Global Leak Detection GLD-40 User manual

OPERATOR’S MANUAL
Diagnostic Smoke® Vapor Machine
with UltraTraceUV® Dye Solution
Leak Detection System
Model No. GLD-40
USA | Canada Patents ●6,392,227 • 6,526,808 | 2,279,147 | Int’l Patents Pending


i
Caution
Usage Tips
TO PREVENT PERSONAL INJURY
AND / OR DAMAGE TO VEHICLE OR EQUIPMENT
ALWAYS use on vehicle with engine turned <OFF>.
Use this equipment in the manner specified by the manufacturer.
Understand operating procedures / Follow all safety precautions.
Connect Tester to chassis ground.
Use UltraTraceUV®Smoke Solution No. GLD0712UV in this Tester. Using a non-approved
solution may cause damage to vehicles being tested and may cause personal injury.
Never leave the Tester’s hoses or power cables connected to the vehicle for extended periods
of time when tests are not being performed.
Do not perform test near source of spark or ignition.
Wear eye protection that meets OSHA standards.
Follow safety precautions when using ultraviolet light source.
Always use hood support if hanging Tester from hood of car.
Air pressure (or gas pressure) supplied to Tester can be between 50-175 PSI (3.4 to 12 bar).
!
Connect to workshop airline for general purpose leak detection applications.
Smoke exiting a very small leak is sometimes even easier to see if after filling the system with smoke you reduce
the smoke flow by turning the flow control knob clockwise, which slows the exiting smoke velocity and helps you
see very small leak(s)
Use the white light provided to highlight the smoke exiting a leak.
Use the Ultraviolet (UV) light and yellow glasses provided to look for the fluorescent deposit at the exact location
of a leak. When using alternate source of UV light, be sure it is one that covers the 400 nanometer (nm) UV light
range.
When operating the Tester in near freezing temperatures, cycle the operation of the Tester 15 seconds ON and 15
seconds OFF for approximately the first minute or two of operation. This will allow the Tester to reach its
optimum operating temperature.
When testing an engine's intake or exhaust system for leaks, it is recommended that the engine be cold. Small
leaks may be sealed due to thermal expansion.

ii
Table of Contents
Included with the Smoke Wizard
Prior to using Smoke Wizard®for the First Time
Specifications
Smoke Wizard®Overview
Basic Testing Procedure
Leak Detection Applications
Troubleshooting
Warranty
Material Safety Data Sheet (MSDS)
CE Certificate
Page 1
Page 2
Page 3
Page 3 & 4
Page 5
Page 6 – 8
Page 9
Page 10
Page 11 – 14
Page 15
Be sure to visit our website http://www.smokewizard.co.uk for:
●Instructional Videos ●Additional Product Details
●Frequently Asked Questions ●Tech Tips ●Downloads
Congratulations! You have purchased the finest and most feature-rich portable leak
detection smoke machine available today. The patented technology inside your Smoke
Wizard was designed in collaboration with major automakers; was designed specifically to be
safe for leak testing a vehicle’s fuel evaporative (EVAP) system as well as many other vehicle
systems; is the only technology in the world approved by any automaker; and is the only
smoke technology that meets SAE INTERNATIONAL published papers recommendation to use
a smoke machine designed to function with an inert gas (such as Nitrogen, Argon or CO2)
when testing a vehicle’s EVAP system [SAE: 2007-01-1235 & 2008-01-0554].
Global Leak Detection Corp. and our Authorized Distributors, Smoke Wizard UK, thank you
for the purchase of your new Smoke Wizard!
Diagnostic Smoke®Vapor – Safe for Vehicle Systems.

