Gaswinkel KF-001B User manual

READ INSTRUCTIONS CAREFULLY: READ AND FOLLOW ALL INSTRUCTIONS.
PLACE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE.
ONLY USE IN A WELL VENTILATED AREA
USER MANUAL
FOR
MOBILE GAS HEATR
(KF-001B / KF-001C)
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY. A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE. PERSONAL
INJURY OR LOSS OF LIFE

WARNING
1. Read the instructions before using this appliance.
2. Never attempt to light if the hose is loose or damaged in any way.
3. Do not cover the heater.
4. Never disconnect the regulator while cylinder valve or regulator is open.
5. Do not change cylinders in areas in which open fire exists.
6. Do not expose your cylinder to extreme heat.
7. Do not store any other cylinders in the room in which your heater is used.
8. Keep young children and animals away from the heater. Do not insert your finger or
any other material through the front panel of the heater.
9. Do not let unauthorized persons to tamper with your heater
10. Do not place appliance under electrical socket outlets.
11. This heater must not be used without a gas cylinder fitted for stability purposes.
12. Do not cover your heater. Fabrics, clothing, hangings, net curtains, bed linens and
other flammable materials may ignite if placed against the outlets of your heater.
13. In the event of leakage, the appliance should be turned off at cylinder valve and the
regulator disconnected from the cylinder. Call your gas supplier immediately.
14. After use turn off the appliance at the gas container valve.
15. This appliance requires a hose and a regulator, check with your gas supplier
16. Only use in well ventilated areas.
17. Do not use in vehicles, caravans or auto caravans.
18. Do not attempt to use in high-rise flats, basements, bathrooms or bedrooms.
19. This appliance should be tested for leaks before initial use and whenever the
cylinder is re-connected.
20. It is important that all gas connections have been correctly made to prevent any
leakage. Do not use naked flame to test for leaks. Use soapy water.
21. Always use your cylinder always in an upright position.
22. Always close the cylinder valve when the heater is not in use.
23. When lighting your heater for the first time or after a period of time has passed
since the last use, light the heater outside and burn outdoors for 15 minutes.
24. Do not use your heater while sleeping.
25. The guard on the appliance is to prevent risk of fire or injury form burns and no part
of it should be permanently removed. It does not give full protection for young
children or the infirm. We would recommend a fireguard to be fitted.
26. Do not move the heater and cylinder when in use.
1

27. Do not use it as clothes dryer.
USING ENVIRONMENT
Your heater consumes oxygen while it is in function. For that reason, adequate ventilation
should be provided in rooms in which the heater is used. This ensures the removal of
products of combustion and allows the entry of replacement air.
Adequate ventilation should considerably reduce the possibility of condensation occurring.
The following table shows the smallest sizes of room suitable for each heat setting and
the ventilation.
FOR INFRARED MODELS:
Number of radiant
continuously IN USE
ROOM SIZE
VENTILATION
Low level
High level
1
40 cubic metres - 4m*4m*2.5
40cm2
40cm2
2
70 cubic metres - 7m*4m*2.5
70cm2
70cm2
3
105 cubic metres - 105m*4m*2.5
105cm2
105cm2
Packing details:
When you receive a new heater, you will find the below parts inside the
carton:
1, one piece heater
2, two pieces legs
3, four pieces wheels
4, two pieces screws and one piece manual.
This heater is suitable for Floor stand and Wall mounted using.
So choose which style you want to use, and install the heater according to
the procedures.
A. Floor Stand Installation Procedures
1), install the legs and wheels according to the pictures Fig01
Push the wheels to legs first, then put the heater upside down, and install the
legs to the heater by turning the screws through the leg to heater before
using.
2), Connect the Hose, regulator and cylinder. See: Page 4 .
3), Place the cylinder at the back side of the heater. Fig 03
2

B. Wall Mounted Installation Procedures
Fig
02
Fig
03
Fig 04
Fig 05
Fig
01
01
02
03
3

HOW TO INSTALL THE HEATER
For convenience and efficiency, install the heater:
• Where there is easy access for operation,inspection, and service.
• In the coldest part of the room.
WARNING: Never install the heater in these places:
• In a bathroom.
• In a bedroom
• In a recreational vehicle .
• Where curtains, furniture, clothing, or other flammable objects are less than 200CM
from the front, 150CM from the top, or 75CM from the sides of the heater.
• As a fireplace insert
• In high-traffic areas
• In windy or drafty areas
• Do not place the heater facing to the cylinder, always place the cylinder at the back
side of the heater, and keep at least 50mm from the heater.
WARNING: Heater must be mounted to maintain
the minimum clearances shown in Fig 05. If possible, provide greater clearances from the
floor, ceiling, and joining walls.
FASTENING HEATER TO WALL
1. Mark the heater locations on the wall where heater will be located. Make sure heater is
level.
WARNING: Maintain minimum clearances shown in Fig 05. If you can, provide
greater clearances from the floor and joining wall.
2. Mark screw locations on wall (see Fig 07).
3. Drill holes at marked locations
4. Insert wall plug into hole. Tap wall plug flush to wall.
5. Drive the screws into the wall plug, and keep screws at 7mm out from the wall.
6. Make sure the screws are firmly fastened to wall.
7, Hang the heater brackets onto the screws. And make sure that the heater is firmly
installation.
4

