Glowworm Ultracom sxi User manual

www.glow-worm.co.uk
1
www.glow-worm.co.uk
To be left with the user
Instructions for Use
High Efficiency Condensing Boilers
Ultracom sxi
www.glow-worm.co.uk
2
WARNING
GAS LEAK OR FAULT
Turn off the gas emergency control valve immediately. Eliminate all sources of ignition, i.e.smoking,
blowlamps, hot air guns etc. Do not operate electrical lights or switches either on or off.
Open all doors and windows, ventilate the area.
METAL PARTS
This boiler contains metal parts (components) and care should be taken when handling and cleaning,
with particular regard to edges.
SEALED COMPONENTS
Under no circumstances must the user interfere with or adjust sealed parts.
Glow-worm service call: 01773 828100 Technical helpline: 01773 828300
General and Sales enquiries Tel: 01773 824639 Fax: 01773 820569
www.glow-worm.co.uk
3
13206
G.C. No. 41-019-07
G.C. No. 41-019-08
Ultracom
18sxi
Ultracom
30sxi
www.glow-worm.co.uk
4
Contents Page
Important Information 5
Boiler Design and Clearances 6
Boiler Safety Devices 7
Servicing, Maintenance and Spare Parts 8
User Control Panel 9
Lighting the Boiler 10
Adjusting Temperature 11
Fault Finding 11
These instructions are an integral part of the boiler and must, to comply with the current issue of the Gas
Safety (Installation and Use) Regulations, be left with the user.
Please read these instructions and follow them carefully for the safe and economical use of your boiler.
www.glow-worm.co.uk
5
Gas Safety (Installation and Use) Regulations
In your own interests and that of safety, it is the Law that ALL
gas appliances have been installed by a competent person
in accordance with the current issue of these regulations.
Gas Category
This boiler is for use only on G20 natural gas but can be
converted for use on G31 propane.
Electrical Connection
The boiler MUST be earthed.
The boiler MUST be connected to a permanent 230V ac, 50Hz
supply, fused at 3A.
Connection of the whole electrical system of the boiler,
including any heating controls, to the electrical supply must be
through one common isolator.
The colours of three core flexible cable are, blue - neutral,
brown - live, green and yellow - earth.
Important Information
Testing and Certification
This boiler is certificated to the current issue of EN 483 for
performance and safety.
It is important that no alteration is made to the boiler unless
approved, in writing, by Glow-worm.
Any alteration not approved by Glow-worm, could invalidate the
certification, boiler warranty and may also infringe the current issue
of the statutory requirements.
CE Mark
This boiler meets the requirements of Statutory Instrument, No. 3083
of the Boiler (Efficiency) Regulations, and therefore is deemed to
meet the requirements of Directive 92/42/EEC on the efficiency
requirements for new hot water boilers fired with liquid or gaseous
fuels.
Type test for purposes of Regulation 5 certified by: Notified body
0087.
Product/production certified by: Notified body 0086.
The CE mark on this appliance shows compliance with:
1. Directive 90/396/EEC on the approximation of the laws of the
Member States relating to appliances burning gaseous fuels.
2. Directive 73/23/EEC on the harmonisation of the Laws of the
Member States relating to electrical equipment designed for use
within certain voltage limits.
3. Directive 89/336/EEC on the approximation of the Laws of the
Member States relating to electromagnetic compatibility.
www.glow-worm.co.uk
6
Boiler Design and Clearances
Description
These boilers are designed to be used with a sealed water
central heating system with a fully indirect cylinder, fully
pumped circulation. The pump, expansion vessel and
associated safety devices are all fitted within the boiler.
Once the controls are set the boiler operates automatically.
Pluming from flue terminal
Like all condensing boilers it will produce a plume of
condensation from the flue terminal in cool weather. This is
due to the high efficiency and hence low flue gas temperature
of the boiler. It is normal and not a fault indication.
Compartment or Cupboard Installations
Ventilation is not required for compartment or cupboard
installations. Do not use the compartment or cupboard for
storage.
Diagram 1
150
200
*5
600
CLEARANCES
(from casing panels)
13208
www.glow-worm.co.uk
7
Boiler Safety Devices
Boiler Shutdown
The boiler software is designed to recognise the potential for
an overheat lockout and will shutdown before this happens.
To restart the boiler, press the reset button, see diagram 2.
If the boiler fails to resume normal operation and all external
controls are calling for heat, then call your Installation/Servicing
company or Glow-worm service.
Frost Protection
With the gas and electric supplies ON and irrespective of any
room thermostat setting, the integral frost protection device
will operate the pump when the temperature of the boiler
water falls below 8OC.
The pump will stop after 10 minutes if the temperature is
higher than 10OC or has already reached 35OC.
The burner will only activate if the boiler temperature does not
reach 10OC after 30 minutes or at any time if the temperature
drops to 5OC.
The burner will switch off when the temperature reaches
35OC.
NOTE: Any other exposed areas of the system should be
protected by a separate frost thermostat.
Condensate Drain Blockage
As a safety feature the boiler will stop working if the condensate
drain becomes blocked. During freezing conditions this may
be due to the forming of ice in the condense drain external to
the house. Release an ice blockage by the use of warm cloths