1
Included with the Smoke Wizard®
UltraTraceUV®;(GLD0712UV) this patented solution is the only Automaker-
approved smoke-producing solution in the world. The solution’s chemistry contains
a special dye that deposits at the exact location of a leak. Will not harm automotive
systems and will perform approximately 300 tests. (12 oz. / 355 ml). (Part number is
for one 12 oz. bottle. Two bottles included with machine)
Combination Light: (GLD043K) delivers a white light for easier smoke location, an
ultraviolet (UV) light that highlights the fluorescent dye deposited at the exact
location of a leak and red laser pointer light. Includes 3 AAA batteries and glasses.
EVAP Service Port Adaptor – standard size: (GLD003)
Dual-Size Schrader Valve Removal/Installation Tool: (GLD004) The Schrader valve
has a left-hand thread. Turn clockwise to remove!
Cap Plugs Kit: (GLD005) these cap plugs are useful when sealing an intake manifold
system in order to contain the smoke in the system for proper leak testing, such as
mass airflow sensor ducting, etc
Smoke Diffuser: (GLD006) this adapter is designed to locate leaks around doors,
windows, sunroofs and trunk compartment. The adapter allows the operator to lay
down a thick bed of smoke (from outside the vehicle) along door and window seams
in order to watch for disturbance caused by escaping airflow due to a leaking seal.
Internal pressure is created by vehicle’s HVAC set to fresh air (i.e. not recirculation)
and blower fan on high speed.
Adapter Cone: (GLD007) for introducing smoke into the exhaust system or into any
orifice that accommodates the cone's size, such as the induction system
Adapter: (9995545). NOTE: This adapter, while part
of the overall kit, is not included with the Smoke
Wizard®, but instead arrives separately from SPX.
Use this adapter to introduce smoke into the
engine intake system, as illustrated.

2
Prior to Using Smoke Wizard®for the First Time
NOTE: Your Smoke Wizard arrives with: a commonly used male quick-disconnect Air Fitting
and two bottles (12 oz/355 ml) of UltraTraceUV® Smoke Producing Solution.
1. Be sure the Smoke Wizard’s Air Fitting is the correct fitting
for your air hose connector or change it to match. (Figure 1)
2.Remove the Smoke Wizard’s dipstick; pour the entire contents of one bottle into the smoke
chamber; verify correct level and secure dipstick. (Figure 1)
NOTE: Use the second bottle supplied to maintain solution level at or near FULL mark.
NOTE: Your Smoke Wizard is now ready for operation.
NOTE: A common question asked is if one can use a basic generic mineral oil, such as ‘Baby Oil’, in the
Tester to create the smoke.
You can if you want to, but we don’t recommend it. The patented UltraTraceUV® smoke solution
supplied with this Tester; will perform hundreds of tests that only cost pennies per test; is the only
solution in the world approved by the auto manufacturers; and will not void any vehicle factory
warranties. Plus you have the added benefit of the trace dye that marks the exact location of a leak,
increasing diagnostic accuracy unlike any other. This special solution is not a “generic” mineral oil. In
fact, generic mineral oils are not intended for this type industrial use. The generic mineral oils break
down, evidenced by its foul odor and could damage vehicle components.
Caution: Factory vehicle bonnet supports are not designed
to support more than the weight of the bonnet. A
supplemental prop rod (or similar device) such as the one
shown here should always be used when hanging the
smoke machine from the bonnet, in order to avoid hazard
and possible injury due to a hood falling unexpectedly.
!
Figure 1
Air Fitting
Smoke solution port

3
Smoke Wizard®Overview
Technical Specifications
Height (less hanger)
Length
Width
Weight
Shipping weight
Power supply
Power consumption
13 in. (33 cm)
5.5 in. (14 cm)
9.5 in. (24 cm)
10 lb. (4.5 kg)
14 lb. (6.3 kg)
12 volts DC
15 amps.
Supply pressure
Supply volume
Smoke supply line
Power supply line
Operating temp. range
Solution Max. Volume
13.0 in. H2O (0.032 bar)
10 liters per minute
10 feet (3m)
10 feet (3m)
45°F to 140°F (7.2°C to 60°C)
12 oz. (355 ml)
12V DC Power-Supply Cables
(Rear of Tester)
Suspension Hanger – allows the
option of hanging your Smoke
Wizard from a convenient test
location on the vehicle or for
storage when not in use.
Note: Always use bonnet support
device when hanging from the
bonnet.
Filter Drain Port – located under Tester;
keeps Tester and vehicle clean by
automatically draining water and
contaminants from shop air compressor.
Control Panel
–
See next page
Smoke Solutio
n Dipstick
–
use to
check and maintain proper smoke
solution level.
Smoke Supply hose
–
hose with
scratch-resistant Delrin® nozzle
delivers the smoke vapor into a
system for leak testing.
Air Fitting
–
connect to shop a
ir
or
inert gas. Note: There is a pressure
regulator inside the Tester so no
external regulator is required as long
as input pressure is between 50 and
175 PSI (3.4 to 12 bar).

