GE JD966 How to use

C
GE Consumer Service Training
TECHNICAL SERVICE GUIDE
C
PUB #
30-in. Electric
Drop-In/Slide-In Range
Drop-In
JD966
JDP46
31-9074 06/01
GE Consumer Home Services Training
Slide-In
JS966
JSP56
JSP46

IMPORTANT SAFETY NOTICE
The information in this service guide is intended for use by
individuals possessing adequate backgrounds of electrical,
electronic, and mechanical experience. Any attempt to repair a
major appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible for the
interpretation of this information, nor can it assume any liability in
connection with its use.
WARNING
To avoid personal injury, disconnect power before servicing this prod-
uct. If electrical power is required for diagnosis or test purposes,
disconnect the power immediately after performing the necessary
checks.
RECONNECT ALL GROUNDING DEVICES
If grounding wires, screws, straps, clips, nuts, or washers used to
complete a path to ground are removed for service, they must be
returned to their original position and properly fastened.
GE Consumer Home Services Training
Technical Service Guide
Copyright © 2001
All rights reserved. This service guide may not be reproduced in whole or in part
in any form without written permission from the General Electric Company.
!

1
Table of Contents
Table of Contents
Introduction ......................................................................................................... 2
Installation ........................................................................................................... 3
Specifications and Nomenclature5 .................................................................. 21
Warranty Information ......................................................................................... 22
Features and Controls ....................................................................................... 23
Mechanical Disassembly ................................................................................... 29
DiagnosticsX ...................................................................................................... 37
Component and Connector Locator Views ..................................................... 41
Schematics and Strip Circuits .......................................................................... 46
Parts List ............................................................................................................. 52
[[Title]]

2
Introduction
The new 30-in. Drop-In and Slide-In Electric
Ranges make an eloquent statement of style,
convenience, and kitchen planning flexibility. The
SmartSet Electronic Touch Controls are simple to
understand and easy to operate.Just read and
touch.
These ranges include many helpful features, such
as a specially designed touch-control panel that is
uniquely angled for optimal, user-friendly opera-
tion and a warming zone for very low-heat cook-
ing, preparing sauces, and keeping food warm
and ready to enjoy.The convection baking and
roasting feature provides even cooking and supe-
rior baking every time.
It’s easy to see how GE’s fresh ideas can make
anyone more creative in the kitchen!
New servicing features include front accessibility
to all components except the convection oven fan
motor and easy replacement access to the oven
door locking assembly.
The information on the following pages will help
you service these new 30-in. Drop-In and Slide-In
Electric Ranges effectively and efficiently.

3
Installation
Table of Contents
Safety Instructions.................................................................................................. 4
Cutout Dimensions and Required Clearances
Drop-In Range ................................................................................................. 5
Slide-In Range ................................................................................................. 6
Standard Installation Preparation.......................................................................... 7
Electrical Connections
Drop-In Range ................................................................................................. 8
Slide-In Range .................................................................................................11
Anti-Tip Bracket Installation
Drop-In Range .................................................................................................12
Slide-In Range .................................................................................................16
Final Check List.......................................................................................................19
Operation Check List ..............................................................................................19

