Safety Device
Thisapplianceisfittedwithaflueblockage safety device which
will shut down the appliance in the event of abnormal flue
conditions.ThisdeviceisNOTasubstituteforanindependently
mounted Carbon Monoxide detector.
Thesafetydeviceisreset,afterthreeminutes,bypushinginthe
button shown in diagram 1.
Shut down can occur during certain climate conditions, but if it
recurs the chimney flue and air inlet into the room must be
checked and any problems found corrected by a competent
person, before the boiler is used again.
To Light the Boiler
WARNING. If the pilot light goes out for any reason, do not
attempt to relight until three minutes have gone by.
Remove the door by pulling forwards with the fascia at the top.
Lift up to free from bottom side lugs.
Refer to diagram 1 to identify the controls.
Check that the mains electrical supply to the boiler is switched
OFF.
Check that the Flue Blockage Safety Device has not operated,
that is, the button is in. Refer to Safety Device instructions.
Push in slightly and turn gas control knob “A” clockwise until
''is against its setting point.
Turn thermostat control knob “B” anticlockwise until “O” is
against its setting point.
Pushinslightlyandturngascontrolknob“A”anticlockwiseuntil
'' is against its setting point, then push fully and hold in.
Push and release piezo ignition button “C” until the pilot burner
lights.
Air may be present in the supply pipe so the lighting of the pilot
may need to be repeated until all the air has been expelled.
When the pilot is alight, view through window “E”, keep gas
control knob “A” fully pushed in for about 15 seconds, then
release.
If the burner fails to stay alight, wait three minutes, then repeat
thelightingprocedureonlynowkeepcontrolknob“A”depressed
for a little longer before releasing. The Flue Blockage Safety
Device may also need resetting, refer to instructions above.
If the gas control knob “A” is turned to ' ', a safety lock
preventsitbeingturned onagainforashortperiod. No attempt
should be made to relight the pilot for at least three minutes.
Make sure that the pilot is alight and stable, then switch on the
electrical supply.
Press in and turn gas control knob “A” anticlockwise until ' '
is against its setting point.
Set any remote controls to call for heat.
Turn the boiler thermostat knob “B” clockwise until “MAX” is
against its setting point and the main burner will light. Adjust
thermostat to required setting between “MIN” and “MAX”.
“MAX” is about 82oC (180oF).
Refitthedoorbyfittingthehooked runner at the bottomintothe
slot in the side panels and pushing onto the studs.
To Turn the Boiler Off
For short periods. Turn the boiler thermostat control knob “B”
anticlockwise to “O”. The pilot will remain alight. To relight the
main burner turn the thermostat control knob “B” clockwise to
the desired setting between “MIN” and “MAX”.
For longer periods. Push in slightly and turn gas control knob
“A” fully clockwise until “ ” is against its setting point. Turn
thermostat control knob “B” anticlockwise to “O”. Isolate the
boilerfromtheelectricalsupply. Followthefulllightingprocedure
to relight.
Refer also to “Protection Against Freezing”.
Gas Leak or Fault
If a gas leak or fault exists or is suspected the boiler must be
turned off, including the electrical supply and must not be used
untilthefaulthasbeenputright.Advice/helpshouldbeobtained
from the local gas undertaking or your installation/servicing
company.
Protection Against Freezing
If the boiler is to be out of use for any long period of time during
severeweatherconditionswerecommendthatthewholeofthe
system including the boiler, be drained off to avoid the risk of
freezing up. If an immersion heater is fitted in the domestic hot
water cylinder make sure it is switched off.
Sheet Metal Parts
WARNING. This appliance contains metal parts (component)
and care should be taken when handling and cleaning, with
particular regard to edges.
Cleaning
Keep the casing clean by wiping it over occasionally with a
damp soapy cloth and dry with a polishing cloth.
Do not use abrasive cleaners.
Replacement Parts/Boiler Identification
Ifreplacement parts are requiredapply to your localsupplier or
gas undertaking. Please quote the name of the boiler and its
serial number which can be found on the data label positioned
on the boiler top, to the rear of the inclined flueway cleaning
door.
Clearance
Minimumclearancesmustbe leftaroundtheboilerasshown in
diagram 1.2 and 1.3.
Instructions for Use