CONSTRUCTION AND FUNCTION
1. Gas inlet connector
2. Wheel
3. Leg
4. Gas control knob
5. Piezo Ignition
6. Ignition handle
7. Burner
8. Safety Guard
9. Corner fixtor
10. Wall Mounted Bracket
10
Fig 06
Fig 07
5

CONNECTING THE CYLINDER
(a) Place the gas filled cylinder into the back of the heater
(b) Clip on the gas regulator to the gas cylinder (fit for 15kg gas cylinder)
(c) Turn the regulator on.
(d) Where the regulator is not supplied please contact your gas dealer to advise of
correct type for the gas cylinder being used.
(e) To avoid of twisting the hose,please make sure to connect the hose with
regulator and heater smoothly
(f) The length of hose not less than 50cm,PVC or Rubber type, comply with
BS3212-Class 2/EN1763-1-Class 3 / EN16436-1:2014+A3:2020
(g) IMPORTANT TEST FOR LEAKS:
This must be carried out in a well-ventilated area, free from naked flames and any
other sources of ignition. With the regulator connected to the cylinder turn on
the regulator control. Brush all hose connections, pipe connections to the valve
and gas cylinder valve with a 50:50 solution of detergent and water. A stream of
bubbles forming indicates a leak. If a leak is found turn off at the regulator and
disconnect the regulator from the bottle and remove the gas cylinder outdoors or
to a well ventilated area. Contact your gas supplier for assistance. DO NOT USE
THE HEATER.
(h) After leak testing is satisfactorily carried out close the back door of the heater.
It may be necessary to move the heater slightly to allow the regulator and hose
to fit in the back without kinking the hose
(i) Need to regular checking and if necessary replacement the hose
HOW TO CHANGE A CYLINDER
1) Unplug the heater before take out the cylinder.
2) Turn off at the regulator and allow the heater to cool fully before removing
and replacing the cylinder. Do not attempt to replace the cylinder whilst the
heater is still running.
3) Cylinders must be replaced in a flame free environment.
4) Do not smoke while changing the cylinder.
5) When you need to replace your empty cylinder, turn the gas off at the valve or
regulator of the cylinder and take the empty cylinder out of the heater.
6) Remove the regulator from the empty cylinder.
6

7) Following the steps described under “connecting the cylinder”, connect a
new cylinder
OPERATION GUIDE
LIGHTNG INSTUCTION, see Fig 08
A. The heater has three settings. Lighting/Min(Pos.1), Minimum (Pos.2); Medium
(Pos.3) and Maximum (Pos.4)
B. Place the gas filled cylinder into the back of the heater.
C. Clip on the gas regulator to the gas cylinder.
D. Turn on the gas regulator.
1. LIGHTING (please see the picture Fig 09)
Press the control button for 10 seconds at the Position 1, at the same time press the
Piezo igniter key to lit with thumb finger of right hand, Continue this procedure until
pilot ignites, approximately after 20 seconds leave Gas control Knob. At this stage if
the pilot is alight, If the pilot flame goes out please repeat this procedure. and then
turn the knob from Pos.1. to medium or Maximum power setting,
Pos. 1
(lighting/min)
Pos. 2
(Min)
Pos. 3
(Mid)
Pos. 4
(Max)
Fig 08
7

Fig 09
2. HEAT SETTINGS
To change from minimum to maximum gently press control button and turn it to
position 4.
To change from maximum to medium gently press control button and turn it to
position 3.
3. TURN OFF THE HEATER
Turn off the heater by the close the cylinder valve, and turn knob to “Lighting”
position(Pos.1)
Warning: The heater can be turned off at the cylinder valve ONLY.
If the heater is not used for a period of time, disconnect the regulator from the
cylinder and replace any value protection plug or cover.
STORAGE
1. Disconnect cylinder.
2. Store cylinder in a well-ventilated area away from combustible material. Storage
preferable be in an outhouse but must not be in a basement or high-rise flat.
3. The heater should be covered in a dry, dust-free area in its original packaging.
Piezo Ignition
Gas Control Knob
Ignition Handle
8