4
$OOURXJKLQDQGVSDFLQJGLPHQVLRQVPXVWEHPHW
IRUVDIHXVHRI\RXUUDQJH(OHFWULFLW\WRWKHUDQJH
FDQEHGLVFRQQHFWHGDWWKHRXWOHWZLWKRXWPRYLQJ
WKHUDQJHLIWKHRXWOHWLVLQWKHSUHIHUUHGORFDWLRQ
UHPRYHORZHUGUDZHU
7RUHGXFHWKHULVNRIEXUQVRUILUHZKHQUHDFKLQJ
RYHUKRWVXUIDFHHOHPHQWVFDELQHWVWRUDJHVSDFH
DERYHWKHFRRNWRSVKRXOGEHDYRLGHG IFDELQHW
VWRUDJHVSDFHLVWREHSURYLGHGDERYHWKH
FRRNWRSWKHULVNFDQEHUHGXFHGE\LQVWDOOLQJD
UDQJHKRRGWKDWVWLFNVRXWDWOHDVW´EH\RQGWKH
IURQWRIWKHFDELQHWV&DELQHWVLQVWDOOHGDERYHD
FRRNWRSPXVWEHQRGHHSHUWKDQ´
%HVXUH\RXUDSSOLDQFHLVSURSHUO\LQVWDOOHGDQG
JURXQGHGE\DTXDOLILHGWHFKQLFLDQ
:$51,1*)RUSHUVRQDOVDIHW\
UHPRYHKRXVHIXVHRURSHQFLUFXLW
EUHDNHUEHIRUHEHJLQQLQJ
LQVWDOODWLRQ)DLOXUHWRGRVRFRXOGUHVXOWLQ
VHULRXVLQ XU\RUHYHQGHDWK
)RU<RXU6DIHW\
:$51,1*7RUHGXFHWKHULVNRI
WLSSLQJWKHDSSOLDQFHPXVWEH
VHFXUHGE\SURSHUO\LQVWDOOLQJWKH
DQWLWLSEUDFNHWSDFNHGZLWKWKHDSSOLDQFH
I\RXSXOOWKHUDQJHRXWDQGDZD\IURPWKHZDOO
IRUDQ\UHDVRQPDNHVXUHWKH$QWL7LSEUDFNHW
LVHQJDJHGZKHQWKHUDQJHLVSXVKHGEDFN
DJDLQVWWKHZDOO
7KLVDSSOLDQFHPXVWEHVXSSOLHGZLWKWKHSURSHU
YROWDJHDQGIUHTXHQF\DQGFRQQHFWHGWRDQ
LQGLYLGXDOSURSHUO\JURXQGHGEUDQFKFLUFXLW
SURWHFWHGE\DFLUFXLWEUHDNHURUIXVHKDYLQJ
DPSHUDJHDVVSHFLILHGRQWKHUDWLQJSODWH7KH
UDWLQJSODWHLVORFDWHGDERYHWKHVWRUDJHGUDZHU
RQWKHRYHQIUDPH
:HUHFRPPHQG\RXKDYHWKHHOHFWULFDOZLULQJ
DQGKRRNXSRI\RXUUDQJHFRQQHFWHGE\D
TXDOLILHGHOHFWULFLDQ$IWHULQVWDOODWLRQKDYHWKH
HOHFWULFLDQVKRZ\RXZKHUH\RXUPDLQUDQJH
GLVFRQQHFWLVORFDWHG
&KHFNZLWK\RXUORFDOXWLOLWLHVIRUHOHFWULFDOFRGHV
ZKLFKDSSO\LQ\RXUDUHD)DLOXUHWRZLUH\RXU
RYHQDFFRUGLQJWRJRYHUQLQJFRGHVFRXOGUHVXOWLQ
DKD]DUGRXVFRQGLWLRQ IWKHUHDUHQRORFDO
FRGHV\RXUUDQJHPXVWEHZLUHGDQGIXVHGWR
PHHWWKHUHTXLUHPHQWVRIWKH1DWLRQDO(OHFWULFDO
&RGH$16 1)3$1R/DWHVW(GLWLRQ<RXFDQ
JHWDFRS\E\ZULWLQJ
1DWLRQDO)LUH3URWHFWLRQ$VVRFLDWLRQ
%DWWHU\0DUFK3DUN
4XLQF\0$
(IIHFWLYH-DQXDU\WKH1DWLRQDO(OHFWULFDO
&RGHUHTXLUHVWKDWQHZEXWQRWH[LVWLQJ
FRQVWUXFWLRQXWLOL]HDFRQGXFWRUFRQQHFWLRQWR
DQHOHFWULFUDQJH:KHQLQVWDOOLQJDQHOHFWULF
UDQJHLQQHZFRQVWUXFWLRQIROORZWKHLQVWUXFWLRQV
LQWKHVHFWLRQRQ1(:&216758&7 21$1'
)285&21'8&725%5$1&+& 5&8 7
&211(&7 21
<RXPXVWXVHDWKUHHZLUHVLQJOHSKDVH$&
<9ROWRU9ROWKHUW]HOHFWULFDO
V\VWHP I\RXFRQQHFWWRDOXPLQXPZLULQJ
SURSHUO\LQVWDOOHGFRQQHFWRUVDSSURYHGIRUXVH
ZLWKDOXPLQXPZLULQJPXVWEHXVHG
(OHFWULFDO5HTXLUHPHQWV
WARNING
• All ranges can tip
• Injury to persons could result
• Install anti-tip bracket
packed with range
• See Installation Instructions
*
*On the Drop-In Range, the rating plate is located
behind the oven door.
Safety Instructions