on the pipe. The boiler should then restart. Contact your
Installation/Servicing company or Glow-worm service if the
fault persists.
Safety Discharge Valve
The safety discharge valve and discharge pipe is fitted to the
boiler. This valve MUST NOT be touched. If there is any
discharge from the pipe, switch off the boiler electrical supply,
then call your Installation/Servicing company or Glow-worm
service.
www.glow-worm.co.uk
8
General Note
Servicing/maintenance should be carried out by a competent
person in accordance with the rules in force in the countries
of destination.
If this boiler is installed in a rented property in the UK there is
a duty of care imposed on the owner of the property by the
current issue of the Gas Safety (Installation and Use)
Regulations, Section 35.
Servicing
To ensure the continued efficient and safe operation of the
boiler it is recommended that it is checked and serviced at
regular intervals. The frequency of servicing will depend upon
the site conditions and usage, but in general, once a year
should be enough.
To obtain service, please call your installer or Glow-worm’s
own service organisation using the telephone number on the
inside front cover of this booklet.
Cleaning
The boiler casing can be cleaned using a mild liquid detergent
with a damp cloth, then a dry cloth to polish.
Do not use any form of abrasive or solvent cleaner as you may
damage the paintwork.
Servicing, Maintenance and Spare Parts
Frost Protection
If the mains electricity and gas services are to be turned off for
any long periods during severe weather, it is recommended
that the whole system, including the boiler, should be drained
to avoid the risk of freezing.
Sealed Water Systems
The draining, refilling and pressurising MUST be carried out
by a competent person, contact your Installation/Servicing
company or Glow-worm Service.
Spare Parts
REMEMBER, When replacing a part on this boiler, use only
spare parts that you can be assured conform to the safety and
performance specification that we require. Do not use
reconditioned or copy parts that have not been clearly
authorised by Glow-worm.
If replacement parts are required contact Glow-worm’s own
service organisation using the telephone number on the
inside front cover of this booklet.
Please quote the name and model of the boiler.
The name and model badge is on the front case.
If in doubt seek advice from the local gas company or Glow-
worm’s own service organisation using the telephone number
on the inside front cover of this booklet.
www.glow-worm.co.uk
9
User Control Panel
General Description
The User Control panel consists
of three toggle buttons, a reset
button and display, which will
indicate with symbols the status of
the boiler, refer to diagram 2.
Diagram 2
13473
Control Panel
MODE
PROG
SYMBOLS DISPLAYED ON THE LCD AND DESCRIPTIONS
System Pressure
Max burner display
Min burner display
Temperature
Appliance OFF
Central Heating Function
LCD
DISPLAY
RESET
BUTTON
NOT
USED
CH TEMPERATURE
ADJUSTMENT
TOGGLE BUTTON
MODE and PROG
Glow-worm control (Optional)
Ext
www.glow-worm.co.uk
10
Initial Lighting
Remove the cover plate, see diagram 3.
Check the isolating valves and gas service cock on the
appliance are open, refer to diagram 4.
Note: If you are in any doubt about the boiler being filled
with water contact your installer or Glow-worm's own
service organisation using the telephone number on the
inside front cover of this booklet.
Do not operate the boiler without water.
1. With no demand from any external controls, switch on
the electrical supply to the boiler.
Lighting the Boiler
2. Select your required function, refer to diagram 2, press
"Mode" repeatedly to scroll through your options and select
one of the following:-
Central heating.
Boiler functions ALL switched off.
3. Turn ON your external controls and select the room
temperature required.
The boiler will operate automatically.
Note: The display will indicate the Heating system
pressure in bar or:
•Water temperature, when heating is on.
•Fault Code (see section Fault Finding)
13471
Diagram 4
13538
Diagram 3
COVER PLATE
C- Safety Discharge Valve
D- Condensate drain
A- Central Heating Isolation Valve
B- Gas Service Cock
www.glow-worm.co.uk
11
Adjusting Temperature
Diagram 5
13179
Central Heating
Central Heating
The temperature is factory preset to the minimum 38OC, but
can be adjusted to a maximum of 82OC as required, refer to
diagram 5.
°C
STEP 1
STEP 2
Press the "+ or -" once
the current temperature
will be displayed "flashing".
Press "+ or -" to
increase or decrease the temperature.
The temperature setting will
automatically save after 5 seconds.
Appliance fails to light
The LCD will display a flashing 'F' and code number, press
the reset button on the control panel, see diagram 2.
If the display shows a flashing pressure of 0.4bar or less,
then the system will need to be pressurised. If this or any
fault persists, contact your installer/service provider or
Glow-worm Service, using the telephone number on the
inside front cover of this booklet.
Electrical Supply Failure
The boiler will not work without an electrical supply and
normal operation of the boiler should resume when the
electrical supply is restored.
If the boiler does not resume normal operation, check the
external controls, it may be necessary, to "reset" the boiler,
refer to the section, "Boiler Safety Devices".
Fault Finding
www.glow-worm.co.uk
12
Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions.
Glow-worm, Nottingham Road, Belper, Derbyshire. DE56 1JT
0020020823-02
11.06