4
Control Panel Overview
Flow Meter: If the meter indicates flow, then you know there
is flow going into (or through) the system being tested. If
flow meter indicates flow after the system is filled, this
indicates a leak. The higher the ball is in the flow meter, the
larger the leak size.
No flow indicates no leak.
Observing the flow meter behavior allows Technicians to
judge system blockage, restrictions, control effectiveness, and
system operational integrity.
Flow Control Valve: Easy to read ¼ turn valve allows
total control of the volume of Diagnostic Smoke® vapor
exiting the leak. First, fill system with smoke at full
flow. Then reduce the smoke volume by adjusting the
Flow Control Valve so that the leak is even easier to
see.
Sometimes less smoke exiting a small leak is easier
to see.
Flow Control Valve does not affect delivery pressure;
it only affects the volume of flow.
SMOKE Light
(Red):
Turns ON
when you press the START
button, indicating smoke
production.
POWER Light (Green):
Turns
ON when you connect Tester
to 12-
Volt DC power.
Blinks if the battery power
source is insufficient.
START Button:
Press for smoke production.
Note: Is on 5-minute timer.
Pressure Gauge:
(-30 to +30 IWC) used to verify
leak(s) in a system, using either
pressure-decay or vacuum-decay.
The pressure / vacuum decay
test cannot tell the size of the
leak(s). Leak size can be
determined using the indexed
flow meter.
Indexed on Flow Meter:
indicates
three critical EVAP leak thresholds
of .010" .020" and .040" for
diagnostic accuracy.
.040" (1 mm)
.020" (½ mm)
.010" (¼ mm)
.
Note: Flow Control Valve must be
in full flow position for proper
measurement.

5
Basic Testing Procedure
1. Connect Tester to shop air. See Optional Gas Source below.
2. Connect Tester’s Red power cable to vehicle’s 12 Volt DC battery
positive terminal.
>Battery must be in good condition and fully charged!
3. Connect Tester’s Black cable to vehicle’s chassis ground. Do NOT
connect the black cable to battery ground because a spark in the vicinity
of the battery can cause an explosion! (Figure 2)
4. Observe that the Green Power indicator lamp on the Tester is ‘ON’
confirming that you are properly connected.
>A blinking green power lamp indicates insufficient battery power to the
Tester.
5. Connect smoke supply hose to system being tested.
6. Flow Control Valve must be in Full Open position. (Figure 3)
7. Press START button and fill system with smoke.
>Whenever possible it is best to ‘purge’ the ‘non-smoke’ air out of the system
being tested in order to quickly fill the system with smoke.
>Smoke production is on 5-minute timer.
8. Use white light supplied and look for exiting smoke or use ultraviolet light
supplied to look for fluorescent dye deposit at exact location of a leak.
>The longer smoke is allowed to exit a leak, the more fluorescent dye will be
deposited at leak locations.
Figure 2
Black to
chassis
ground
Figure
3
Flow
Control
+
Do NOT run the vehicle engine with the Smoke Wizard® supply
hose connected to the vehicle. Normal engine vacuum will
damage the pressure/vacuum gauge!
!

6
Sample Leak Detection Applications:
This leak Tester can be used in virtually any vehicle low pressure system suspected of having a leak, such
as; intake / induction system, intercooler and turbocharger system, vacuum system, exhaust system,
wind/water leaks and can also be used to verify air solenoid functions and test components prior to
assembly.
1. Introduce smoke into system.
2. Look for smoke (or dye) exiting leak(s).
Intake / Induction Leaks
Exhaust Leaks

7
Wind and Water Leaks
1
1.
.S
Se
et
tv
ve
eh
hi
ic
cl
le
e’
’s
sc
cl
li
im
ma
at
te
ec
co
on
nt
tr
ro
ol
lt
to
o‘
‘F
Fr
re
es
sh
hA
Ai
ir
r’
’a
an
nd
ds
se
et
tb
bl
lo
ow
we
er
ro
on
nf
fu
ul
ll
ls
sp
pe
ee
ed
d.
.
>
>T
Th
hi
is
sc
cr
re
ea
at
te
es
sp
po
os
si
it
ti
iv
ve
ec
ca
ab
bi
in
np
pr
re
es
ss
su
ur
re
e.
.
2
2.
.C
Co
on
nn
ne
ec
ct
tT
Te
es
st
te
er
r’
’s
ss
su
up
pp
pl
ly
yh
ho
os
se
en
no
oz
zz
zl
le
et
to
oS
Sm
mo
ok
ke
eD
Di
if
ff
fu
us
se
er
r.
.
3
3.
.L
La
ay
ys
sm
mo
ok
ke
ep
pa
at
th
ha
al
lo
on
ng
gs
se
ea
al
ls
s.
.
4
4.
.L
Lo
oo
ok
kf
fo
or
rs
sm
mo
ok
ke
ed
di
is
st
tu
ur
rb
ba
an
nc
ce
ei
in
nd
di
ic
ca
at
ti
in
ng
ga
al
le
ea
ak
k.
.
<
Smoke distrubance pinpoints the leak
No air distrurbance means ‘No Leak’
>