5
Cutout Dimensions and Required Clearances
Drop-In Range

6
Cutout Dimensions and Required Clearances
Slide-In Range
Ifcabinetsareplacedlessthan30"abovethe
range,seealternateconstructionpage12.
NOTE:ProductmeetsULrequirementsfor0"
clearancetobackandsidewalls.
Wallcoverings,countersandcabinetsaround
rangemustwithstandheat(upto200˚F)
generatedbytherange.
31-1/4"
2-7/8"
To Front
Surface Of
Countertop
Door Clearance
From Front
Surface of
Countertop
20-5/8"
5-1/2" 19" 5-1/2"
29-15/16"MIN
30-1/16" MAX
23-3/16"
7"
Acceptable
Electrical
Outlet Area
30" Min.
30" Min.
from
cooking
surface to bottom
of overhead
cabinets
Shave Raised Edge
To Clear 31-1/8"
Wide Control Panel
6" Min.
FromWalls
9/16"
A
13"
Max.
depth
24"Min.
For Optimum
InstallationThese
Surfaces Must
Be Flat & Level
Max. depth of
cord, plug and
recpt. box
4" to prevent
interference
with drawer
Follow instructions
packaged with alternate
appliance.
Countertop
Depth 25"
35-1/2" to 36-1/2"
from floor to
countertop
15" Min. vertical
distance from the
bottom of the adjacent
overhead cabinets
GEA01050

7
IWKHFRQVWUXFWLRQRI\RXUFDELQHWFDQQRW
SURYLGHD´IODWDUHDEDFNRIWKHFRXQWHUWRS
RSHQLQJFRQVLGHUFKDQJLQJWKHFRXQWHUWRSWR
DFFRPRGDWHWKLVGLPHQVLRQ6HHDOWHUQDWH
FRQVWUXFWLRQVVHFWLRQ IWKHDUHDLVQRWIODW
H[FHVVWHQVLRQPD\EHDSSOLHGWRWKHJODVV
FDXVLQJEUHDNDJHDQGYRLGLQJWKHZDUUDQW\
%
5HPRYHFRXQWHUWRSUDLVHGHGJH I
LQFRUSRUDWHG6HHLOOXVWUDWLRQRQSDJH
&HQWHUWKH´ZLGHRSHQLQJRYHUWKH
DGMDFHQWFDELQHWVDQGPDUNZLWKD
VWUDLJKWHGJH
% 8VLQJDVWUDLJKWHGJHPDUNWKHEDFNOLQH
DW´IURPWKHIURQWHGJHRIWKH
FRXQWHU
% %HFDUHIXOQRWWRGDPDJHWKHDGMDFHQW
FDELQHWVZKLOHFXWWLQJWKHFRXQWHUWRS
8VHDKDQGRUVDEHUVDZWRPDNH
VWUDLJKWVPRRWKFXWV
%
1/4"
R
FLAT AREA
36"
23-3/16" 25"Typically
Standard Installation
29 -15/16 to 30 -1/16"
Smooth Cut
Wall
9/16" Min.
Flat
1/4" Min.
Flat
9/16" Min.
Flat
1/4"
R
FLAT AREA
Slide-In
Drop-In
Grounding Specifications
Ground Path Resistance 0.10 ΩMax.
Insulation Resistance 250K ΩMin.
36 in.
The Standard Installation of the Drop-In Range
is to hang by the countertop on the side metal
flanges under the glass cooktop. This Range
must not be installed on a base or sub structure.
If the construction of your cabinet cannot provide
a 1/4-in. flat area at the back of the countertop
opening, consider changing the countertop to
accomodate this dimension. If the area is not
flat, excess tension may be applied to the glass
cooktop causing breakage and voiding the
warranty.
Overcurrent Protection Ranges
Standard Installation Preparation
gnitaRCENgnitaRttawoliKmumixaM
pmA53
pmA04
pmA05
V802V632V042
-
4.21
4.71
4.21
4.51
4.12
4.21
0.61
0.22

