
certain detergents may cause degradation to the labels and plastic components of the product.
Consult cleanser manufacturer to see if agent is compatible. Do not allow liquid to enter the
display.
Servicing
Do not attempt to service the medical LCD monitor yourself, as opening or removing covers may
expose you to dangerous voltages or other hazards, and will void the warranty. Refer all servicing
to qualied service personnel. Unplug the medical LCD monitor from its power source and refer
servicing to qualied personnel under the following conditions:
- If the power cord or plug is damaged or frayed.
- If liquid has been spilled into the medical LCD monitor.
- If objects have fallen into the medical LCD monitor.
- If the medical LCD monitor has been exposed to rain or moisture.
- If the medical LCD monitor has been subjected to excessive shock by being dropped.
- If the cabinet has been damaged.
- If the medical LCD monitor seems to be overheated.
- If the medical LCD monitor emits smoke or abnormal odor.
- If the medical LCD monitor fails to operate in accordance with the operating instructions.
Accessories
Use only accessories specied by the manufacturer, or sold with the medical LCD monitor.
Classication
- Protection against electric shock : Class I including AC/DC Adapter
- Applied Parts : No Applied Parts
- Degree of safety in the presence of ammable anesthetics mixture with air or with oxygen or
with nitrous oxide. Not suitable for use in the presence of a ammable anesthetics mixture with
oxygen or with nitrous oxide.
- Mode of operation : Continuous.

FSN2006 - 4/2019 English - 11
This medical LCD monitor unit has been tested and found to comply with the limits of a Class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reason-
able protection against interference. This monitor can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, it may interfere with other radio com-
munications equipment. There is no guarantee that interference will not occur in a particular
installation. If this equipment is found to cause harmful interference to radio or television recep-
tion, the user is encouraged to try to correct the interference by carrying out one or more of the
following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the distance between the medical LCD monitor and the subject of interference.
3. Plug the monitor into an outlet on a dierent electrical circuit than that to which the subject of
interference is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
NOTICES TO USER
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
FCC WARNING
This medical LCD monitor generates or uses radio frequency energy. Changes or modications
to this medical LCD monitor may cause harmful interference unless the modications are ex-
pressly approved in the instruction manual. The user could lose authority to operate this equip-
ment if an unauthorized change or modication is made.
PRODUCT LIFETIME
The average lifespan of this LCD monitor has been determined to be approximately 5 years, con-
sidering the LCD at panel which has been specied with a lifetime of 50,000 hours.
FCC Information

FSN2006 - 4/2019
12 - English
1. Guidance and manufacturer’s declaration - electromagnetic emission
The medical LCD monitor is intended for use in the electromagnetic environment specied below. The user
of the device should make sure that the medical LCD monitor is operated in such an environment.
Interference emission measurements
Conformity level Electromagnetic environment -guidance
RF emissions acc. to CISPR 11 Complies with Group 1 The characteristics of this device determined
by broadcasting permit its industrial and
hospital use (CISPR 11, Class A). When used in a
living area (for which CISPR 11 usually requires
Class B), this device may not provide adequate
protection of radio services. The user must, if
necessary, take remedial action such as imple-
mentation or reorientation of the device.
RF emissions acc. to CISPR 11 Complies with Class B
Emission of harmonic oscilla-
tions acc. to IEC 61000-3-2 Complies with Class A
Voltage uctuations/icker
emissions acc. to IEC 61000-3-3 Complies
2. For the use of ME devices in professional healthcare facilities.
Guidance and manufacturer’s declaration - electromagnetic immunity
The medical LCD monitor is intended for use in the electromagnetic environment specied below.
The user of the medical LCD monitor should make sure that it is used in such an environment.
Interference
immunity test
IEC 60601-1-2:2014 con-
formity level
Electromagnetic environment-guidance
Electrostatic
discharge (ESD)
acc. to
IEC 61000-4-2
Complies ±2 kV, ±4 kV, ±6
kV, ± 8 kV contact discharge
±2 kV, ±4 kV, ±8 kV,
± 15 kV air discharge
Floors should be made of wood, concrete or ceramic tile.
If oors are covered with synthetic material, the relative
humidity must be at least 30%
Rapid transient elec-
tric interferences/
bursts acc. to
IEC 61000-4-4
Complies
± 2 kV for mains lines
± 1 kV for input/output lines
The quality of the supply voltage should correspond to
that of a typical business or hospital environment.
Surge acc. to
IEC 61000-4-5
Complies
± 1 kV push-pull voltage
± 2 kV common-mode
voltage
The quality of the supply voltage should correspond to
that of a typical business or hospital environment.
Voltage dips, short
interruptions and
uctuations of the
supply acc. to
IEC 61000-4-11
0 % UT*; 0.5 cycle
At 0°, 45°, 90°, 135°, 180°,
225°, 270°, 315°
0% UT; 1 cycle and
70% UT; 25/30 cycles
Single phase: at 0°
0% UT; 250/300 cycle
Mains power quality should be that of a typical commer-
cial or hospital environment.
If the user of the device requests continued functioning
even when interruptions of the power supply occur, it is
recommended that the device be supplied from a power
supply that is free of interruptions.
*Note: UTis the mains alternating voltage before applying the test levels.