8
Sample Fluorescent Dye Deposits
The patented smoke vapor contains a special ultraviolet-activated fluorescent dye that gets deposited at
the exact location of a leak. Use the UV light provided to highlight the dye.
>This technology is designed so that the dye will only deposit if there is pressure-differential. So for
instance, the dye will deposit when exiting a leak but will not deposit during the wind and water test.
>The longer the smoke is allowed to exit a leak, the more dye will be deposited.

9
Troubleshooting Guide
Your Smoke Wizard has two indicator lights on the control panel that double as diagnostic lights,
indicating if the Tester is working correctly. The following table describes the indicator light function
codes.
Green Red Interval Cause
Constant ON Sufficient battery power
Blinks: 1 per second Insufficient battery power
Blink simultaneously: 1 per second Bad ground or power connection at smoke
canister or short in circuit
Blink simultaneously: 4 times per second Bad ground at smoke canister or open
heating circuit
Blink alternately: 1 per second
(System will shut down; Power must be
disconnected then reconnected)
Bad ground. Can also mean circuit board
failure ٭
Symptom Likely Cause Solution
The green power
indicator lamp on the
Tester does not turn
ON.
1. The power cables are reversed.
2. Poor power-supply cable
connection.
3. Battery providing power is too
weak.
1. Correctly position the power cables.
2. Secure the connection at the positive
terminal and chassis ground.
3. Verify the battery is in good condition
and fully charged.
I turn the Tester ON but
there is no air or smoke
coming out of the
supply hose.
1. Flow Control valve is closed.
2. Poor power-supply cable
connection.
3. Battery providing power is too
weak.
4. Air supply to tester is
insufficient.
5. Smoke-vapor could be
condensing inside the smoke
supply hose, restricting smoke
flow.
1. Open flow control.
2. Secure the connection at the positive
terminal and chassis ground.
3. Verify the battery is in good condition
and fully charged.
4. Be sure air supply is sufficient.
5. Be sure the smoke hose is fully
extended when in use. Drain the
condensation from the hose prior to its
next use, either by placing the machine
higher than the hose, or by removing the
hose and blowing through it with
compressed air. Do NOT blow
compressed air into the machine with the
smoke hose connected to the machine.
٭If circuit board failure occurs, first try disconnecting power to your Smoke Wizard for 10 seconds and
reconnect. If this failure code occurs a second time, disconnect Smoke Wizard and contact Smoke Wizard UK
at: SmokeWizardSupport@virginmedia.com.

10
Warranty
Warranty Issues or Questions? Contact Smoke Wizard UK
SmokeWizardSupport@virginmedia.com
www.SmokeWizard.co.uk
Activate Your Warranty
To activate your Smoke Wizard®warranty; send the information below to the email address provided
within 30 days of your purchase.
Purchaser’s Name:
Company Name:
Address:
Country:
Telephone number:
Email address:
Web address:
Enter Smoke Machine Model as: GLD-40 (J/LR)
Serial Number:
Date Purchased (keep your invoice for verification, if needed):
LIMITED ONE (1) YEAR WARRANTY
Global Leak Detection warrants the Smoke Wizard to the Original Purchaser that under normal use,
care and service, the Equipment (except as otherwise provided herein) shall be free from defects in
material and workmanship for ONE YEAR from the date of original invoice.
Seller's obligations under this warranty are limited solely to the repair or, at Seller's option, replacement of or
refund of the original purchase price for, Equipment or parts which to Seller's satisfaction are determined to be
defective and which are necessary, in Seller's judgment, to return the equipment to good operating condition.
Repairs or replacements qualifying under this Warranty will be performed or made on regular business days
during Seller's normal working hours within a reasonable time following Buyer's request. All requests for
warranty service must be made during the stated warranty period.
© Global Leak Detection Corp/ Smoke Wizard UK
Rev. 27June2011