8
Electrical Connections
Drop-In Range
Loosenscrewsforthejunctionbox
coverandrotateoutofplaceorremove
thecover.
C2
Examinethejunctionboxlocationand
determinethebestroutingoftheconduit
andselectthebestavailable7/8"
diameterknockout.Avoidusingholesin
thetopofthejunctionboxtopreventthe
conduitfrominterferingwiththebackof
therange.
C3
Breakopentheselectedknockoutby
placingabladedscrewdriveronthe
scoredopeninginthejunctionboxand
strikethescrewdriverwithahammer.
(Pliersmayberequiredtocompletethe
removaloftheknockout.)
Removehousefuseoropencircuit
breaker.
C4
WARNING:Improperconnectionof
aluminumhousewiringtocopper
leadscanresultinanelectrical
hazardorfire.Useonlyconnectors
designedforjoiningcoppertoaluminum
andfollowthemanufacturer's
recommendedprocedureclosely.
Feedwiresandconduitthroughtheopen
holeandsnaptheconduitfittingintothe
hole.Routetheconduitinamannerthat
willnotinterferewiththerearwirecover.
Theconduitmustberoutedbelowthe
wirecover.
C6
GENERALNOTEFORALLWIRENUT
APPLICATIONS:THEPROPERSIZEWIRE
NUTSHALLBEPLACEDOVERTHE
STRIPPEDLEADSANDTHEWIRENUT
TWISTEDUNTILTHEWIRENUTCANNOT
BEPULLEDFROMTHELEADS.NO
CONDUCTORSHALLBEEXPOSEDINTHE
CONNECTION.THEEXCEPTIONTOTHE
CONDUCTORBEINGEXPOSEDISTHE
BARECOPPERGROUNDCONNECTION.
7/8" Knock-out
Cover Rotated
from box Opening
Positiontherangeinfrontofthe
openingbutslightlytothesideina
mannerthatapersoncanenterthe
openingtowiretherangetothehouse
wiringinthejunctionbox.
C5
C1
GEA01049

9
7+5((&21'8&725%5$1&+
&,5&8,7&211(&7,21
:KHQFRQQHFWLQJWRDFRQGXFWRUEUDQFK
FLUFXLWLIORFDOFRGHVSHUPLW
&RQQHFWWKHEDUHRYHQJURXQG
FRQGXFWRUZLWKWKHFULPSHGQHXWUDO
ZKLWHOHDGWRWKHEUDQFKFLUFXLWQHXWUDO
ZKLWHRUJUD\LQFRORUXVLQJZLUHQXW
&RQQHFWWKHRYHQUHGOHDGWRWKHEUDQFK
FLUFXLWUHGOHDGDQGWKHRYHQEODFNOHDGWR
WKHEUDQFKFLUFXLWEODFNOHDGLQ
DFFRUGDQFHZLWKORFDOFRGHVXVLQJZLUH
QXWV IWKHUHVLGHQFHUHGEODFNRUZKLWH
OHDGVDUHDOXPLQXPFRQGXFWRUVVHH
³:$51 1*´QRWH6HHSDJH
&D
&E
25
1(:&216758&7,21$1'
)285&21'8&725%5$1&+
&,5&8,7&211(&7,21
:KHQLQVWDOOLQJLQDQHZFRQVWUXFWLRQRU
:KHQLQVWDOOLQJRYHQLQDPRELOHKRPHRU
:KHQORFDOFRGHVGRQRWSHUPLWJURXQGLQJ
WKURXJKQHXWUDO
&XWWKHQHXWUDO:KLWHOHDGIURPWKH
FULPS5HVWULSWKHQHXWUDOZKLWHOHDGWR
H[SRVHWKHSURSHUOHQJWKRIFRQGXFWRU
DQGFRQQHFWLWWRWKHZKLWHRUJUD\
EUDQFKFLUFXLWQHXWUDOLQDFFRUGDQFHZLWK
ORFDOFRGHXVLQJZLUHQXWV
$WWDFKWKHDSSOLDQFHJURXQGLQJOHDG
JUHHQRUEDUHFRSSHULQDFFRUGDQFH
ZLWKORFDOFRGHV IWKHUHVLGHQFH
JURXQGLQJFRQGXFWRULVDOXPLQXPVHH
:$51 1*QRWH6HHSDJH
&RQQHFWWKHRYHQUHGOHDGWRWKH
EUDQFKFLUFXLWUHGOHDGDQGWKHRYHQ
EODFNOHDGWRWKHEUDQFKFLUFXLWEODFN
OHDGLQDFFRUGDQFHZLWKORFDOFRGHV
XVLQJZLUHQXWV IWKHUHVLGHQFHUHG
EODFNRUZKLWHOHDGVDUHDOXPLQXP
FRQGXFWRUVVHH³:$51 1*´QRWH
6HHSDJH
&D
&E
&F
Ground
Wires
Alternate
Knockout
Black
Red
White
Range Conduit
Snaps
into Box
Branch
Circuit
Alternate
Knockout
Black
Red
Range Conduit
Snaps
into Box
Branch
Circuit
Ground and
NeutralWires,
White
1HXWUDOEDUHZLUH
FRQQHFWLRQ

