PLL VCV (Varactor Control Voltage)
zConnect the DC voltmeter between TP1 on the Main Unit and Ground.
zSet the transceiver to CH1 (low band edge), and adjust TC301 on the Main Unit for 1.0V ±
0.1V on the DC voltmeter, while receiving.
zSet the transceiver to CH1 (low band edge), and adjust TC302 on the Main Unit for 1.0V ±
0,1V on the DC Voltmeter, while transmitting.
zSet the transceiver to CH3 (high band edge), and confirm the high-end VCV is lower then
12.0V while receiving, and low than 12.0V while transmitting.
PLL Reference
zSet the transceiver to CH1 (low band edge), and adjust trimmer of the VCXO on the Main
Unit for band center frequency ±100Hz .
Transmitter Output Power
zSet the transceiver to CH1 (low band edge), and adjust RV2 on the Main Unit for that the
power meter reading is 5W. Confirm that the current consumption is 2.0A or below.
zSet the transceiver to CH1 (low band edge), and adjust RV3 on the Main Unit for that the
power meter reading is 1W. Confirm that the current consumption is 1.0A or below.
Modulation Level
Max Deviation: (VCO Modulation)
zSet the transceiver to CH2 (band center).
zInject a 1KHz tone at 100mVrms to the MIC jack.
zAdjust RV501 on the Main Unit for the deviation meter reading is ±4.2KHz(for 25KHz
steps) or ±2.1KHz(for 12.5KHz steps) deviation.
MIC Sensitivity
zSet the transceiver to CH2 (band center)
zInject a 1KHz tone at 100mVrms to the MIC jack.
zAdjust tone level so that the deviation meter reading is ±3.0KHz (for 25KHz steps) or ±
1.5KHz (for 12.5KHz steps) deviation.
CTCSS Deviation
zSet the transceiver to CH2 (band center).