MATERIAL SAFETY DATA SHEET Page 1 of 4
COUNTRY
U.S.A.
% (by
Weight) Hazard
Symbol
Notes:
SKIN:
EYES:
NTP?
CALIFORNIA, Prop.65? OSHA REGULATED?
PRODUCT NAME:
UltraTraceUV®
(Fluorescent Diagnostic Smoke® Solution)
PRODUCT PART NUMBERS: GLD0712UV | GLD0708UV
GENERAL USE:
TRADE NAME:
DATE PREPARED:
SUPERSEDES:
Global Leak Detection Corp.
NO NO NO
This is basically a safe product. However, human health risks vary from person to person. As with any petroleum base product, reasonable caution
should be taken to avoid prolonged and repeated exposure to the base product.
CAS #
Non-Hazardous
Hazardous Components
THIS PRODUCT HAS A LOW ORDER OF ACUTE ORAL TOXICITY. If base product is swallowed it presents a low risk of aspiration into the
lungs. In the event that swallowing the base product in small quantities does take place, it is expected to pass through the system without
symptoms. As with anypetroleum base product : If large quantities are swallowed and subsequently aspirated into the lungs, mild to severe
pulmonary injury may occur.
EMERGENCY OVERVIEW
INHALATION:
INGESTION:
The balance of the ingredients are proprietrary and non-hazardous as defined in US 29CFR 1210 and European regulation directive
67/548 EEC.
SECTION 3 - HAZARDS IDENTIFICATION
POTENTIAL HEALTH EFFECTS
UltraTraceUV®
Colorless to Very Pale Amber. Mineral Oil Type Odor.
DATE: June 25, 2011
Proprietary Pharmaceutical USP Petroleum Blend with APD Dye
TELEPHONE NUMBER FOR INFORMATION / Customer Service
1-714-433-2841
Proprietary
Huntington Beach, CA 92647 International
SECTION 1 - PRODUCT AND COMPANY IDENTIFICATION
CHEMICAL FAMILY:
PRODUCT DESCRIPTION:
Leak Detection Smoke Machines
17852 Gothard Street
ADDRESS (NUMBER, STREET, P.O. BOX)
June 25, 2011
February 4, 2009
MANUFACTURER
01-813-248-05851-800-255-3924
CHEMTEL 24-HOUR EMERGENCY TELEPHONE NUMBER(CITY, STATE AND ZIP CODE)
CARCINOGENICITY: IARC MONOGRAPHS?
North America Toll Free
NO ESIS (EU)? NO
SECTION 2 - HAZARDOUS INGREDIENTS
Overexposure to skin may cause mild irritation.
Not a common route of exposure at room temperature, exposure to heated vapors from this product may cause irritation and coughing.
Overexposure to eyes may cause mild irritiation.
RISK PHRASES
(Full Text Section 15)EINECS #

MATERIAL SAFETY DATA SHEET Page 2 of 4
PRODUCT NAME:
UltraTraceUV®
(Fluorescent Diagnostic Smoke® Solution)
PRODUCT PART NUMBERS: GLD0712UV | GLD0708UV DATE: June 25, 2011
EYES:
SKIN:
TWA ppm TWA mg/m3 STEL ppm STEL mg/m3 TLV/TWA ppm TWA mg/m3 STEL ppm STEL mg/m3
NE NE NE NE NE NE NE NE
Water Spray (Fog), Foam, Dry Chemical and Carbon Dioxide.
INHALATION:
INGESTION:
Flush eyes with clean water for 15 minutes or until irritation subsides. If irritation persists, consult a physician.
NIOSH
Do not handleor store near heat, flames or strong oxidants.
PERSONAL PROTECTION
SECTION 8 - EXPOSURE CONTROLS / PERSONAL PROTECTION
Inhalation at ambient temperatures is not commonly a problem. If overcome by excessive exposure to vapors,
you should remove from exposure to well ventilated area. Some people may experience dizziness, drowsiness or nausea.
If symptoms persist, consult a physician. It is always a good measure of precaution to avoid excessive inhalation of byproduct.
RESPIRATORY PROTECTION:
EYE PROTECTION:
PROTECTIVE GLOVES:
Combustible liquid Flash Point: 335-510°F (168-265°C). Distillation Range: 550-900° F (288-482° C). LEL:0.9% UEL: 7.0%
EXTINGUISHING MEDIA:
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE:
OTHER PROTECTIVE CLOTHING OR EQUIPMENT:
HAZARDOUS COMBUSTION PRODUCTS:
Carbon Monoxide, Soot, Smoke, Carbon Dioxide.
Non-Hazardous
SECTION 4 - FIRST AID MEASURES
SECTION 5 - FIRE FIGHTING MEASURES
Do not induce vomiting as a risk of aspiration exists with this petroleum based product. If ingested, the precaution is to call a physician and our
emergency number immediately.
Remove anycontaminated clothing and wash affected skin area with soap and warm water.
SECTION 7 - HANDLING AND STORAGE
SECTION 6 - ACCIDENTAL RELEASE MEASURES
UNUSUAL FIRE AND EXPLOSION HAZARDS:
ACGIH OSHA
HAZARDOUS COMPONENTS
GENERAL HAZARDS:
FIRE FIGHTING PROCEDURES:
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED:
Do not store or mixbase chemical with strong oxidants. Do not cut, drill, grind, or weld container, as this may cause explosion.
Cool exposed container with water. Use air-supplied (SCBA) breathing equipment for enclosed or confined spaces.
Recover liquid, wash remainder with suitable petroleum solvent or add absorbent. As with all petroleum products, keep out of sewers and water
courses. Advise authorities if ever any petroleum product has entered or may enter sewers or water courses
Use this product in a well ventilated area.
Wash with soap and water after using this product and before eating drinking or smoking.
Eyewash station recommended.
Safety Glasses required.
Not required.
WORK / HYGIENIC PRACTICES:

MATERIAL SAFETY DATA SHEET Page 3 of 4
PRODUCT NAME:
UltraTraceUV®
(Fluorescent Diagnostic Smoke® Solution)
PRODUCT PART NUMBERS: GLD0712UV | GLD0708UV DATE: June 25, 2011
pH
LEL: 0.90% UEL: 7.00%
STABILITY STABLE X
REFERENCE:
LABEL:
Note: Transportation information provided is for reference only. Client is urged to consult CFR 49 parts 100 - 177, IMDG, IATA, EU, United Nations
TDG, and WHMIS (Canada) TDG information manuals for detailed regulations and exceptions covering specific container sizes, packaging
materials and methods of shipping.
NAHAZARD SYMBOLS: Hazard Identification Number (HIN):
0.87-0.89
<1.0 mm Hg @68°F
INCOMPATIBILITY (MATERIALS TO AVOID):
WASTE DISPOSAL METHOD:
PROPER SHIPPING NAME:
SOLUBILITY IN WATERBOILING RANGE/ DISTILLATION RANGE
SPECIFIC GRAVITY (WATER = 1)
APPEARANCE AND ODOR
SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES
Colorless to Very Pale Amber. Mineral Oil Type Odor.
NA
DOT HAZARD CLASS / Pack Group:
NA
Not regulated
NA
49CFR IMDG HAZARD CLASS:
RID/ADR Dangerous Goods Code:
UN TDG Class / Pack Group: NA
NA
NA
UN / NA IDENTIFICATION NUMBER:
NA
SECTION 14 - TRANSPORT INFORMATION
Not regulated Not regulatedIATA HAZARD CLASS / Pack Group:
SECTION 12 - ECOLOGICAL INFORMATION
No ecological information is available for this blended product, however discharge to watercourses as with all petroleum based products should be
avoided.
SECTION 13 - DISPOSAL CONSIDERATIONS
Avoid discharge to watercourses, dispose preferably by incineration at a properly permitted facilityin accordance with all Local, Regional, State and
Federal regulations.
None related to polymerization.
SECTION 11 - TOXICOLOGICAL INFORMATION
Hazardous Components CAS #
EINECS # LD50 of Ingredient
(Specify Species and Route) LC50 of Ingredient
(Specify Species)
Not Hazardous/No Tox data
available.
HAZARDOUS POLYMERIZATION:
HAZARDOUS DECOMPOSITION OR BYPRODUCTS:
Will not occur
Carbon Monoxide, Soot, Smoke, Carbon Dioxide.
EVAPORATION RATE (WATER = 1)
VAPOR DENSITY (AIR = 1)
CONDITIONS TO AVOID:
CONDITIONS TO AVOID:
Strong oxidizers
Excessive heat , sparks open flame, contact with oxidizers.
SECTION 10 - STABILITY AND REACTIVITY
NR
FLAMMABLE LIMITS
FLASH POINT
AUTOIGNITION TEMPERATURE <0.01
>5
335-510°F (168-265°C)
550-900° F ( 288-482°C)
NE
Negligible
VISCOSITY
VAPOR PRESSURE