10
'RQRWVKRUWHQWKHIOH[LEOHFRQGXLW7KHFRQGXLWVWUDLQUHOLHIFODPSPXVWEHVHFXUHO\
DWWDFKHGWRWKH XQFWLRQER[DQGWKHIOH[LEOHFRQGXLWPXVWEHVHFXUHO\DWWDFKHGWRWKH
FODPS,IWKHIOH[LEOHFRQGXLWZLOOQRWILWZLWKLQWKH XQFWLRQER[GRQRWLQVWDOOWKHRYHQXQWLO
DFODPSRIWKHSURSHUVL]HLVREWDLQHG
127(72(/(&75 & $17KHSRZHUOHDGVVXSSOLHGZLWKWKLVDSSOLDQFHDUH8/UHFRJQL]HGIRU
FRQQHFWLRQWRODUJHUJDXJHKRXVHKROGZLULQJ7KHLQVXODWLRQRIWKHVHOHDGVLVUDWHGDW
WHPSHUDWXUHVPXFKKLJKHUWKDQWKHWHPSHUDWXUHUDWLQJRIKRXVHKROGZLULQJ7KHFXUUHQWFDUU\LQJ
FDSDFLW\RIWKHFRQGXFWRULVJRYHUQHGE\WKHWHPSHUDWXUHUDWLQJRIWKHLQVXODWLRQDURXQGWKHZLUH
UDWKHUWKDQWKHZLUHJDXJHDORQH
&
5HLQVWDOO-XQFWLRQER[FRYHU

11
Electrical Connections
Slide-In Range
C1 Removewirecoverat
lowerrearofrange.
WIRE COVER
C2 Whenusingapowercord,removethe
knockoutintheconnectionplatewith
pliersasrequiredbythesizeofthe
strainrelieforclampsuppliedwithcord.
Knockout
Terminal
Housing
C3 Insertpowercordthroughholeinthe
terminalhousing,engageandtighten
strainreliefclamp,leavingenoughwire
lengthtoattachterminalstoterminal
block.
C3a
Connection
Plate
Strain
Relief
Clamp
3 wire
cord kit
FOLLOWINSTRUCTIONSBELOWIF
YOURCORDIS3WIRE.
Thepowercordcenterwiremust
beconnectedtomiddleterminal
onblock.Attachremainingwires
securely.Donotremoveground
strap
C5 Re-installthewirecovermakingsure
thewiresdonotbecomepinched
betweenwirecoverandhousing.
50 Amp 4 Wire
C4a Followinstructions
belowifyourcordis4
wire.
C4b Removethescrewson
theterminalblock.Do
notremoveterminal
block.
Remove
3 screws
REMOVE & DISCARD
GROUND STRAP
GROUND
WIRE
REUSE
GROUND WASHER
& GROUND SCREW
C4c Removethe
greenground
screw.Then
removethe
groundstrapand
discardit.
TerminalBlock
C4d Attachthegreenorbarewirebelowthe
terminalblockwiththegreenground
screwandwasherthatwereremoved
earlier.
C4e Connecttheredandblackwirestothe
outsideterminals.Thewhitewiremustbe
connectedtothecenterterminal.
OR
Remove
3 screws
Black White
Red
3-Screws
Grounded
Neutral
Terminal
Center
Wire
(white)
Ground
Wire
Strain
Relief
Clamp
Ground Screw
& Washer
Black White Red
50 Amp 3Wire
NEWCONSTRUCTIONANDFOUR
CONDUCTORBRANCHCIRCUIT
Strain
Relief
Clamp
GEA01051