CLEANING
1. Use a damp soapy wrung cloth clean the exterior and cylinder storage area of your
heater.
2. Make sure that no water gets onto the burners or pilot/light area. Wipe the heater dry
before use.
3. Don’t use abrasive cleaners as they may damage the quality paint finish.
MAINTENANCE
1. Check flexible tubing between regulator and heater regularly and replace if perished,
worn or damaged. In any case replace tubing taking into consideration the expiration
date.
2. It is recommended that the heater be serviced every year by a competent person in
accordance with the Gas Safety (installations and use) Regulations 1998.
3. If any parts need replacing, they should be replaced only with the correct parts
supplied by the original manufacturer.
9

FAULT FINDING CHART
Technical
problems
Problem
Problem Causes
What To Do
Smell of gas
Regulator & hose connection
loose
Use soap form for leakage control,
check all connection system replace
defected parts
Valve & pipe connection loose
Pipe broken
Missing piece of ceramic
fireclay
Inspect perimeter of each plaque and
locate place where some fireclay has
been displaced. Repair with PYRUMA
and leave to set for Approx. 48 hours.
Inefficient combustion
on ceramic burner
Dirty gas inlets
Please clear injectors with Air
If there is no ignition
Defective Spark - Plug
Check cable of ignitor, & replace
defected ignitor if necessary
Defective ignitor cable
Check spark – plug and connections, &
replace defected ignitor if necessary
Burner flame has
extinguish during
operation
Run out of gas
Change the gas bottle
Thermal element has not been
warm enough
Try restarting
Wing or draught has
extinguished the flame
Put the appliance out of reach of wind
and draught, let it cool down for a couple
of minutes and try to restart it
Faulty thermocouple
Replace the faulty thermocouple
Faulty magnetic valve
Replace the magnetic valve
general
problem
Heater is not remain
alight when pressure is
released from ignition
button
Wrong power setting at first
process
Turn the control knob at “ START”
Position and press for 10 seconds,
whilst press the Piezo igniter key to lit
Heater could not be
turned on
Did not connect the gas
regulator to gas cylinder
Connect heater to the gas cylinder and
ensure there is not smell, then follow the
Instruction to turn on the heater
Gas cylinder control is closed
Please turn on the gas cylinder control
10

REPAIRS SHOULD ONLY BE CARRIED OUT BY A COMPETENT
PERSON IN ACCORDANCE WITH THE GAS SAFETY
(INSTALLATIONS AND USE) REGULATIONS 1998
Technical Data:
Manufacturer:
Broilfire BV.
Add: Gildenweg 2a –7021 BR Zelhem Holland; Tel: 0315 340 099 (Between
9.30 am und 15.30 pm)
2531DN-0006
Model
KF-001B, KF-001C
Product name
Gas Heater
Standard
EN 449-2002+A1-2007
Appliance
category
I3+
I3B/P(30)
I3B/P(50)
I3P
I3B/P(37)
Type of gas
G30
G31
G30
G31
G30
Gas Pressure
(mbar)
28-30
37
30
50
37
37
Injector’s
diameter(mm)
0.58
0.58
0.51
0.58
0.54
Destination
countries
BE, CH, CY,
CZ, ES, FR,
GB, GR,IE, IT,
LT,LU, LV, PT,
SI, SK, TR
BE, BG, CY,
CZ, DK, EE,
FI, FR, GB,
GR, HR, HU,
IT, LT, MT, NL,
NO, RO, SE,
SI, SK, TR
AT, CH,
DE, SK,
LU,
BE, CH, CZ,
ES, FR, GB,
GR, HR, IE,
IT, LT, NL,
PL, PT, SI,
SK
PL
Heat input (Hs)
KW(g/h)
4.2KW (305g/h)
Ignition
Pilot burner ignition
11
This manual suits for next models
1
Table of contents
Popular Gas Heater manuals by other brands

Brant Radiant Heaters
Brant Radiant Heaters QTS Series manual

Coleman
Coleman 5053 Instructions for use

Empire
Empire BF-10BC-2 Installation instructions and owner's manual

Desa
Desa FLAME-MAX VML27NR OWNER'S OPERATION AND INSTALLATION MANUAL

Astria
Astria Northern Oak27MN operating instructions

Pakole
Pakole ZENIT 70+ user manual

Desa
Desa Vanguard VVDR30 OWNER'S OPERATION AND INSTALLATION MANUAL

Desa
Desa Comfort Glow CGG3324N OWNER'S OPERATION AND INSTALLATION MANUAL

RealFlame
RealFlame CAPTIVA Installation & operating manual

Desa
Desa BLP35ES owner's manual

Primo Water
Primo Water NY-158A use instructions

Allied Air
Allied Air 506271-01 installation instructions