MATERIAL SAFETY DATA SHEET Page 4 of 4
PRODUCT NAME:
UltraTraceUV®
(Fluorescent Diagnostic Smoke® Solution)
PRODUCT PART NUMBERS: GLD0712UV | GLD0708UV DATE: June 25, 2011
NO NO
Fire: NO NO
Reactive: NO
313 REPORTABLE INGREDIENTS:
HEALTH: 0 = INSIGNIFICANT
1 = SLIGHT
2 = MODERATE
3 = HIGH
4 = EXTREME
REVISION SUMMARY:
Chronic Health:
RISK PHRASES: None required
Legend:
PHYSICAL HAZARD:
FLAMMABILITY:
Ingredients listed on CDSLDSL / NDSL (Canadian Domestic Substances List / Non-Domestic Substances List):
0
1
0
2
Sudden Release of Pressure:
Acute Health:
EINECS (European Inventory of Existing Commercial Chemical Substances):
IDL (Canadian Ingredient Disclosure List):
CPR (Canadian Controlled Products Regulations):
California Prop 65, Safe Drinking Water and Toxic Enforcement Act of 1986:
CERCLA (USA - Comprehensive Response Compensation and Liability Act):
Ingredients Referenced
SARA TITLE III (USA - Superfund Amendments and Reauthorization Act):
TSCA (USA - Toxic Substance Control Act):
Revised toGHS/EU protocols 02/04/2009 supersedes Rev12/2008 issue. ---JTV---
SYMBOL(S) REQUIRED FOR EU LABEL
PERSONAL PROTECTIVE EQUIPMENT:
The information contained herein is believed to be accurate but is not warranted to be so. ChemTel Inc. assumes no responsibility for document alterations or additions
after authorship and initial review excepting changes performed by ChemTel personnel. Data and calculations are based on information furnished by the manufacturer of the
product and manufacturers of the components of the product. Users are advised to confirm in advance of need that information is current, applicable and suited to
the circumstances of use. Vendor assumes no responsibility for injury to vendee or third persons proximately caused by the material if reasonable safety procedures
are not adhered to as stipulated in the data sheet. Furthermore, vendor assumes no responsibility for injury caused by abnormal use of this material even if reasonable
safety procedures are followed. All questions regarding this product should be directed to the manufacturer of the product as described in Section 1.
SAFETY PHRASES:
None listed
SECTION 16 - OTHER INFORMATION
None Listed
MSDS Prepared by:
ChemTel Inc.
1305 North Florida Avenue
Tampa, Florida USA 33602-2902
Toll Free North America 1-888-255-3924 Intl. +01 813-248-0573
Website: www.chemtelinc.com
HMIS HAZARD RATINGS
None required.
NA = Not Applicable NE = Not Established NR = Not Reported (proprietary).
WGK Water Quality Index:
None listed None listed None listed
No RQ's listed.
None reportable.
SECTION 15 - REGULATORY INFORMATION
Listed

25791 Commercentre Drive
Lake Forest, CA 92630
Telephone: 949-448-4100
Facsimile: 949-448-4111
This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek’s responsibility and liability are
limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss,
expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of
the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations
and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an
Intertek certification program.
Intertek Testing Services NA, Inc
EMC VERIFICATION No. 3179331LAX-001g
EQUIPMENT
Type of equipment Evaporate Emissions System Tester
Model GLD-40
Company Global Leak Detection Corp.
Test Report No. 3059793.011 (Intertek – Minnesota)
Test Standard
Emissions
EN 61326:1997, Class B
Immunity
EN 61326:1997, Minimum Immunity Requirements
Summary
The original EMC Verification No. 3059793.011 - 172 was issued from Intertek – Minnesota
office. This verification 3179331LAX-001g reflects the changes of the company name and
product model name. Refer to 3059793.011 for EMC test results details. We confirm that our
review of the above number report without reasonable doubt will fulfill the requirements
concerning electromagnetic compatibility according to the above-mentioned standard.
Prepared by: Martin Liu Reviewed
by: Chandresh Thakur
Title: Project Engineer Title: Engineering Manager
Signature: Signature
Date April 30, 2009 Date: April 30, 2009

Table of contents