12
'
7KHDQWLWLSEUDFNHWLVDWWDFKHGWRWKHEDFN
RIWKH'URS Q5DQJH WLVGHVLJQHGWRILW
XQGHUWKHERWWRPRIWKHFRXQWHUWRS
RSHQLQJDWWKHUHDU0HDVXUHFRXQWHU
WKLFNQHVVDWEDFNRIFXWRXWWRGHWHUPLQH
FRUUHFWEUDFNHWORFDWLRQ
,QVWDOOLQJWKH$QWL7LS%UDFNHW
IRU´FRXQWHU
IRU´FPFRXQWHU
$OWHUQDWH6KRZQ%HORZ
IRU´FRXQWHU
IRU´
6HOHFWWKHSURSHUSRVLWLRQIRUWKHFRXQWHUWRS
WKLFNQHVVDQGPRYHEUDFNHWWRSURSHUSRVLWLRQ
8QLWLVVXSSOLHGZLWKEUDFNHWLQSRVLWLRQ
Wire
Cover
Wall
Stud
Anti-Tip
Bracket
Bottom of
Countertop
To Engage
Bracket By
1/2" Min.
Glass Maintop
InteriorWall
ANTI-TIP
INSTALLATIONS
Bottom of
Countertop
Countertop
Thickness
Min. 1/4" Flat Area
Attachment
Anchored to
Wall Stud Is
Required
Anti-Tip
Bracket
Attachment
To Engage
Bracket By 1/2" Min.
Position #5
Non Kit
Applications
1-1/2"
10 -3/8"
Attachment
*
Wire
Cover
Wall
Stud
Glass Maintop
InteriorWall
ALTERNATE ANTI-TIP
INSTALLATIONS
Countertop
Surface
Non Kit Application
1
2
3
4
5
Anti-Tip Bracket Location
( Rear of Range )
Glass Cooktop
Anti-Tip Bracket Installation
Drop-In Range

13
3ODFLQJWKH5DQJHLQWRWKH2SHQLQJ
' WLVVXJJHVWHGWKDWWZRSHRSOHOLIWWKH
UDQJHLQWRSODFHFDUHIXOO\VHWWLQJWKH
VLGHPHWDOIODQJHVXQGHUWKHJODVVRQ
WKHHGJHVRIWKHFRXQWHUWRSRSHQLQJ
7KHSURWHFWLYHFKDQQHOVPXVWEHLQ
SODFHLIVXSSOLHGGXULQJWKLVRSHUDWLRQ
&DUHIXOO\VOLGHWKHUDQJHWRZDUGWKH
EDFNRIWKHRSHQLQJ QWKHODVW´RI
WUDYHOOLIWWKHIURQWRIWKHUDQJHDSSUR[
´WRFOHDUWKHVWRSVFUHZVORFDWHGLQ
WKHVLGHVRIWKHFDELQHWDQGVOLGHWKH
UDQJHXQWLOWKHUDQJHLVVHDWHG/RZHU
IURQWRIWKHUDQJHRQFRXQWHUWRS
COUNTER TOP
CABINET
RANGE
LIFT & SLIDE RANGE
ON COUNTER TOP
Countertop
Make sure the edge
of the countertop fits flush
against the end of the
Front Control Panel
,QVWDOO6WRS6FUHZ
' 7KHVHVFUHZVSUHYHQWWKHUDQJHIURP
VOLGLQJRXWRISRVLWLRQGXULQJRSHUDWLRQ
&DUHIXOO\PDUNWKHFDELQHWIRUWKHORFDWLRQRI
WKHVWRSVFUHZV'ULOO´SLORWKROHVLQWRWKH
FDELQHWHDFKVLGHRIWKHUDQJH0DNHVXUH
QRWWRGULOOHQWLUHO\WKURXJKWKHFDELQHWZDOO
&DUHIXOO\WXUQWKHVKRXOGHUVFUHZVLQWRWKH
SLORWKROHVXQWLOWKH\DUHWLJKW
26-1/4" from
Countertop to
center line of
Screw 2-1/2" from
front edge of
Countertop to
center line of
Screw
One Screw
each side