Other Glowworm Boiler manuals

Glowworm SUSTAIN 12r -A User manual

Glowworm

Glowworm SUSTAIN 12r -A User manual

Glowworm 24cx User manual

Glowworm

Glowworm 24cx User manual

Glowworm cxi Owner's manual

Glowworm

Glowworm cxi Owner's manual

Glowworm Micron 60FF Operating manual

Glowworm

Glowworm Micron 60FF Operating manual

Glowworm Energy7 Series User manual

Glowworm

Glowworm Energy7 Series User manual

Glowworm Energysaver Combi 80 User manual

Glowworm

Glowworm Energysaver Combi 80 User manual

Glowworm Ultimate 50FF Operating manual

Glowworm

Glowworm Ultimate 50FF Operating manual

Glowworm 12hx User manual

Glowworm

Glowworm 12hx User manual

Glowworm Xtramax HE User manual

Glowworm

Glowworm Xtramax HE User manual

Glowworm 100sxi User manual

Glowworm

Glowworm 100sxi User manual

Glowworm 12 hxi G.C.No. 41-019-01 User manual

Glowworm

Glowworm 12 hxi G.C.No. 41-019-01 User manual

Glowworm Micron 50FF User manual

Glowworm

Glowworm Micron 50FF User manual

Glowworm 12hxi User guide

Glowworm

Glowworm 12hxi User guide

Glowworm Swift flow 120 User manual

Glowworm

Glowworm Swift flow 120 User manual

Glowworm swift flow 80 Operating manual

Glowworm

Glowworm swift flow 80 Operating manual

Glowworm Ultimate 24h User manual

Glowworm

Glowworm Ultimate 24h User manual

Glowworm Betacom 24 User manual

Glowworm

Glowworm Betacom 24 User manual

Glowworm Betacom 4 24c-A User manual

Glowworm

Glowworm Betacom 4 24c-A User manual

Glowworm Energy7 12s-A User manual

Glowworm

Glowworm Energy7 12s-A User manual

Glowworm swift flow 75e Operating manual

Glowworm

Glowworm swift flow 75e Operating manual

Glowworm Ultracom 24cxi User manual

Glowworm

Glowworm Ultracom 24cxi User manual

Glowworm Energy7 12r-A User manual

Glowworm

Glowworm Energy7 12r-A User manual

Glowworm swift flow 100e User manual

Glowworm

Glowworm swift flow 100e User manual

Glowworm Ultracom 24cxi User manual

Glowworm

Glowworm Ultracom 24cxi User manual

Popular Boiler manuals by other brands

ATTACK PELLET 30 AUTOMATIC Plus Instructions for use

ATTACK

ATTACK PELLET 30 AUTOMATIC Plus Instructions for use

PEERLESS PUREFIRE PFC-850 Installation, operation & maintenance manual

PEERLESS

PEERLESS PUREFIRE PFC-850 Installation, operation & maintenance manual

Sime Open 25 BF TS2 Installer's instructions

Sime

Sime Open 25 BF TS2 Installer's instructions

Ferroli BlueHelix HiTech RRT C Instructions for use

Ferroli

Ferroli BlueHelix HiTech RRT C Instructions for use

STIEBEL ELTRON HOT 2.6 N 1600 Premium Operation and installation instructions

STIEBEL ELTRON

STIEBEL ELTRON HOT 2.6 N 1600 Premium Operation and installation instructions

Vaillant aurotherm classic VFK 135/2 VD installation manual

Vaillant

Vaillant aurotherm classic VFK 135/2 VD installation manual

Beretta MYNUTE GREEN Addendum

Beretta

Beretta MYNUTE GREEN Addendum

MHS Boilers MK8 Installation and user guide

MHS Boilers

MHS Boilers MK8 Installation and user guide

Weil-McLain WM97+100 manual

Weil-McLain

Weil-McLain WM97+100 manual

EHC Fusion Comet Series Installation & technical manual

EHC

EHC Fusion Comet Series Installation & technical manual

Baxi NUVOLA 28 Fi Installers and users instructions

Baxi

Baxi NUVOLA 28 Fi Installers and users instructions

Baxi Duo-tec Combi HE a Range User's operating instructions & important warranty information

Baxi

Baxi Duo-tec Combi HE a Range User's operating instructions & important warranty information

Hoval UltraOil 50 Technical information and installation instructions

Hoval

Hoval UltraOil 50 Technical information and installation instructions

Beretta Mynute J 24 C.A.I. E installer and user manual

Beretta

Beretta Mynute J 24 C.A.I. E installer and user manual

Trianco Greenflame Eco Installation, Operation And Service

Trianco

Trianco Greenflame Eco Installation, Operation And Service

Wood heating solution NCB-120-COAL Installation and operating manual

Wood heating solution

Wood heating solution NCB-120-COAL Installation and operating manual

Fondital LINE Tech Installation, use and maintenance

Fondital

Fondital LINE Tech Installation, use and maintenance

Lattner Boiler Company H.E. instruction manual

Lattner Boiler Company

Lattner Boiler Company H.E. instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.