FSN2006 - 4/2019 English - 13
3. For the use of ME devices in professional healthcare facilities.
Test specication for ENCLOSURE PORT IMMUNITY to RF wireless communica-
tions equipment (according to IEC 60601-1-2:2014)
The medical LCD monitor is intended for use in the electromagnetic environment specied below.
The user of the medical LCD monitor should make sure that it is used in such an environment.
Test fre-
quency
MHz
Band
MHz Service
Modulation
Maximum
power
W
Distance
m
IMMUNITY
TEST LEVEL
V/m
385 380 to 390 TETRA 400 Pulse modulation
18 Hz 1.8 1.0 27
450 430 to 470 GMRS 460,
FRS 460
FM
± 5 kHz stroke
± 1 kHz sine wave
2 1.0 28
710
704 to 787 Band 13, 17 Pulse modulation
217 Hz 0.2 1.0 9745
780
810
800 to 960
GSM 800/900
TETRA 800,
iDEN 820,
CDMA 850,
LTE Band 5
Pulse modulation
18 Hz 2 1.0 28870
930
1720
1700 to
1990
GSM 1800,
CDMA 1900,
GSM 1900,
DECT,
LTE Band 1,3,
4, 25 UMTS
Pulse modulation
217 Hz 2 1.0 281845
1970
2450 2400 to
2570
Bluetooth,
WLAN 802.11
b/g/n,
RFID 2450,
LTE Band 7
Pulse modulation
217 Hz 2 1.0 28
5240
5100 to
5800
WLAN 802.11
a/n
Pulse modulation
217 Hz 0.2 1.0 95500
5785
*Note: If necessary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting antenna
and the medical LCD monitor may be reduced to 1 m. The 1 m test distance is permitted by IEC 61000-4-3.

FSN2006 - 4/2019
14 - English
4. Guidance and manufacturer’s declaration – electromagnetic immunity – for
equipment and systems that are not life-supporting
The medical LCD monitor is intended for use in the electromagnetic environment specied below.
The user of the medical LCD monitor should make sure that it is used in such an environment.
Interference
immunity tests
IEC 60601-1-
2:2014 test level
Conformity
level
Electromagnetic environment – guidelines
Conducted RF
disturbances
acc. to
IEC 61000-4-6
Radiated RF
disturbances
according to
IEC 61 000·4·3
3 V rms
150 kHz to
< 80 MHz
3 V/m
80 MHz to
2.5 GHz
3 V e
3 V/m
Portable and mobile RF communications equip-
ment should be used no closer to any part of the
medical LCD monitor, including cables, than the
recommended separation distance calculated from
the equation applicable to the frequency of the
transmitter.
Recommended separation distance:
d = 1.2 P
Where P is the nominal power of the transmitter in
watts [W] according to the information provided
by the manufacturer of the transmitter and d is the
recommended separation distance in meters [m].
The eld strength of stationary transmitters at all
frequencies on site a should be, according to a
study, less than the conformity level b.
d = 1.2 P
80 MHz to < 800 MHz
d = 2.3 P
800 MHz to 2.5 GHz
Interference may occur in the vicinity of equipment
marked with the following symbol:
Note: These guidelines may not apply in all situations. The propagation of electromagnetic quantities is
aected by absorptions and reections of buildings, objects, and persons.
aField strengths from xed transmitters, such as base stations for radio [cellular/cordless] telephones and
land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted
theoretically with accuracy. To assess the electromagnetic environment of the stationary transmitters, a
site survey should be considered. If the measured eld strength in the location at which the device is used
exceeds the above conformity levels, the device should be observed to verify normal operation. If unusual
performance characteristics are observed, additional measures may be necessary, such as a modied
orientation or a dierent location for the device.
bOver the frequency range 150 kHz to 80 MHz, eld strengths should be less than 3 V/m.