14
&DUHIXOO\UHPRYHWKHSURWHFWLYH
FKDQQHOVIURPWKHVLGHVRIWKHJODVV
FRRNWRS7KLVPD\UHTXLUHDVOLJKWOLIWLQJ
RIWKHUDQJHWRUHPRYHWKHZHLJKWRIWKH
UDQJHIURPWKHSURWHFWLYHFKDQQHOV
'
5HPRYHWKH3URWHFWLYH&KDQQHOV
,I3URYLGHG
$WWDFKWKHORZHUWULPVXSSOLHG
VHSDUDWHO\ZLWKWKHUDQJHWRWKH
ERWWRPRIWKHYHUWLFDOVLGHWULPZLWKWKH
VFUHZVVXSSOLHG
'
$WWDFKWKH/RZHU7ULP
/RRNDWERWKVLGHVRIWKHUDQJHXQGHU
WKHGRRU7KHVWRSVFUHZVPXVWEH
ORFDWHGLQWKHQRWFKRQWKHVLGHVRIWKH
UDQJHDQGQRWWRXFKWKHWRSRIWKH
QRWFKZKHQWKHUDQJHLVIXOO\VHDWHGRQ
WKHFRXQWHUWRS IWKHVFUHZVGRQRW
PHHWWKHUHTXLUHPHQWVPRYHWKH
VFUHZVWRDSRVLWLRQWKDWPHHWVWKHVH
UHTXLUHPHQWV6HHLOOXVWUDWLRQEHORZ
'
&KHFN)RU3URSHU,QVWDOODWLRQRIWKH
6WRS6FUHZ
LOWER LEFT
CORNER
FRONT FRAME
END FLANGE
& TAB ON
LOWER TRIM
FITS INSIDE
SIDE TRIM
LOWER
TRIM
ATTACH
1- SCREW
EACH SIDE
SIDE
TRIM
TOP FLANGE
1/2" WIDE
CLEAR
SHOULDER
SCREW
SIDE
TRIM
NOTCH IN BOTTOM
OF SIDE TRIM
GLASS COOK TOP PROTECTIVE
COVER
REMOVE PROTECTIVE COVER FROM BOTH SIDES
AFTER RANGE IS IN CABINET
PULL

15
'
&KHFNIRU3URSHU,QVWDOODWLRQRI
$QWL7LS%UDFNHW
/RZHUWKHRYHQGRRUDQGJHQWO\DSSO\
PHGLXPIRUFHDWWKHKDQGOHHQGXQWLO
PRYHPHQWRIWKHUDQJHLVGHWHFWHG
&RQWLQXHSUHVVLQJXQWLOWKHDQWLWLS
EUDFNHWLVHQJDJHGDQGPRYHPHQW
VWRSV$VPDOODPRXQWRIPRYHPHQWLV
DFFHSWDEOHDWWKHEDFNRIWKHUDQJH
WRSEXWLWVKRXOGEHVWDEOHDQGQRWWLS
RQFHWKHDQWLWLSEUDFNHWLVHQJDJHG
0DNHVXUHERWKKLQJHVDUHLQWKH
EURLOVWRSSRVLWLRQ
'
5HSODFHWKH2YHQ'RRU
*UDVSWKHGRRURQERWKVLGHV
'
/LIWWKHGRRURYHUWKHKLQJHVOLQLQJ
XSWKHKLQJHVZLWKWKHKLQJHVORWVRQ
WKHERWWRPRIWKHRYHQGRRU
'
6OLGHWKHGRRUGRZQRQWRWKHKLQJHV
DVIDUDVLWZLOOJRDQGFORVHWKH
RYHQGRRU
'
&$87,217KHRYHQGRRULVKHDY\
<RXPD\QHHGKHOSOLIWLQJWKHGRRU
KLJKHQRXJKWRVOLGHLWGRZQRQWR
WKHKLQJHV'RQRWOLIWWKHGRRUE\WKH
KDQGOH

16
Anti-Tip Bracket Installation
Slide-In Range
a. Forconcreteinstallationyouwillneedtwo
1/4"x1-1/2"lagscrews,andtwosleeve
anchors.
b. Locatethecenterofthefourholesidentified
inFig.1asFloor-ConcreteandWall.Drill
therecommendedsizeholesineach.
c. Installthesleeveanchorsintothepredrilled
concreteholesandinstallthelagandwall
screwsthroughtheAnti-Tipbracket.Make
surethescrewsaresecurelytightened.
a. Locatethecentersofthefourholesidentified
inFig.1asFloor-WoodandWall.
b. Drilla1/8"pilotholethroughthepre-marked
areas.Notetheangleofthewallscrewin
Fig.2.
c. MounttheAnti-Tipbracketwiththefour
screwsprovided.
LocatingTheBracket
a. Decidewhetherthebracketwillbe
installedontherightorleftsideofrange
opening.
b. PlacethebracketasshowninFig.1.
Fig.1
InstallingTheBracketinWood
orConcrete
D1
INSTALLATION-WOODCONSTRUCTION
I
NSTALLATION
-CONCRETECONSTRUCTION
D2
Fig.2
ATTACHMENTTOWALL
WALL
PLATE
BRACKET
SCREW MUST
ENTERWOOD
OR METAL
TO FRONT EDGE
OF
COUNTERTOP
25"
WALL
FLOOR-WOOD
REAR
LEVELING
LEG
ADJACENT CABINET
BRACKET
SIDE
FLOOR-CONCRETE
30"
Equal Space
Each Side
LargerThan 30" Opening
GEA01052

17
Positiontherangeinfrontofthe
cabinetopening.
SLIDERANGEINTOOPENING
E1
E8
Makesurethattheglasswhich
overhangsthecountertopclearsthe
countertop.Raisetheunitbylowering
thelevelinglegsifnecessary.
E2
Pushwhileliftingtherangeintothe
openinguntiltherangeiswithin2"of
engagingtheanti-tipbracket.
E3
E4 Removetheprotectivetrimfromthe
sideofglass.(Ifprovided)
E5 Usingtheadjustablepliersorwrench
carefullyscrewinthebacklevelingleg
untiltheglassoverhangcomestorest
onthecountertop.
E6 Thencarefullyscrewinthefronttwo
levelinglegs(similartoE5)untilthe
glassoverhangtouchesthe
countertop.
Plugrangecordintoreceptacle.Locate
thecordinthebackoftherangeina
mannerthatwillnottouchorbemoved
bythedrawer.
Countertop
Make sure the edge
of the countertop fits flush
against the end of the
Front Control Panel
E7 Carefullypushtherangeintothe
openinguntilthecountertopfully
engagesthecontrolpanel.Theback
glassoverhangshouldcoverthecutout
opening.
STORAGE DRAWER
POSITION RANGE CORD
SOTHAT THERE IS NO
INTERFERENCEWITH
STORAGE DRAWER
GEA01053
AdjustableWrench
or Pliers

18
E9 Wheninstallationis
completeandthe
rangeisinplace,
inspecttobesure
therearlevelingleg
isfullyinsertedinto
theslotoftheAnti-
TipBracket.
FinalCheckoftheAnti-TipBracket
E10 Makesurethehingeisinthebroil
stopposition.
Graspthedooronbothsides.
Liftthedooroverthehingesliningup
thehingeswiththehingeslotsonthe
bottomofthedoor.
Slidethedoordownontothehinges
asfarasitwillgoandclosethedoor.
E11
E12
E13
CAUTION:Theovendoorisheavy.
Youmayneedhelpliftingthedoor
highenoughtoslideitdownonto
thehinges.Donotliftthedoorby
thehandle.
ReplacingtheOvenDoor
Placethe
drawerrailon
theguides.
ReplacingtheStorageDrawer
E14
Pushthe
drawerinuntil
itstops.
E15
Liftthefrontofthedrawerandpushin
untilthestopscleartheguides.
IFDRAWERWON'TCLOSE
Removeandreplace,makingsurethepower
cordisnotobstructingthedrawerand/orthe
railisintheguide.
IFDRAWERISCROOKED
Lowerthefrontofthedrawerand
pushinuntilitcloses.
Removeandreplacemakingsuretherailisin
theguide.
SPECIALINSTRUCTIONSIFYOU
HAVEPROBLEMSWHILE
REPLACINGTHESTORAGE
DRAWER
E17
Stop
E16
GEA01054
Other manuals for JD966
1
This manual suits for next models
4
Table of contents
Other GE Range manuals

GE
GE JGBS17DEM Manual

GE
GE Profile PGS950SEF User manual

GE
GE JGBP88D Manual

GE
GE JS998 Series User manual

GE
GE Appliances Profile JGB902 Original instructions

GE
GE JGSP28CEK Manual

GE
GE PB970SPSS - Profile 30 in. Electric Double Oven... Manual

GE
GE JB640MNBS Manual

GE
GE JGB620DEFBB Manual

GE
GE JGB296SETSS Manual
Popular Range manuals by other brands

Jenn-Air
Jenn-Air JDS8850BDS installation instructions

Danby
Danby DR3099BLGLP Owner's use and care guide

Whirlpool
Whirlpool WFG500M4HS User instructions

Viking
Viking Professional Custom VGCC5366BSS installation guide

Frigidaire
Frigidaire FEF355A Factory parts catalog

Atwood
Atwood RA Installation, operation and maintenance