FSN2006 - 4/2019 English - 15
5. Recommended separation distances between portable and mobile RF
communications equipment and the medical LCD monitor
The medical LCD monitor is intended for use in the electromagnetic environment in which the RF distur-
bances are controlled. The user of the device can help prevent electromagnetic interference by maintai-
ning a minimum distance between portable and mobile RF communications equipment (transmitters) and
the device – as a function of the output power of the communication device, as shown below.
Nominal power of
transmitter [W]
Separation distanced [m] according to frequency of transmitter
150kHz to< 80 MHz
d = 1.2 P
80 MHz to< 800 MHz
d = 1.2 P
800 MHz to 2.5 GHz
d = 2.3 P
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
For transmitters rated at a maximum output power not listed above, the recommended separation dis-
tance din meters (m) can be estimated using the equation applicable to the frequency of the transmitter,
where Pis the maximum output power rating of the transmitter in watts (W) according to the transmitter
manufacturer.

FSN2006 - 4/2019
27” FM-A2701DS
27” FM-A2701D
16 - English
Parts
Monitor
Accessories
User Manual AC-DC Adaptor
(6.23ft/1.9m)
AC Power Cord
(6ft/1.8/m US,UK,EU, China)
(Hospital Grade)
DisplayPort Cable
HDMI Cable SDI BNC Cable x 4
(FM-A2701DS)
Screw
BH M4 x 14
DVI-D Cable

FSN2006 - 4/2019
GROUND
DC IN RS232C GPIO HDMI
IN
DVI
IN
DVI
OUT
5V
OUT 1
DC ON/OFF
SWITCH
DISPLAY
PORT 1
OUT IN
USB
(SVC)
5V
OUT 2
DISPLAY
PORT 2 IN
GROUND
SDI 4
IN OUT
DC IN RS232C IN OUT
SDI 3
IN OUT
SDI 1
GPIO HDMI
IN
DVI
IN
DVI
OUT
5V
OUT 1
SDI 2
IN OUT
DC ON/OFF
SWITCH
DISPLAY
PORT 1
OUT IN
USB
(SVC)
5V
OUT 2
DISPLAY
PORT 2 IN
English - 17
Connectors
27” FM-A2701D Monitor Connector
27” FM-A2701DS Monitor Connector

FSN2006 - 4/2019
27” FM-B2702D
27” FM-B2702DG
18 - English
Parts
Monitor
Accessories
User Manual AC-DC Adaptor
(6.23ft/1.9m)
AC Power Cord
(6ft/1.8/m US,UK,EU, China)
(Hospital Grade)
DisplayPort Cable
HDMI Cable SDI BNC Cable x 4
(FM-B2702DG)
Screw
BH M4 x 14
DVI-D Cable

FSN2006 - 4/2019
3G SDI
12G SDI
GROUND RS232C
SDI 4
IN OUT
DC IN IN OUT
SDI 3
IN OUT
SDI 1
GPIO HDMI
IN
DVI
IN
DVI
OUT
5V
OUT 1
SDI 2
IN OUT
DISPLAY
PORT 1
OUT IN
USB
(SVC)
5V
OUT 2
DISPLAY
PORT 2 IN
GROUND RS232C
DC IN GPIO HDMI
IN
DVI
IN
DVI
OUT
5V
OUT 1
DISPLAY
PORT 1
OUT IN
USB
(SVC)
5V
OUT 2
DISPLAY
PORT 2 IN
English - 19
Connectors
27” FM-B2702D Monitor Connector
27” FM-B2702DG Monitor Connector

FSN2006 - 4/2019
FM-A2701DS
658.8 mm / 25.94 in.
426
16.77
60 / 2.36
25
.98
100
3.94
100 / 3.94
200 / 7.87
8-M4
VESA
20 - English
Mechanical Product Drawing
27” FM-A2701D, FM-A2701DS Dimension
Other manuals for FM-A2701D
1
This manual suits for next models
3
Table of contents
Other FSN Monitor manuals